• 제목/요약/키워드: 18F-FDG

검색결과 535건 처리시간 0.036초

$^{18}F-FDG$ PET/CT에서 강한 FDG 섭취를 보인 식도근종 (Esophageal Leiomyoma with intense FDG uptake on $^{18}F-FDG$ PET/CT)

  • 이석모;배상균
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권5호
    • /
    • pp.410-413
    • /
    • 2008
  • A 56 years old woman referred to our hospital with dysphagia and epigastric soreness. Gastroendoscopy revealed huge submucosal tumor with ulceration extending from distal esophagus to lesser curvature of stomach. Subsequent computed tomography(CT) demonstrated soft tissue mass encircling distal esophagus, and 18F-FDG PET/CT demonstrated intense $^{18}F-FDG$ accumulation in it. Finally this case was diagnosed as esophageal leiomyoma based on pathologic evaluation of the surgical specimen.

Diagnosis of Hepatocellular Carcinoma Using C-11 Choline PET/CT: Comparison with F-18 FDG, Contrast-Enhanced MRI and MDCT

  • Chotipanich, Chanisa;Kunawudhi, Anchisa;Promteangtrong, Chetsadaporn;Tungsuppawattanakit, Puntira;Sricharunrat, Thaniya;Wongsa, Paramest
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3569-3573
    • /
    • 2016
  • Purpose: The aim of this study was to compare C-11 choline and F-18 FDG PET/CT, gadoxetic-enhanced 3-T MRI and contrast-enhanced CT for diagnosis of hepatocellular carcinoma (HCC). Materials and Methods: Twelve chronic hepatitis B patients suspected of having HCC by abdominal ultrasonography received all diagnostic modalities performed within a one-week timeslot. PET/CT results were analyzed visually by two independent nuclear medicine physicians and quantitatively by tumor to background ratio (T/B). Nine patients then had histopathological confirmation. Results: Six patients had well differentiated HCC, while two and one patient(s) were noted with moderately and poorly differentiated HCC, respectively. All were detected by both CT and MRI with an average tumor size of $5.7{\pm}3.8cm$. Five patients had positive C-11 choline and F-18 FDG uptake. Of the remaining four patients, three with well differentiated HCC showed negative F-FDG uptake (one of which showed negative results by both tracers) and one patient with moderately differentiated HCC demonstrated no C-11 choline uptake despite intense F-18 FDG avidity. The overall HCC detection rates with C-11 choline and F-18 FDG were 78% and 67%, respectively, while the sensitivity of F-18 FDG for non-well differentiated HCC was 100%, compared with 83% of C-11 choline. The average T/B of C-11 choline in well-differentiated HCC patients was higher than in moderately and poorly differentiated cases (p=0.5) and vice versa with statistical significance for T/B of F-18 FDG (p = 0.02). Conclusions: Our results suggested better detection rate in C-11 choline for well differentiated HCC than F-18 FDG PET. However, the overall detection rate of PET/CT with both tracers could not compare with contrast-enhanced CT and MRI.

Evaluation of 18F Radioactive Concentration in Exhaust at Cyclotron Facility at Chosun University

  • Jeong, Cheol-ki;Jang, Han;Lee, Goung-jin
    • 방사선산업학회지
    • /
    • 제10권1호
    • /
    • pp.37-41
    • /
    • 2016
  • The recent prevalence of PET examinations in Korea has led to an increase in the number of cyclotrons. The medical isotope $^{18}F$ produced in most cyclotron facilities currently operating in Korea is emitted into the environment during the production of [$^{18}F$]FDG, a cancerdiagnosis reagent. The amount of [$^{18}F$]FDG synthesized determines the radioactive concentration of $^{18}F$ in the exhaust. At some facilities, this amount temporarily exceeds the emission limit. In this study, we evaluated the $^{18}F$ radioactivity concentration in the exhaust from the cyclotron facility at Chosun University. The $^{18}F$ radioactivity concentration was measured using an air sampler and a HPGe semiconductor detector. The measurements showed that the radioactive concentration of $^{18}F$ in the exhaust at the cyclotron facility at Chosun University was the highest during [$^{18}F$]FDG synthesis but remained under the legal limit of $2,000Bq\;m^{-3}$.

갑상선미세유두암의 수술 전 진단에서 $^{18}F$-FDG PET/CT: 이중시간 영상의 유용성 ($^{18}F$-FDG PET/CT for the Preoperative Diagnosis of Papillary Thyroid Microcarcinoma: The Value of Dual Time Point Imaging)

  • 서영덕;김성민;김근호;김제룡
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권6호
    • /
    • pp.543-556
    • /
    • 2009
  • 목적: 이중시간 $^{18}F$-FDG PET/CT 영상(dual time point $^{18}F$-FDG PET/CT imaging)을 통해 갑상선미세유두암 원발 병소와 양성 갑상선결절의 FDG 섭취 양상을 비교 평가하고자 하였다. 대상 및 방법: 갑상선유두암으로 진단받고 수술 전 이중시간 $^{18}F$-FDG PET/CT를 시행한 환자들 중 134명의 갑상선미세유두암(154개)과 49명의 1.0 cm 이하의 양성 갑상선결절 양성 갑상선결절(61개)을 대상으로 후향적 분석을 시행하였다. 두 번의 영상에서 모두 갑상선미세유두암과 양성갑상선결절의 최대 표준화섭취계수(SUVmax)와 두 영상 간 SUVmax의 백분율 변화(${\Delta}%SUVmax$), 병소와 정상조직의 SUVmax의 백분율 변화(${\Delta}%L$:B ratio)를 계산하였다. 두 영상 간의 시간 차이는 평균 $23.4{\pm}4.4$분(갑상선 부위 기준 평균 $10.7{\pm}4.4$분)이었다. 결과: 이중시간 $^{18}F$-FDG PET/CT 영상에서 154개의 갑상선미세유두암은 평균 SUVmax가 $4.9{\pm}4.3$ (1.1~29.9)에서 $5.3{\pm}4.7$ (1.0~33.1)로 증가하였고(p<0.001) 평균 $12.3{\pm}23.6%$ (-34.1~85.3%) 증가하였으나, 61개의 양성 갑상선결절은 $2.1{\pm}1.0$ (1.0~5.3)에서 $2.1{\pm}1.3$ (0.9~8.0)으로 변하였고 평균 $0.3{\pm}20.5%$ (-41.7~118.2%) 감소하였다. 또한 갑상선미세유두암은 100개(64.9%)가 두 번째 영상에서 SUVmax가 증가하였으나 양성 갑상선결절은 19개(31.1%)만 증가하였다. 첫 번째 영상보다 이중시간 $^{18}F$-FDG PET/CT 영상에서 더 많은 수의 갑상선미세유두암이 육안적으로 양성 소견을 보였고(62.3% vs. 76.6%, p=0.006), 크기가 0.5 cm 이하인 경우에도 발견율이 증가하였다(38.6% vs. 60.0%, p=0.011). 결론: 갑상선미세유두암의 평가에 있어서 일반적인 한 번의 영상검사(single time point $^{18}F$-FDG PET/CT imaging)에 비해 이중시간 $^{18}F$-FDG PET/CT 영상이 원발 갑상선미세유두암 병소와 양성 갑상선결절을 감별하는데 도움이 되었고, 특히 특히 단일 $^{18}F$-FDG PET/CT 영상에서 불확실 소견 또는 음성 소견을 보이는 경우나 크기가 0.5 cm 이하인 경우에 이중시간 $^{18}F$-FDG PET/CT 영상을 시행하는 것이 병소의 악성여부 감별에 더 도움이 될 수 있을 것으로 판단된다.

상행대정맥 종양혈전을 동반한 재발성 간세포암 환자의 F-18 FDG PET/CT소견 (Detection of Superior Vena Cava Tumor Thrombus by F-18 FDG PET/CT in Recurrent Hepatocellular Carcinoma)

  • 최승진;김철수;변성수;이경희;현인영
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권5호
    • /
    • pp.271-274
    • /
    • 2006
  • We report the case of a 64-year-old man with superior vena cava (SVC) syndrome due to tumor thrombus from recurrent hepatocellular carcinoma (HCC). He presented with new onset of facial swelling for 10 days. HCC was detected ten years ago. He has undergone repeated transcatheter arterial embolization (TAE) and chemotherapy. Chest computed tomography (CT) demonstrated tumor thrombus in the SVC extending to right atrium. He underwent whole body F-18 fluorodeoxyglucose(FDG) positron emission tomography/computed tomography (PET/CT) scanning for assessing the effect of TAE in HCC. F-18 FDG PET/CT showed increased uptake in the residual liver mass indicating viable tumor. There was another intense F-18 FDG accumulation in SUV extending to right atrium to suggest tumor thrombus. This case illustrates that F-18 FDG PET/CT is useful to identification of distant metastases as well as assessment of response to therapy in long-term survival HCC patients.

부신종양에서 $^{18}F-FDG$ PET 및 PET-CT의 임상 이용 (Clinical Application of $^{18}F-FDG$ PET and PET-CT in Adrenal Tumor)

  • 황경훈;최덕주;이민경;최원식
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.130-133
    • /
    • 2008
  • Adrenal tumors are increasingly detected by widespread use of anatomical imaging such as a, MRI, etc. For these adrenal tumors, differentiation between malignancy and benignancy is very important. In diagnostic assessment of adrenal tumor, $^{18}F-FDG$ PET and PET-CT have been reported to have high diagnostic performance, especially, very excellent performance in evaluation of adrenal metastasis in the oncologic patient. In cases of adrenal incidentalomas, $^{18}F-FDG$ PET or PET-CT is helpful if a or chemical-shift MRI is inconclusive. $^{18}F-FDG$ PET and PET-CT may be applied to the patients with MIBG-negative pheochromocytomas. In summary, $^{18}F-FDG$ PET and PET-CT are expected to be effective diagnostic tools in the management of adrenal tumor.

$^{18}F-FDG$ PET/CT 에서 하지골 골수에 다발성 이상섭취를 보인 비특이성 염증성질환 (Non-specific Inflammatory Disease Showed Abnormal FDG Uptake in Lower Extremities)

  • 천경아;공은정;조인호;홍영훈;이충기
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.79-80
    • /
    • 2008
  • Including malignancy, various disease can show abnormal uptake in bone marrow. We report a case of non-specific inflammatory FDG uptake in bone marrow mimicking malignancy. A 35-year old woman with fever of unknown origin (FUO) underwent $^{18}F$-FDG PET/CT to find out fever $^{18}F$-FDG and unknown malignancy. $^{18}F$-FDG was injected and imaged 1hr after injection with Discovery ST (GE, USA), $^{18}F$-FDG PET/CT whole body image showed abnormal uptake in lower extremities (Fig. 1). MRI and biopsy was also done in the sites of abnormal uptake. PET and MRI suspect malignancy (Fig. 2, 3), but biopsy result was non-specific inflammatory process (Fig. 4). The patient was improved her clinical condition after antibiotics therapy.

자동합성장치에 따른 $^{18}F$-FDG의 방사선분해 평가 (Radiolysis Assessment of $^{18}F$-FDG According to Automatic Synthesis Module)

  • 김시활;김동일;지용기;최성욱;최춘기;석재동
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.8-11
    • /
    • 2012
  • 상용화된 자동합성장치는 사용되는 유기용매의 종류가 다르고 합성수율에 차이를 보인다. 따라서 본 연구에서는 자동합성장치에 따른 $^{18}F$-FDG의 방사선분해에 관한 방사화학적순도 변화를 비교하였다. Cyclotron (PETtrace, GE Healthcare)을 사용하여 $^{18}F$를 생산하고, 자동합성장치(FASTlab, Tracerlab MX, GE Healthcare)를 이용하여 FDG로 합성하였다. 방사화화적순도는 Radio-TLC Scanner (AR 2000, Bioscan), GC(Gas Chromatography, Agilent 7890A)를 사용하여 $^{18}F$-FDG에 함유되어 있는 에탄올의 양을 측정하였다. 고정상은 실리카겔로 도포된 유리판($1{\times}10cm$), 이동상은 아세토니트릴과 물 19:1 혼합액을 사용하고, 각각의 합성장치에서 고농도와 저농도의 $^{18}F$-FDG를 생산 후 2시간 간격으로 방사화학적순도를 측정하였다. 저농도 (약 2.59 GBq/mL 이하)에서 순도변화는 Tracerlab MX에서는 99.26%, 98.69%, 98.25%, 98.09%, FASTlab에서는 99.09%, 97.83, 96.89%, 96.62%를 얻었다. 고농도(약 3.7 GBq/mL 이상)에서 순도변화는 Tracerlab MX에서는 평균 99.54%, 96.08%, 93.77%, 92.54%, FASTlab의 경우 99.53%, 95.65%, 92.39%, 89.82%를 얻었다. 그리고 FASTlab에서 생산한 $^{18}F$-FDG의 GC에서는 에탄올이 검출되지 않았으며, Tracerlab MX에서는 100~300 ppm의 에탄올이 검출되었다. 이러한 결과를 비추어 봤을 때 방사선 보호제인 에탄올의 유무보다 방사능농도가 방사선분해에 더 큰 영향을 미치기 때문에 고농도의 $^{18}F$-FDG 생산 후 무균 생리식염수로 희석하여 농도를 낮춘 후 사용해야 한다.

  • PDF

비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용 (Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer)

  • 남궁혁;함준철;김상규;최용훈;임한상;김재삼
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.9-13
    • /
    • 2016
  • 비뇨기암에서의 $^{18}F-FDG$를 이용한 PET-CT 검사는 해부학적 구조 및 $^{18}F-FDG$의 배출 경로로 인해 암 진단에 한계가 있다. 그러한 한계점을 보완 할 수 있는 검사 중 아세트산을 이용한 검사가 진행되고 있으며 비뇨기암 환자를 대상으로 $^{11}C-Acetate$ PET-CT 검사의 임상 적용에 대하여 소개하고자 한다. 현재 본원에서 비뇨기암을 진단 받은 환자 중에 전립선암 환자 10명, 신세포암 환자 10명, 방광암 환자 2명을 총 22명을 임상 연구로 시행하였다. 모든 환자는 $^{18}F-FDG$ PET-CT 검사를 시행하였고, 평균 2주 정도의 기간 후에 $^{11}C-Acetate$ PET-CT 검사를 진행하였다. 검사 장비는 GE사의 D-710 PET-CT 장비를 사용했고, 검사 진행은 $^{11}C-Acetate$ 주사 후 15분 후에 PET-CT 검사를 시작하였고, $^{18}F-FDG$$^{11}C-Acetate$영상의 비교 평가는 핵의학과 전문의가 판별했다. 전립선암 환자의 경우 일반적으로 $^{18}F-FDG$의 섭취가 다른 암종에 비해 낮은 특징이 있다. 본원에서 연구된 10명의 환자 중 2명의 환자의 전이된 암이 $^{18}F-FDG$ 보다 $^{11}C-Acetate$의 섭취가 잘 나타났다. 신세포암의 경우 10명의 환자 중 8명의 환자에서 $^{18}F-FDG$ 보다 $^{11}C-Acetate$의 섭취가 확연히 잘 나타났다. 방광암 환자의 경우 방광의 $^{18}F-FDG$ 섭취가 너무 강하고, 이뇨제 사용여부와 환자의 조건이 맞지 않아 임상연구에서 제외하였다. 현재 임상 연구 진행 중인 검사로서 아직은 많은 환자에 대한 검사를 시행하지 못해서 이렇다 할 결과를 말하기에는 시기상조이다. 하지만, 해외에서는 이미 비뇨기암에서의 $^{11}C-Acetate$ PET-CT 검사가 어느 정도 유용하다는 논문이 많이 발표되었고, 본원에서도 현재 연구 진행 중이다. 보다 더 많은 환자에 대한 검사가 이루어진다면, 전립선암 환자에서 Prostatic specific antigen(PSA) 수치와 $^{11}C-Acetate$ PET-CT의 상관관계, 수술 전 환자에서의 조직 검사상의 Gleason sum 수치와의 상관관계, 다른 비뇨기암에서의 $^{18}F-FDG$ PET-CT 검사와 $^{11}C-Acetate$ PET-CT 검사 사이의 특이도, 민감도, 양성예측도, 음성예측도 등의 척도로서의 비교 등의 다양한 주제로서의 논문이 진행 될 수 있을 것이며, 비뇨기암에서의 $^{11}C-Acetate$ PET-CT 검사가 보다 더 활성화 되어 질 것이라 사료된다.

  • PDF

조영증강 $^{18}F$-FDG PET/CT가 이중에너지 X-선 흡수 계측법을 이용한 골밀도 및 체성분 측정에 미치는 영향 (Effect of Contrast-Enhanced $^{18}F$-FDG PET/CT on Measurements of Whole Body Bone Mineral Density and Body Composition by Dual-Energy X-Ray Absorptiometry)

  • 김성수;이선도;이남주;신용철;모은희;이춘호
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.7-11
    • /
    • 2012
  • PET/CT에 사용되는 방사성의약품 FDG와 CT 조영제가 DXA를 이용하여 측정하는 BMC, BMD, TFM, LBM 등의 결과에 미치는 영향을 알아보고자 하였다. 2011년 12월부터 2012년 3월까지 본원 PET/CT를 시행한 환자 중 본 연구에 참여를 동의한 환자 총 22명을 대상으로 하였다. 실험은 두 집단으로 나누어 실험을 진행하였는데 첫 번째 집단은 17명으로 PET/CT 용 방사성의약품인 FDG 정맥 주사 전에 WB DXA를 시행한 다음 FDG 정맥주사 1시간 후 CT 조영제 사용 없이 PET/CT (Non-Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA를 진행하였다. 두 번째 집단은 총 5명으로 첫 번째 집단과 마찬가지로 FDG 정맥 주사 전 WB DXA를 시행한 다음 FDG 정맥 주사 1시간 후 CT 조영제 사용하여 PET/CT (Contrast Enhancement $^{18}F$-FDG PET/CT)시행 후 즉시 다시 WB DXA 진행하였다. 결과는 PET/CT 전 후 DXA에서 WB-BMC, WB-BMD, TFM 그리고 LBM 등을 측정하였고 각 항목의 변화율을 산출하여 비교하였다. Non-Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 골밀도 및 체성분의 변화율은 WB-BMC, +2.4%; WB-BMD, +1.8%; TFM, -6.8%; LBM, +2.2%였고 각 항목의 변화는 통계적으로 유의한 차이가 없었다. Contrast Enhancement $^{18}F$-FDG PET/CT 전 후의 변화율은 WB-BMC, +13.7%; WB-BMD, +9.3%; TFM, -34.1%; LBM, +13.6%였고 Contrast Enhancement $^{18}F$-FDG PET/CT 전과 후의 골밀도 및 체성분 측정치의 변화는 통계적으로 유의하였다. 본 연구에서 Non-Contrast Enhancement $^{18}F$ PET/CT 후에는 DXA 시행은 결과에 영향이 없어 가능할 것이라 생각되어지나 Contrast Enhancement $^{18}F$-FDG PET/CT검사 후에 시행한 DXA 검사의 결과는 신뢰도가 감소될 것으로 사료된다.

  • PDF