• Title/Summary/Keyword: 17B

Search Result 6,635, Processing Time 0.033 seconds

A Study on the Characteristics and Vitalization Strategy for the Multi-Complex Shopping Mall (복합쇼핑몰 활성화 방안에 관한 사례연구)

  • Cha, Seong Soo;Park, Cheol
    • Journal of Distribution Research
    • /
    • v.17 no.5
    • /
    • pp.129-146
    • /
    • 2012
  • Recently, Korea became the 7th country in the world which has got into the 20-50 clubs that means the population is 50 million and per capital income is $20,000. From the view point of the retail industry, it suggests that Korea should have its own self-sufficient market by itself. With abundant labor and increased disposable income, it made the consumer's needs change. Responding to the change, retail and F&B oriented retail malls are now starting to add culture, art and entertainment facilities in the configurations. Such complexity and variety of the shopping malls became trendy and many shopping complexes are scheduled to open in the near future across the country. Due to above reasons, it became the common trend to develop shopping complex all over the cities now. However, the history of the shopping mall in Korea is much shorter than developed countries such as America and Japan. Thereby, a lot of problems, trial and error have occurred in the process of developing and operating them. If development of shopping complex failed, it would return lots of damages to the stakeholder. Therefore, the corporations should develop the mall properly and government might support positively. In this study, we would like to propose on how all the mall should be developed and well managed and what are the ways for the vitalizing factors of the shopping complex after benchmarking other shopping mall cases. Through the case study, we realized that the most crucial factors for vitalizing shopping complex were interior design, merchandising and how well they operate the mall. In case of the failed shopping mall, developers sell each store to individual proprietors and never take care of them after they get the profit, which make it hard to have integrated marketing strategies. That causes the overall slump of the mall. Corporations developing the mall should operate it as well, so that it could be possible to make the mall consistently well managed and promoted. There is a certificate for the shopping mall expert in The States and Japan. However, we do not have this kind of certificate. In fact, if we judge the capability of a person who is involved in the shopping mall industry, we usually measure how many years they stick to the same industries and that is not equally the same as their competence. Therefore it is necessary to organize "Shopping Mall Associate" and introduce shopping mall license for the mall expert. Due to retail trends, we can easily see a lot of shopping facilities all over the cities but not every mall is able to be successful. We think it's essential that the government should certify the malls which are qualified for the design, merchandising and proficiency of the operation. For the qualified mall, the government could confer a benefit on the company such as reducing corporation taxes. In multi-complex shopping mall it is possible to make convenient for customers. However, if a mall failed to succeed, it would be disaster. To build a shopping complex, developers should invest huge money even take out loan so that many people would be connected to the project, which may affect their whole financial conditions. In addition, only qualified corporation should develop and operate shopping complex and the government must support and aid the developers in order to make a better shopping environment in which customers might be happy during their shopping experience.

  • PDF

The Impact of Changes in Market Shares among Retailing Types on the Price Index (소매업태간 시장점유율 변화가 물가에 미친 영향)

  • Moon, Youn-Hee;Choi, Sung-Ho;Choi, Ji-Ho
    • Journal of Distribution Research
    • /
    • v.17 no.2
    • /
    • pp.93-115
    • /
    • 2012
  • This study empirically examines the impact of changes in market shares among retailing types on the price index. The retailing type is classified into 6 groups: department store, big mart, super market, convenient store, specialty merchant, and on-line store. The market shares of retailing types are calculated by the ratio of each retailing type monthly sales to total monthly retailing sales in which total retailing sales is the sum of each retailing type sales. We employed several price indices: consumer price index (CPI), CPI for living necessaries, and fresh food price index. In addition, this study used fundamental price indices based on 25 product families as well as 42 representative products. The empirical model also included several variables in order to control for the macroeconomic effects and those variables are the exchange rate, M1, an oil price, and the industrial production index. The data is monthly time-series data spanning over the period from January 2000 to December 2010. In order to test for the stability of data series, we conducted ADF test and PP test in which the model and length of lag were determined by the relevant previous literature and based on the AIC. The empirical results indicate that changes in market shares among retailing types have impacts on the price index. Table A shows that impacts differ as to which price index to use and which product families and products to use. For department store, it lowers the price of food and non-alcoholic beverages, home appliances, fresh food, fresh and vegetables, but it keeps the price high for fresh fruit. The big mart retailing type has a positive impact on the price of food, nut has a negative effect on clothing and foot wear, non-food, and fresh fruit. For super market, it has a positive impact on food and non-alcoholic beverages, fresh food, fresh shellfishes, but increases the price of CPI for living necessaries and non-food. The specialty merchant retailing type increases the price level of CPI for living necessaries and fresh fruit. For on-line store type, it keeps the price high for CPI for living necessaries and non-food as well as fresh fruit. For the analysis based on 25 product families shows that changes in market shares among retailing types also have different effects on the price index. Table B summarizes the different results. The 42 representative product level analysis is summerized in Table C and it indicates that changes in market shares among retailing types have different effects on the price index. The study offers the theoretical and practical implication to these findings and also suggests the direction for the further analysis.

  • PDF

Origin of the Cold Water below $10^{\circ}C$ Occurring in the Southern Coastal Region of the Korean East Sea in Summer by Ra Isotope Distribution (Ra동위체로 본 하계 동해 남부 연안해역에 출현하는 $10^{\circ}C$ 이하 냉수괴의 기원)

  • YANG Han-Soeb;KIM Pyoung-Joong;LEE Jae-Chul;MOON Chang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.4
    • /
    • pp.404-412
    • /
    • 1994
  • Radium isotopes were measured together with oceanographical parameters in the southern coastal region of the Korean East Sea during the period of September $2{\sim}8$, 1991. In September, there were various water masses vertically distributed in this region due to formation of strongly seasonal thermoclines. These water masses were characterized by activity of radium isotopes as well as water temperature and dissolved oxygen. Among the water masses, Japan Sea Proper Water(JSPW) below $1^{\circ}C$ had the highest Ra-226 activities but the lowest Ra-228 concentrations. However, Tsushima Surface Water (TSW) above $20^{\circ}C$ in water temperature had the highest Ra-228 which decreased sharply with depth. In TSW, Ra-228 activities were in the range of $194{\sim}270$ dpm/kl, which were approximately 10 times higher than JSPW. Activity ratios(A.R's) of Ra-228/Ra-226 were $1.9{\sim}2.6$ for TSW, $0.7{\sim}1.1$ for Tsushima Middle Water(TMW) of $12{\sim}17^{\circ}C\;to\;0.4{\sim}0.7$ for North Korea Cold Water(NKCW) with $1{\sim}7^{\circ}C$ and below 0.2 for JSPW. The Ra-228/Ra-226 ranged from 0.6 to 0.9 in the cold waters of $2{\sim}6^{\circ}C$, which were observed at depth of $65{\sim}120\;m$ in this study area. Radium isotopes provided a useful means of identifying origins of the cold water which occurred annually at intermediate or bottom layers in the southern coastal zone of the Korean East Sea. By plotting radium isotopes against water temperature, it could be observed clearly that the cold waters between $2{\sim}6^{\circ}C$ did not originate from the mixed water of JSPW and TMW but from NKCW.

  • PDF

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF

Quality Characteristics of Soybean Curd Mixed with Freeze Dried Onion Powder (동결건조 양파분말을 첨가한 두부의 품질특성)

  • Kang, Nan-Suk;Kim, Jun-Han;Kim, Jong-Kuk
    • Food Science and Preservation
    • /
    • v.14 no.1
    • /
    • pp.47-53
    • /
    • 2007
  • Soybean curd was mixed with onion powder to develop new foods, and changes in quality characteristics were investigated. The moisture content of onion soybean curd rose as the proportion of onion powder increased Whiteness (as measured by the L value) was high in soybean cud admixed with 0.1% (w/v) onion powder, Redness (the a value) was not significantly altered (the readings were 1.03-1.54) on addition of various onion powder concentrations. Yellowness (the b value) was similarly unaffected (readings 13.00-13.93) when various levels of onion powderwere added. Free sugar analysis showed that glucose was high in soybean curd (67.22 g/100 g) admixed with 0.1% (w/v) onion powder, The main organic acid was tartaric acid, and control organic acids included citric and oxalic acids at high levels. The major free amino acids were L-arginine, ${\gamma}-Amino-n-butyric$ acid, L-histidine, L-glutamic acid, L-serine, L-tyrosine and L-threonine, and amino acid content were high in soybean curd admixed with 0.2% (w/v) onion powder. Major phenolic compounds of onion soybean curd were quercitrin, protocatechuic acid and caffeic acid. The hardness of onion soybean curd was similar to that of the control when onion powder was added to 0.1% or 0.2% (w/v), and decreasedmore onion powder was added. Organoleptic qualities dropped as onion powder levels increased. In summary, onion powder addition to soybean curd is optimal at the 0.2% (w/v) level..

Quality Characteristics of Semi-dried Red Pepper During Frozen Storage (반건조 고추의 냉동저장 중 품질 특성)

  • Sung, Jung-Min;Han, Young-Sil;Jeong, Jin-Woong
    • Food Science and Preservation
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • We investigated the effect of freezing on changes in the chemical components of semi-dried red pepper (SDRP). We used storage temperatures of $0^{\circ}C,\;-10^{\circ}C,\;-20^{\circ}C,\;and\;-70^{\circ}C$. After 30 days of storage, capsaicin content had decreased by 40% at $0^{\circ}C$ and by 21% at $-20^{\circ}C$. Initial vitamin C content was 1,358.02 mg%. Compared with control, the $0^{\circ}C$ storage group showed a significant decrease in vitamin C content but no such decrease was noted in the $-20^{\circ}C$ and $-70^{\circ}C$ storage groups after 30 days. ASTA values were not influenced by storage temperature or period, in agreement with previous results. We concluded that storage was effective at temperatures of less than $-20^{\circ}C$. Next, both dried red pepper (DRP) and SDRP were stored at $-20^{\circ}C$ for 12 months. DRP had the lower level of capsaicinoids (55.01 mg%) owing to the long drying time. After 12 months, SDRP capsaicinoid had decreased by 30-33%, compared with a decrease of 54% in DRP. Initial vitamin C contents were 721.48 and 955.25 mg% in DRP and SDRP, respectively, and, after 12 months, vitamin C loss in the SDRP group (37%) was less than that in fresh red pepper (FRP) samples (45%). Initial $\beta$-carotene content was greatest in the FRP group (259.82 mg%), and that of DRP decreased by 20% after 12 months. The color a/b value of SDRP (1.40) was greater than that of DRP (1.00).

Effects of High Pressure on Quality Stability of Fresh Fruit Puree and Vegetable Extracts During Storage (고압처리가 신선 과채음료의 저장기간 중 품질 안정성에 미치는 영향)

  • Kim, Young-Kyung;Lee, Yong-Hyun;Iwahashi, Yumiko
    • Food Science and Preservation
    • /
    • v.17 no.2
    • /
    • pp.190-195
    • /
    • 2010
  • Pressure, used as a minimal processing technology in the food industry, is a valuable tool ensuring microbiologically safe, shelf-stable fruit and vegetable production. Pressure could be used to deliver a greater variety of minimally processed products, as demanded by today's consumers. Weevaluated the effect of <400 MPa pressure, applied during chilling, on fresh fruit purees (strawberry, kiwi, aloe, and pomegranate) and vegetable extracts (from carrot and spinach) during cold storage (<$10^{\circ}C$) for 15-20 days. Samples were prepared in a processing facility in which total plate counts of falling and floating bacteria were controlled at $1{\times}100-10^1$ CFU/plate and $1{\times}10^2-10^3$ $CFU/m^3$ under conditions of $21-25^{\circ}C$ and 55-60% relative humidity. The aerobic plate counts of raw materials were less than $1{\times}10^3$ CFU/g. Evaluation parameters included microbiological safety, vitamin content, and sensory qualities. Although the overall quality of non-treated samples deteriorated with storage time at $10^{\circ}C$, samples pressurized at 250-350 MPa at $5-7^{\circ}C$ for 10 min showed less change, with no significant difference in microbiological safety, vitamin content, or sensory quality. The use of pressure extended the shelf-life during storage at $10^{\circ}C$.

Quality Characteristics of Chun Ma (Gastrodiae rhizoma) Beverage Prepared Using Concentrated Extracts (천마추출액 농축 비율을 달리하여 제조한 천마음료의 품질특성)

  • Lee, Su-Won;Moon, Hye-Kyung;Moon, Jae-Nam;Yoon, Won-Jung;Kim, Gwi-Young
    • Food Science and Preservation
    • /
    • v.17 no.1
    • /
    • pp.58-65
    • /
    • 2010
  • We investigated the effect of Chun ma (Gastrodiae rhizoma) concentrated extract on the quality of mixed beverages. Chun ma beverages prepared using different concentrated extracts were divided into four groups: GCE 5 ($5^{\circ}$ Brix concentrated extracts) GCE 10 ($10^{\circ}$ Brix concentrated extracts) GCE 15 ($15^{\circ}$ Brix concentrated extracts) and GCE 20 ($20^{\circ}$ Brix concentrated extracts). The pH values ranged from a low of 4.37 in GCE 5 to a high of 4.68 in GCE 20. Soluble solid levels in GCE 20 ($19.6^{\circ}$ Brix) were higher than in the other samples. The b (yellowness) scores and the total phenolic contents of all samples increased with increasing extract concentration. The highest total phenolic contents were seen in GCE 20 samples at 232.23 mg%. Samples did not differ markedly in antiradical activity (75.07-76.00% DPPH inhibition). Free sugar levels in GCE 20 samples and organic acid concentrations of GCE 15 samples were higher than those of other preparations. Free amino acid and mineral contents of all samples increased with increasing extract concentration. The levels of free amino acids were in the order Glu > Gly > Ser > Arg > Hylys, and the Glu content was 249.15 ug/100 g for GCE-20 samples and 61 ug/100 g in GCE-5 products. The mineral contents of all samples were in the order K > Na > Mg > Ca. Higher scores for color, flavor, and overall acceptability were found in GCE 5 products compared with other extracts. These results indicate that Chun ma beverage can be prepared in various ways, as commercially desired, with reference to the above characteristics of Chun ma materials.

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF