• Title/Summary/Keyword: 17-KS

Search Result 169, Processing Time 0.056 seconds

A Study on Test Module of Smart Cards in Electronic Payment Systems (전자지불시스템에서 이용되는 스마트카드의 시험 모듈 구성에 대한 연구)

  • 김윤정;이기한
    • The Journal of Society for e-Business Studies
    • /
    • v.9 no.1
    • /
    • pp.303-320
    • /
    • 2004
  • Smart card is a useful tool used in electronic payment systems and it is very important to test whether a smart card operates correctly. In this paper, we analyze previous researches on testing smart cards, such as ISO/IEC and KS standard documents, and Guideline of Card Quality Test. We also propose the functional test results done on the Highpassplus card of Korea Highway Corporation. By testing the Hipgpassplus card we can get card systems with reliable functionality and security. Furthermore, this can help developing more reliable security systems. The test results of the Highpassplus card proposed in this paper are the first research on testing smart cards in services in Korea and we expect that the test methods of smart card will be advanced based on our results.

  • PDF

Establishment of Design Standard and Analysis of Insulation Property for Underground Space in Architecture (건축물의 지하공간을 위한 단열재의 특성 분석 및 설계 기준 수립)

  • Hwang, Min-Kyu;Cho, Woo-Jin;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The purpose of this study is to analyze an insulation property and to establish a design standard for the underground space in architecture. Insulation materials for this study are 12 kinds of Insulation which qualified KS standards(3 classes of EPS type 1, 3 classes of EPS type 2(Neopor), 3 classes of XPS and 3 classes of PU Boards). For insulation materials of underground space, insulating and water tightening property are desired. So conductivity for insulating and water absorption for water tightening are measured in this study. Temperature, insulation is exposed to in the underground space, is different from temperature above the ground. Conductivity is measured in a temperature of $17^{\circ}C$, $20^{\circ}C$, $23^{\circ}C$ and $26^{\circ}C$. In KS standards, water absorption are measure after 24 hours, but insulation is exposed to water for a long time in the underground. So after 110 days, water absorption are measured. As time goes by, increasing of water absorption means decreasing of water tightening and insulating. So after water absorption had measured for 110 days, conductivity has measured again. As a result, XPS is selected as optimized insulation for underground. And Conductivity of XPS insulation with water should be added by 20%.

A Study on the K-joints Using Square Hollow Steel Sections in Truss (각형강관 트러스의 K형 접합부에 관한 연구 ( I ))

  • Kim, Hong Joon;Park, Kuem Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.3-17
    • /
    • 1996
  • The purpose of this paper is to investigate experimentally and theoretically the strength and deformation of K-joints in welded Warren-type square hollow structural section truss. There are 2 types in K-joints in K-joints having one compression bracing member and one tension bracing member. One type is KP-series that brae members are rotated to $45^{\circ}$, another type is KS-series that are not rotated. Principal parameters are the ratio of the chord width to thickness (D/T=33.3, 25, 16.7), the ratio of brace width to chord width(d/D=0.4, 0.5, 0.67, 0.83, 1.0) and the ratio of eccenticity to chord height (e/D=0.25, 0.125, 0, -0.125, -0.25, -0.375, -0.5). The important results obtained from the experiments are as follow ; The strength of K-joints increase proportionally as the D/T ratio decreases, and the d/D ratio increases. But the e/D ratio has no correlation with the strength of K-joints. Generally the strength and ductility ratio of KP-series increase more than a current type(KS-series) in full ${\beta}$range.

  • PDF

A Study on MDA Analysis & blood chemical test for Mouse which were exposed HF Gases from Fire (화재로 인한 불화수소(HF)가스에 노출된 마우스의 혈액생화학분석 및 MDA분석을 통한 세포손상에 관한 연구)

  • Cho, Nam-Wook;Oh, Eun-Ha
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.58-66
    • /
    • 2013
  • Among the risks which can be faced with fire, combustion toxicity is a significant influence on the survival. Fire toxicity researches have been limited generally on the lethal aspects. In this study, HF gas which can be generated from fire, and also found in general industrial site was used for analysis. Blood analysis and biochemistry analysis performed to find internal demage of experimental animals which were used for measuring average activity stopping time from Animal test(KS F2271: Gas hazard test). In addition, Using the malondialdehyde analysis, indicators of oxidative damage, we had quantitative analysis to target lymphocyte for measuring the oxidative damage caused by toxic substances.

Properties and Mock-up Test of Lightweight Foamed Concrete Based on Blast Furnace Slag by Crack Reducing Admixture (팽창성 균열저감제를 이용한 고로슬래그 미분말 기반 경량기포 콘크리트의 특성 및 목업실험)

  • Han, Sang-Yoon;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.507-515
    • /
    • 2017
  • This study is to develop a high quality lightweight foamed concrete that can be applied in the field using EXFG by cracking reducing agent combined with FGD and ALS. First, to increase the volume of foam, the flow and density of the mixture was increased and decreased, respectively. At this time, the effect of substitution ratio of EXFG on fluidity was negligible. The fraction of foam was the highest at EXFG 1%, and the settlement was found to be prevented by the expansion reaction at EXFG 1%. At this time, the ratio of foam was 65%. In the compressive strength, the strengths were similar or decreased when the substitution ratio of EXFG was more than 1%. The apparent density satisfied the KS 0.5 type at the bubble contents was 65%. In case of EXFG substitution, dry shrinkage was decreased by about 10%. As the substitution ratio of EXFG increased, the thermal conductivity increased proportionally.

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Investigation of Material Characteristics of Reinforced Concrete Beam After Exposure to Fire Test (화재 실험에 따른 철근 콘크리트 보의 재료특성 연구)

  • Ju, Min-Kwan;Park, Cheol-Woo;Oh, Ji-Hyun;Seo, Sang-Gil;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.33-41
    • /
    • 2016
  • Concrete is inherently a good fire-resistance material among all other constrcution materials and protects the reinforcing steel inside. This study investigates the material characteristics of concrete and steel bar inside the full scale reinforced concrete(RC) beam exposed to fire test. The fire test specimen was 4 m long and the test was conducted under no loading condition following KS F 2257. Fire source is simulated by ISO 834 and number of thermocouples were installed to measure temperature variation of surfaces and inside of the beam. The measured compressive strength of cored specimen, which was exposed to fire test, was 11 MPa, about 66% lower than the strength before exposure. The yielding strength of steel bar also decreased about 75 MPa, about 17% lower. The measured temperature of protected steel bar was around $649^{\circ}C$, the critical limit, after 4 hour exposure.

Thermal Insulation Performance of Composite Waterproofing Method of Thermal Supplement Type (단열 보완형 복합방수공법의 단열성능에 관한 연구)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 2014
  • Insulation of rooftop is one of the major performance to energy-saving construction. Further, waterproofing performance is also important. For such a reason, it is need to develop waterproofing method containing thermal insulation property. This study was wanted to evaluate thermal insulation performance about the composite waterproofing method of thermal supplement type that is developed recently. As a result of waterproofing performance test, every test item was showed over the performance standards of KS (Korean (Industrial) Standards). And the result of thermal insulation performance test, the highest temperature in the styrofoam box was $25.91^{\circ}C$, the bubble sheet box was $17.28^{\circ}C$, the insulation sheet box was $15.47^{\circ}C$ and the waterproofing sheet box of thermal supplement type was $24.11^{\circ}C$. In observations of thermal bridges of sheet's joint, thermal bridges was not identified at the sheet's joint. As a result, composite waterproofing method of thermal supplement type is interpreted to have thermal insulation performance.

A Study on the Nano Silica-Sol Coating for Improving Performance of Recycled Aggregate (순환골재의 성능향상을 위한 나노실리카졸의 코팅에 관한 연구)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Ko, Ji-Soo;Kim, Il-Kon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.84-90
    • /
    • 2013
  • In this study we propose an effective method, Coating processing methods, which can improve the quality of recycled aggregate relatively easily without new equipment investment and complex treatment process and verify the improved effect using the devised method, Coating processing methods. To attain the research aim we used adequately diluted silicate solution for coating and carried out several property valuation for twelve types of material with different coating method. Also we formed concrete with coated aggregates which showed the best property. In conclusion the aggregates with the method of repeated impregnation in the silicate and drying showed the most excellent quality while other coating methods also resulted in an improvement of aggregate quality but failed to meet the KS Standard. Lastly with the optimal material we could obtain the approved compressive strength from the concrete allowing it to be utilized for road facility of which standard compressive strength of design is under 24MPa.

Effects of Dissolved Inorganic and Organic Nutrient (Nitrogen and Phosphorus) on the Growth of Dinoflagellate Alexandrium affine (와편모조류 Alexandrium affine의 생장에 미치는 용존태 무기 및 유기 영양염(질소와 인)의 영향)

  • Oh, Seok Jin;Kim, Ji Hye;Park, Kyung Woo;Kim, Seok-Yun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.630-638
    • /
    • 2021
  • In this study, we investigated the effects of dissolved inorganic and organic nutrient on the growth of dinoflagellate Alexandrium affine (LIMS-PS-2345). The maximum uptake rates (ρmax) and half saturation constants (Ks) calculated from the uptake kinetics experiment were 77.0 pmol/cell/hr, 17.6 μM for nitrate and 15.5 pmol/cell/hr, 3.88 μM for phosphate, respectively. These results suggested that this species has high inorganic nutrient demand and a low affinity for inorganic nutrients. During the utilization of organic nutrients for A. affine, growth rates of experimental groups added by organic nitrogen (urea and glycine) and phosphorus (adenosine triphosphate and glycerol phosphate) were above 70 %, compared to the experimental groups added by inorganic nutrients. Thus, A. affine may need to utilize organic nutrients to understand the dominant strategy and advantageous position in the interspecific competition within low inorganic nutrient environments.