Study(III) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - The Proper Use of Long-term Allowable Compressive Load of PHC Piles by Analyzing Quality Test and Product Specifications Data - (사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(III) - 품질 성능 검사 자료 및 성능 제원 표 분석을 통한 PHC말뚝의 장기허용압축하중 성능의 올바른 활용 -)

  • Kim, Chae Min;Yun, Dae Hee;Lee, Chang Uk;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.9
    • /
    • pp.15-28
    • /
    • 2019
  • Long-term allowable compressive Loads of PHC piles were analyzed based on qualification tests results by 17 small and medium PHC pile producing companies and product specifications by 6 major and 17 small and medium PHC pile producing companies. At the present stage, an average long-term allowable compressive load of PHC pile was designed at 70% level from current design data, and safety factor of 4.0 was applied to long-term allowable compressive loads of PHC pile despite of its excellent quality. Most quality standards of PHC pile are specified at KS F 4306. But compressive strength test method of spun concrete is specified at KS F 2454. As a result of analyzing quality test data supplied by each manufacturer, all quality test results showed higher performances than standard values. Therefore, it was considered that the capacity of PHC pile can be used up to the maximum allowable compressive load of PHC pile when PHC pile is designed.

Disposal Pattern and Its Impact on Milk Production and Herd Size in Karan Fries and Karan Swiss Cows

  • Singh, M.K.;Gurnani, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.9
    • /
    • pp.1214-1218
    • /
    • 2004
  • Data on 958 Karan Fries (KF) and 780 Karan Swiss (KS) cows, born during 1974 to 1992 at National Dairy Research Institute, Karnal were evaluated for causes of culling and their impact on milk performance and herd strength. Causes of culling were classified as voluntary culling (low milk yield) and involuntary culling (other than milk yield). The milk yield of cows was evaluated inretrospectively by estimating expected breeding value (EBV) on the basis of first lactation yield (FLY) and all available lactation yield (ALY). The culling rate of KF cows over the years varied from 10.89 (1988) to 33.92% (1991) with an overall average of 20.96% and in KS from 19.91 (1984) to 33.74% (1989) with an overall average of 25.01%. Reproductive disorders, teat and udder problems, low milk production, health and locomotive disorders were the major reasons of culling accounted respectively for 5.56, 4.97, 4.61, 3.18 and 2.24% of herd strength in KF cows. The corresponding causes of culling were 6.20, 6.26, 7.69, 1.49 and 2.67% of herd strength in KS cows. The involuntary culling of cows accounted for 82.4% in K F and 76.1% in KS cows of total culling. The average annual disposal rate in KF and KS was 26 and 30% whereas annual replacement rate was 24 and 26% respectively. The EBV of involuntary culled cows on the basis of FLY and ALY was 3,111 and 3,515 kg in KF; and 2,669 and 2,940 kg in KS cows respectively. The EBV of selected cows on the basis of FLY and ALY was 3,242 and 3,549 kg in KF and 2,893 and 3,245 kg in KS cows respectively. The average breeding value of involuntary culled cows was not significantly different from selected cows in both the herds. The high rate of involuntary culling of potential cows might be major factor responsible for declined performance and size in these herds. The results indicated that higher genetic gain (2.14% of herd average in KF and 3.49% of herd average in KS) could be obtained by restricting the involuntary culling (50% of total culling) through improved management practices and increasing replacement rate.

Antiproliferative Effects of Caesalpinia sappan Extract on Human Epithelial Cell Line HaCaT and Cancer Cell Lines (인체 상피세포주와 암세포주에 대한 소목 추출물의 증식억제 효과)

  • Han, Man-Deuk;Kim, Eung-Kwon
    • Journal of dental hygiene science
    • /
    • v.7 no.1
    • /
    • pp.31-35
    • /
    • 2007
  • Caesalpinia sappan L. (Leguminosae) is an oriental medicinal herb distributed in China and Taiwan, and its heartwood has been traditionally used as an analgesic, a therapy for thrombosis or tumor. This study was to investigate the proliferation and inhibition effects of Caesalpinia sappan extracts against human epithelial cell and cancer cell lines. The methanol extract of dried C. sappan heartwood was evaporated (KS-6), and then sequentially extracted by hexane (KS-01), chloroform (KS-02), ethyl acetate (KS-03), n-butanol (KS-04), and water (KS-05). After 48 hr of exposure, these fractions at a concentration of $50{\mu}g/ml$ significantly increased, and reduced cell proliferation in both human normal epithelial and cancer cell lines. The ethyl acetate fraction (KS-03) among organic solvent fractions was 120.2% of the most proliferation activity ($50{\mu}g/ml$) against HaCaT human epithelial cell. However, fractions from chloroform, butanolic and methanolic extract had 7.2, 28.7 and 20.8% of antiproliferative effect on HaCaT cell, respectively. In cell proliferation effects of C. sappan extract on HeLa, SiHa and C33A human cervical cancer cells, chloroform fraction (KS-2) was the most antiproliferative activity, its antiproliferative rate (dosage, $50{\mu}g/ml$) relative to control was 25.8, 12.2 and 17.4% for SiHa, HeLa and C33A, respectively. The results indicated that the six extract fractions could induce cell cycle stimulate or arrest in some way. Finally, further investigation is needed to assess the molecular mechanisms mediated anticancer activities of this plant.

  • PDF

Analysis on Hypothetical Multiple Events of mSGTR and SBO at CANDU-6 Plants Using MARS-KS Code (중수로 원전 가상의 mSGTR과 SBO 다중 사건에 대한 MARS-KS 코드 분석)

  • Seon Oh YU;Kyung Won LEE;Kyung Lok BAEK;Manwoong KIM
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.1
    • /
    • pp.18-27
    • /
    • 2021
  • This study aims to develop an improved evaluation technology for assessing CANDU-6 safety. For this purpose, the multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout (SBO) in a CANDU-6 plant was selected as a hypothetical event scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes logic models for controlling the pressure and inventory of the primary heat transport system (PHTS) decreasing due to the u-tubes' rupture, as well as the main features of PHTS with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was successfully achieved to confirm the stable convergence of the key parameters. Until the turbine trip, the fuel channels were adequately cooled by forced circulation of coolant and supply of main feedwater. However, due to the continuous reduction of PHTS pressure and inventory, the reactor and turbine were shut down and the thermal-hydraulic behaviors between intact and broken loops got asymmetric. Furthermore, as the conditions of low-flow coolant and high void fraction in the broken loop persisted, leading to degradation of decay heat removal, it was evaluated that the peak cladding temperature (PCT) exceeded the limit criteria for ensuring nuclear fuel integrity. This study is expected to provide the technical bases to the accident management strategy for transient conditions with multiple events.

Quality Tests for the Knee-Orthosis Velcro and Locking System (무릎보조기 벨크로 및 잠금장치에 대한 품질시험 연구)

  • Jung, Se-Wook;Seo, Won-San;Cho, KiHun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.275-283
    • /
    • 2016
  • In this study, three knee-orthoses (dial lock type, medium size, right side) were used for a quality level test (static bending test and solidity test of the locking system) of the knee-orthosis locking system. In the static bending test, a smaller maximum load was observed in samples A and C compared to the reference standard value (KS P 8408 standard value: 1000 N, sample A: 865 N, sample C: 833 N). In addition, in the solidity test of the locking system, a smaller maximum load was observed in the all samples compared to the referenced standard value (KS P 8411 standard value: 200 N, sample A: 41 N, sample B: 97 N, sample C: 54 N). Korean industrial standards for knee-orthoses and systematic test methods are lacking. Therefore, a systematic management plan for knee-orthoses is required. The result of the current study showed that a systematic management plan for the knee-orthosis locking system is required. In particular, the development of a quantitative and objective test method is needed. The findings of the current study may be useful for monitoring the quality of the knee-orthosis locking system and may provide foundational information for the development of a quantitative and objective test method.

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

정부시책

  • Korea Electrical Manufacturers Association
    • NEWSLETTER 전기공업
    • /
    • no.93-17 s.90
    • /
    • pp.6-19
    • /
    • 1993
  • PDF