• Title/Summary/Keyword: 17-KS

Search Result 170, Processing Time 0.023 seconds

Indoor Illuminance Evaluation on a Mirror Sunlighting System Applied to the Apartments under Real Sky Condition (거울형 태양광 채광시스템의 실제 건축물 적용에 따른 실내주광조도 평가)

  • Jung, Joo Hee;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.137-145
    • /
    • 2010
  • Active sunlighting systems have been applied to deliver sunlight into the indoor space where natural light is insufficient, mainly because of the congested high-rise buildings in urban areas. Among various active sunlighting systems, a mirror sunlighting system which is simple structure and economically reasonable has been widely used in different types of spaces such as underground, north facing place and atrium. This study was to evaluate the mirror sunlighting systems, which were consisted of the first mirror of $3.5m{\times}2.5m$, the eight sets of the second mirrors of $1.0m{\times}1.25m$ and a sun tracker. Ten sets of the systems were installed for 40 apartment living rooms, the configuration of $3.5m(W){\times}4.0m(D){\times}2.5m(H)$ where sunlighting were not possible due to high retaining walls located in the front of the living rooms. The 45 HOBO data logger sensors for the indoor illuminance were equipped and 2 Li-cor photometers for outdoor illuminance. Both indoor and outdoor horizontal illuminances were monitored every second from 9am to 3pm on 17 January 2010 under clear sky condition. The results showed that the indoor illuminance of installed mirror sunlighting system was significant relationship with outdoor illuminance and increased the indoor illuminance level by 4.2 times on the whole floor space, by 8 times on the sun patch space of 6m2 and even by 2 times on the no sun patch space. In addition, the luminous conditions of the living room under real sky conditions met the KS recommendation for difficult task (600-1000-1500 lux) such as sewing and reading on whole floor space and sun patch space. It was proved that the benefits of mirror sunlighting systems included an effective technology for penetrating daylight into indoors where sunlighting was not possible and improving occupants' satisfaction and health, and contributing to energy saving in apartments during daytime.

Study on the Long-term Reliability of Photovoltaic Module in the Cell level (태양전지의 Cell 레벨에서의 장기 신뢰성에 관한 연구)

  • Kim, Koung-Hwan;Jeon, Yu-Jae;Kim, Do-Sok;Jo, Il-Jea;Shin, Young-Eui
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.177-181
    • /
    • 2012
  • 본 연구는 고온고습 시험을 통하여 Cell 레벨에서의 표면관찰 및 효율저하를 분석하였다. 고온고습 시험 조건은 KS C IEC-61215에서 제시한 PV module하의 조건을 이용하여 온도 $85^{\circ}C$, 습도 85% 조건하에 1000시간 동안 수행하였다. 고온고습 시험에 따라 효율에 직접적인 영향을 줄 수 있는 이상 유 무를 Cell 표면을 통해 분석한 결과, 고온고습 시험 수행 중 부분적으로 변색되는 것을 확인하였다. 고온고습 시험 전 단결정 Cell의 효율은 17.74% 였으며, 1000시간 수행 후 15.63%으로 11.89%의 감소율을 보였다. 다결정 Cell의 시험 전 효율은 15.46%, 1000시간 수행 후 효율은 14.02%로 9.31%의 감소율을 보였다. 경년 시 나타나는 전기적 특성을 분석하기 위해 FF(Fill Factor)값을 분석한 결과, 고온고습 시험 전 단결정 Cell은 78.71%에서 75.01%로 4.7%의 감소율을 보였으며, 다결정 Cell은 78.10 %에서 76.66%로 1.84%의 감소율을 보였다. 효율 및 FF값에서 단결정 Cell이 다결정 Cell보다 감소율이 큰 것으로 분석되었으며, 이는 단결정 Cell이 외부 환경에서 더욱 크게 작용하여 효율저하에 영향을 주었다고 판단된다.

  • PDF

Sasang Constitution May Act as a Risk Factor for Post Traumatic Stress Disorder (외상 후 스트레스 장애의 위험요인으로서의 사상체질)

  • Kim, Yunyoung;Kim, Tae-Yeol;Park, Soyoung;Jang, Eunsu
    • Journal of Sasang Constitutional Medicine
    • /
    • v.32 no.1
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, we suggested indirect evidence of whether Sasang constitution(SC) could be a risk factor for Post-traumatic stress disorder(PTSD) among soldiers who participated in Vietnam war. The number of 199 subjects joined this study. We surveyed SC with KS-15 and PTSD with Korean Version of Impact of Event Scale-Revised questionnaires. A Chi-square test and a one-way ANOVA were performed according to SC type, and multiple logistic regression was used to produce odds ratios(ORs). Significant p was .05. The number(rate) of Taeeumin(TE), Soeumin(SE), and Soyangin(SY) types were 131(65.8%), 33(16.6%), and 35(17.6%) respectively. The score of PTSD in SE type(8.78±8.61) was significantly higher than those of SY(4.00±6.5) and TE types(3.65±6.78)(p=.001, SE>TE, SY, Scheffe). SE type was associated with increased PTSD prevalence compared with TE [OR 4.338; 95% CI 1.525-12.335, p<.01], and it was still associated with increased PTSD prevalence [OR 10.658; 95% CI 1.296-87.661, p<.05] after adjusting for age and weight. This study suggests that SC, particularly the SE type, might be significantly associated with PTSD and could be considered as a risk factor for PTSD.

Clinical Pharmacokinetics of Vancomycin in Gastric Cancer Patients (위암 환자에서 반코마이신의 임상약물동태)

  • Choi, Jun-Shik;Chang, Il-Hyo;Burm, Jin-Pil
    • YAKHAK HOEJI
    • /
    • v.41 no.2
    • /
    • pp.195-202
    • /
    • 1997
  • The purpose of this study was to determine pharmacokinetic parameters of vancomycin using two point calculation(TPC) and Bayesian methods in 16 Korean normal volunteers and 15 g astric cancer patients. Nonparametric expected maximum(NPEM) algorithm for calculation of population pharmacokinetic parameter was used, and these parameters were applied for clinical pharmacokinetic parameters by Bayesian analysis. Vancomycin was administered 1.0g every 12 hrs for 3 days by IV infusion over 60 minutes. The volume of distribution(Vd), elimination rate constant(Kel) and total body clearance(CLt) of vancomycin in normal volunteers using TPC method were $0.34{\pm}0.06 L/kg,\; 0.19{\pm}0.01 hr^{-1}$ and $4.08 {\pm} 0.93 L/hr$, respectively, The Vd, Kel and CLt of vancomycin in gastric cancer patients using TPC method were $0.46 {\pm} 0.06 L/kg, 0.17{\pm}0.02 hr^{-1}$ and $4.84 {\pm} 0.57 L/hr$ respectively. There were significant differences(p<0.05) in Vd. Kel and CLt between normal volunteers and gastric cancer patients. Polpulation pharmacokinetic parameter, the slope(KS) of the relationship beetween Kel versus creatinine Clearance, and the Vd were $0.00157{\pm}0.00029(hr{\cdot}mL/min/1.73m^2)^{-1},\; 0.631 {\pm} 0.0036 L/kg$ in gastric cancer patients using NPEM algorithm respectively. The Vd and Kel were $0.63{\pm}0.005 L/kg, 0.15 {\pm}0.027 hr^{-1}$ for gastric cancer patients using Bayesian method. There were significant differences(p<0.05) in vancomycin pharmacokinetics between Bayesian and TPC methods. It is considered that the population parameter in the patient population is necessary for effective Bayesian method in clinical pharmacy practise.

  • PDF

Investigation of Production Condition of Ready-Made and MTM Men's Suits - Focusing on Brands of Department Store - (신사 정장 브랜드의 기성복 및 MTM 생산 실태 조사 - 백화점 입점 브랜드를 대상으로 -)

  • Choi, Jin Young;Song, Hwa Kyung
    • Fashion & Textile Research Journal
    • /
    • v.18 no.6
    • /
    • pp.746-754
    • /
    • 2016
  • This study aimed to investigate the status of ready-made suit and MTM (Made-to-measure) suit production with 10 men's suit brands turning over 200 billion won. Their target age group is late 30's to late 40's. Regarding production for the ready-made suit, eight out of 10 brands are using both KS and their own sizing. Classification of body shapes was done in 8 brands, mostly for upper body in simple ways (lean, normal, and obese). All brands are conducting fittings on only standard size. The number of sizes produced is varying depending on the brands; 9 to 17 for a jacket and 9 to 20 for a pair of pants. Regarding on the MTM production, four out of 10 brands have implemented MTM production. The rate of MTM production to their total production is about 15-20%. There were positive opinions on MTM production since it enables to reduce stocks through a small quantity of production for necessary sizes only. The reasons of orders of MTM production were answered as 'no size available', 'unique body shape', etc., and most orders were placed by consumers who are fat-bellied or have thick thighs. They have used MTM automated CAD software developed by Gerber Technology or Investronica. All the brands have utilized automated marker-making software and cutting facilities for MTM production.

A Study on Elderly Women's Breast Types and Their Brassiere Sizes (노년여성(老年女性)의 유방형태(乳房形態) 분석(分析)과 브래지어 착용(着用) 치수분포(値數分布) 연구(硏究))

  • Park, Sung-Yi;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.5 no.4
    • /
    • pp.144-157
    • /
    • 2001
  • The purpose of this study was to research on breast shape and size to suggest a brassiere sizing chart for elderly women. For this purpose 90 elderly women aged between 55 and 69 were sampled at random to review their breast types by age group, and thereby, suggest the basic measurements and production ratio of each brassiere size in reference to KS K 0070: 1999. The collected measurement data were processed statistically using the SPSS PC/WIN program for technical statistical analysis. The results of this study can be summarized as follows; 1. Analysis of Breast Measurements To find out difference among age groups, the 90 subjects were grouped into three(Group 1 ; aged 55 to 59, Group 2 ; aged 60 to 64, Group 3 ; aged 65 to 69). The results of the comparative analysis of anthropometric data from three groups show that getting older;- Various length measurements related to the drooping degree of breast were increased. It was found that the older group in their 65-69's had more drooping breasts than their 55-59's or 60-64's counterparts. Such findings suggests that older women's drooping can be corrected by a brassiere which serves to support the breasts. 2. Suggestions on a Brassiere Sizing For the basic measurements of brassiere parts for the elderly women, the correlation between underchest circumferences and cup sizes were analyzed. 3% or higher occurrences among the whole sample elderly women were included in the brassiere sizes. thus, the under-chest measurements were set at four intervals from 75 to 95, while the cup measurements were determined also at four intervals from "AAA" to "B" sizes. The resultant 6 sizes excluding the least frequent occurrences covered 73.2% of the sample elderly women actual breast sizes. As a consequence of reviewing the production ratio of each brassiere size for the women, it was found that the brassiere size of highest production ratio was "85A" (17.4%), followed by 80A (14.5%), 85AA 90A (10.1%) and 75A (8.7%) in their order.

  • PDF

the Antibacterial Activities of Persimmon Juice and Persimmon Juice Dyed Cotton Fabrics (감즙과 감즙염색 면직물의 항균성)

  • Han Youngsook
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.3 s.205
    • /
    • pp.119-129
    • /
    • 2005
  • The antibacterial activities against Staphylococcus aureus of persimmon juice and persimmon juice dyed cotton fabrics were eveluated. We investigated the effects in pursuit of the proper treating conditions to use persimmon juice dye for comfortable and hygienic doffing. The antibacterial activities were estimated by test method KS K 0693 and the percentage reduction of bacteria at various contact conditions of test materials and bacteria. The results were as follows. no bacteriostatic activities (BS) of persimmon Juice were more than $99.98\%$ and the increase was dose-dependent according to concentration from $1\%$ to $10\%$. However, bactericidal activities (BC) were not found BS increased from $99.97\%$ to $100\%$ and BC from $79.74\%$ to $100\%$ with increasing persimmon juice concentration of cotton fabrics from $10\%$ to $100\%$. Antibacterial effects were significantly shown at $10\%$ of persimmon juices. BS increased from $75.69\%$ to $100\%$ and BC from $65.89\%$ to $100\%$ over 18 hours of contact time and continued for 50 hours. BS of $100\%$ persimmon juice dyed cotton fabrics increased from $96.56\%$ to $98.20\%$ and BC from $-136\%$ to $65\%$ at different incubation temperatures of $17\pm1^{\circ}C$, $27\pm1^{\circ}C$ and $37\pm1^{\circ}C$. BS ranged from $99.06\%$ to $99.99\%$ and BC from $84.31\%$ to $95.10\%$, according to the initial bacterial density from $4.08\times10^7$ to $4.08\times10^5$. Sixty-seven percent of subjects of answered not to smell any odor from persimmon juice dyed cotton fabrics by subjective test.

An Analysis of the Fitting of Plus-sized Women's Formal Jackets in On-line Shopping Malls (온라인 쇼핑몰의 플러스 사이즈 여성 정장 재킷 사이즈 실태 분석)

  • Ha, Hee-Jung
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.2
    • /
    • pp.203-215
    • /
    • 2009
  • The purpose of this study was to investigate current garment sizes of women's formal jackets, targeting plus-size women in online shopping malls, and to identify effective size information involved in online apparel purchase behaviors to overcome the short comings of current garment sizes from the perspectives of consumers. Basic 88 size formal jackets from the seven companies found on the 22 websites were collected and analyzed. The data were collected from March to October 2007, and analyzed using SPSS 14.0. The results were summarized as follows. First, there was no website using standard garment size labeling with 'bust-hip-height' set up by KS K 0051 among the 22 websites. Instead, all 22 websites used garment size labeling with figures such as 88, 99, 100, 110, and 120 or with letters such as L, XL, and XXL. The websites presented no body size, but listed garment size. Furthermore, the size information was presented differently, ranging from three items of bust circumference, upper arm length, and jacket length to six items of shoulder width, bust circumference, waist circumference, sleeve width, sleeve length, and jacket length. In addition, no website presented basic information for hip circumference, despite the jacket length covering the hips. Second, a total of 85.7% the websites listed bust circumferences in 88 garment sizes collected as 100cm. Shoulder widths were presented as 39cm or 37cm. Sleeve circumferences were addressed the same, 36cm, in all websites. Third, comparing the differences between guidance sizes and measurement sizes, only 28.5% of the web sites posted guidance sizes of shoulder widths the same as those of the measurement sizes. All web sites presented guidance sizes of bust circumstances as 1 to 5cm smaller than those of the measurement sizes.

  • PDF

Comparative Analysis of Refractive Power on Trial Case Lenses (검안렌즈의 굴절력 비교 분석)

  • Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.321-334
    • /
    • 2012
  • Purpose: In this study, the distribution and differences in refractive powers on trial case lenses were investigated. Methods: We measured refractive powers at optical center and periphery using 4 trial case lens sets. According to international standards, the distribution and uniformity in refractive powers were investigated. Results: The lens shapes were different in different kinds of trial case lenses and some of lenses were out of tolerance according international standards. In some cases, the power differences were found between front and back side as well as between optical center and peripheral regions and also the cylindrical power on spherical lens and spherical power on the cylindrical lens were measured. Conclusions: Trial case lens are used to assess the refractive error, therefore, more precise control of the manufacturing process for trial case lenses and more thorough quality control will be required to offer an accurate vision test. More careful attention in using trial case lens is also required.

Damage Pattern and Operation Characteristics of a Thermal Magnetic Type MCCB according to Thermal Stress (열동전자식 MCCB의 열적 스트레스에 따른 소손 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.69-73
    • /
    • 2013
  • The purpose of this paper is to analyze the carbonization pattern and operation characteristics of an MCCB. The MCCB is consisted of the actuator lever, actuator mechanism, bimetallic strip, contacts, up and down operator, arc divider or extinguisher, metal operation pin, terminal part, etc. When the actuator lever of the MCCB is at the top or the internal metal operation pin is in contact with the front part, the MCCB is turned on or off. It means trip state if the actuator lever or the internal metal operation pin moves to back side. In the UL 94 vertical combustion test, white smoke occurred from the MCCB when an average of 17~24 seconds elapsed after the MCCB was ignited and black smoke occurred when an average of 45~50 seconds elapsed. It took 5~6 minutes for the MCCB surface to be half burnt and took an average of 8~9 minutes for the MCCB surface to be entirely burnt. In the UL 94 test, the MCCB trip device operated when an average 7~8 minutes elapsed. If the MCCB trip has occurred, it may have been caused by an electrical problem such as a short-circuit, overcurrent, etc., as well as fire heat. From the entire part combustion test according to KS C 3004, it was found that the metal operation pin could be moved to the MCCB trip position without any electrical problems.