• 제목/요약/키워드: 166Ho-DTPA

검색결과 4건 처리시간 0.019초

Preparation of an Amino Acid Based DTPA as a BFCA for Radioimmunotherapy

  • Choi, Kang-hyuk;Hong, Young-Don;Pyun, Mi-Sun;Choi, Sun-Ju
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권8호
    • /
    • pp.1194-1198
    • /
    • 2006
  • For the purpose of developing more effective chelating agents, we have synthesized a diethylene triamine pentaacetic acid(DTPA) analogue by using an amino acid. S-(N-Boc-aminophenyl)-Cys(t-Bu4-DTPA) methylester was prepared in 6 steps with total yield of 47.9%. For the sake of introducing a biomolecule to the DTPA derivative, a selective hydrolysis was performed with 3 M HCl/Ethylacetate = 1 : 3 ($25{^{\circ}C}$, 30 min, vigorous stirring). $^{166}Ho$-Cys-DTPA and $^{166}Ho$-Biotin-Cys-DTPA were prepared by mixing $^{166}Ho$ with DTPA derivatives at room temp in a HCl solution (pH = 5) and the radiochemical stabilities (> 99%) were maintained for over 6 hrs in vitro.

Absorbed Dose from Large Balloon Filled with Liquid Ho-166

  • Joh, Chul-Woo;Park, Chan H.;Lee, Myoung-Hoon;Yoon, Seok-Nam;Kim, Mi-Hwa;Jang, Ji-Sun;Park, Kyung-Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.328-330
    • /
    • 2002
  • Large balloon angio catheter is used for Percutaneous Transluminal Angioplsty(TPA) of the iliac, femoral and renal arteries as well as after Transjugular Intrahepatic portosystemic shunt(TIPS). The use of angioplasty balloon filled with liquid form of radioisotope reduces the rate of restenosis after PTA. The purpose of this study was to evaluate the absorbed dose to the target vessels from various sized large balloon filled with liquid form of Ho-166-DTPA. Four balloons of balloon dilatation catheters evaluated were 5, 6, 8 and 10 mm in diameter. GafChromic film was used for the estimation of the absorbed dose near the surface of the balloon catheters. Absorbed dose rates are plotted in units of Gy/min/GBq/ml as a function of radial distance in mm from the surface of balloon. The absorbed dose rate was 1.1, 1.6, 2.2 and 2.3 Gy/min/GBq/ml at a balloon surface, 0.3, 0.4, 0.5 and 0.6 Gy/min/GBq/ml at 1 mm depth for various balloon diameter 5, 6, 8 and 10 mm in diameter respectively. The study was conducted to estimate the absorbed doses to the vessels from various sized large balloons filled with liquid form of Ho-166-DTPA for clinical trial of radiation therapy after the PTA. The absorbed dose distribution of Ho-166 appeared to be nearly ideal for vascular irradiation since beta range is very short avoiding unnecessary radiation to surrounding normal tissues.

  • PDF

풍선도자관의 Ho-166-DTPA 흡수선량 (Absorbed Dose for the Endovascular Ho-166-DTPA Brachytherapy Using a Balloon Angio Catheter)

  • 조철우;박찬희;윤석남;강해준;김미화;장지선;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.98-103
    • /
    • 2002
  • 관상동맥 성형술 시행시 재협착률을 줄이기 위하여 풍선도자에 Ho-166을 주입하였을 때 혈관 주위에 전달되는 방사선의 흡수선량을 여러 가지 풍선 직경에 따라 평가하였다. 액체 상태의 Ho-166은 한국원자력연구소에서 중성자핵반응인(n, ${\gamma}$)반응으로 얻었다. 혈관 내벽의 흡수선량을 구하기 위하여 GafChromic film과 개조한 마이크로 메터를 이용하여 거리에 따른 홉수선량을 구하였다. 풍선내의 방사능 농도와 조사시간을 고려하여 흡수선량율의 단위를 Gy/min/GBq/ml 로 구하였다. 이는 단위체적당의 방사능 즉 방사능농도(GBq/ml)에 따른 분당 흡수선량 즉 흡수선량률(Gy/min)이다. 직경이 2.5, 3.0, 3.5, 4.0 mm인 풍선도자의 풍선의 표면에서의 흡수선량율은 각각 0.86, 1.01, 1.11, 1.24 Gy/min/GBq/ml 로 측정 되었다. 풍선표면에서부터 거리에 따라 급격히 감소하는 흡수선량을 정확하게 측정 할 수 있는 방법을 제시하였다. 또한 진공펌프를 이용하여 풍선내의 공기방울을 제거하여 균일한 흡수선량이 되도록 하였다.

  • PDF