• Title/Summary/Keyword: 120Hz

Search Result 487, Processing Time 0.028 seconds

A New 120Hz DC Output Ripple-Voltage Suppression Scheme Using BIFRED Converter with Unity Power Factor (단위 역률을 갖는 BIFRED 컨버터를 이용한 새로운 120Hz DC 출력 리플-전압 저감 제어 기법)

  • Kim Jung-Bum;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.542-546
    • /
    • 2004
  • This paper presents a technique to reduce the low frequency ripple voltage of the dc output in a BIFRED converter with a small-sized energy storage capacitor. The proposed pulse width control method can be effectively used to suppress the low frequency ripple appeared in the dc output and still shows generally good performance such as low THD of input line current and high power factor. Using the small-sized energy storage capacitor, it has better merits of low cost and small size than a conventional BIFRED converter. The proposed technique is illustrated its validity and effectiveness through simulations.

  • PDF

Time-division Visible Light Communication Using LED Lamp Light

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.145-150
    • /
    • 2015
  • We introduce a new method of time-division visible light communication (VLC) using LED lamp light for the generation of synchronizing pulses. The LED lamp, driven by an AC 220-V power line, radiates light that has a 120-Hz frequency component. The pulse generator in each VLC system receives the LED lamp light and generates the synchronizing pulses that are required for time-division transmission of multiple VLC channels. The pulse period is subdivided into several time slots for VLC channels. In experiments, 120-Hz synchronizing pulses were generated using LED lamp light, and three VLC channels were transmitted independently without interfering with each other in a condition where the VLC signals overlapped in space. This configuration is useful in constructing multiple wireless sensor networks that are safe and without interference in locations where LED lamps are used for illumination.

Fabrication and Characteristics of Transformers for High Power Density SMPS (고밀도 SMPS 용 변압기의 제조와 특성)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jung-Sub;Oh, Yong-Woo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.7-10
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8W capacity, with 70V input voltage and 8.2V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 ${\mu}H$, which was the inductance efficiency of 85~87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 ${\Omega}$ and 0.25 ${\Omega}$ respectively. On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96~0.97 under 120 kHz switching frequency. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

  • PDF

Novel Impulsive Driving Schemes for 120Hz LCD Panels

  • Nam, Hyoung-Sik;Oh, Jae-Ho;Shin, Byung-Hyuk;Oh, Kwan-Young;Berkeley, Brian H.;Kim, Nam-Deog;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.818-821
    • /
    • 2007
  • Two new impulsive driving technologies for use in 120Hz LCD panels are proposed to improve moving picture quality. One technology generates the dark frame using an adder and a shifter simply without using any LUTs. The other is a backlight flashing method designed to avoid ghost images. Using the PBET metric, measured MPRT values were 10.8ms and 4.4ms, respectively.

  • PDF

A Study on the Conducted Noise of the Intrabuilding Power Line (건물내 전력선에 존재하는 전도성 잡음에 관한 연구)

  • 정호영;강창언
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.1
    • /
    • pp.55-62
    • /
    • 1991
  • In this paper, the characteristics of the conducted noise on the intrabuilding power line are measured and analyzed with three steps. In the result, the conducted noise on the intrabuilding power line is mainly divided into three types: the random disturbance which is the background noise with full band spectrum, the harmonic noise correlated with the 60Hz power frequency, and the periodic impulse noise of 120 Hz synchronized with the 60Hz power frequency.

  • PDF

The Vibration and Stress Analysis of Stiffened Box Structures (보강 박스 구조물의 진돔 및 응력 해석)

  • Lee, Young-Shin;Han, Jae-Do;Han, You-Hie;Suh, Jung
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.147-161
    • /
    • 1996
  • The stress and vibration analysis of stiffened box structure is investigated by experiment and FEM analysis. The effects of stiffener number and box section shape on the structure response are presneted. The 1st natural frequency of stiffened folded byx structure with a stiffeners is 300 Hz. It is highter than that of stiffened rectangular box structure with 5 stiffeners, which is 251 Hz. Maximum deflection of folded box structure with thickness of 1 mm is lower than that of rectangular box structure with thickness of 1 or 2 mm. The natural frequencies of box structures are increeased with the number of stiffener, while the deflections are decreased with the number of box structures. When we compare between fundamental frequency (251 Hz) of stiffened (with 5 stiffeners) and one (137.64 Hz) of unstiffened rectangular box structure under clamped-clamped boundary condition, the ratio of frequency increase is 82%. The stiffened structures of 2 mm thickness can reduced to 120% of maximum deflection of 1 mm thickness rectangular box structures.

  • PDF

Wake Flow Control by Acoustic Perturbation (음향섭동에 의한 후류유동의 제어)

  • 이종춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.451-459
    • /
    • 1998
  • THe influence of internal acoustic exitation through a square prism on the turbulent wake flow characteristics was investigated. The intermediate wake region where is about ten times the respective length of the body was experimentally investigated using a conditional phase average technique. At first the static base pressures of square prism and the shedding frequencies have been measured at various internal acoustic exciation frequencies. The experiment were performed under the four cases of internal acoustic excitation frequencies 0Hz 30Hz($St_e$=0.09) 65Hz($St_e$=0.20) 120Hz($St_e$=0.38) And velocity vector fields were presented and discussed. The influence of acoustic exvitation frequencies on the structure of intermediate turbulent wake region is evident. As the internal acoustic frequency increased shedding frequency gradually increased and aerodynamic force decreased. Also it was found that the vortex shedding occurs dratically well and shedding frequency reached nearly the same value as the internal acoustic frequency. but above Strouhal number 0.3 the influence disappeared.

  • PDF

GaN Boost Converter Development for High Power Density (GaN HEMT를 적용한 고전력밀도의 부스트 컨버터 개발)

  • Jeong, Hoejeong;Kim, Katherine A.
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.225-226
    • /
    • 2017
  • 본 논문에서는 WBG소자인 GaN HEMT를 적용한 고전력밀도의 부스트 컨버터개발을 제안하였다. GaN HEMT는 문턱전압이 낮아 인덕턴스에 민감하므로 인덕턴스를 최소화시키는 PCB 레이아웃을 설계하였다. 입력단에 60V의 직류전원을 연결한 후, 출력 전압을 120V, 출력 전력을 100W와 200W로 고정하여 주파수에 따른 소자의 온도와 효율을 측정하였다. 주파수를 100kHz에서 1MHz까지 100kHz간격으로 변화시켜 실험하였고, 부하전력과 주파수가 커질수록 GaN HEMT의 온도가 상승하였다. 컨버터 효율은 부하전력이 100W이고, 주파수가 100kHz일 때 91.7%로 가장 낮은 효율이 나타났고, 부하전력이 200W, 주파수가 600kHz일 때 97.4%로 가장 높은 효율이 나타났다.

  • PDF

Influence of Sustain Pulse-width on Electrical Characteristics and Luminous Efficiency in Surface Discharge of AC-PDP

  • Jeong, Yong-Whan;Jeoung, Jin-Man;Choi, Eun-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.276-279
    • /
    • 2005
  • Influences of sustain pulse-width on electrical characteristics and luminous efficiency are experimentally investigated for surface discharge of AC-PDP. A square pulse with variable duty ratio and fixed rising time of 300 ns has been used in the experiment. It is found that the memory coefficient is significantly increased at the critical pulse-width. And the wall charges and wall voltages as well as capacitances are experimentally measured by Q- V analysis method along with the voltage margin relation, in terms of the sustain pulse-width in the range of $1{\mu}s$ to $5{\mu}s$ under driving frequency of 10 kHz to 180 kHz. And the luminous efficiency is also experimentally investigated in above range of sustain pulse-width with driving frequency of 10 kHz to 180 kHz. It is noted that the luminous efficiency for 10 kHz and 180 kHz are 1.29 1m/W and 0.68 1m/W respectively, since the power consumption for 10 kHz is much less than that for 180 kHz. It has been concluded that the optimal sustain pulse-width is in the range of $2.5 {\~}4.5{\mu}s$ under driving frequency range of 10 kHz and 60 kHz, and in the range of $1.5 {\~} 2.5{\mu}s$ under driving frequency range of 120 kHz and 180 kHz based on observation of memory coefficient, and wall voltage as well as luminous efficiency.

Vibration Analysis of a Generator-Stator Core Under Electromagnetic Excitation (전자기력에 의한 발전기 고정자 코어의 진동 해석)

  • 김철홍;주영호;박종포
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.747-753
    • /
    • 1999
  • This paper presents results of vibration analysis of a generator-stator core for 500 MW fossil power plant. A finite element analysis using a commercial S/W is performed to estimate alternating electromagnetic forces, mainly of 120 Hz in 60 Hz machines, acting on the core, and then to calculate forced response of the core. Results are compared with design requirements.

  • PDF