• Title/Summary/Keyword: 120Hz

Search Result 487, Processing Time 0.025 seconds

Underwater Sound Characteristics of Gray Whale(Eschrichtius robustus) (귀신고래(Gray whale, Eschrichtius robustus)의 수중명음 특성)

  • Shin, Hyeong-Il;Lee, Young-Hoon;Seo, Du-Ok;Lee, Dae-Jae;Hwang, Doo-Jin;Kim, Zang-Geun;Lee, Yoo-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.3
    • /
    • pp.189-195
    • /
    • 2004
  • The underwater sound of California gary whale was analyzed to discuss obtained results from the previous data to compare the underwater sound between Korean gray whale and California gray whale. The frequency of low frequency rumble which occupy about 50% of the underwater sound changed to max. 654Hz and the average of its lasted time was 570msec. The range of frequency variation was coincided as compared with the previous data. The range of frequency variation for the bubble type sounds and knocks was 24${\sim}$1029Hz, respectively. The average of lasted time was 1100msec and 1364msec, respectively. The range of frequency variation and lasted time of bubble type sounds was higher than the previous result while the sound of knocks was coincided. The range of frequency variation for the sound of bong, pluses and chirps was 34${\sim}$213Hz, 75${\sim}$360Hz and 120${\sim}$200Hz, respectively and the average of lasted time was 84msec, 873msec and 80msec, respectively.

Investigation of the Noise Reduction in the Hollow Cylinder Structure (중공 원통형 구조물의 전달소음 감소 방안 연구)

  • Lee, Sang-Won;Lee, Jong-Kil;Jo, Chi-Yong
    • 대한공업교육학회지
    • /
    • v.36 no.1
    • /
    • pp.115-130
    • /
    • 2011
  • When the hollow cylinder structure moves in underwater with high speed structural can be propagated from the end of the structure to the front side. This noise can reduce the sensitivity of the conformal array which installed in the surface of the cylinder. To reduce this noise propagation it is suggested to install two self-reduction rings at the surrounding of the cylinder which is 500mm in diameter and 840mm in length. The places of the two noise reduction rings are 120mm and 240mm point from the end of the structure. Two noise reduction rings reduced 10.1 % of maximum stress. When outside noise frequency applied to the structure from the 4kZ to 6kHz, 20dB noise reduction was calculated using 6 order polynomial equation. When outside noise frequency also applied to the structure with 200Hz, 500Hz, 900Hz, maximum sound pressure level point moved to the end of the structure. Most conformal sensors are fabricated at the front side of the structure. Based on the simulation results proposed two rings can be reduced noise propagation from the tail of the structure effectively.

A 1V Analog CMOS Front-End for Cardiac Pacemaker Applications (심장박동 조절장치를 위한 1V 아날로그 CMOS 전단 처리기)

  • Chae, Young-Cheol;Lee, Jeong-Whan;Lee, In-Hee;Han, Gun-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • A low-voltage, low-power analog CMOS front-end for a cardiac pacemaker is proposed. The circuits include a 4th order switched-capacitor (SC) filter with a passband of 80-120 Hz and a SC variable gain amplifier whose control range is from 0 to 24-dB with 0.094 dB step. An inverter-based switched-capacitor circuit technique is used for low-voltage operation and ultra-low power consumption, and correlated double sampling technique is used for reducing the finite gain effect of an inverter. The proposed circuit has been designed in a $0.35-{\mu}m$ CMOS process, and it achieves 80-dB SFDR at 5-kHz sampling frequency. The power consumption is only 330 nW at 1-V power supply.

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

Development of Vibration Absorption Device for the Transportation-Trailer System(II) - Connecting Hitch for Power Tiller-Trailer - (수송 트레일러의 충격흡수장치 개발(II) - 동력경운기 연결 히치 -)

  • Hong J. H.;Lee H. J.;Lee S. B.;Park W. Y.;Kim S. Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.147-154
    • /
    • 2005
  • The improved hitch device, which connecting the trailer to power tiller, was developed. This device, composed with spring and rubber, could reduce the vibration and shock levels during driven on off-road. The vertical vibration accelerations for the improved hitch device were measured at 6 positions, i.e. engine, hitch, seat, and three points in trailer (front, middle, and rear) for not driving but at low engine speed of 500 rpm, and compared with the existing hitch device. The results of this study could be summarized as follows; The average vibration acceleration up to 120 Hz was $0.4m/s^2$ at engine part, but it was 0.08 and $0.05m/s^2$ at trailer for existing and improved hitch device, respectively. About $38\%$ of average acceleration level could be absorbed for the improved hitch device compared with existing hitch device. The average vibration acceleration up to 40 Hz was reduced to 0.12 and $0.06m/s^2$ at trailer for existing and improved hitch device respectively, showing the reduction effect of $50\%$. The maximum acceleration occurred at up to 20 Hz of low frequency was much higher than total acceleration occurred at up to 120 Hz, which means that much loss or damage could be occurred during transporting of agricultural products on off-road. The portions of average acceleration occurred at up to 20 Hz of low frequency were $27\%\;and\;21\%$ for the existing and improved hitch device, respectively.

Vibration Measurements of Large-Scale Structure Using Laser and High-Speed CCD Camera (레이저와 고속 CCD 카메라를 이용한 대형구조물의 진동계측)

  • 이창복;안세호;양성훈;염정원;강동욱;김기두
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1104-1112
    • /
    • 2004
  • In this paper, we establish measurement methods of vibration frequency for three-dimensional behavior measurement of large-scale structure using laser and high-speed CCD camera. We project the diode laser having a smaller fluctuation on the object plane attached to the structure and measure the displacement of the structure using a precise relative measurement algorithm. When we use high-speed(120 frames/sec) CCD camera, we can measure the vibration frequency having the uncertainty within 0.5% by taking FFT on the displacement, from 0Hz to 40Hz. And we also confirm the reliability and economical string of the suggested measurement method of vibration frequency of the structure by showing the accuracy of displacement measurement using laser is comparable to that of relative positioning methods using GPS.

The Case Study of The Generator Noise generated by Stator Looseness (발전기 고정자 이완에 의한 소음발생 고찰)

  • Yoo, Mu-Sang;Han, Seung-Woo;Roh, Cheol-Woo;Ryu, Kil-Su;Oh, Seung-Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.527-532
    • /
    • 2014
  • Generator is the main equipment of a power plant that generates electric power. The line frequency is 60Hz, since that is operated at 3600rpm in fossil power plant. Therefore, the specific frequency 120Hz by the electromagnetic excitation force is generated inherently. If the looseness of stator at generator happens, abnormal sound that has 120Hz and the harmonic frequency is emitted from generator frame. In that case, binding of end-winding or re-wedging is needed for the reduction of sound level. In case of severe level of sound, belly band can be additionally installed at core. In this paper, the characteristics of generator sound is described and modal data is analyzed after installation of belly band.

  • PDF

Energy Generator using Piezoelectric Multilayer Device (적층 압전 소자를 이용한 에너지 발생장치 제작 및 성능)

  • Jeong, Soon-Jong;Kim, Min-Soo;Lee, Dae-Su;Kim, In-Sung;Joo, Hyeon-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.166-166
    • /
    • 2009
  • 에너지 하베스팅 소자용 압전 적층체를 제작하고 이에 대한 성능을 조사하였다. 최근 대부분 소형 소자들을 구동하는데 있어서 이에 필요한 소비 전력은 최소한 10~20 mW 이다. 이에 적합한 mm 크기의 압전 소자를 제작하고 외부 금속 기구물을 연결한 하베스팅 소자를 제작하였다. 이러한 소자의 공진 주파수를 120 Hz로 정하고 이에 적합한 무게추를 설정하였다. 120 Hz에서 1 g 가속도로 외부에서 진동을 가했을 때, 소자는 5 V, 20 mW의 전력을 발생하였다. 또한 이러한 소자에서 발생된 전력을 저장하기 위하여 간단한 정류 및 저장 장치를 제작하였다. 회로 제작시 압전 소자의 임피던스가 매우 적으므로 이에 적합하게 임피던스 매칭을 고려한 저 임피던스 회로를 제작하였으며, 이 회로는 약 80%의 효율을 나타내었다.

  • PDF

Flicker Prevention and Noise Reduction Using Edge-Spike Modulation in Visible Light Communication

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.143-149
    • /
    • 2018
  • In this paper, we introduce an edge-spike modulation method for visible light communication (VLC). This method is effective in preventing LED flicker and 120 Hz noise interference in base-band VLC. In the VLC transmitter, edge-spikes are generated by passing the digital data through a simple RC-high pass filter (HPF). The LED modulation of the edge-spikes does not change the average power of the LED light; thus it prevents LED flicker. In the VLC receiver, the 120 Hz noise from other lighting lamps is easily eliminated by RC-HPF, while the edge-spike signal is detected normally. In our experiment, the message of an air-quality sensor was successfully transmitted using edge-spike modulation. This structure is useful in constructing, e.g., wireless gas monitoring sensor systems to warn and prevent harmful gas leakage accidents in buildings using LED light.

A study on the structure-vibration analysis of power transformer(154kV Single Phase) (전력용 변압기(154kV 단상)의 구조진동 해석에 관한 연구)

  • Kim, Young-Dal;Park, Woo-Yong;Kim, Seun-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.203-206
    • /
    • 2008
  • 전력용 변압기의 고장 원인이 과도 진동에 의한 기계적 결함이 대부분을 차지하고 있으며, 그 원인 120Hz배수 조합으로 이루어진 진동이다. 전력용변압기에 작용되는 기계적 가진력을 유형별로 분류하고, 기계나 구조물에 미치는 진동전달 경로를 통해 전력용변압기의 기계적 손상 메커니즘을 규명한다. 일반적으로 120Hz 성분의 진동이 변압기변의 외함, 부싱, 부흐홀쯔, 방압변 및 탭체인쳐의 진동영향에 대해 확인하였다.

  • PDF