• Title/Summary/Keyword: 120Hz

Search Result 486, Processing Time 0.024 seconds

Modal Analysis and FEA of a Compressor Motor for 120Hz Resonance Reducing (컴프레서용 모터 120Hz 공진 저감을 위한 연구)

  • Shin, Hyun-Jang
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.81-87
    • /
    • 2017
  • 315Fr compressor motor exceeds vibration specifications. To find the reason, first a modal impact test with free-free condition is done. Second a modal test with fixed condition is done. Thereafter the test results are compared with FEM simulation results. Using free-free condition modal impact test, FEM simulation conditions (boundary, mesh..) are modified. The motor has rolling motion around 120Hz. FEM simulation also shows same result. FEM simulation will be used to develop other series compressor motors. Using this, manufacturing test model and doing test will be useless.

A study on calibration for commercial split beam echosounder using the bottom backscattering strength from a fishing vessel near the South Shetland Islands, Antarctica (남극 남쉐틀랜드 군도 주변 해저면 음향신호를 이용한 상업용 어군탐지기 보정 연구)

  • CHOI, Seok-Gwan;LEE, Hyungbeen;LEE, Kyounghoon;LEE, Jaebong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.4
    • /
    • pp.318-324
    • /
    • 2016
  • Commercial split beam echosounder (ES70) installed on a krill fishing vessel was calibrated in order to utilize it in estimating biomass of Antarctic krill (Euphausia superba). The method of calibration was to analyze the difference between the bottom backscattering strength of the commercial split beam echosounder (i.e. ES70) and the scientific echosounder (i.e. EK60) at one of transects near South Shetland Islands designated by CCAMLR. 38 kHz and 120 kHz were used for the calibration, and krill swarm signal levels obtained from multi frequencies, was examined to verify the calibration result. The analysis result indicated possibility of calibration by bottom backscattering strength, since the proportion of krill swarm signals within 2 dB < $S_{V\;120\;kHz-38\;kHz}$ < 12 dB (i.e. a common $S_{V\;120\;kHz-38\;kHz}$ range of 38 kHz and 120 kHz to be an indicator of Antarctic krill) over the total acoustic signals were 26.95% and 92.04%, respectively before and after the calibration.

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(II) : Analysis of Membrane Materials, Solutes and Multi-ultrasonic Effect (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(II) : 막의 재질, 용질과 복합초음파의 효과 분석)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on reducing membrane fouling for the treatment of chemically treated leachate and biologically treated leachate. The experiments on improvement of membrane flux according to the membrane types(MF and UF) and membrane materials were performed with changing frequency(40 kHz and 120 kHz) and intensity(200 W and 400 W) of ultrasound in ultrasonic membrane separation apparatus which ultrasound can be periodically irradiated. Additionally, the effect of dual frequency ultrasound which 40 kHz md 120 kHz are irradiated simultaneously was evaluated. The improvement of membrane flux by periodical ultrasound irradiation was higher in microfiltration(MF) membrane than in ultrafiltration(UF) membrane. It was sustained more in the MF membrane of polyvinylidene fluoride(PVDF) than in that of polysulfon(PS). Ultrasonic improvement of membrane flux was different depending on the characteristics of target wastewater. It was sustainably maintained without reclogging using dual frequency ultrasound although the improvement of membrane flux was lower.

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

A Time-multiplexed 3d Display Using Steered Exit Pupils

  • Brar, Rajwinder Singh;Surman, Phil;Sexton, Ian;Hopf, Klaus
    • Journal of Information Display
    • /
    • v.11 no.2
    • /
    • pp.76-83
    • /
    • 2010
  • This paper presents the multi-user autostereoscopic 3D display system constructed and operated by the authors using the time-multiplexing approach. This prototype has three main advantages over the previous versions developed by the authors: its hardware was simplified as only one optical array is used to create viewing regions in space, a lenticular multiplexing screen is not necessary as images can be produced sequentially on a fast 120Hz LCD with full resolution, and the holographic projector was replaced with a high-frame-rate digital micromirror device (DMD) projector. The whole system in this prototype consists of four major parts: a 120Hz high-frame-rate DMD projector, a 49-element optical array, a 120Hz screen assembly, and a multi-user head tracker. The display images for the left/right eyes are produced alternatively on a 120Hz direct-view LCD and are synchronized with the output of the projector, which acts as a backlight of the LCD. The novel steering optics controlled by the multiuser head tracker system directs the projector output to regions referred to as exit pupils, which are located in the viewers’eyes. The display can be developed in the "hang-on-the-wall"form.

Design and Electromagnetic Characteristics of Planar Transformer (평면변압기의 설계와 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yeon;Kim, Jong-Ryung;Oh, Young-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.109-116
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8 W capacity, with 70 V input voltage and 8.2 V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 $\mu$H, which was the inductance efficiency of'85∼87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 Ω and 0.25 Ω respectively, On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96∼0.97 under 120 kHz switching frequency. The inductance rapidly increased as the thickness of the core plane increased until it became 1.4 mm but under the thickness more than 1.4 mm, there was no substantial change. Therefore, the critical value of the plane thickness of core was 1.4 mm. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

Morphological Properties and Target Strength Characteristics for dark banded rockfish (Sebastes inermis) (볼락의 형태학적 특징과 음향반사강도 특성)

  • Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • Morphological properties of dark banded rockfish (Sebastes inermis) were analysed to investigate its acoustic scattering characteristics. Total of 18 live samples was prepared for X-ray photos and collected morphological coordinates of their body and swim bladder shapes. Kirchhoff-ray mode model was used to calculate acoustic scattering pattern for broad-band frequency range. Inclination of swim bladder ranged from 17 to 30 and the averaged value was about $25.2^{\circ}$ (S.D.(standard deviation)=3.15). There were no any tendency of increase or decrease in volume and area ratio of swim bladder to fish body and ranged from 2.2 % to 4.43 % and 14.85 % to 21.31 %, respectively. The averaged value of volume and area ratio was 3.13 % (S.D.=0.52) and 17.6 % (S.D.=1.5). $b_{20}$ values were -69.01 for 38 kHz, -69.83 for 70 kHz, -70.17 for 120 kHz and -70.93 for 200 kHz, recpectively. Broadband acoustic patterns of dark banded rockfish for 20 ~ 200 kHz were similar among samples and they reflected size and morphological properties of fish species.

In situ behavioral and acoustic characteristics of the large jellyfish Nemopliema nomurai by target tracking (수중음향을 이용한 노무라입깃해파리의 행동 및 음향산란특성)

  • Yoon, Eun-A;Hwang, Doo-Jin;Shin, Hyeong-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.2
    • /
    • pp.272-278
    • /
    • 2015
  • The aim of this study is to find out the behavior and acoustic backscattering of the large jellyfish Nemopliema nomurai using hydroacoustics in situ. N. nomurai was distributed at depths ranging from 10~15 m during the day. Regarding the behavior of N. nomurai, there was no significant change in depth, and 3D tortuosity was not high. The vertical direction was ${\pm}10^{\circ}$ from the horizontal, and moving speed was $0.9{\sim}1.5\;m\;s^{-1}$. With regard to hydro-acoustical characteristics, the mean TS of N. nomurai ranged from -69.6~-56.0 dB at 38 kHz and -69.4~-54.5 dB at 120 kHz. TS variation (Max TS-Min TS) at 38 and 120 kHz was 0~10.2 dB and 0.2~16.0 dB, respectively. Mean TS and TS variation (Max TS-Min TS) of N. nomurai were higher at 120 kHz than at 38 kHz. The results showed that the use of hydroacoustics was effective in estimating the distribution depth, behavior, and acoustic characteristics of the target.

Acoustic scattering characteristics of chub mackerel (Scomber japonicus) by KRM model (KRM 모델을 이용한 고등어(Scomber japonicus)의 음향산란특성 규명)

  • PARK, Geunchang;OH, Wooseok;OH, Sunyoung;LEE, Kyounghoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.1
    • /
    • pp.32-38
    • /
    • 2022
  • In this study, Target strength for multi-frequency (38 kHz, 70 kHz, 120 kHz and 200 kHz) of chub mackerel (Scomber japonicus) was estimated using by the KRM model. The body shape of the Chub mackerel was described by an X-ray system and the body length of 20 individuals ranged from 16 cm to 28 cm. The swimbladder tilt angle ranged between -8 and -14°, the maximum TS value according to the swimming angle of chub mackerel was -33.0 dB at -11°. The averaged TScm according to fork length was -66.02 dB at 38 kHz, -66.50 dB at 70 kHz, -66.00 dB at 120 kHz and -67.35 dB at 200kHz, respectively.

Study on PWM Converter Control under Unbalanced Network Condition

  • Sastrowijoyo, Fajar;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.524-526
    • /
    • 2011
  • This paper focuses on study on PWM converter control under unbalanced network condition. Voltage unbalance in a three-phase system causes the performance deterioration by producing 120 Hz voltage ripples in the DC link and 120 Hz ripple in reactive power. To eliminate the ripples, both positive and negative sequence currents should be controlled simultaneously. In this paper four PI controllers on synchronous reference frame is implemented to control D and Q currents in both positive and negative sequence. Positive and negative sequence signal extraction is done using delay signal cancellation method. Simulation results show satisfactory performance in suppressing 120 Hz ripples.

  • PDF