• Title/Summary/Keyword: 120 GeV

Search Result 16, Processing Time 0.025 seconds

Fabrication and characterization of the SiGe HBTs using an RPCVD (RPCVD를 이용한 실리콘 게르마늄 이종 접합 바이폴라 트랜지스터 제작 및 특성 분석)

  • 한태현;서광열
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.823-829
    • /
    • 2004
  • In this paper, non-self-aligned SiGe HBTs with ${f}_\tau$ and${f}_max $above 50 GHz have been fabricated using an RPCVD(Reduced Pressure Chemical Vapor Deposition) system for wireless applications. In the proposed structure, in-situ boron doped selective epitaxial growth(BDSEG) and TiSi$_2$ were used for the base electrode to reduce base resistance and in-situ phosphorus doped polysilicon was used for the emitter electrode to reduce emitter resistance. SiGe base profiles and collector design methodology to increase ${f}_\tau$ and${f}_max $ are discussed in detail. Two SiGe HBTs with the collector-emitter breakdown voltages ${BV}_CEO$ of 3 V and 6 V were fabricated using SIC(selective ion-implanted collector) implantation. Fabricated SiGe HBTs have a current gain of 265 ∼ 285 and Early voltage of 102 ∼ 120 V, respectively. For the $1\times{8}_\mu{m}^2$ emitter, a SiGe HBT with ${BV}_CEO$= 6 V shows a cut-off frequency, ${f}_\tau$of 24.3 GHz and a maximum oscillation frequency, ${f}_max $of 47.6 GHz at $I_c$of 3.7 mA and$V_CE$ of 4 V. A SiGe HBT with ${BV}_CEO$ = 3 V shows ${f}_\tau$of 50.8 GHz and ${f}_max $ of 52.2 GHz at $I_c$ of 14.7 mA and $V_CE$ of 2 V.

Vacuum System Design of the PLS 2 GeV Linac (PLS 2 GeV 선형가속기의 진공계통 설계)

  • 김임경;오형석;이인준;박주식;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.1
    • /
    • pp.17-22
    • /
    • 1993
  • 본 논문은 포항가속기연구소에서 건설중인 PLS 2 GeV 선형가속기 진공계통의 설계에 관한 것이다. PLS 2GeV 선형가속기의 진공계통은 길이 3.07m인 42개의 가속관과 길이 약 400m의 도파관으로 구성되어 있다. 진공장치의 배치는 충분한 지역적 배기능력을 고려한 분산 배기방식으로 다지관 방식의 기계적 복잡성을 단순화하였다. 진공계는 가속관 중심과 도파관에서 5$\times$10-7Torr, 클라이스트론 출력장치에서 5$\times$10-8Torr까지 배기되도록 설계하였다. 주 진공펌프로는 가속관과 도파관 및 에너지 배가장치에 대하여 각각 용량이 60l/s와 120l/s인 sputter 이온펌프를 사용하기로 하였다.

  • PDF

THERMOLUMINESCENCE DOSIMETRIC PROPERTIES OF Ge- AND Er-DOPED OPTICAL FIBRES AND THEIR APPLICATION IN THE MEASUREMENT OF DEPTH -DOSE IN SOLID WATER PHANTHOM

  • Amin, Y.M.;Abdulla, Y.A.;Khoo, B.H.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.143-147
    • /
    • 2001
  • The dosimetric properties of Ge- and Er-doped optical fibres are studied. The Ge-doped fibre is found to be more sensitive to radiation and there is little fading of TL signal compared with Er-doped fibre. The Ge- and Er-doped fibres showed a linear response over a range of ${\sim}1\;Gy$ to about 120 Gy and ${\sim}1Gy$ to about 250Gy respectively. The Ge-doped fibre is found to be dose-rate independent both for photons and electron beams of energy ranging from 6 to 10 MeV and 6 to 12 MeV respectively. The fibre is energy independent for energy greater than ${\sim}0.1\;MeV$ for photon or 0.1 MeV for electron beam. From the depth-dose measurement, it was found that the position of maximum dose, dmax, increased with increasing energy ranging from ${\sim}2\;cm$ and ${\sim}2.5\;cm$ for 6 MeV and 10 MeV photons respectively. The central axis percentage depth dose at 10 cm depth was found to be in good agreement with the value obtained using ionization chamber.

  • PDF

Magnetoresistance and Hall coefficient in $V_xGe_{l-x}$ single crystal (VGe 단결정의 자기저항과 홀 계수)

  • Park, Jiyoun;Park, Sungyoul;Park, Jeongyong;Hong, Soon-Cheol;Sunglae Cho;Park, Yongsup;Lee, Gu-Won;Park, Hyun-Min;Kim, Y. C.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.154-155
    • /
    • 2003
  • Substituting transition metals such as V, Cr, Mn, Fe, Co and Ni into semiconductors have been of interest because of its unique electrical and magnetic properties. It was reported that the magnetoresistance(MR) ratio of CrGe was 1.7% and 1 4% at 120 K in fields of 0.5 and 5 T, respectively. The MR ratio of FeGe was 19% at 180K. The electrical resistivity of CrGe changed according to Cr concentration. In this talk, we report transport properties of V-doped Ge single crystals with several different V concentrations. The carrier densities and mobilities will be determined from Hall measurement.

  • PDF

JASMIN: Shielding Studies on High Energy Neutron Produced By 120 GeV Protons

  • Lee, Hee-Seock;Sanami, Toshiya;Iwamoto, Yosuke;Kajimoto, Tsuyoshi;Shigyo, Nobuhiro;Saito, Kiwamu;Hagiwara, Masayuki;Yashima, Hiroshi;Kasugai, Yoshimi;Ramberg, Erik;Coleman, Richard;;Meyhoefer, Aria;Mokhov, Nikolai V.;Leveling, Anthony F.;Boehnlein, David J.;Vaziri, Kamran;Sakamoto, Yukio;Nakashima, Hiroshi
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.94-95
    • /
    • 2010
  • The accuracy of typical dosimeters used around high energy accelerator were proved by dose rate measurements. The experimental neutron spectrum were useful for improving high energy Monte Carlo codes by validating the implemented models. In series of this joint research the experimental data will be upgrade successively. This research program is opened to experts and students in Korea, too.

  • PDF

The study of phase-change with electric field on chalcogenide thin films (칼코게나이드 박막의 전기적 펄스에 의한 상변화 특성 연구)

  • Yang, Sung-Jun;Shin, Kyung;Lee, Ki-Nam;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.120-122
    • /
    • 2003
  • We have been investigated phase-change with temperature and electric field in chalcogenide $Ge_2Sb_2Te_5$ thin film. $T_c$(crystallization temperature) is confirmed by measuring the resistance and conductivity with the varying temperature on the hotplate. We have measured I-V characteristics with $Ge_2Sb_2Te_5$ chalcogenide thin film. It is compared with I-V characteristics after impress the variable pulse. The pulse has variable height and duration that used voltage and current source.

  • PDF

KLYSTRON-MODULATOR SYSTEM PERFORMANCES FOR PLS 2-GeV LINAC (포항 20억 전자볼트 선형가속기 클라이스트론-모듈레이터 시스템의 성능)

  • Park, S.W.;Park, S.S.;Lee, K.T.;Oh, J.S.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1365-1367
    • /
    • 1995
  • The PLS 2-GeV linac employs 11 units of high-power pulsed klystrons(80MW) as the main RF sources. The matching modulators of 200 MW(400kV, 500 A) can provide a flat-top pulse width of 4.4 ${\mu}s$ with a maximum pulse repetition rate of 120 Hz at the full power level. For a good stability of electron beams, the pulse-to-pulse flat-top voltage variation of a modulator requires less than 0.5%. In order to achieve this goal, we stabilized high voltage charging power supplies within 1% by a phase controlled SCR voltage regulator. In addition, we employed ac/dc feedback together with a resistive De-Q'ing system to achieve far less than 0.5% variation of the PFN charging voltage. This paper presents the main feature of the klystron-modulator system and the characteristics of the pulsed high-power RF system performance during the beam injection operation for the Pohang Light Source commissioning.

  • PDF

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Effect of Stevia rebaudiana on the Bioactive Compounds from Agarwood Leaf (Aquilaria spp.) by Lactic Fermentation and Spray Drying

  • Dong, Lieu My;Nam, Doan Trung;Phuong, Tran Thi;Thuy, Dang Kim
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • Agarwood (Aquilaria spp) has high economic value. However, essential oil production from agarwood is a time-consuming process. Additionally, agarwood leaves have not been utilized even though they contain various bioactive ingredients. In this study, agarwood leaves were fermented using Lactobacillus plantarum ATCC 8014 with or without Stevia (4, 8, and 12%; v/v). The fermented fluid was mixed with maltodextrin (15%; w/v) and subjected to spray drying (inlet temperature, 120℃; outlet temperature, 65-70℃). The contents of polyphenols, polysaccharides, saponins, and flavonoids and the viability of L. plantarum were determined. Fermentation enhanced the levels of bioactive compounds. The contents of polyphenol (69.19 ± 4.05 mg GAE/g of sample), polysaccharide (20.75 ± 0.98 mg GE/g of sample), saponin (305.23 ± 4.21 mg OAE/g of sample), and flavonoid (7.86 ± 0.72 mg QE/g of sample), and the viability of L. plantarum (8.72 ± 0.17 log CFU/ml) were markedly upregulated in the samples containing Stevia (12%; v/v). This indicated that the supplementation of Stevia during fermentation decreases the fermentation time (9 h), upregulates bioactive compound production in agarwood leaves, enhances microencapsulation during spray drying, and increases the viability of L. plantarum under simulated gastric digestion conditions.

Study on High Voltage Switch Using IGBT (IGBT를 사용한 고전압 스위치에 관한 연구)

  • Park, S.S.;Kim, S.C.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.556-558
    • /
    • 1996
  • PLS 2-GeV linac has 11 sets of high power klystron-modulator system as a main RF source for the beam acceleration. The modulators can provide 200-MW peak pulsed power(400-kV, 500-A) with a pulse width of $7.5{\mu}s$(ESW), a maximum pulse repetition rate of 120-Hz at the full power level. The DC power supply provides a 25-kV, 7-Adc and the charging system consists of a charging inductor, charging capacitor, and the diode for reverse current protection. The charged PFN voltage by a LC resonant charging method has two times of the DC high voltage and the pulsed power is delivered to the load by a thyratron switch. To reduced the press of high voltage lit thyratron switch, the command charging is the best method. In this article, the high voltage switch for the command charging method is tested to the start work and the system is presented with the experiment results of the trigger and operational characteristics.

  • PDF