• Title/Summary/Keyword: 12/14 pole

Search Result 21, Processing Time 0.034 seconds

Design and Analysis of Novel 12/14 Hybrid Pole Type Bearingless Switched Reluctance Motor with Short Flux Path

  • Xu, Zhenyao;Zhang, Fengge;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.705-713
    • /
    • 2012
  • In this paper, a novel 12/14 hybrid pole type bearingless switched reluctance motor (BLSRM) with short flux path and no flux-reversal in the stator is proposed. The proposed BLSRM has separated rotating torque and suspending force poles. Because of independent characteristics between torque and suspending force poles, the torque control can be decoupled from the suspending force control. Due to the short flux path without any reversal flux, compared to the 8/10 hybrid stator pole BLSRM, the output torque is significantly improved and the air-gap is easier to control. Meanwhile, basic design principle for the proposed structure is described. To verify the proposed structure, finite element method (FEM) is employed to get characteristics of the proposed structure and 8/10 hybrid stator pole BLSRM. Based on the analysis, a prototype of the proposed BLSRM is designed and manufactured. Finally, validity of the proposed structure is verified by the experimental results.

Analysis and Design of 12/14 Bearingless Switched Reluctance Motor for Self-Starting and Torque Ripple Reduction (자기기동 및 토크리플 저감을 위한 12/14 베어링리스 SRM의 설계 및 특성해석)

  • Xu, Zhenyao;Lee, Dong-Hee;An, Young-Ju;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.682-684
    • /
    • 2015
  • A 12/14 bearingless switched reluctance motor (BLSRM) with hybrid stator poles has been proposed due to the outstanding decoupling characteristics between the torque and suspending force. However, the motor is a two-phase motor. The output torque of the motor has torque dead zone and high torque ripple. Hence, the motor cannot self-start at some rotor positions. To solve the self-starting problems and reduce the torque ripple, a stepped rotor is proposed in this paper. Then, the motor with the stepped rotor is optimally designed. In the new designed motor, the majority parameters are kept the same with those of original motor; only the torque pole arc and rotor pole shape are optimally designed. The characteristics of the redesigned motor, such as inductance, torque and suspending force, are analyzed and compared with those in the original motor. Finally, the effectiveness of the proposed method is verified by the simulation results.

  • PDF

Individual and Global Optimization of Switched Flux Permanent Magnet Motors

  • Zhu, Z.Q.;Liu, X.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.1
    • /
    • pp.32-39
    • /
    • 2012
  • With the aid of genetic algorithm (GA), global optimization with multiple geometry parameters is feasible in the design of switched flux permanent magnet (SFPM) machines. To investigate the advantages of global optimization over individual optimization, which has been used extensively for the design of SFPM machines, a comparison between the two approaches is carried out for the case of fixed copper loss and volume. In the case of individual parameter optimization, the sequence in which the individual parameters are optimized is very important. In the global optimization a better design can always be achieved although the corresponding torque density is found to be only slightly better than that of individually optimized with correct design sequence. By using the obtained global optimization results, the performance in machines having two types of stator and rotor pole combinations, i.e. 12/10 and 12/14, are compared, and it is shown that higher torque is exhibited in the 12/14 SFPM machine. Finally, this paper also demonstrates that global optimization, with the restriction of equal pole width, magnet thickness and slot opening, can maximize the torque density without significantly sacrificing other performance, such as cogging torque and overload capability.

Practical Study on Adjustment of Load Correlation Equations of Pole Transformer (주상변압기 부하 상관식 조정에 관한 실증적 연구)

  • 박창호;김두봉;김기현;배주천;윤상윤;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.102-108
    • /
    • 2000
  • This paper presents a result of practical study about the adjustment of load correlation equation for the load management of pole transformer. For adjusting the load correlation equation, we analyze the correlative relation between working electric energy[kWh] and peak load[A]. To enhance the accuracy of correlation equation, we classify the 12 representative area patterns. And then, we select the 24 sample pole transformer for each area pattern. For the reliability of the data using the load correlation equation, load management equipment is utilized for each sample pole transformer. Through the on-line data acquisition, we construct the database. For adjusting the load correlation equation, we consider the two points. One is the goodness of fitness for load correlation equation and the other is prevention of pole transformer damage due to the overload. Finally, we propose the correlation equation using the linear and quadratic equation all at once. Through the case studies, we verify that the proposed load correlation equation is reduced the error ratio than conventional correlation equation.

  • PDF

Study on the Combination of the Number of Pole and Slot of IPMSM for Vibration Reduction of Electromagnetic Force Fundamental Harmonic Component (전자기력의 기본파 성분 진동저감을 위한 IPMSM의 극 수 슬롯 수 조합에 대한 연구)

  • Shin, Chang-Wook;Son, Hyung-Soo;Yoon, Myung-Hwan;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.726-727
    • /
    • 2015
  • 본 논문은 IPMSM(Interior Permanent Magnetic - Synchronous Motor) 구동 시에 나타나는 전자기력의 기본파 성분의 진동을 분석하였다. 대상 전동기로는 크기가 같고 동일 출력을 내는 14극 12슬롯, 14극 18슬롯 IPMSM을 선정하였다. 두 전동기의 Vibration Order를 수식적으로 검토한 결과 14극 12슬롯 전동기가 14극 18슬롯 전동기에 비해 전자기력의 기본파 성분이 진동에 취약함을 확인하였고, 이를 유한요소해석(FEA)을 통해 검증하였다. 검토결과를 바탕으로 전자기력의 기본파 성분 진동저감을 위한 극 수 슬롯 수 조합에 대해서 분석하였다.

  • PDF

Primary Hyperparathyroidism due to Parathyroid Adenoma (부갑상선 선종에 의한 원발성 부갑상선 기능 항진증)

  • Park, Woo-Hyun;Bae, Byung-Jin;Choi, Soon-Ok
    • Advances in pediatric surgery
    • /
    • v.6 no.1
    • /
    • pp.68-69
    • /
    • 2000
  • A case of primary hyperparathyroidism due to parathyroid adenoma is presented. A 14 year-old male was admitted to the hospital comptaining of voiding difficulty. The intravenous pyelogram demonstrated a stone in the proximal one third of the left ureter and marked hydronephrosis of the left kidney. The Tc-99m sestamibi nuclear scan demonstrated a hot spot below the lower pole of the left lobe of the thyroid. Laboratory study demonstrated hypercalcemia (12.4 mg/dL) and elevated parathyroid hormone (143.67 pg/mL). A parathyroid gland located below the lower pole of the left lobe of the thyroid was excised. A parathyroid adenoma, consisting of mainly chief cells was found on pathologic examination. Postoperatively the patient had transient hypocalcemic symptoms, which resolved with administration of calcium preparation and vitamin D.

  • PDF

Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter (중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구)

  • Nam-Koong, Hyuk;Oh, Shin Hyun;Kim, Jung Yul;Choi, Yoon Jung;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • Purpose: A duplicated ureter is congenital renal malformations with ureter in two. Patients with duplicated ureter are in force to $^{99m}Tc-DMSA$ scan at surgery before and after. In existing examination, at produce result after $^{99m}Tc-DMSA$ scan, didn't compare to upper pole and lower pole with malformed kidney and compared to only relative uptake ratio. Therefore, this study will examine about utility of set a partial region of interest and to functional recovery of renal cell through change of upper pole uptake ratio of malformed kidney by setting each partial region of interest in upper pole and lower pole of malformed kidney in $^{99m}Tc-DMSA$ examination in surgery before and after. Materials and Methods: Pediatric patients with malformed kidney of incomplete duplicated ureter, 15 patients were enrolled in this study. Scanning were scan 3 to 4 hours after injection of $^{99m}Tc-DMSA$ 1.5 ~ 1.9 MBq/kg. Region of interest were each set in normal kidney, upper pole and lower pole with malformed kidney. Region of interest were set with same condition and method to images of surgery before and after that radio technologist 1 person, resident of nuclear medicine 1 person and doctor of urology together. Therefore, this study were compared to uptake ratio (A: B: C) that normal kidney (A), lower pole of malformed kidney (B) and upper pole of malformed kidney (C) about uptake ratio changes of malformed kidney in follow-up examination of surgery before and after. Results: When compared to 15 patients, uptake ratios were increased 7 persons and decreased 8 persons. Among increased 7 persons, it were periods of follow-up examination that 2 persons were 14 months, 4 persons were 12 months and 1 person was 8 months after surgery. Among decreased 8 persons, it were periods of follow-up examination that 4 persons were 12 months 3 persons were 6 months and 1 persons were 4 months after surgery. Conclusion: Existing study could not see the exact uptake ratio changes of malformed kidney because using only the overall Left-Right kidney uptake ratios. But a setting partial region of interest was able to see exactly what changes in the uptake of each upper pole and lower pole of malformed kidney. Because recovery of renal parenchymal cells is difficult in an evaluation of short period of time, follow-up examination should be made in long period of time. How to set up partial region of interest be thought that it would be useful.

  • PDF

The Development of Y-type Steel Pole for Distribution Facilities (배전용 Y형 강관전주 개발)

  • Oh, Jae-Hyung;Ahn, Chang-Ho;Kim, Jun-Oh;Jang, Jin-Woo;Lee, Heung-Jae;Yi, Sue-Muk;Lee, Seung-Hee;Kwon, Tae-Joon;Kim, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.12-14
    • /
    • 2008
  • 부하가 밀집된 도심지의 배전전주는 고저압 배전선로용은 물론 주상변압기, 개폐기 등 배전기기의 설치를 위하여 필요불가결한 설비 중의 하나이다. 그러나 도심지에서는 미관저해 및 건물의 가치하락을 우려하는 민원으로 인하여 신규 건주에 어려움을 쥐고 있다. 본 연구에서는 이러한 문제점을 해결하고자 일반전주의 2배인 최대 6대의 주상변압기, 2대의 개폐기 및 특고압 인입설비를 설치할 수 있도록 2개의 상부 구조를 가지는 Y형 강관전주를 개발하였다.

  • PDF

Suspending Force Control of 12/14 BLSRM Using Fuzzy Logic Controller (퍼지 논리 제어기를 사용한 축방향지지력 제어)

  • He, Yingjie;Zhang, Fengge;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.845-847
    • /
    • 2015
  • A suspending force control based on fuzzy logic control is proposed to apply on a novel hybrid bearingless switched reluctance motor(BLSRM) which has separated torque and suspending force pole. Due to the unique structure, the suspending force control system can be easily decoupled from torque control system. In this paper, two fuzzy controller targeted at x-axis direction and y-axis direction are adopted to maintain the shaft at center position, which is very necessary for stable operation of BLSRM. By replacing the traditional PI block with modified fuzzy logic controller, the suspending system can behave a good performance, and the proposed scheme can be verified by simulation results.

  • PDF

Analysis of Radiofrequency Ablation of Small Renal Tumors in Patients at High Anesthetic and Surgical Risk: Urologist Experience with Follow-up Results in the Initial Six Months

  • Yuksel, Mehmet Bilgehan;Karakose, Ayhan;Gumus, Bilal;Tarhan, Serdar;Atesci, Yusuf Ziya;Akan, Zafer
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6637-6641
    • /
    • 2013
  • Background: To evaluate the results of various types of radiofrequency ablation (RFA) treatment of renal tumors in patients with excessive anesthetic and surgical risk. Materials and Methods: Data for RFA performed in in high risk patients were retrospectively evaluated. Other RFA applications in patients with no anesthetic and/or surgical risk were excluded. RFA was by ultrasound or CT guided percutaneous (USG/CT-PRFA) and retroperitoneally or transperitoneally laparoscopic (R/T-LRFA) techniques under general or local anethesia. Follow-up data of enhanced CT or MRI after 1, 3 and 6 months were analysed for twelve RFA applications. Results: The RFA applications included 4 (40%) left-sided, 5 (50%) right-sided and 1 (10%) bilaterally RFA (simultaneously 1 right and 2 left). The localizations of tumors were 2 (16.6%) upper, 5 (41.6%) mid and 5 (41.6%) lower pole. The RFA applications included 9 (75%) USG-PRFA, 1 (8.3%) CT-PRFA, 1 (8.3%) T-LRFA and 1 (8.3%) R-LRFA. The mean age was $65.3{\pm}8.5$ (52-76) years. The mean tumor size was $29.6{\pm}6.08$ (15-40) mm. No complications related to the RFA were encountered in any of the cases. Failure (residual tumour) was determined in 8.3% (1/12) of USG-RFA application. The success rate was thus 91.7% (11/12). Other 1st, 3rd and 6th months follow-up data revealed no residua and recurrence. Conclusions: RFA application appears to be safe as a less invasive and effective treatment modality in selected cases of small renal tumors in individuals with excessive anesthetic and also surgical risk.