• Title/Summary/Keyword: 100% testing

Search Result 1,076, Processing Time 0.035 seconds

Applicability Evaluation of the Wastewater Treatment System Using Magnetic Ion Exchange Resin in the Existing Wastewater Treatment Plant (기존하수처리장에서 자성체 이온교환수지를 이용한 하수처리공정 적용가능성 평가)

  • Park, Chan G.;Kim, Hee S.;Lee, Jung M.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 2014
  • The optimal removal efficiency to develop wastewater treatment system using the magnetic ion exchange resin. The secondary sedimentation effluent of wastewater in W wastewater treatment plant located in Gyeong-gi Province was used as the influent. To compare the sedimentation effluent reacted with the magnetic ion exchange resin to the influent, the concentrations of CODmm, TN, $NO{_3}^-$-N and TP were measured. The flux of the influent and HRT were set to 250 mL/min, 10 min, respectively, and BVTR has adjusted to 200, 150, 100. The removal efficiency of CODmn, TN, $NO{_3}^-$-N and TP in the 200 BVTR from 71%, 40.37%, 46.34%, 42.03%, 150 BVTR from 55.22%, 37.83%, 50.38% 41.6% and 100 BVTR from 74%, 59.15%, 79.94%, 79.16%, respectively. The results on 200 BVTR, 150 BVTR, 100 BVTR tests show that 100 BVTR is the optimal factor capable of the highest rate of rejection of the organic material.

Mineral Contents of Edible Seaweeds Collected from Gijang and Wando in Korea (기장산과 완도산 식용해조류 중의 미네랄 함량)

  • Im, Yung-Geun;Choi, Jin-Seok;Kim, Dong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.39 no.1
    • /
    • pp.16-22
    • /
    • 2006
  • Mineral and heavy metal contents were determined in three brown edible seaweeds (sea mustard, Undaria pinnatifida; seaweed fusiforme, Hizikia fusiforme; sea tangle, Laminaria japonica) collected from Gijang and Wando in Korea, and two green seaweeds (sea lettuce, Enteromorpha prolifera; green laver, Monostroma nitidum) collected from Gijang. Seaweeds contained high proportions of ash (13.8-24.8%) and sulfate (1.08-3.25%). In brown seaweeds, ash contents (24.5-24.8%) were higher than in green seaweeds (13.8-15.2%). The differences of mineral contents were remarkable in both Gijang and Wando and in 5 various kinds of seaweeds. Brown seaweeds contained higher amounts of both macro-minerals (657-13,947 mg/100 g; Ca, Mg, Na, K) and trace elements (0.27-12.98 mg/100 g; Fe, Al, Zn, Mn, Cr, Cu, Ni), and green seaweeds also had relatively higher amounts of both macro-minerals (233-5,279 mg/100 g) and trace elements (0.26-10.61 mg/100 g).

Weak D Testing is not Required for D- Patients With C-E- Phenotype

  • Choi, Sooin;Chun, Sejong;Lee, Hwan Tae;Yu, HongBi;Seo, Ji Young;Cho, Duck
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.585-590
    • /
    • 2018
  • Background: Although testing to detect weak D antigens using the antihuman globulin reagent is not required for D- patients in many countries, it is routinely performed in Korea. However, weak D testing can be omitted in D- patients with a C-E- phenotype as this indicates complete deletion of the RHD gene, except in rare cases. We designed a new algorithm for weak D testing, which consisted of RhCE phenotyping followed by weak D testing in C+ or E+ samples, and compared it with the current algorithm with respect to time and cost-effectiveness. Methods: In this retrospective study, 74,889 test results from January to July 2017 in a tertiary hospital in Korea were analyzed. Agreement between the current and proposed algorithms was evaluated, and total number of tests, time required for testing, and test costs were compared. With both algorithms, RHD genotyping was conducted for samples that were C+ or E+ and negative for weak D testing. Results: The algorithms showed perfect agreement (agreement=100%; ${\kappa}=1.00$). By applying the proposed algorithm, 29.56% (115/389 tests/yr) of tests could be omitted, time required for testing could be reduced by 36% (8,672/24,084 min/yr), and the test cost could be reduced by 16.53% (536.11/3,241.08 USD/yr). Conclusions: Our algorithm omitting weak D testing in D- patients with C-E- phenotype may be a cost-effective testing strategy in Korea.

A FPGA Implementation of BIST Design for the Batch Testing (일괄검사를 위한 BIST 설계의 FPGA 구현)

  • Rhee, Kang-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.7
    • /
    • pp.1900-1906
    • /
    • 1997
  • In this paper, the efficient BILBO(named EBILBO) is designed for BIST that is able to batch the testing when circuit is designed on FPGA. The proposed algorithm of batch testing is able to test the normal operation speed with one-pin-count that can control all part of large and complex circuit. PRTPG is used for the test pattern and MISR is used for PSA. The proposed algorithm of batch testing is VHDL coding on behavioral description, so it is easily modified the model of test pattern generation, signature analysis and compression. The EBILBO's area and the performance of designed BIST are evaluated with ISCAS89 benchmark circuit on FPGA. In circuit with above 600 cells, it is shown that area is reduced below 30%, test pattern is flexibly generated about 500K and the fault coverage is from 88.3% to 100%. EBILBO for the proposed batch testing BIST is able to execute concurrently normal and test mode operation in real time to the number of $s+n+(2^s/2^p-1)$ clock(where, in CUT, # of PI;n, # of register, p is order # of polynomial). The proposed algorithm coded with VHDL is made of library, then it well be widely applied to DFT that satisfy the design and test field on sme time.

  • PDF

Breaking test of UHV circuit breaker by ANSI/IEEE standard (ANSI/IEEE를 적용한 초고압 차단기의 차단시험)

  • Park, Seung-Jae;Rhyou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.467-469
    • /
    • 2003
  • IEC(International Electrotechnical Commission) 62271-100 has been adopted for the design test of circuit breaker which is used as the main protecting device of power system. But, it is also necessary to separately receive the testing certificate in accordance with ANSI/IEEE standard for getting into the american market. Up to now, several domestic companies have completed the ANSI/IEEE testing in medium circuit breaker of distribution system, but they recently started the ANSI/IEEE testing in ultra high-voltage class of transmission and substation system. This paper introduces the testing techniques and its results for the making and breaking performance of 145kV, 40kA $SF_6$ gas circuit breaker which was firstly performed in KERI(Korea Electrotechnology Institute) by the ANSI/IEEE standard.

  • PDF

Study on the Hardness Measurement of Earthenware : Focusing on the Cup of the Baekje (토기의 경도측정법 연구: 백제시대 배(杯)류를 중심으로)

  • Moon, Eun-Jung;Kang, Hee-Jun;Kim, Su-Kyoung;Lee, Han-Hyoung;Hong, Jong-Ouk;Hwang, Jin-Ju
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.431-438
    • /
    • 2009
  • We have investigated the suitable measuring method and condition on the hardness testing for the earthenwares excavated from Poongnap mud castle in Hanseong Baekje period. The earthenwares which used on hardness testing have been classified according to Mohs hardness and external form and color. The Ultrasonic and Equotip testing method have used to the hardness testing on the surface of the earthenwares and the Rockwell and Micro-vickers testing methods have used to the hardness testing on the cross section of the earthenwares. As the results, the two methods applied to the surface of the earthenwares were very hard on the precise measurement and the measuring values were incompatible with the tendency classified according to Mohs hardness and external form and color. On the testing for the cross section of earthenware, the Rockwell-superficial hardness testing method was more suitable for the soft texture earthenware and highest reproducibility of the measuring value obtained at the test load and indentor are 15kgf and 1/16 “iron ball, respectively. The Micro-Vickers hardness testing method was suitable for the hard texture earthenware and highest reproducibility and accuracy of the measuring value obtained at the test load is 100gf. This results show strong possibility of progress on the classifying and comparing study for hardness of the earthenware and therefore active studies are expected on the field.

  • PDF

The Effects of the Annealing Heat Treatments and Testing Temperatures on the Mechanical Properties of the Invar Materials (인바재료의 기계적 성질에 미치는 풀림 열처리와 시험온도의 영향)

  • Won, Si-Tae;Kim, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.167-176
    • /
    • 2001
  • The effects of heat treatments and testing temperatures on the mechanical properties of Invar materials were investigated through experiments, which call influence the formability in metal forming fields. Annealing temperatures were changed from $900^{\circ}C$ to $1200^{\circ}C$ with an increment of $100^{\circ}C$ under two different furnace atmosphere(vacuum and H$_2$gas). Microstructure and hardness tests were performed for annealed specimens at room temperature(RT) and tensile tests were also performed by changing annealing temperatures as well as testing temperatures from RT to $300^{\circ}C$. The grain size of annealed materials increased with increasing annealing temperature, while micro-hardness distributions showed almost same hardness values regardless of annealing temperatures. Strength ratio (tensile/yield strength), which influences the forming characteristics of sheet metal, remained almost constant for various experimental conditions in case of unannealed specimens. However, it showed increasing tendency with increasing both annealing and testing temperatures, particularly at the testing temperature higher than $200^{\circ}C$. Therefore it can be concluded that press formability of fully-annealed Invar material can be improved by warm forming technique.

  • PDF

Investigation of Pathogenic Microorganism from Saengsik-classes (시판생식의 위해미생물 오염도 조사)

  • Cho, Joon-Il;Park, Yong-Chjun;Ko, Soo-Il;Cheung, Chi-Yeun;Lee, Sun-Mi;Cho, Soo-Yeol;Lee, Kwang-Ho;Lim, Chul-Joo;Kim, Ok-Hee
    • Journal of Food Hygiene and Safety
    • /
    • v.23 no.3
    • /
    • pp.257-263
    • /
    • 2008
  • As Standards and Specifications of the Saengsik-classes has been established since 2005 by KFDA. The microbial Standards and Specifications of the Saengsik-classes is as follows; no detection in Escherichia coli, colony forming unit less then 1,000/g in Bacillus cereus, colony forming unit less then 100/g in Clostridium perfringens respectively. Contamination levels of Total aerobic bacteria, Escherichia coli, Bacillus cereus and Clostridium perfringens in Saengsik-classes were monitored. Total aerobic bacteria counts in Saengsik-classes was $1{\times}10^1{\sim}5.3{\times}10^7cfu/g$, for Bacillus cereus $1{\times}10^2{\sim}9{\times}10^2cfu/g$, for Clostridium perfringens $1{\times}10^1cfu/g$. Escherichia coli, was not isolated from all Saengsik-classes. Thess results will provide information for introduction of HACCP system to ensure microbial safety of Saengsik-classes.

Development of Electrocardiogram Identification Algorithm for a Biometric System (생체 인식 시스템을 위한 심전도 개인인식 알고리즘 개발)

  • Lee, Sang-Joon;Kim, Jin-Kwon;Lee, Young-Bum;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.365-374
    • /
    • 2010
  • This paper is about the personal identification algorithm using an ECG that has been studied by a few researchers recently. Previously published algorithm can be classified as two methods. One is the method that analyzes ECG features and the other is the morphological analysis of ECG. The main characteristic of proposed algorithm uses together two methods. The algorithm consists of training and testing procedures. In training procedure, the features of all recognition objects' ECG were extracted and the PCA was performed for morphological analysis of ECG. In testing procedure, 6 candidate ECG's were chosen by morphological analysis and then the analysis of features among candidate ECG's was performed for final recognition. We choose 18 ECG files from MIT-BIH Normal Sinus Rhythm Database for estimating algorithm performance. The algorithm extracts 100 heartbeats from each ECG file, and use 40 heartbeats for training and 60 heartbeats for testing. The proposed algorithm shows clearly superior performance in all ECG data, amounting to 90.96% heartbeat recognition rate and 100% ECG recognition rate.

A Study on the Improvement Characteristics of Bio Active Energy Radiated Fabric in Muscle Fatigue (생체활성에너지 방사 소재의 근육피로도 개선 특성에 관한 연구)

  • Park, Hyo Suk;Park, Eun Ho;Rho, Yong Hwan;Yang, Gwang Wung
    • Textile Coloration and Finishing
    • /
    • v.26 no.3
    • /
    • pp.181-186
    • /
    • 2014
  • This paper surveys improvement characteristics in muscle fatigue with bio-activity material imbedded fabric. For this purpose, the subjects wear the garment which is covered by bio-activity materials all over every day during 2 weeks of experimental period. After 2 weeks period, VAS(Visual Analogue Scale) index evaluation regarding muscle fatigue and pain has been conducted in comparison between before wearing and after so that we can evaluate the effect on muscle fatigue improvement. The effectiveness survey for testing products consists of improvement on krunkle, muscle fatigue and exercise capacity. As a result, 100% of test subject group completes a questionnaire with positive answer as above normal in every question. In addition the preference of testing products is researched in wearing comfort, activity and convenience. And it is marked above normal by 100% of test subject group as well. Moreover any kind of unusual skin reaction has not been detected in safety evaluation. Therefore this testing products is being judged as a beneficent product for improvement on muscle fatigue without any skin irritation.