• Title/Summary/Keyword: 10-MDP

Search Result 111, Processing Time 0.027 seconds

A New BISON-like Construction Block Cipher: DBISON

  • Zhao, Haixia;Wei, Yongzhuang;Liu, Zhenghong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.5
    • /
    • pp.1611-1633
    • /
    • 2022
  • At EUROCRYPT 2019, a new block cipher algorithm called BISON was proposed by Canteaut et al. which uses a novel structure named as Whitened Swap-Or-Not (WSN). Unlike the traditional wide trail strategy, the differential and linear properties of this algorithm can be easily determined. However, the encryption speed of the BISON algorithm is quite low due to a large number of iterative rounds needed to ensure certain security margins. Commonly, denoting by n is the data block length, this design requires 3n encryption rounds. Moreover, the block size n of BISON is always odd, which is not convenient for operations performed on a byte level. In order to overcome these issues, we propose a new block cipher, named DBISON, which more efficiently employs the ideas of double layers typical to the BISON-like construction. More precisely, DBISON divides the input into two parts of size n/2 bits and performs the round computations in parallel, which leads to an increased encryption speed. In particular, the data block length n of DBISON can be even, which gives certain additional implementation benefits over BISON. Furthermore, the resistance of DBISON against differential and linear attacks is also investigated. It is shown the maximal differential probability (MDP) is 1/2n-1 for n encryption rounds and that the maximal linear probability (MLP) is strictly less than 1/2n-1 when (n/2+3) iterative encryption rounds are used. These estimates are very close to the ideal values when n is close to 256.

Clinical Utility of Bone Scan in the Diagnosis of Temporomandibular Disorders (측두하악장애의 진단에서 Bone Scan의 유용성)

  • Kim, In-Joo;Kang, Yang-Ho;Son, Seok-Man;Lee, Kyoung-Seog;Lee, Jae-Bok;Kim, Yong-Ki;Seo, Bong-Jik;Park, June-Sang;Ko, Myung-Yun;Son, Seong-Pyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.511-517
    • /
    • 1995
  • Bone scan is a very sensitive diagnostic imaging test for detecting bone and joint disorders. So it might be useful in the diagnosis of temporomandibular disorders of the joint origin. Thus, the effectiveness of bone scan for detecting temporomandibular joint(TMJ) diseases and differentiating the TMJ disc displacement from the TMJ arthritis was evaluated. Bone scan was done in 21 patients with TMJ disc displacement(13 unilaterally affected, 8 bilaterally affected), 25 patients with TMJ arthritis(23 unilateral, 3 bilateral), and 39 volunteers with no signs, symtoms, or history of TMJ disease. TMJ simple uptake rate(SUR) and difference of both TMJ SUR were calculated from the 100,000 count lateral image of head and neck region in 99mTc MDP bone scan. Transcranial and panorama X-ray examination was also done in all patients. TMJ SUR(%) were $1.673{\pm}0.606$ in TMJs affected with arthritis, $1350{\pm}0.351$ in TMJs affected with disc displacement, and $1.084{\pm}0.172$ in TMJs of controls. Significant differences were demonstrated among them(p<0.01) Difference of bith TMJ SUR was highest in patients with unilateral TMJ arthritis($0.608{\pm}$0.533, p<001), and there is no significant difference between that of controls and that of unilateral TMJ dist displacement patients($0.062{\pm}0.063$ vs $0.122{\pm}0.100$). TMJ SUR of Joint with bone change on X-ray finding was not significantly different from that of joint with normal X-ray finding. Those in patients with unilateral TMJ disc displacement(696% and 87% vs 23.1% and 23%). The proportions of patients with increased TMJ SUR and difference of both TMJ SUR(>mean+2SD of controls) in unilateral TMJ arthritis patients were significantly higher than those in patients with unilateral TMJ disc displacement(69.6% and 87% vs 23.1% and 23%). Conclusively, bone scan nay help to detect TMJ disease and differentiate TMJ disc displacement from TMJ arthritis.

  • PDF

Comparison of shear bond strength according to various surface treatment methods of zirconia and resin cement types (지르코니아의 다양한 표면처리 방법과 레진시멘트 종류에 따른 전단결합강도 비교)

  • Bae, Ji-Hyeon;Bae, Gang-Ho;Park, Taeseok;Huh, Jung-Bo;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.153-163
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the effects of four surface treatment methods to improve zirconia roughness and three types of resin cement on the shear bond strength (SBS). Materials and methods: A total of 120 zirconia blocks were randomly divided into four surface treatments: non-treatment (Control), airborne-particle abrasion (APA) with 50 ㎛ Al2O3 (APA50), APA with 125 ㎛ Al2O3 (APA125), and ZrO2 slurry (ZA). Three resin cements (Panavia F 2.0, Superbond C&B, and Variolink N) were applied to the surface-treated zirconia specimens. All specimens were subjected to SBS testing using a universal testing machine. The surface of the representative specimens of each group was observed by scanning electron microscope (SEM). SBS data were analyzed with oneway ANOVA, two-way ANOVA test and post-hoc Tukey HSD Test (α=.05). Results: In the surface treatment method, APA125, APA50, ZA, and Control showed high shear bond strength in order, but there was no significant difference between APA125 and APA50 (P>.05). Also, ZA showed significantly higher shear bond strength than Control (P<.05). In the resin cement type, Panavia F 2.0, Superbond C&B, and Variolink N showed significantly higher shear bond strength in order (P<.05). In SEM images, the zirconia surfaces of the APA50 and APA125 showed quite rough and irregular shapes, and the zirconia surface of the ZA was observed small irregular porosity and rough surfaces. Conclusion: APA and ZrO2 slurry were enhanced the surface roughness of zirconia, and Panavia F 2.0 containing MDP showed the highest shear bond strength with zirconia.

Effect of Treatment with Transdermal Ketoprofen on Adjuvant-Induced Arthritis (Adjuvant-induced arthritis에 대한 경피용 ketoprofen 제제의 치료효과)

  • Shim, Kyung-Mi;Kim, Se-Eun;Bae, Chun-Sik;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.400-404
    • /
    • 2006
  • This study demonstrates the anti-arthritic effect of topical application of ketoprofen gel containing N-methyl-2-pyrrolidone (NMP) in adjuvant arthritis therapy. Adjuvant arthritis was induced by a single injection of Freund's complete adjuvant (FCA). Mature female Sprague-Dawley rats were designated to 3 groups such as control group, K10 group (ketoprofen 10 mg/rat), and NK10 group (ketoprofen 10 mg/rat containing NMP). The anti-arthritic activity of ketoprofen containing NMP was tested not only as to its capability to suppress the inflammatory edema, but also bone damage (X-ray score and regional bone uptake) of the hind paw in arthritis-induced rats. These results showed a higher efficacy of ketoprofen containing NMP than ketoprofen treatment in the adjuvant-induced arthritis. Ketoprofen containing NMP has good intrinsic characteristics for formulation in an efficacious anti-inflammatory topical application.

Scintigraphic Findings of Fibrous Dysplasia (섬유성 골 이형성증의 골 신티그라피 소견)

  • Kim, Jong-Ho;Kim, Jong-Soon;Han, Seung-Soo;Kim, Sang-Eun;Choi, Chang-Woon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Kang, Heung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.219-226
    • /
    • 1991
  • 골 신티 그라피는 섬유성 골 이형성증의 초기 병소와 다골성 형 섬유성 골 이형성증의 진단에 예민한 검사 방법이나, 양성 또는 악성 골 병변과의 감별진단에 어려움이 있었다. 이에 저자들은 조직학적으로 확진된 섬유성 골 이형성증 환자 17명에서 (단골성 형 12명, 다골성 형 : 5명) $^{99m}Tc-MDP$ (20 mCi 또는 7,400 MBq) 주사후 $2\sim4$시간에 전면, 후면 전신상과 부분상을 얻은 30부위 병소를 X선 사진과 비교분석 하였으며 CT, MRI 영상과 병리조직 소견을 얻었다. 병소 침습 부위별로는 대퇴골-10예, 경골-4, 요골-2, 늑골-2, 척추골-2, 후두골-2, 장골-2, 두정골-1, 하악골-1, 접형골-1, 견갑골-1, 쇄골-1, 척골-1예 였으며 5명의 다골성 형에서는 :우 대퇴골과 우 비골 : 양측 말단 대퇴골 :좌 경골과 좌 대퇴골 :우 요골과 우 장골 양측 대퇴골, 양측 경골, 접형골, 두정골, 척추골, 늑골과 장골이었다. 골 신티 그라피 소견상 30예중 28예에서(28/30, 93.3%) 방사능 섭취 증가를 보였으며 2예에서(2/30, 6.7%)는 정상 방사능 섭취 소견을 보였으나 각각은 X선상 불투명 유리상과 골흡수 병변을 보였다. 하악골의 골 3상 스캔상 병소에 현저한 혈류 증가가 관찰되었다. X선 소견상 30예중 11예에서 (l1/30, 36.7%) 불투명 유리상의 병변을, 골 변형을 동반한 1예를 포함한 18예에서는 (18/30, 60.0%) 골흡수 병변을 보였으며, 1예의 늑골 병변은 정상소견을 보였다(1/30, 3.3%). 이상에서 골 신티 그라피 만으로 섬유성 골 이형성증을 진단하는데는 주의를 요하나 골 대사의 동적 측면인 혈류와 골 재형성 양상 특히, 초기 병변과 단골성 형 침습에서 다골성 형을 진단하는데 필수적이며 결론적으로 골 신티 그라피와 X선 촬영등은 섬유성 골 이형성증 진단에 상호보완적인 검사 방법으로 사료된다.

  • PDF

Lower Incidence but More Aggressive Behavior of Right Sided Breast Cancer in Pakistani Women: Does Right Deserve More Respect?

  • Fatima, Nosheen;Zaman, Maseeh Uz;Maqbool, Aamir;Khan, Shaista H.;Riaz, Nazia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.43-45
    • /
    • 2013
  • Background: The aim of this epidemiological study was to establish the laterality of breast cancer (BC) and its association with size, receptor status of the primary tumor and bone metastasis (BM) in a local population. Materials and Methods: This retrospective study included cases of BC from Jan-2009 to Dec-2011 who were referred for metastatic work up or follow up survey with Technetium-99m MDP bone scan (BS) to the Nuclear Medicine Department of Karachi Institute of Radiotherapy and Nuclear Medicine (KIRAN). A total of 384 patients out of 521 were included and all reviewed for age, primary tumor size (PTS), laterality, receptor status like estrogen receptor (ER) progesterone receptor (PR) and Her-2-Neu receptor, presence or absence of BM with sites of involvement and time interval between diagnosis of BC and appearance of BM. Results: The left to right sided BC proportion was significantly higher than unity (59%:41%; p<0.001). The right sided BC was observed in younger age group (46:52 years; p<0.0001) and with a smaller PTS than the left sided (3.43:4.15 cm; p<0.0001). The patients with BM had relatively higher negative receptor status with a significant predominance of right sided BC. The overall incidence of BM on BS was 28% and relatively higher in right than left breast (33%:24% p=0.068). The average number of BM sites was also significantly greater for the right side (6:4, P<0.0001). The % cumulative risk of BM in right breast was noted at significantly smaller PTS than left side with log rank value of 5.579; p<0.05. The Kaplan Meier survival plot for event free survival of BM in left sided BC was significantly higher than for the right side (log rank value=4.155, p<0.05), with an earlier appearance of BM in right BC. Conclusions: 1) A left sided predominance of BC was seen in local population; 2) right sided BC had a more aggressive behavior with extensive and earlier appearance of BM at relatively younger age, smaller PTS and receptor (s) negativity.

Significance of Hormone Receptor Status in Comparison of 18F -FDG-PET/CT and 99mTc-MDP Bone Scintigraphy for Evaluating Bone Metastases in Patients with Breast Cancer: Single Center Experience

  • Teke, Fatma;Teke, Memik;Inal, Ali;Kaplan, Muhammed Ali;Kucukoner, Mehmet;Aksu, Ramazan;Urakci, Zuhat;Tasdemir, Bekir;Isikdogan, Abdurrahman
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.387-391
    • /
    • 2015
  • Background: Fluorine-18 deoxyglucose positron emission tomography computed tomography (18F-FDG-PET/CT) and bone scintigraphy (BS) are widely used for the detection of bone involvement. The optimal imaging modality for the detection of bone metastases in hormone receptor positive (+) and negative (-) groups of breast cancer remains ambiguous. Materials and Methods: Sixty-two patients with breast cancer, who had undergone both 18F-FDG-PET/CT and BS, being eventually diagnosed as having bone metastases, were enrolled in this study. Results: 18F-FDG-PET/CT had higher sensitivity and specificity than BS. Our data showed that 18F-FDGPET/CT had a sensitivity of 93.4% and a specificity of 99.4%, whiel for BS they were 84.5%, and 89.6% in the diagnosis of bone metastases. ${\kappa}$ statistics were calculated for 18F-FDGPET/CT and BS. The ${\kappa}$-value was 0.65 between 18F-FDG-PET/CT and BS in all patients. On the other hand, the ${\kappa}$-values were 0.70 in the hormone receptor (+) group, and 0.51 in hormone receptor (-) group. The ${\kappa}$-values suggested excellent agreement between all patient and hormone receptor (+) groups, while the ${\kappa}$-values suggested good agreement in the hormone receptor (-) group. Conclusions: The sensitivity and specificity for 18F-FDG-PET/CT were higher than BS in the screening of metastatic bone lesions in all patients. Similarly 18F-FDG-PET/CT had higher sensitivity and specificity in hormone receptor (+) and (-) groups.

A Tactical Internet Geocasting Protocol for Efficient Message Delivery (효율적인 메시지 전달을 위한 전술인터넷 지오캐스팅 프로토콜)

  • Yoon, Sun-Joong;Ko, Young-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1050-1061
    • /
    • 2009
  • The Tactical Internet(TI) managed by Infantry Brigades is used for the purpose of sharing information of Command Control and Situation Awareness. When there are more than two destinations to transmit data in the TI system, a multicasting is utilized based on pre-defined multicast groups. However even in the case when a source node needs to send some messages like weathercast and attack alarm etc to only a part of Battalion or Brigades in a specific geographical region (destination region), the current TI multicasting protocol is designed to transmit the messages to the pre-defined group or all of the Battalion/Brigade nodes, resulting in inefficiency in terms of end-to-end delay and overhead. In this paper, we propose more efficient protocol for such cases, named as "Tactical Internet Geocasting (TIG)". The proposed scheme firstly checks whether the destination region belongs to one Battalion region or more than two Battalion regions using location information, and then performs a greedy forwarding from the source node to the destination region, followed by a local flooding inside of the destination region. With performance analysis and simulations using NS-2, TIG is compared to the current TI multicasting protocol (i.e., Simplified MDP) and the LBM (Location-based Multicast). The simulation results show that the proposed TIG is more efficient than both in terms of delay and network overhead.

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

The Usefulness of Postoperative Pinhole Bone Scintigraphy in the Assessment of Prognosis after Multiple Drilling or Vascularized Bone Graft in Patients with Avascular Necrosis of Femoral Head (다발성 천공술 및 혈관 부착 골이식술을 시행한 대퇴골두 무혈관성 괴사의 예후: 수술 후 바늘구멍 골신티그라피의 유용성)

  • Chung, Yong-An;Kim, Sung-Hoon;Chun, Kyung-Ah;Park, Young-Ha;Sohn, Hyung-Seon;Chung, Soo-Kyo;Song, Mun-Kab
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.405-412
    • /
    • 1999
  • Purpose: It is important to evaluate the healing process of avascular necrosis (AVN) involving femoral head after treatment. The purpose of this study was to assess the usefulness of pinhole bone scintigraphy in the AVN of femoral head after surgery. Materials and Methods: We analyzed the changing pattern of pinhole bone scintigram in 21 femoral heads of 16 patients (14 lesions/11 male, 7 lesions/5 female, mean age: 39.4 yrs) before and after multiple drilling or vascularized bone grafting for AVN of the femoral head. In all patients, pre-operative scintigrams were obtained at 1 to 3 months before treatment and the first post-operative scintigrams were obtained at 1 to 3 months after treatment. All patients were followed for 2 to 4 years after operation. Results: The findings of the pinhole scintigrams were divided into three patterns: 1) curvilinear, 2) scattered spotty and 3) undetermined. The 10 of 11 lesions with curvilinear pattern had good postoperative clinical and radiological follow-up findings. However, all 6 lesions with scattered spotty pattern showed poor postoperative findings, which necessitated total hip joint replacement. Of the 4 lesions with undetermined pattern, 2 required total hip joint replacement. There was significant difference in postoperative prognosis between the curvilinear and scattered spotty patterns (p<0.05). Conclusion: We conclude that the pattern of pinhole bone scintigram obtained within 1 to 3 months after multiple drilling or vascularized bone graft operation is a useful prognostic indicator in the AVN of femoral head.

  • PDF