• Title/Summary/Keyword: 1-unit

Search Result 13,973, Processing Time 0.042 seconds

Proposal of Unit Building Method for Calculating Unit Heating Load of Apartment Houses (공동주택 단위난방부하 계산을 위한 단위동법 제안)

  • Yoo Ho-Seon;Chung Joo-Hyuk;Moon Jung -Hwan;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2007
  • As an alternative approach to evaluate the unit heating load for apartment houses, we newly developed and proposed unit building method. The new method, which calculates the heating load of an apartment building as a whole, conceptually corresponds to integral analysis of building heat loss, while the existing unit apartment method to differential analysis. Four typical building models of Korean-style apartment house and two dynamic load calculation programs were selected to validate the present method under realistically imposed conditions. Eight sets of unit heating load calculated respectively by unit building and unit apartment methods showed excellent agreements regardless of building model and simulation program. It is expected that the unit building method can take the place of the unit apartment method due to fewer modeling assumptions as well as less computational efforts. Additional calculations to investigate the effects of various parameters on unit heating load yield good consistencies with known facts, and re-confirm the validity.

Human and organizational factors for multi-unit probabilistic safety assessment: Identification and characterization for the Korean case

  • Arigi, Awwal Mohammed;Kim, Gangmin;Park, Jooyoung;Kim, Jonghyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.104-115
    • /
    • 2019
  • Since the Fukushima Daiichi accident, there has been an emphasis on the risk resulting from multi-unit accidents. Human reliability analysis (HRA) is one of the important issues in multi-unit probabilistic safety assessment (MUPSA). Hence, there is a need to properly identify all the human and organizational factors relevant to a multi-unit incident scenario in a nuclear power plant (NPP). This study identifies and categorizes the human and organizational factors relevant to a multi-unit incident scenario of NPPs based on a review of relevant literature. These factors are then analyzed to ascertain all possible unit-to-unit interactions that need to be considered in the multi-unit HRA and the pattern of interactions. The human and organizational factors are classified into five categories: organization, work device, task, performance shaping factors, and environmental factors. The identification and classification of these factors will significantly contribute to the development of adequate strategies and guidelines for managing multi-unit accidents. This study is a necessary initial step in developing an effective HRA method for multiple NPP units in a site.

Structure-antibiotic activity of cecropin A(1-8)-magainin 2(1-12), cecropin A(1-8)-melittin(1-12) hybrid peptides and their analogues studied by NMR spectroscopy

  • Donghoon Oh;Songyub Shin;Joohyun Kang;Hahm, Kyung-soo;Kim, Killyong;Kim, Yangmee
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1999.06a
    • /
    • pp.32-32
    • /
    • 1999
  • Cecropin A(1-8)-magainin 2(1-12) and cecropm A(1-8)-melittin(1-12) hybrid peptides were known to have potent antitumor and antibacterial activity. In particular, cecropm A(l-8)-magainin 2(1-12) has powerful antibacterial and antitumor activity with no hemolytic effect.(omitted)

  • PDF

A Correlation Between Fibrinolytic Activity and Microflora in Korean Fermented Soybean Products (된장의 혈전용해효소 활성과 미생물 분포와의 상관관계)

  • 김동호;송현파;김기연;김정옥;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2004
  • A correlation between fibrinolytic activity and microflora in Korean traditional soybean fermented food was investigated. The fibrinolytic activities of traditional soybean pastes and commercially processed samples were 2.42$\pm$1.01 unit/g and 1.58$\pm$0.98 unit/g, respectively. The cell density of Bacillus in traditional soybean pastes was about 10$^{7}$ CFU/g and its commercially processed one was 10$^{6}$ CFU/g. Acid producing bacteria, fungi and yeast group were higher in commercially processed one. The correlations of fibrinolytic activity and microflora in traditional and commercial Doenjang were positively correlated in Bacillus ($R^2$≒ 0.69), negatively correlated in fungal group ($R^2$≒0.40), and there were no significant correlations in acid forming bacteria and yeast group ($R^2$<0.16). Fibrinolytic activities in Meju and Koji were 6.54$\pm$1.97 unit/g and 1.46$\pm$0.43 unit/g respectively, and were positively correlated with Bacillus. Yeast and acid forming bacteria were grown by 5∼6 decimal induction during fermentation period of Doenjang, but Bacillus, fungal cells and fibrinolytic activity were nearly stable. Results indicate that fibrinolytic activity of Doenjang depends on enzyme induction in Meju or Koji processing by Bacillus, Doenjang fermentation process.

A Multiple Unit Roots Test Based on Least Squares Estimator

  • Shin, Key-Il
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.1
    • /
    • pp.45-55
    • /
    • 1999
  • Knowing the number of unit roots is important in the analysis of k-dimensional multivariate autoregressive process. In this paper we suggest simple multiple unit roots test statistics based on least squares estimator for the multivariate AR(1) process in which some eigenvalues are one and the rest are less than one in magnitude. The empirical distributions are tabulated for suggested test statistics. We have small Monte-Calro studies to compare the powers of the test statistics suggested by Johansen(1988) and in this paper.

  • PDF

A study on the Architectural Planning of Operating-Unit in General Hospital (종합병원의 수술유니트 계획에 관한 연구)

  • Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.7 no.1
    • /
    • pp.77-84
    • /
    • 2001
  • This study provide the planning guidelines for the existing and the new alternative. On the bases of survey and analysis, the basic data for OP-Unit have been proposed in consideration of the development of medical science and hygiene, economic conditions during the last twenty years in Germany. The results of the study were firstly, genera1 basic data, secondly, guidelines of the architectural design for OP-Unit und rooms, thirdly, new alternative OP-Unit with 2 and 3 operation rooms.

  • PDF

An Analysis of Magnet Unit of Electro-Pneumtic Control Valve Positioner (전공식 콘트롤 밸브 Positioner 용 Magnet Unit의 해석)

  • 김성재;김지원;조순철;정선태;유형근;전찬구;고택범
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.6
    • /
    • pp.321-326
    • /
    • 1997
  • We analyzed an important part of control valve, magnet unit, which is used to control the fluid. Magnetic circuit which is composed of magnet and yoke is analyzed using finite element method. Then, flux density and coil force were calculated and compared with those of measured. According to the simulation results, the gap field, force constant, and permeance coefficient were 3~5 kG, 27.5 N/A, 22.1, respectively, which corresponded reasonably well with the measured values. We also obtained reluctance factor of 1.1 and fringing factor of 1.4 by simulation.

  • PDF

Synergistic Effect of Physico-chemical Treatment and Bacteriocin Produced by Enterococcus faecium MJ-14 (Enterococcus faecium MJ-14가 생산하는 박테리오신과 물리화학적 처리의 상승효과)

  • Lim Sung-Mee
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.217-224
    • /
    • 2005
  • When L. monocytogenes ($10^{5}CFU/mL$) at exponential phase cells were heated for 5 min at $65^{\circ}C$ in the presence of the bacteriocin (30 BU/mL) produced by E. faecium MJ-14, the number of viable cells was markedly reduced at p < 0.05. The bactericidal effect of bacteriocin showed synergism with combination ot organic acids (citric acid or acetic acid) or chemical preservatives (sodium benzoate, sodium lactate, sodium nitrate or potassium nitrate). For example, the number of viable cells was reduced by 4.8 log units under combination of the bacteriocin (30 BU/mL) and sodium nitrate ($100{\mu}g/mL$), while it was reduced by 1.1 log unit only under single treatment of the bacteriocin after 12 k at $37^{\circ}C$. The addition of the bacteriocin (300 BU/mL) into skim milk inoculated with L. monocytogenes ($10^{5}$CFU/mL) reduced the cells by 1.5 log unit, in case of the cell suspension stored at $4^{\circ}C$ for 24 hr. Moreover, L. monocytogenes was reduced by 2 log unit when stored at $-20^{\circ}C$ for 7 days in gound pork added with 300 BU/mL of 린e bacteriocin.

Development of an Automatic Inspection System for PWM Shaft Using Machine Vision (머신비전을 이용한 PWM Shaft의 자동검사 시스템 개발)

  • Bae, Jin-Ho;Kim, Sung-Gaun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.125-130
    • /
    • 2013
  • In this paper, in order to overcome shortcomings of manual inspection for the automotive PWM Shaft, we developed an automated inline inspection system. The automated inline inspection system consists of the work feeder unit, conveying unit, outer diameter check unit, run-out and roundness check unit, machine vision, defective separation unit and status alarm unit. We used the machine vision system for automatic inspection process and designed the inline systems for automatic feeding and selecting process. Also the repeated operation test was performed in order to verify the precision and reliability of the proposed automated inline inspection system.