• Title/Summary/Keyword: 1-unit

Search Result 13,939, Processing Time 0.045 seconds

Decay Heat Evaluation of Spent Fuel Assemblies in SFP of Kori Unit-1

  • Kim, Kiyoung;Kim, Yongdeog;Chung, Sunghwan
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.11a
    • /
    • pp.104-104
    • /
    • 2018
  • Kori Unit 1 is the first permanent shutdown nuclear power plant in Korea and it is on June 18th, 2017. Spent fuel assemblies began to be discharged from the reactor core to the spent fuel pool(SFP) within one week after shutdown of Kori unit 1 and the campaign was completed on June 27th, 2017. The total number of spent nuclear fuel assemblies in SFP of Kori Unit-1 is 485 and their discharging date is different respectively. So, decay heat was evaluated considering the actual enrichment, operation history and cooling time of the spent fuel assemblies stored in SFP of the Kori Unit-1. The code used in the evaluation is the ORIGEN-based CAREPOOL system developed by KHNP. Decay heat calculation of PWR fuel is based on ANSI/ANS 5.1-2005, "Decay heat power in light water reactors" and ISO-10645, "Nuclear energy - Light water reactors - Calculation of the decay heat power in nuclear fuels. Also, we considered the contribution of fission products, actinide nuclides, neutron capture and radioactive material in decay heat calculation. CAREPOOL system calculates the individual and total decay heat of all of the spent fuel assemblies in SFP of Kori Unit-1. As a result, the total decay heat generated in SFP on June 28th, 2017 when the spent fuel assemblies were discharged from the reactor core, is estimated to be about 4,185.8 kw and to be about 609.5 kw on September 1st, 2018. It was also estimated that 119.6 kw is generated in 2050 when it is 32 years after the permanent shutdown. Figure 1 shows the trend of total decay heat in SFP of Kori Unit-1.

  • PDF

Analysis and Design of Low Pass Filter using Unit Cell based on CRLH Transmission Line

  • Yang, Lei;Yang, Doo-Yeong
    • International Journal of Contents
    • /
    • v.8 no.3
    • /
    • pp.100-104
    • /
    • 2012
  • In this paper, a unit cell for low pass filter design by using composite right and left-handed transmission line in conductor-backed coplanar waveguide is proposed. The characteristics of the unit cell are analyzed in order to design a low pass filter in small sizes. By changing the sizes of the unit cell, the parameters of right-handed and left-handed immittance components are changed and the desired characteristics of the unit cell are achieved. The equivalent circuit of the unit cell is extracted and analyzed either. As a result, the simulation results of the unit cell and the equivalent circuit are almost identified. The movement and energy distributions of electromagnetic field are shown to confirm the property of the unit cell. In the end, a low pass filter is demonstrated by cascading three proposed unit cells, which shows cutoff frequency of 1.53GHz and deep attenuation from 2.23GHz to 4.49GHz lower than -50dB.

Improved One-pot Regioselective Synthesis of 3,7-Diarylpyrazolo[1,5-α]pyrimidines and Their CB1R Activity (3,7-Diarylpyrazolo[1,5-α]pyrimidines의 개선된 One-pot Regioselective 합성과 CB1R 활성)

  • Hong, Yong Deog;Byoun, Kyoung Hee;Park, Miyoung;Park, Jun Seong;Shin, Song Seok
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.41 no.2
    • /
    • pp.143-150
    • /
    • 2015
  • This study demonstrates an effective one-pot regioselective synthesis of 3,7-diarylpyrazolo [1,5-${\alpha}$]pyrimidines. Moreover, the derivatives obtained were effective CB1R antagonists. These pyrazolo [1,5-${\alpha}$]pyrimidines with diaryl groups at the 3,7-positions are potential pharmacophores for CB1R candidates.

STRUCTURES CONCERNING GROUP OF UNITS

  • Chung, Young Woo;Lee, Yang
    • Journal of the Korean Mathematical Society
    • /
    • v.54 no.1
    • /
    • pp.177-191
    • /
    • 2017
  • In this note we consider the right unit-duo ring property on the powers of elements, and introduce the concept of weakly right unit-duo ring. We investigate first the properties of weakly right unit-duo rings which are useful to the study of related studies. We observe next various kinds of relations and examples of weakly right unit-duo rings which do roles in ring theory.

A Study of Characteristics of Pectinesterase, Polygalacturonase and Peroxidase in Kimchi Materials (김치재료에 존재하는 Pectinesterase, Polygalacturonase 및 Peroxidase 특성에 관한 연구)

  • Park, Hee-Ok;Kim, Kee-Hyun;Yoon, Sun
    • Journal of the Korean Society of Food Culture
    • /
    • v.5 no.4
    • /
    • pp.443-448
    • /
    • 1990
  • The object of this study was to investigate the characteristics of pectinesterase(PE), polygalacturonase(PG) and Peroxidase(POD) in Kimchi materials. The results were as follows : 1. The specific activities of PEs in Korean cabbage, Korean raddish, garlic and ginger were 200 unit/mg protein, 23.1 unit/mg protein, 0.8 unit/mg protein and 32 unit/mg protein, respectively. The optimum pHs of PEs in all materials were between 7 to 8. The concentrations of NaCl, $CaCl_2$ which showed the highest activities of PEs were $0.2{\sim}0.3M$ NaCl, 50 mM $CaCl_2$ in Korean cabbage and raddish, 0.05 M NaCl, 20 mM $CaCl_2$ in garlic and 0.2 M NaCl, 20 mM $CaCl_2$ in ginger. 2. The specific activities and the optimum pHs of PGs were 1.5 unit/mg protein and pH 4.5 in Korean cabbage, 1.6 unit/mg protein and $pH\;4.5{\sim}5.5M$ in Korean raddish, 0.06 unit/mg protein and $pH\;3.0{\sim}3.5M$ in garlic, and 0.06 unit/mg protein and $CaCl_2$ in ginger. The concentrations of NaCl, $CaCl_2$ which showed the highest activities of PGs were $0.1{\sim}0.2M$ NaCl and $0.15{\sim}0.2mM$ mM $CaCl_2$ in all materials. 3. The specific activities and the optimum pHs of PODs in Korean cabbage, Korean raddish, garlic and ginger were 71.3 unit/mg protein ; pH 6.0. 769 unit/mg protein ; pH 5.5, 1.09 unit/mg protein ; pH 4.5 and 12.7 unit/mg protein ; $pH\;5.0{\sim}5.5M$, respectively. POD activities were not decreased in Korean cabbage, but decreased in Korean raddish by the increase of NaCl, $CaCl_2$ concentrations. In garlic and ginger, POD activities were a little slightly affected by the increase of NaCl, $CaCl_2$ concentrations.

  • PDF

Antioxidant Enzyme Activity and Antimicrobial Activity of Isatis tinctoria Extract (대청 추출물의 항산화 효소 활성 및 항균 효과)

  • Heo, Buk-Gu;Park, Yun-Jum;Lee, Seung-Jin;Kim, Kwan-Su;Cho, Ja-Yong;Boo, Hee-Ock
    • Korean Journal of Plant Resources
    • /
    • v.25 no.5
    • /
    • pp.543-549
    • /
    • 2012
  • To gather the basic data for increasing the utilization of Isatis tinctoria, we examined the effects of both antioxidative enzyme activity and antimicrobial activity from the extract of Isatis tinctoria. Ascorbate Peroxidase activities reveal that there is an decrease in order; ethanol extract from its stem (1601.7 Unit/mg protein), methanol extract from its leaf (1133.7 Unit/mg protein) and distilled water extract from its leaf (524.3 Unit/mg protein). Catalase activities reveal that there is an decrease in order; ethanol extract from its flower petal (177.1 Unit/mg protein), methanol extract from its leaf (120.8 Unit/mg protein) and distilled water extract from its flower petal (55.4 Unit/mg protein). Peroxidase activities reveal that there is an decrease in order; ethanol extract from its flower petal (27.1 Unit/mg protein), methanol extract from its flower petal (14.6 Unit/mg protein) and distilled water extract from its stem (10.4 Unit/mg protein). Superoxide dismutase activities reveal that there is an increase in order; distilled water extract from its root (90.8%), methanol extract from its flower petal (80.1%) and ethanol extract from its root (75.5%). Its flower extract showed a antimicrobial activity only against Vibrio parahaemolyticus, its root extract had only against Staphylococcus aureus, and its stem extract had against Bacillus subtilis, Escherichia coli and Staphylococcus aureus, regardless of solvents. Especially, distilled water extract from its leaf showed a high antimicrobial activity against both Bacillus subtilis and Escherichia coli and inhibition diameters against those were 30.0 and 24.0 mm, respectively.

Investigation and Analysis of Unit Industrial Water Usage Considering Latest Industrial Trend (최신 산업동향을 고려한 공업단지 사용량 원단위 분석 연구)

  • Kim, Kibum;Yu, Youngjun;Choi, Woojin;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.447-457
    • /
    • 2017
  • This study derived the unit of industrial water usage reflecting the latest industry trends. Available for establishing plans such as the master plan for water supply system and analyzed changes in the basic unit by a comparison with the current basic unit values. This study analyzed 4,038 samples with a sampling error of less than 1.5 % at the 95 % confidence level after removing outliers according to a log-normal distribution. As a result, the unit of industrial water usage per site area in the whole manufacturing industry was 7.11 m3/1,000m2/d. The ten industrial categories (C10, C13, C20, C21, C22, C25, C27, C30, C32, C33) showed a similar unit value compared to before, and the four industrials categories (C11, C17, C22, C31) showed a more unit value than before. With regard to the nine industrial categories (C14, C15, C16, C18, C19, C24, C26, C28, C29), the unit value decreased. Cases that companies examined before were the same as the companies examined in this study were analyzed. The result that the changes in the unit industrial water usage were reasonable was obtained. However, in some industrial categories (C17, C14, C24, C29), the unit value was changed by a small number of companies with large-scale water use or unit value of sampling had a large deviation. It was considered necessary to survey them periodically. The unit of industrial water usage derived by the survey in this study reflects the current industrial trends in 2016. Water use in manufacturing companies has continuously changed by the development of manufacturing technologies and simplification of manufacturing processes. In order to deal with this, it is considered necessary to survey the usage of industrial water periodically from a long-term perspective.

The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular (유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구)

  • Lee, Chang-Jae;Lim, Seok-Ho
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

A Study on the Development of Unit Catalog System for Curriculum Linkage in School Libraries: Focusing on Middle School Science Department (교과연계를 위한 학교도서관 단원목록 시스템의 개발에 관한 연구 - 중학교 과학과를 중심으로 -)

  • Bolan, Kim;Jeong-Hyen, Kim
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.33 no.4
    • /
    • pp.27-47
    • /
    • 2022
  • The purpose of the study is to develop a unit catalog system that can be linked with the curriculum. As for the research method, first, unit subject words were extracted through the analysis of middle school curriculum and science textbooks in all grades. Based on this, we designed a unit catalog system that has a unit book catalog by connecting books related to the unit topic of the subject, an index word catalog that organizes unit subject words into index words, and a grade and school level linked subject linked to the unit topic as a subsystem. Using the Notion program, a unit catalog system was implemented on the web using a middle school science unit 1 as a sample. To evaluate the system, experiments and surveys were conducted targeting students, and very positive results were shown in terms of satisfaction with the system and intention to use it in the future. Meanwhile, this study was limited to middle school science departments, but it was proposed to expand the application to all grades and subjects.

The Life Cycle Cost Estimation for Domestic Products Motor Block of KTX-1 Considering Periodic Maintenance (유지보수정보 주기를 고려한 KTX-1 모터블럭 개발품의 수명주기비용 예측)

  • Yun, Cha-Jung;Noh, Myoung-Gyu;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.288-292
    • /
    • 2013
  • This paper presents the result of life-cycle cost (LCC) estimation for domestic products propulsion control system (motor block unit) of KTX-1 considering periodic maintenance. Life cycle costing is one of the most effective approaches for the cost analysis of long-life systems such as the KTX-1. Life cycle costing includes the cost of concept design, development, manufacture, operation, maintenance and disposal. To estimate LCC for domestic products motor block unit, it was analyzed physical breakdown structure (PBS) on motor unit in view of maintenance cost and unit cost etc. As a results, life cycle cost on motor block unit increased moderately expect for periodical time when major parts are replaced at the same time. hereafter this results will be reflected in the domestic products being developed.