• 제목/요약/키워드: 1-dimensional measurement

검색결과 746건 처리시간 0.025초

Usefulness of four commonly used neuropathic pain screening questionnaires in patients with chronic low back pain: a cross-sectional study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • 제30권1호
    • /
    • pp.51-58
    • /
    • 2017
  • Background: Recently symptoms-based screening questionnaires have gained attention for screening for a neuropathic pain component (NePC) in various chronic pain conditions. The present study assessed the usefulness of four commonly used NePC screening questionnaires including the Self-completed douleur neuropathique 4 (S-DN4), the ID Pain, the painDETECT questionnaire (PDQ), and the Self-completed Leeds Assessment of neuropathic Symptoms and Signs (S-LANSS) questionnaire in patients with chronic low back pain (CLBP) to assess the presence of NePC. Methods: This is a single-center cross-sectional study where patients with CLBP, with or without leg pain, were included. Participants were initially screened for NePC presence by a physician according to the regular practice, and later assessed using screening questionnaires. The diagnostic accuracy of these questionnaires was compared assuming the physician-made diagnosis as the gold standard. Results: A total of 215 patients with CLBP of which 164 (76.3%, 95% CI, 70.2-81.5) had a NePC were included. S-DN4, ID Pain, and PDQ have an area under the curve (AUC) > 0.8 indicating excellent discrimination. However, S-LANSS has an AUC of 0.69 (0.62-0.75), indicating low discrimination. S-DN4 has a significantly higher AUC as compared to ID Pain (d(AUC) = 0.063, P < 0.01) and S-LANSS (d(AUC) = 0.197, P < 0.01). But the AUC of S-DN4 does not significantly differ from that of PDQ (d(AUC) = 0.013, P = 0.62). Conclusions: S-DN4, ID Pain, and PDQ, but not S-LANSS, have good discriminant validity to screen for NePCs in patients with CLBP. Despite using all the tests, 20-30% of patients with an NePC were missed. Thus, these questionnaires can only be used as an initial clue in screening for NePCs, but do not replace clinical judgment.

Experimental study on the method of estimating the vertical design wave force acting on a submerged dual horizontal plate

  • Kweon, Hyuck-Min;Oh, Sang-Ho;Choi, Young-Hwan
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권4호
    • /
    • pp.569-579
    • /
    • 2013
  • A steel-type breakwater that uses a submerged dual horizontal porous plate was originally proposed by Kweon et al. (2005), and its hydrodynamic characteristics and design methodology were investigated in a series of subsequent researches. In particular, Kweon et al. (2011) proposed a method of estimating the vertical uplift force that acts on the horizontal plate, applicable to the design of the pile uplift drag force. However, the difference between the method proposed by Kweon et al. (2011), and the wave force measured at a different time without a phase difference, have not yet been clearly analyzed. In this study, such difference according to the method of estimating the wave force was analyzed, by measuring the wave pressure acting on a breakwater model. The hydraulic model test was conducted in a two-dimensional wave flume of 60.0 m length, 1.5 m height and 1.0 m width. The steepness range of the selected waves is 0.01~0.03, with regular and random signals. 20 pressure gauges were used for the measurement. The analysis results showed that the wave force estimate in the method of Kweon et al. (2011) was smaller than the wave force calculated from the maximum pressure at individual points, under a random wave action. Meanwhile, the method of Goda (1974) that was applied to the horizontal plate produced a smaller wave force, than the method of Kweon et al. (2011). The method of Kweon (2011) was already verified in the real sea test of Kweon et al. (2012), where the safety factor of the pile uplift force was found to be greater than 2.0. Based on these results, it was concluded that the method of estimating the wave force by Kweon et al. (2011) can be satisfactorily used for estimating the uplift force of a pile.

주기적인 패턴 유리 기판을 사용한 비정질 실리콘 박막 태양전지의 효율 향상에 관한 연구 (Conversion Efficiency Enhancement of a-Si:H Thin-Film Solar Cell Using Periodic Patterned Substrate)

  • 손찬희;김경민;김재호;홍진;권기청
    • 한국진공학회지
    • /
    • 제21권1호
    • /
    • pp.55-61
    • /
    • 2012
  • 본 연구에서는 주기적인 3차원 패턴이 형성된 유리기판을 사용하여 비정질 실리콘 박막 태양전지를 제작하였다. 주기적인 패턴은 일반적인 전도성 투명 산화막(TCO: Trasparent Conductive Oxide) 표면의 불규칙 패턴과 비교하여 더 효율적인 광포획을 가능하게 한다. 태양전지 제작 전 광특성 전산모사를 통하여 주기적인 패턴 유리 기판의 광학적 특성을 알아보았다. 비정질 실리콘 박막 태양전지의 제작은 PECVD를 이용하여 구면 패턴이 형성된 유리기판을 이용하여 제작되었으며, 인공 태양광 조사장치를 이용하여 제작된 태양전지의 성능 평가를 진행하였다. 태양전지 전산모사 결과와 실험 결과들을 비교 분석하여 주기적인 패턴 유리 기판을 이용한 비정질 실리콘 박막 태양전지의 효율향상 가능성을 확인하였다.

일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교 (Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients)

  • 석효현;권근용;백승학;최태현;김석화
    • 대한두개안면성형외과학회지
    • /
    • 제14권1호
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

Fe가 첨가된 반절연성 InP에서 Photoreflectance에 관한 연구 (A study on photoreflectance in Fe-doped semi-insulating InP)

  • 김인수;이정열;배인호
    • 한국진공학회지
    • /
    • 제6권3호
    • /
    • pp.249-254
    • /
    • 1997
  • Fe가 첨가된 반절연성 InP(100)의 특성을 photoreflectance(R) 측정으로 조사하였다. 관측한 PR 신호로부터 300K에서 띠간격 에너지($E_o$)와 넓어지기 변수(broadening parameter:$\Gamma$)는 각각 1.336eV 및 11.2meV의 값을 얻었다. 측정온도를 300~80K로 낮춤에 따라 PR 신호는 엑시톤과 2차원의 띠사이 전이가 중첩된 형태(300K)에서 전형적인 엑시톤 에 의한 전이형태(80K)로 변함을 알았다. 또한 Varshni 계수 $\alpha=-0.94\pm$0.07meV/K, $\beta=587\pm$35.2K와 Bose-Einstein 계수 aB=33.6$\pm$2.02meV, $\theta=165\pm$33K의 값을 얻었다. 그리고 등온 및 등시 열처리를 수행한 후 측정 결과, 온도 $300^{\circ}C$에서 10~20분 정도 열처리시켰을 때 InP 시료의 결정성이 가장 좋아짐을 정성적으로 알 수 있었다.

  • PDF

13A 가스기기 새 가스호환성 판정법 (New Method for Estimating Gas Interchangeability for 13A Gas Appliances)

  • 하영철;박세종;박원식;최경석;이창언
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.961-967
    • /
    • 2011
  • 본 연구에서는 13A 가스기기의 새 가스호환성 판정법을 개발하고자 하였다. 호환성 판정법 개발의 원칙은 세 가지로서, 1) 웨버지수 외에 가스조성 영향을 대표할 수 있는 인자의 도출, 2) 우리나라 가정과 업소에 보급된 모든 종류의 제작사별 가스기기(예혼합 가스기기 포함) 시험, 3) 가능한 한 간단한 판정법 개발이다. 이러한 원칙하에 30대의 대표성 있는 가스기기에 대하여 가스호환성 실험을 하였고 그 결과 웨버지수-비중 형식의 간단한 2차원 판정법(도표)을 개발하였다. 본 호환성 판정법은, 기존 호환성 판정법과 달리 화염안정 영역이 좁은 예혼합 가스기기를 포함하며, 이로 인해 기존 호환성 판정법보다 가스호환성 영역이 좁은 것으로 나타났다.

3D 콘텐츠 깊이 측정기를 이용한 오브젝트의 돌출거리 측정 (Measuring Perceived Depth For The Object Using 3D Content Depth Measuring Instrument)

  • 한동희;강행봉;김석호
    • 한국멀티미디어학회논문지
    • /
    • 제16권9호
    • /
    • pp.1109-1118
    • /
    • 2013
  • 최근 들어 S3D 콘텐츠가 광범위하게 대중화되고 있다. 하지만, 일부의 사람들은 3D 정보를 정확하게 인지하지 못하고 있다. 기존의 입체시 검사 도구는 입체의 인지 여부를 판단하는 테스트만 수행하고, 피험자가 인지하는 정확한 깊이 정보를 측정할 수 없다. 따라서 정확하게 측정할 수 있는 검사도구가 필요하다. 본 논문에서는 3D 콘텐츠 깊이 측정기 및 측정기에 적합한 3D 콘텐츠를 제작하고, 3D 오브젝트의 양안시차(disparity)에 대한 피험자가 인지하는 3D 오브젝트의 돌출거리를 측정하고, 이론값(예측값)과 측정값을 비교 및 관계를 분석하였다. 그 결과 측정값은 이론값보다 약간 크게 나타났으며, 돌출거리가 클수록 편차가 크게 나타났다.

코일철근의 표면 거칠기 물리량 평가 기술 (An Evaluation Technique of Surface Roughness of Corroded Reinforcing Bar-in-Coils)

  • 노영숙;조강우
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6551-6557
    • /
    • 2015
  • 철근부식에 의해 발생된 녹은 철근 주변의 콘크리트에 팽창 압력을 유발하여 콘크리트의 균열, 피복콘크리트의 박리나 탈락, 철근의 단면적 감소 등 구조물의 내구성에 부정적인 영향을 끼친다. 본 논문에서는 코일철근을 대상으로 3차원 스캐너를 이용하여 철근이 부식됨에 따른 표면적을 측정하여 철근의 부식률과 표면 거칠기와의 관계를 프랙탈 이론을 이용하여 규명하였다. 코일 철근은 현장 적재일이 길수록 부식률이 증가하였으며, 부식률이 증가할수록 표면 거칠기는 거칠게 평가되었다. 프랙탈 차원의 증가량은 적재일 3일, 7일, 14일, 21일 경우 각각 0.0235, 0.0280, 0.0319, 그리고 0.0455로 나타났다. 이때의 부식률은 각각 0.3367%, 0.6127%, 0.7898%, 그리고 1.1965%로 나타나 프랙탈 차원을 이용한 부식된 코일철근의 표면 물리량 평가는 실제 부식률과 유사한 결과를 나타냈다.

2007년 3월 31일 서해안에 발생한 이상파랑에 대한 원인 분석 (Analysis of Abnormal Wave at the West Coast on 31 March 2007)

  • 엄현민;승영호;우승범;유승협
    • 한국해안·해양공학회논문집
    • /
    • 제24권3호
    • /
    • pp.217-227
    • /
    • 2012
  • 2007년 3월 31일에 영광을 비롯한 한반도 서해안에 발생한 이상파랑의 발생 원인을 관측자료와 수치모델을 이용하여 분석하였다. 사용된 자료는 조위 관측소에서 관측된 조위 자료와 AWS의 해면기압 자료로서 모두 1분 간격의 시계열 자료이다. 이러한 시계열 자료를 시간과 주기에 대한 에너지 성분으로 변환시켜줄 수 있는 웨이블렛 변환을 이용하여 이상파랑과 같이 단기적으로 불규칙하게 발생하는 변화를 분석하였다. 분석 결과를 이용하여 이상파랑의 도달시간과 진행방향을 도출하였고, 생성원인을 분석하기 위해 AWS 자료를 통해 기압 점프의 크기와 주기 및 진행방향에 대해 조사하였다. 3시간 간격의 분석일기도에 제시된 기압 분포를 이용하여 서해상에서 기압 점프의 이동 패턴을 유추하였다. 분석된 결과의 타당성을 검증하기 위해 2차원 수치모형을 이용하여 이상파랑에 대한 모의를 수행하였다. 기압 점프의 진행에 따라 발생된 해수면의 변동은 공진작용에 의해 수위가 증가하는 것으로 나타났다. 산정된 수위는 관측값과 비교할 때 과소 산정되는 것으로 나타났으나, 웨이블릿 변환을 통해 분석한 도달순서와 유사하게 수위 관측지역에 도달하는 것으로 산정되었다.

Validity of a Portable APDM Inertial Sensor System for Stride Time and Stride Length during Treadmill Walking

  • Tack, Gye Rae;Choi, Jin Seung
    • 한국운동역학회지
    • /
    • 제27권1호
    • /
    • pp.53-58
    • /
    • 2017
  • Objective: The purpose of this study was to compare the accuracy of stride time and stride length provided by a commercial APDM inertial sensor system (APDM) with the results of three dimensional motion capture system (3D motion) during treadmill walking. Method: Five healthy men participated in this experiment. All subjects walked on the treadmill for 3 minutes at their preferred walking speed. The 3D motion and the APDM were simultaneously used for extracting gait variables such as stride time and stride length. Mean difference and root mean squared (RMS) difference were used to compare the measured gait variables from the two measurement devices. The regression equation derived from the range of motion of the lower limb was also applied to correct the error of stride length. Results: The stride time extracted from the APDM was almost the same as that from the 3D motion (the mean difference and RMS difference were less than 0.0001 sec and 0.0085 sec, respectively). For stride length, mean difference and RMS difference were less than 0.1141 m and 0.1254 m, respectively. However, after correction of the stride length error using the derived regression equation, the mean difference and the RMS difference decreased to 0.0134 m and 0.0556 m or less, respectively. Conclusion: In this study, we confirmed the possibility of using the temporal variables provided from the APDM during treadmill walking. By applying the regression equation derived only from the range of motion provided by the APDM, the error of the spatial variable could be reduced. Although further studies are needed with additional subjects and various walking speeds, these results may provide the basic data necessary for using APDM in treadmill walking.