• Title/Summary/Keyword: 1-dimensional measurement

Search Result 742, Processing Time 0.026 seconds

An Intercity Compararive Study of Qual ity of Life in Korea : A Mulit-Year$\cdot$Mulit-Dimensional Diatance Index Model Approach (다년도$\cdot$다차원 거리지표 모형을 이용한 한국 도시의 삶의 질 비교연구)

  • 김재홍;이은우;이재기
    • Journal of the Korean Regional Science Association
    • /
    • v.14 no.1
    • /
    • pp.21-45
    • /
    • 1998
  • Urban quality of life(QOL) is recently considered as the important determinant of inter-urban migration and industrial location chice. However, there is little concensus in the method of measurement of QOL. This study provides an theoretical framework of the measurement of QOL. This study provides an theoretical framework of the measurement of QOL, and developes a new method, a multi-year$\cdot$mulit-dimensional distance index model. Based on the theoretical framework and the method, the QOLs of 74 urban areas in Korea are measured, and the determinants of the QOL and the changes of the QOL between two years of 1993 and 1995 are analyzed. The results of the analysis are as follows: 1) The interurban differences of the QOL tens to be interban differences of the QOL tend to be intensified over time. 2) The OQLs of the cities in the Capital Region are relatively deteriorated. 3) The conditions of education$\cdot$Culture$\cdot$leisure life determiner over 65% of the QOL of the Korean cities.

  • PDF

Dimensional Measurement of Spent Fuel Assemblies Using Image Processing Technique (영상처리기술에 의한 사용후핵연료 집합체의 제원 측정)

  • Koo, Dae-Seo;Park, Seong-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • A pool image processing measurement method has been developed to improve the examination efficiency and to minimize the errors of dimensional measurements of spent fuel assemblies in pool. Diameter and length measurements of mock-up fuel rods using the image processing system are $-0.24{\pm}0.03mm,\;0.34{\pm}0.06mm$ on the basis of the true value and their maximum errors are within -0.3 and 0.4mm, respectively, According to the result of dimensional measurement of spent fuels in pool, the upper and lower part diameter and mid part diameter of fuel rods of the J44 fuel assembly irradiated for 2 cycles in the Kori-2 nuclear reactor were decreased by about 2.0 and 3.0% in comparison with design values, respectively. The length of fuel rods was elongated by about 0.4%. The change behavior of diameter and length. of fuel rods of the F02 fuel assembly irradiated for 3 cycles in the Kori-1 nuclear reactor showed a trend similar to the results of J44.

Range Alignment Measurement for Satellite Antenna by Using Theodolite System (데오드라이트 시스템을 이용한 위성 안테나 레인지 얼라인먼트 측정)

  • Park, Hong-Cheol;Son, Yeong-Seon;Yun, Yong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.134-141
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system, The range alignments of the Ku-band and Ka-band antennas have been accomplished within the requirements, ${\pm}1mm\;and\;{\pm}0.05^{\circ}$.

Precision Evaluation of Three-dimensional Feature Points Measurement by Binocular Vision

  • Xu, Guan;Li, Xiaotao;Su, Jian;Pan, Hongda;Tian, Guangdong
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.30-37
    • /
    • 2011
  • Binocular-pair images obtained from two cameras can be used to calculate the three-dimensional (3D) world coordinate of a feature point. However, to apply this method, measurement accuracy of binocular vision depends on some structure factors. This paper presents an experimental study of measurement distance, baseline distance, and baseline direction. Their effects on camera reconstruction accuracy are investigated. The testing set for the binocular model consists of a series of feature points in stereo-pair images and corresponding 3D world coordinates. This paper discusses a method to increase the baseline distance of two cameras for enhancing the accuracy of a binocular vision system. Moreover, there is an inflexion point of the value and distribution of measurement errors when the baseline distance is increased. The accuracy benefit from increasing the baseline distance is not obvious, since the baseline distance exceeds 1000 mm in this experiment. Furthermore, it is observed that the direction errors deduced from the set-up are lower when the main measurement direction is similar to the baseline direction.

A New Method of Noncontact Measurement for 3D Microtopography in Semiconductor Wafer Implementing a New Optical Probe based on the Precision Defocus Measurement (비초점 정밀 계측 방식에 의한 새로운 광학 프로브를 이용한 반도체 웨이퍼의 삼차원 미소형상 측정 기술)

  • 박희재;안우정
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-137
    • /
    • 2000
  • In this paper, a new method of noncontact measurement has been developed for a 3 dimensional topography in semiconductor wafer, implementing a new optical probe based on the precision defocus measurement. The developed technique consists of the new optical probe, precision stages, and the measurement/control system. The basic principle of the technique is to use the reflected slit beam from the specimen surface, and to measure the deviation of the specimen surface. The defocusing distance can be measured by the reflected slit beam, where the defocused image is measured by the proposed optical probe, giving very high resolution. The distance measuring formula has been proposed for the developed probe, using the laws of geometric optics. The precision calibration technique has been applied, giving about 10 nanometer resolution and 72 nanometer of four sigma uncertainty. In order to quantitize the micro pattern in the specimen surface, some efficient analysis algorithms have been developed to analyse the 3D topography pattern and some parameters of the surface. The developed system has been successfully applied to measure the wafer surface, demonstrating the line scanning feature and excellent 3 dimensional measurement capability.

  • PDF

3-Dimensional analysis for class III malocclusion patients with facial asymmetry

  • Kim, Eun-Ja;Ki, Eun-Jung;Cheon, Hae-Myung;Choi, Eun-Joo;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.39 no.4
    • /
    • pp.168-174
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the correlation between 2-dimensional (2D) cephalometric measurement and 3-dimensional (3D) cone beam computed tomography (CBCT) measurement, and to evaluate the availability of 3D analysis for asymmetry patients. Materials and Methods: A total of Twenty-seven patients were evaluated for facial asymmetry by photograph and cephalometric radiograph, and CBCT. The 14 measurements values were evaluated and those for 2D and 3D were compared. The patients were classified into two groups. Patients in group 1 were evaluated for symmetry in the middle 1/3 of the face and asymmetry in the lower 1/3 of the face, and those in group 2 for asymmetry of both the middle and lower 1/3 of the face. Results: In group 1, significant differences were observed in nine values out of 14 values. Values included three from anteroposterior cephalometric radiograph measurement values (cant and both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). In group 2, comparison between 2D and 3D showed significant difference in 10 factors. Values included four from anteroposterior cephalometric radiograph measurement values (both maxillary height, both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). Conclusion: Information from 2D analysis was inaccurate in several measurements. Therefore, in asymmetry patients, 3D analysis is useful in diagnosis of asymmetry.

A Study on the Fabrication and Comparison of the Phantom for Computed Tomography Image Quality Measurements Using Three-Dimensions Printing Technology (삼차원 프린팅 기술을 이용한 전산화단층영상 품질 측정용 팬텀 제작 및 비교 연구)

  • Yoon, Myeong-Seong;Hong, Soon-Min;Heo, Yeong-Cheol;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.595-602
    • /
    • 2018
  • Quality control (QC) of Computed Tomography (CT) devices is based on image quality measurement on AAPM CT phantom which is a standard phantom. Although it is possible to control the accuracy of the CT apparatus, it is expensive and has a disadvantage of low penetration rate. Therefore, in this study, we make image quality measurement phantom at low cost using FFF (Fused Filament Fabrication) type three-dimensional printer and try to analyze the usefulness, compare it with existing standard phantom. To print a phantom, We used three-dimensional printer of the FFF system and PLA (Poly Lactic Acid, density: $1.24g/cm^3$) filament, and the CT device of 64 MDCT (Aquilion CX, Toshiba, Japan). In addition, we printed a phantom using three-dimensional printer after design using various tool based on existing standard phantom. For image quality evaluation, AAPM CT phantom and self-generated phantom were measured 10 times for each block. The measured data were analyzed for significance using the Mannwhiteney U-test of SPSS (Version 22.0, SPSS, Chicago, IL, USA). As a result of the analysis, phantom fabricated with three-dimensional printer and standard phantom showed no significant difference (p>0.05). Furthermore, we confirmed that image quality measurement performance of a phantom using three-dimensional printer is similar to the existing standard phantom. In conclusion, we confirmed the possibility of low cost phantom fabrication using three dimensional printer.

The Database Development of 2-D and 3-D Hands Measurement for Improving Fitness of Gloves - Focused on the Classification of Hand Type and Analysis of 3-D Hand Shape - (장갑의 적합성 향상을 위한 손부의 2차원 및 3차원 계측정보 DB구축에 관한 연구 -손의 유형분석 및 3차원 입체형상 분석을 중심으로-)

  • 최혜선;김은경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.910
    • /
    • pp.1300-1311
    • /
    • 2004
  • The aim of this study was to provide the 2 and 3 dimensional statistics requisite in the sizing system and design of gloves. The 64 2-dimensional static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. To summarize the information from the measurement values, a Factor Analysis and a Cluster Analysis among multivariate analyses were performed. 3-D scanner was used for visual results of hand shape of each cluster. The results were as follows. Twenty-two items were used for the factor and cluster analysis in order to classify the adult hand shape. The variable quantities that are explained by a total of 3 factors amounted to under 79.37% of the variable quantities. The definition results of the factors related to the hands are as follows: Factor 1 is the horizontal dimension, the thickness of hand factor; Factor 2 is the height of the crotch; and Factor 3 is the vertical dimension of the hand. The adults' group hand was divided into 2 clusters according to a cluster analysis using factor scores. The characteristics according to hand type were as follows: Cluster 1 referred to high horizontal dimensions and thickness, rather small vertical dimensions and crotch height; and Cluster 2 represented the rather smaller horizontal dimensions and thickness but longer hand length than Type 1. To provide specific shape data of each cluster, 3-D scanner measurement was performed. 3-dimensional data base was developed for each cluster type and visual information was provided.

A study on analysis of the structure of green space by the types of urban residential areas (도시내 주거지 유형별 녹지구조분석에 관한 연구)

  • 송태갑;김은일
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.25 no.3
    • /
    • pp.56-65
    • /
    • 1997
  • This research was conducted to suggest some directions for desirable urban green space planning through 1) establishing a new classification system by examining the existing concept, problems and characteristics of green space and 2) defining the essence of green space environment and finding some analytical and evaluative methods through a clear establishment of functions, indicators of green space. In the research, measurements of the amount of green space was accompanied with measurements of green covered space, green volume, and the structure of greenery within the frame of vision. As result, three-dimensional measurement was possible, three-dimensional measurement was possible, which turned out to be more effective than the existing 2-dimensional measuring method. It is found that the ratio of green covered space is to proportional to the ratio of green volume in this study. Therefore in green space planning process it is desirable to consider the ratio of green volume all together.

  • PDF

Profile Measurements of Micro-Machined Surfaces by Scanning Tunneling Microscopy (터널링효과를 이용한 초미세 가공표면의 형상측정)

  • Jung, Seung-Bae;Lee, Young-Ho;Kim, Seung-Woo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1731-1739
    • /
    • 1993
  • An application of Scanning Tunneling Microscopy(STM) is investigated for the measurement of 3-dimensional profiles of the macro-machined patterns of which critical dimensions lie in the range of submicrometers. Special emphasis of this investigation is given to extending the measuring ranges of STM upto the order of several micrometers while maintaining superb nanometer measuring resolution. This is accomplished by correcting hysteresis effects of piezoelectric actuators by using non-linear compensation models. Detailed aspects of design and control of a prototype measurement system are described with some actual measuring examples in which fine It patterns can successfully be traced with a resolution of 1 nanometer over a surface range of $4{\times}2$ micrometers.