• 제목/요약/키워드: 1-MX

검색결과 199건 처리시간 0.024초

약용식물추출물의 아토피성피부염에 대한 항염증 및 항알레르기효과(제 1보) (Anti-inflammatory and Anti-allergic Effects of Herbal Extracts on Atopic Dermatitis(Part I))

  • 랑문정
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.75-84
    • /
    • 2011
  • Atopic dermatitis is a chronic inflammatory skin disease associated with cutaneous hyper-reactivity to environmental triggers. In order to develop effective therapeutic herbal extracts for atopic dermatitis, cytotoxicity, antioxidant, anti-inflammatory and anti-allergic activities were investigated for various herbal extracts. Among candidate extracts, we selected Aloe vera L. (AV), Viola mandshurica W. Becker (VM), Punica granatum L. (PG), Dendrobium nobile L. (DN) and mixture of the above extracts (MX) for further investigations. All of them did not show cytotoxic activities to macrophage RAW264.7 cells below the concentration of 100 ppm. All showed antioxidant, anti-inflammatory and anti-allergic effects, although to various extents. In antioxidant effects, AV showed the highest effect, followed by PG and VM, while DN did the lowest. In evaluation for anti-inflammatory activities in macrophage RAW264.7 cells, AV and DN inhibited almost completely the LPS-induced production of nitric oxide, while AV, DN and VM showed strong inhibitory activities on the LPS-induced production of TNF-${\alpha}$. In anti-allergy effect in mast cell HMC-1, DN showed the highest effect, followed by AV and PG, while VM did the lowest. In the topical allergy reaction induced by compound 48/80 in Sprague-Dawley rat, DN exhibited significant anti-allergic effect, while PG, VM and AV did slight effect. These results suggest that AV, VM, PG and DN have antioxidant, anti-inflammatory and anti-allergic activities, and thus have the potential to reduce and alleviate the symptoms of atopic dermatitis.

Different Types of Active Region EUV Bright Points by Hinode/EIS

  • 이경선;문용재;김수진
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.28.2-28.2
    • /
    • 2010
  • We have investigated seven Extreme-Ultraviolet (EUV) bright points in the active region (AR 10926) on 2006 December 2 by the EUV imaging spectrometer (EIS) onboard Hinode spacecraft. We determined their Doppler velocities and non-thermal velocities from 15 EUV spectral lines (log T=4.7-7.2) by fitting each line profile to a Gaussian function. We present the Doppler velocity map as a function of temperature which corresponds to a different height. As a result, these active region bright points show two different types of characteristics. Type 1 bright point shows a systematic increase of Doppler velocity from -68 km/s (blue shift) at log T=4.7 to 27 km/s (red shift) at log T=6.7, while type 2 bright points have Doppler velocities in the range of -20 km/s and 20 km/s. Using MDI magnetograms, we found that only type 1 bright point was associated with the canceling magnetic feature at the rate of $2.4{\times}10^{18}$ Mx/hour. When assuming that these bright points are caused by magnetic reconnection and the Doppler shift indicates reconnection out flow, the pattern of the Doppler shift implies that type 1 bright point should be related to low atmosphere magnetic reconnection. We also determined electron densities from line ratio as well as temperatures from emission measure loci using CHIANTI atomic database. The electron densities of all bright points are comparable to typical values of active regions (log Ne=9.9-10.4). For the temperature analysis, the emission loci plots indicate that these bright points should not be isothermal though background is isothermal. The DEM analysis also show that while the background has a single peak distribution (isothermal), the EUV bright points, double peak distributions.

  • PDF

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

치은연하 치석제거와 치근면 활택술시 Gracey curet과 Mini-five curet의 치석제거 효과에 대한 비교 연구 (A Comparison of effectiveness of Gracey curet and Mini-five curet on subgingival scaling and root planing)

  • 장원혁;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제27권3호
    • /
    • pp.585-595
    • /
    • 1997
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, two types of anterior curet were used on ant. teeth to conduct subgingival scaling and root planing. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth extracted from patients being treated at Dan Kook University dept. Perio. were used. 4 surfaces per tooth a total of 96 areas were evaluated. 12 teeth treated with Gracey No. 1-2 was used as the control group and 12 teeth treated with Mini-five curet No. 1-2 was the experimental group. The 4 surfaces of the teeth {buccal, mesial, lingual or palatal, distal) were observed under a stereomicroscope and the images were captured 3 times per surfaced with a CCD. The image were observed on the monitor using a $10{\times]10$ grid produced with the Microsoft power point. The amount of calculus remaining was evaluated 3 times per surface. The results were as follows. 1. There was no significant difference in remaining calculus according to the pre-treatment pocket depth, and tooth position{Mx. or Mn). 2. The Mini-five curet showed better results than the Gracey curet but there was no statistically significant difference. 3. In both Gracey curet group and Mini-five curet group the lingual(or palatal) surface showed significant difference compared to the other surfaces(p<0.05). From the results above, it is thought that when treating ant. teeth consideration of the tooth surface is more important than the choice of instrument.

  • PDF

Comparison of media for a human peripheral blood mononuclear cell-based in vitro vaccine evaluation system

  • Shuran Gong;Putri Fajar;Jacqueline De Vries-Idema;Anke Huckriede
    • Clinical and Experimental Vaccine Research
    • /
    • 제12권4호
    • /
    • pp.328-336
    • /
    • 2023
  • Purpose: Human peripheral blood mononuclear cell (PBMC)-based in vitro systems can be of great value in the development and assessment of vaccines but require the right medium for optimal performance of the different cell types present. Here, we compare three commonly used media for their capacity to support innate and adaptive immune responses evoked in PBMCs by Toll-like receptor (TLR) ligands and whole inactivated virus (WIV) influenza vaccine. Materials and Methods: Human PBMCs were cultured for different periods of time in Roswell Park Memorial Institute (RPMI), Dulbecco's minimal essential medium (DMEM), or Iscove's modified DMEM (IMDM) supplemented with 10% fetal calf serum. The viability of the cells was monitored and their responses to TLR ligands and WIV were assessed. Results: With increasing days of incubation, the viability of PBMCs cultured in RPMI or IMDM was slightly higher than that of cells cultured in DMEM. Upon exposure of the PBMCs to TLR ligands and WIV, RPMI was superior to the other two media in terms of supporting the expression of genes related to innate immunity, such as the TLR adaptor protein gene MyD88 (myeloid differentiation factor 88), the interferon (IFN)-stimulated genes MxA (myxovirus resistance protein 1) and ISG56 (interferon-stimulated gene 56), and the leukocyte recruitment chemokine gene MCP1 (monocyte chemoattractant protein-1). RPMI also performed best with regard to the activation of antigen-presenting cells. As for adaptive immunity, when stimulated with WIV, PBMCs cultured in RPMI or IMDM contained higher numbers of IFNγ-producing T cells and secreted more immunoglobulin G than PBMCs cultured in DMEM. Conclusion: Taken together, among the different media assessed, RPMI was identified as the optimal medium for a human PBMC-based in vitro vaccine evaluation system.

Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가 (The reliability of the cephalogram generated from cone-beam CT)

  • 강지영;김광원;임성훈
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.391-399
    • /
    • 2007
  • 최근 computed tomography (CT) 데이터로부터 실제 두부계측방사선사진 촬영기에서 촬영한 사진과 동일한 확대율을 갖는 두부계측방사선사진을 형성할 수 있는 기능을 갖춘 소프트웨어(Accurex, CyberMed, Seoul, Korea)가 소개되었다. 이에 본 연구에서는 cone-beam CT (이하 CBCT) 데이터로부터 이 소프트웨어를 이용하여 제작된 측모 두부계측방사선사진과 기존의 두부계측방사선사진촬영기로 촬영된 측모 두부계측방사선사진에서 각각 두부계측방사선사진 분석을 시행하여 그 차이를 비교함으로써 소프트웨어를 통해 CBCT로부터 제작된 측모 두부계측방사선사진의 활용 가능성을 평가하고자 하였다. 20명의 교정 환자를 대상으로 CBCT와 측모 두부계측방사선사진을 동시에 촬영하였다. CBCT로부터 제작된 측모 두부계측방사선사진과 기존 방식의 측모 두부계측방사선사진에서 두부계측 방사선사진 분석을 시행한 후 두 사진의 계측치의 차이를 paired t-test로 검정하였다. 23개의 계측치들 중, 20개 항목에서는 통계학적으로 유의한 차이가 관찰되지 않았으나, U1-FH, Mx6 to PTV, Maxillomandibular difference의 항목에서는 유의한 차이가 나타났다 이러한 차이는 CBCT로부터 형성된 측모 두부계측방사선사진의 해상도가 낮아 일부 해부학적 지표를 확인하기 어렵기 때문이며, 임상에서 CBCT로부터 제작된 측모 두부계측방사선사진을 porion, PTV, condylion과 같은 일부 해부학적 지표를 이용하지 않는 SNA, SNB, U1 to SN, IMPA, interincisal angle 등 흔히 사용되는 간단한 측모 두부계측방사선사진 계측에 활용 가능할 것이다.선 병용요법은 절제 불가능한 원발성 간암의 증상호전 및 국소적 치료에 효과가 있는 것으로 생각되며 생존율 및 부작용 등에 관해서는 앞으로 연구가 더 진행되어야 할 것으로 생각된다.용 선형가속기의 전자선 방출구에 장착된 산란판과 조사면을 조정하는 cone에 의하여 발생되는 저 에너지 산란전자선이 alanine dosimeter에 측정된 것으로서 에너지가 증가될수록 오염 정도가 증가되었다. 본 실험을 통하여 지금까지 고에너지 전자선량계측에서 전리상에 의한 전기량 측정과 산란선이 없는 단일 에너지로만 간주하여 계산하였던 전자선 흡수선량 측정방법을 직접 흡수선량 측정이 가능한 Alanine/ESR dosimetry로서 교정하는 것이 바람직하다고 생각한다.$6\%$, 수술이 필요하였던 환자는 $1\%$로 합병증의 증가 없이 A점에 8900cGy, 직장에 7300cGy정도의 국소치료가 가능함을 보여 주었으나 생존율에 대한 추후 분석이 따라야 할 것으로 사료된다.보면 6,000rad이하에서 20/63$(34.9\%)$의 실패율에 비하여 6,000rad이상일 때는 10/49$(20.4\%)$의 실패율이었다. 연령 벨로는 $40\~49$세에서 실패율(14/41 $24.1\%$)이 많았다. 본 성적으로 보아서 생존율은 여러 저자들과 큰 차이가 없음을 알 수 있었고 A점 선량은 8,000rad 이상, B점은 6,000rad이상이 조사되어야 적정선량이 됨을 시사해 주고 있다.\%$가 대부분이 하루 세끼 식사를 규칙적으로 하고 있었으며 식사속도는 허겁지겁 빨리 섭취하는 경우가 남자는 $31.0\%$,

선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰 (The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator)

  • 임충근;김회남;송기원
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF

낙동강 수계에서의 인공 사향물질 검출 특성 (Detection of Synthetic Musk Compounds (SMCs) in Nakdong River Basin)

  • 서창동;손희종;이인석;오정은
    • 대한환경공학회지
    • /
    • 제32권6호
    • /
    • pp.615-624
    • /
    • 2010
  • 낙동강 수계에서의 인공 사향물질들의 검출현황을 조사한 결과, 다환 사향물질인 HHCB, AHTN, AHMI 및 ADBI 4종과 염화 사향물질인 MK 1종이 검출었으며, 본류에서는 HHCB, AHTN 및 MK 3종만이 검출되었다. 낙동강 수계에 검출된 인공 사향물질들의 구성비율을 조사한 결과, HHCB가 50% 이상을 차지하여 가장 높게 나타났고, 다음으로 MK와 AHTN이 높은 비율을 나타내었다. 낙동강 본류에서 가장 높은 검출농도를 나타낸 지점은 고령지점 (고령교)으로 2월과 9월에 각각 280.4 ng/L와 195.3 ng/L가 검출되었고, 지류에서는 진천천 지점으로 2월에 2146.6 ng/L와 9월에 1386.4 ng/L의 검출농도를 나타내었다. 인공 사향물질들은 낙동강 상류부근에서는 거의 검출되지 않았으나 중류부근인 구미 지점부터 하수처리장 방류수의 영향을 받아서 농도가 증가하였고, 금호강과 진천천 (hot spot)의 영향을 많이 받는 고령지점에서 최대농도를 나타낸 후 하류로 갈수록 희석효과에 의해 농도가 점점 감소하였다.

Dependence of the lithium ionic conductivity on the B-siteion substitution in $(Li_{0.5}La_{0.5})Ti_{1-x}M_xO_3$

  • Kim, Jin-Gyun;Kim, Ho-Gi
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권11호
    • /
    • pp.9-17
    • /
    • 1998
  • The dependence of the ionic conductivity on the B-site ion substitution in (Li0.5La0.5)Ti1-xMxO3 (M=Sn, Zr, Mn, Ge) system has been studied. Same valence state and various electronic configuration and ionic radius of Sn4+, Zr4+, Mn4+ and Ge4+(4d10(0.69$\AA$), 4p6(0.72$\AA$), 3d10(0.54$\AA$) and 3d3(0.54$\AA$), respectively) induced the various crystallographic variaton with substitutions. So it was possibleto investigate the crystallographic factor which influence the ionic conduction by observing the dependence of the conductivity on the crystallographic factor which influence the ionic conduction by observing the dependence of the conductivity on the crystallographic variations. We found that the conductivity increased with decreasing the radii of B-site ions or vice versa and octahedron distortion disturb the ion conduction. The reason for this reciprocal proportion of conductivity on the radius of B-site ions has been examined on the base of the interatomic bond strength change due to the cation substitutions. The results were good in agreement with the experimental results. Therefore it could be concluded that the interatomic bond strength change due to the cation substitutions may be the one of major factors influencing the lithium ion conductivity in perovskite(Li0.5La0.5) TiO3system.

  • PDF

Effects of a 12-week Combined Exercise Program on Gait Parameters in Elderly Women with Osteoarthritis

  • Lee, Jin
    • 한국운동역학회지
    • /
    • 제28권4호
    • /
    • pp.227-236
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effects of a 12-week combined exercise program on gait parameters in elderly women with osteoarthritis. Method: The subjects of this study were 11 elderly women (age: $67.09{\pm}2.47$, height: $157.35{\pm}4.30cm$, weight: $62.49{\pm}6.36kg$) with knee osteoarthritis. The combined exercise program of this study was divided into aerobic exercise and lower extremity strengthening exercises. The exercises were performed for 60 minutes per session, three times a week, for a total of 12 weeks. The maximum joint moments of the hip, knee, and ankle joints with walking were obtained with 8-3D cameras (MX-T20, Vicon, USA) and 2-force plate (AMTI OR6-7-400, AMTI, USA). SPSS Windows version 23.0 was used for statistical analysis. A paired t-test was used for pre-post comparison. An alpha level of .05 was utilized in all tests. Results: The maximum extension moment was significantly higher in the hip joint after P1 on the X axis. The maximum joint moment of P3 in extension was statistically significantly lower after intervention. On the Z axis, the maximum joint moment was significantly lower after the exercise intervention at P3. There was a statistically significant increase in the extension moment of the left and right knee joints in the X axis after exercise intervention. In the right ankle joint, P1 (plantar flexion moment) showed a statistically significant high moment after exercise intervention. Conclusion: These results suggest that combined exercise, including lower limb and aerobic exercise, may have a positive effect on mobility and walking moments in patients with osteoarthritis of the knee.