• Title/Summary/Keyword: 1-D Simulation

Search Result 3,654, Processing Time 0.044 seconds

Characteristics of Run-up Height over Sandy Beach with Submerged Breakwaters : PART I - Effect of Plane Arrangement of Submerged Breakwaters (잠제 설치 연안의 처오름 높이 특성 : PART I - 잠제의 평면배치에 의한 영향)

  • Hur, Dong-Soo;Lee, Woo-Dong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.345-354
    • /
    • 2008
  • In this present study, we made a first attempt to investigate physical transformations of incident waves in surf and swash zone and hydrodynamic phenomena of detached and submerged breakwaters. For an accurate simulation of the complicated wave deformation, Three-Dimensional numerical model with Large Eddy Simulation has been developed recently and expanded properly for the current applications, which is able to simulate an accurate and direct WAve Structure Sandy seabed interaction (hereafter, LES-WASS-3D). LES-WASS-3D has been validated through the comparison with experimental results for limited cases, and has been used for the simulation of wave run-up on sandy beach, mean fluid flows over and around submerged structures and swash zone (alongshore/rip current), and spatial distribution of wave height in wide fluid regions. In addition, a strategy of efficient deployment ($Y/L_i=1.50{\sim}1.75$, $W/L_r=0.50$) of the submerged breakwaters has been discussed.

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Design of a TIQ Based CMOS A/D Converter for Real Time DSP (실시간 디지털 신호처리를 위한 TIQ A/D 변환기 설계)

  • Kim, Jong-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.205-210
    • /
    • 2007
  • This paper presents a CMOS TIQ flash A/D converter which operates very fast compared to other types of A/D converters due to its parallel architecture. The output resolution of designed A/D converter is 6-bit. In order to reduce the power consumption and chip area of conventional flash A/D converter, TIQ based flash A/D converter is proposed, which uses the advantage of the structure of CMOS transistors. The length and width of transistors of TIQ were determined with HSPICE simulation. To speed up the ultra-high speed flash A/D converter, the Fat Tree Encoder technique is used. The TIQ A/D converter was designed with full custom method. The chip's maximum power consumption was 38.45mW at 1.8V, and the operating speed of simulation was 2.7 GSPS.

  • PDF

Hybrid d-step prediction design with improved prediction performance (향상된 성능을 갖는 혼합 d-step 예측기 설계)

  • 김윤선;윤주홍;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.145-145
    • /
    • 2000
  • In this paper, we propose a hybrid d-step predictor which is composed of an adaptive predictor and a Kalman predictor. We prove the performance limit of the proposed predictor. Simulation is conducted to examine the performance of the proposed predictor. Simulation results show that the proposed combined predictor is superior to the adaptive predictor and the Kalman predictor. Proposed predictor is used for prediction of gun tip vibration of k1 tank. The result is compared with that of conventional adaptive predictor.

  • PDF

The Effects of Crime Prevention on the Improvement of the Physical Environment in Scene of Child Sex Offense by Using 3D Simulation (아동성범죄 발생지의 3D 시뮬레이션을 이용한 물리적 환경 개선양상에 따른 범죄예방 효과분석)

  • Kim, A-Ram;Jung, Sung-Won;Jun, Han-Jong
    • Journal of the Korean housing association
    • /
    • v.25 no.1
    • /
    • pp.23-32
    • /
    • 2014
  • This research progressed space evaluation test with 3D simulation for exterior space of detached housing area among the Seoul spaces of child sex offense in 2010. Based on changing analysis on natural surveillance by spatial changes of each physical element, the purpose is to suggest effective construction planning measure for preventing child sex offense. The results of research are as follows. First, natural surveillance of space's height differences and width differences were compared and analyzed. As the result, footpath shows that stairs of slope didn't make lots of effects on visual block, not block of spatial moving, because of the difference of stair height. Also, in case of parking space, visual connection with footpath is expanded when designing pilotis rather than heightening floor height, so activities of exterior people could be seen more easily. Therefore, natural surveillance was higher. Second, natural surveillance of architectural elements by changes of footpath' width was compared and analyzed. As the result, openness of footpath should be secured rather than openness of architectural element. And, planning autonomy of architectural form could be more expanded when securing openness of footpath.

Unscented Kalman Snake for 3D Vessel Tracking

  • Lee, Sang-Hoon;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose In this paper, we propose a robust 3D vessel tracking algorithm by utilizing an active contour model and unscented Kalman filter which are the two representative algorithms on segmentation and tracking. Materials and Methods The proposed algorithm firstly accepts user input to produce an initial estimate of vessel boundary segmentation. On each Computed Tomography Angiography (CTA) slice, the active contour is applied to segment the vessel boundary. After that, the estimation process of the unscented Kalman filter is applied to track the vessel boundary of the current slice to estimate the inter-slice vessel position translation and shape deformation. Finally both active contour and unscented Kalman filter are inter-operated for vessel segmentation of the next slice. Results The arbitrarily shaped blood vessel boundary on each slice is segmented by using the active contour model, and the Kalman filter is employed to track the translation and shape deformation between CTA slices. The proposed algorithm is applied to the 3D visualization of chest CTA images using graphics hardware. Conclusion Through this algorithm, more opportunities, giving quick and brief diagnosis, could be provided for the radiologist before detailed diagnosis using 2D CTA slices, Also, for the surgeon, the algorithm could be used for surgical planning, simulation, navigation and rehearsal, and is expected to be applied to highly valuable applications for more accurate 3D vessel tracking and rendering.

Galaxy identification with the 6D friends-of-friend algorithm for high resolution simulations of galaxy formation

  • Rhee, Jinsu;Elahi, Pascal;Yi, Sukyoung K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.42.1-42.1
    • /
    • 2021
  • Galaxy/Halo finding based on the friends-of-friend (FoF) algorithm has been widely adopted for its simplicity and expandability to the phase-space. However, cosmological simulations have been progressively bigger in size and more accurate in resolutions, resulting in that galaxy/halo finding gets computationally expensive more and more. In fact, we confirm this issue through our exercise of applying the 6-dimensional (6D) FoF galaxy finder code, VELOCIraptor (Elahi et al.2019) on the NewHorizon simulation (Dubois et al. 2021), in which typical galaxies with about 1e11 Msun (107 particles) are identified with very low speed (longer than a day). We have applied several improvements to the original VELOCIraptor code that solve the low-performance problem of galaxy finding on a simulation with high resolutions. Our modifications find the exact same FoF group and can be readily applied to any tree-based FoF code, achieving a 2700 (12) times speedup in the 3D (6D) FoF search compared to the original execution. We applied the updated version of VELOCIraptor on the entire NewHorizon simulation (834 snapshots) and identified its galaxies and halos. We present several quick comparisons of galaxy properties with those with GALAXYMaker data.

  • PDF

Housing optimal design researches of DC-DC converter for HEV (HEV용 DC-DC 컨버터의 하우징 최적 설계 연구)

  • Kim, Yun-Sung;Seo, Ki-Bong;Lee, Yong-Hwa;Baeg, Byung-Dug
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.927_929
    • /
    • 2009
  • This paper reports the case that unitizes heat analysis simulation in housing design of DC-DC converter. Icepak4.3 is used for heat analysis simulation program. 1.5kW prototype is produced with base of finally selected structure through simulation and is compared heating characteristic. Propriety of development application is confirmed through the result, shortening case of development cost and period is introduced.

  • PDF