• Title/Summary/Keyword: 1 wall defect

Search Result 217, Processing Time 0.019 seconds

Value of Porous Titanium Alloy Plates for Chest Wall Reconstruction after Resection of Chest Wall Tumors

  • Qi, Yu;Li, Xin;Zhao, Song;Han, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4535-4538
    • /
    • 2014
  • Objective: To explore the value of porous titanium alloy plates for chest wall reconstruction after resection of chest wall tumors. Materials and Methods: A total of 8 patients with chest wall tumors admitted in our hospital from Jan. 2006 to Jan. 2009 were selected and underwent tumor resection, then chest wall repair and reconstruction with porous titanium alloy plates for massive chest wall defects. Results: All patients completed surgery successfully with tumor resection-induced chest wall defects being $6.5{\times}7cm{\sim}12{\times}15.5$ cm in size. Two weeks after chest wall reconstruction, only 1 patient had subcutaneous fluidify which healed itself after pressure bandaging following fluid drainage. Postoperative pathological reports showed 2 patients with costicartilage tumors, 1 with squamous cell carcinoma of lung, 1 with lung adeno-carcinoma, 1 with malignant lymphoma of chest wall, 2 with chest wall metastasis of breast cancers and 1 with chest wall neurofibrosarcoma. All patients had more than 2~5 years of follow-up, during which time 1 patient with breast cancer had surgical treatment due to local recurrence after 7 months and none had chest wall reconstruction associated complications. The mean survival time of patients with malignant tumors was ($37.3{\pm}5.67$) months. Conclusions: Porous titanium alloy plates are safe and effective in the chest wall reconstruction after resection of chest tumors.

Aortopulmonary Window -Report of A Case- (폐동맥 대동맥 중격결손증 1례 보고)

  • 박기진
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.721-725
    • /
    • 1995
  • One case of surgical correction of a large aortopulmonary window in a 4 months old female is reported in detail. Clinical symptoms consisted of fatigue when feeding and recurrent upper respiratory tract infection. Under cardiopulmonary bypass with moderate hypothermia and cardioplegic arrest of the heart, the aortopulmonary window was approached through a vertical incision at the anterior wall of window itself. The defect was closed with pericardial patch using continuous suture posteriorly and sandwitch technique anteriorly. The patient was weaned from the cardiopulmoanry bypas without hemodynamic problem and postoperative course was uneventful. This surgical technique is recommandable as it provides good exposure of the defect and can be performed easily and safely.

  • PDF

Right Atrial Angiosarcoma -One Case Rreport- (우심방 맥관육종 -1례 보고-)

  • 박진상
    • Journal of Chest Surgery
    • /
    • v.28 no.7
    • /
    • pp.713-716
    • /
    • 1995
  • A 75-year-old man was admitted to the hospital because of a pericardial effusion.After 3 L of blood-stained pericardial fluid was drained, clinical examination together with echocardiography and chest computed tomography showed a tumor in the right atrium. At operation a pedunculated vascular tumor was found with a broad base which was embedded in the atrial wall and extended into the pericardium.A wide resection was performed resulting in a large defect of the right atrial wall. The defect was reconstructed with a pericardial patch. The patient did well postoperatively, but bloody pleural effusion developed later, presumably because of pulmonary metastasis. The patient died 2 months after surgery as a result of respiratory failure.

  • PDF

Modified Direct W-incision with Silicone Sheet to Minimize Operation Scar in Reconstruction of Mild to Moderate Symptomatic Medial Orbital Wall Fracture (경중도 안와 내벽 골절의 수술 시 흉터 최소화를 위한 변형된 직접 W-절개법과 실리콘판을 이용한 재건)

  • Jung, Jae A;Gong, Jung Sik;Kim, Yang Woo;Kang, So Ra
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.30-35
    • /
    • 2013
  • Background: For reconstruction of the mild to moderate medial orbital wall fractures, various surgical approaches have been used. Prior existing W-shaped incision was a direct local approach through a 3 cm incision on the superior medial orbital area with a titanium mesh implant. In this study, the authors modified W-shaped incision and reconstructed the defect with silastic sheet to improve the result and the postoperative scar. Methods: This study included 20 patients who had mild to moderate size of medial wall defect and therefore relatively suitable for reconstruction with silastic sheets from July, 2009 to December, 2011. A modified W-shaped skin incision approximately 1.2 to 1.5 cm in length was made along the superior medial orbital rim from approximately 1 cm medial to the medial canthus to the lower border of the medial eyebrow. The angles of the limbs of the W ranged from 150 to 160 degrees. Results: By using soft flexible silastic sheet, the authors reduced the incision from 3 to 1.5 cm, and by widening the angle of the W limbs, scars were more effectively hided in the relaxed skin tension line. Scar assessment was done with modified patient and observer scar assessment scale and mean score from patients was 2.08 and mean score from observers was 2.12. Conclusion: Although this method will not be suitable for every case, it can be a consistent method to obtain the surgical goal in treatment of mild to moderate blowout fractures of the medial orbital wall.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Eddy Current and Ultrasonic IRIS Signal Characteristics of Reboiler Tube by Using STS 316L Calibration Specimen (STS 316L 교정시험편을 이용한 재가열기 튜브의 와전류신호와 초음파 IRIS 신호 특성)

  • Tak, Kyeong-Joo;Kim, Byung-Il;Gook, Jin-Seon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.56-63
    • /
    • 2012
  • In this study, a field applicability of reboiler tube was evaluated by comparing ECT signal with IRIS signal about wall loss rate and remaining wall thickness using worked austenite STS 316L ASME standard calibration tube. In the case of wall-loss rate, as a result, tolerance about $20%{\times}4$ flat bottom hole and 10% O D groove(ECT), 80% defect and 10% O D groove(IRIS) occurred up to ${\pm}15%$. In the case of remaining wall thickness, ECT was satisfied with the both tolerance, but tolerance about 80% defect occurred up to ${\pm}15%$ in IRIS. Therefore, if the IRIS is performed for interpretation of non-relevant indication and measurement of wall-loss rate after ECT, reliability is supposed to be improved.

Malignant lymphoma [non-Hodgkin`s lymphoma] at left posterior chest wall (흉벽에 발생한 악성 임파종 [Non-Hodgkin`s lymphoma] 수술 치험 1예)

  • 김송명
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.176-182
    • /
    • 1983
  • Malignant lymphoma in chest wall is a rare form of extranodal variety as occasionally localized tumor. The primary site is suggested from rib or soft tissue, but the incidence in rib is higher than soft tissue. The patient, a male, aged 32, noted a swelling and pain over the left lower posterior chest from 3 months prior to admission. Roentgenograms revealed bony destruction in left 9, & 19th ribs posteriorly and associated chest wall mass which was ill defined uncleared margination. Under diagnosis of malignant tumor, the operation was performed and the tumor mass resected widely with en bloc technique than the fascia lata was grafted at chest wall defect. The histology of specimen was disclosed as malignant lymphoma, non-Hodgkin`s diffuse lymphocytic poorly differentiated form. The radio-and chemotherapy were combined post-operatively and the complete remission is acquired.

  • PDF

Acceleration data and shape change characteristics of a gravity quay wall according to inclination condition grades

  • Su-Kyeong Geum;Jong-Han Lee;Dohyoung Shin;Jiyoung Min
    • Structural Engineering and Mechanics
    • /
    • v.90 no.6
    • /
    • pp.591-600
    • /
    • 2024
  • This study investigated the acceleration response and shape change characteristics of a gravity quay wall according to the magnitude of the applied acceleration. The quay wall was defined as a port facility damaged by the Kobe earthquake. Four experimental scenarios were established based on the inclination condition grades, considered to be a significant defect factor in the quay wall. Then, the shaking table test was conducted using scaled-down quay wall models constructed per each scenario. The ground acceleration was gradually increased from the peak ground acceleration (PGA) of 0.1 g to 0.7 g. After each ground acceleration test, acceleration installed on the wall and backfill ground and inclination on the top of the wall were measured to assess the amplification of peak response acceleration and maximum response amplitude and the change in the inclination of the quay wall. This study also analyzed the separation of the quay wall from the backfill and the crack pattern of the backfill ground according to PGA values and inclination condition grades. The result of this study shows that response acceleration could provide a reasonable prediction for the changes in the inclination of the quay wall and the crack generation and propagation on the backfill from a current inclination condition grade.

Primary Tumors of the Chest Wall (원발성 흉벽종양)

  • 마중성;최병우;유회성
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.61-66
    • /
    • 1974
  • Primary tumors of the chest wall are rare than those of other portions of the body. Soft tissue tumors of the chest wall, though these are benign or malignant, should not be paid special attentions about their management than other soft tissue tumors of the body. Thoracic skeletal tumors, however, have some problems in the treatment because of defect in chest wall leading to herniation of lung and paradoxical movement of thoracic cage. The authors experienced 10 case of primary chest wall tumors at the department of thoracic and cardiovascular surgery, the national medical center, during last 15 years. Five of 10 cases were soft tissue tumors, and they were 2 case of lipoma and each one case of myxosarcoma and leiomyosarcoma. Among 5 bone tumors there no cases of sternal tumor, and their histopathological diagnosis were each one of fibrous dysplasia, giant cell tumor, osteochondroma, Ewing`s sarcoma and osteogenic sarcoma. Wide excision, though it was palliative one in certain case, was performed in 9 cases and only diagnostic incisional biopsy in one case, There were no postoperative deaths during admission to the hospital and all cases were missed during short term follow up after discharge from the hospital.

  • PDF

Acellular dermal matrix and bone cement sandwich technique for chest wall reconstruction

  • Heo, Chan Yeong;Kang, Byungkwon;Jeong, Jae Hoon;Kim, Kwhanmien;Myung, Yujin
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.25-28
    • /
    • 2022
  • The authors performed rigid reconstruction using the sandwich technique for full-thickness chest wall defects by using two layers of acellular dermal matrix and bone cement. We assessed six patients who underwent chest wall reconstruction. Reconstruction was performed by sandwiching bone cement between two layers of acellular dermal matrix. In all patients, there was no defect of the overlying soft tissue, and primary closure was performed for external wounds. The average follow-up period was 4 years (range, 2-8 years). No major complications were noted. The sandwich technique can serve as an efficient and safe option for chest wall reconstruction.