• Title/Summary/Keyword: 1 wall defect

Search Result 217, Processing Time 0.027 seconds

THE RECONSTRUCTION OF THE MAXILLARY WALL DEFECT USING MICRO-TITANIUM MESH (Micro-titanium mesh를 이용한 상악골 결손부의 재건술에 관한 연구)

  • Kim, Seong-Gon;Choi, You-Sung;Choung, Pill-Hoon;Lee, Hee-Chul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.197-203
    • /
    • 2000
  • Maxillary defect may be induced by trauma, inflammation, cyst, tumor and surgical procedure. In case of limited wall defect, free bone graft has been preferred. But it has some problems such as postoperative bone resorption and soft tissue inclusion to recipient site. And we can not use free bone in the case who has inflammation in the donor site. So we used the micro-titanium mesh as reconstructive material for the maxillary wall defect. We had operated 8 patients who were diagnosed as maxillary partial defects from June 1997 to September 1998 in the Chin-Hae military hospital. They were 1 case of antral wall defect, 1 case of palatal wall defect, 5 cases of infra-orbital wall defects and 1 case of oroantral fistula case. As a result, the micro-titanium mesh has shown the morphological stability and biocompatibility and it could be used in case who has infection. And mesh structure could prevent soft tissue ingrowth to bony defect area. Thus it can be used to the case of maxillary partial defect successfully.

  • PDF

Geometric Characteristic of Wall-thinning Defect Causing Circumferential Crack in Pipe Elbows (원주방향 균열이 발생되는 곡관 감육부의 형상적 특성)

  • Kim, Jin Weon;Lee, Sung Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • The objective of this study is to classify the geometry of wall-thinning defect that causes a circumferential crack in the pipe elbows subjected to internal pressure. For this objective, first of all a criterion to determine the occurrence of circumferential cracking at wall-thinned area was developed based on finite element simulation for burst tests of pipe elbow specimens that showed axial and circumferential cracking at wall-thinned area. In addition, parametric finite element analysis including various wall-thinning geometries, locations, and pipe geometries was conducted and the wall-thinning geometries that initiate circumferential crack were determined by applying the criterion to the results of parametric analysis. It showed that the circumferential crack occurs at wall-thinning defect, which has a deep, wide, and short geometry. Also, it is indicated that the pipe elbows with larger radius to thickness ratio are more susceptible to circumferential cracking at wall-thinned area.

Traumatic Abdominal Wall Hernia (TAWH): Repair by using a Prolen Mesh (복부손상으로 생긴 탈장에 Prolene Mesh를 이용한 수술 1례)

  • Park, Seung Yeon;Chung, Min
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.119-122
    • /
    • 2009
  • Traumatic abdominal wall hernia after blunt abdominal trauma is rare. The prevalence of traumatic abdominal wall hernia in published series is approximately 1%. Recently, by the use of computed tomography has increased the number of occult traumatic abdominal wall hernias (TAWH). A 47-year-old woman presented to the emergency room soon after a traffic accident. She was fully conscious and complained of diffuse, dull, abdominal pain. She had a seat belt on at the time of the accident. Initial computed tomography showed that the lower left abdominal wall had a defect and that a part of the small bowel had herniated through the defect. During the operation, we made an incision at the defect site and confirmed the defect. The defect size was about $15{\times}5cm$. The muscle layers were repaired in layers with absorbable sutures. Prolen mesh was layed down and fixed on the site of the repaired muscle defect. After 6 months, hernia had not recurred, and no weakness of the repaired abdominal wall layers was identified. The patient's postoperative body functions were normal.

A RADIOGRAPHIC STUDY OF THE EXPERIMENTAL LESIONS IN THE MAXILLARY SINUS (상악동의 실험병소에 관한 X선학적 연구)

  • Lee Joo Hyun;Hwang Eui Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.115-124
    • /
    • 1994
  • The purpose of this study was to examine the differences in representation of a globular radiopaque mass on the pantomograms and Waters' views and to compare the efficacy of periapical radiograms, pantomograms and Waters' views in detection of defects on the internal walls of the maxillary sinus. This study was performed with dried human skull. For the study of difference of radiopaque mass shadow in the two views, rubber ball with a diameter of 10㎜ was used as the experimental lesion. It was placed successively on the internal wall of the anterior, posterior, medial, lateral walls and floor of the maxillary sinus. To examine the detectability of defects for radiographic techniques, defects were formed in the anterior, posterior, medial, lateral walls, and floor of the maxillary sinus. They were formed with 0.5㎜, 0.75㎜, 1.0㎜, 2.0㎜ and 3.0㎜ sized steel round burs with a slow speed dental handpiece. By subsequently plugging the holes with zinc oxide eugenol paste, radiopaque defects were produced. After that the periapical radiograms, the pantomograms and the Waters' views were taken each and every defect. The obtained results were as follows: 1. Rubber balls placed on each internal wall of the maxillary sinus were correctly depicted on the posterior wall and the floor in case of the pantomogram, and on the anterior wall and the medial wall in case of the Waters' view. 2. On the detectability of defects for each radiographic technique, radiolucent defects were detected in different places for each technique. Periapical radiogram could detect 1.0㎜ defect on the floor of the maxillary sinus, pantomogram could detect 2.0㎜ defect on every internal wall of the maxillary sinus, and Waters' view could detect 3.0㎜ defect on the anterior wall of the maxillary sinus. 3. On the detectability of defects for each radiographic technique, radiopaque defects were detected in different places for each technique. Periapical radiogram could clearly detect 0.5㎜ defect on the floor of the maxillary sinus, pantomogram could detect 0.5㎜ defect on every internal wall of the maxillary sinus, and finally Waters' view could detect 0.5㎜defect on the anterior wall of the maxillary sinus but 0.75㎜ defect on the anterior wall, lateral wall and floor of the maxillary sinus. As the result, the periapical radiogram is the most simple and satisfactory method for investigating in the maxillary sinus. The pantomogram is suitable method for screening of changes in the maxillary sinus. And the Waters' view is available for detect of lesion in the anterior wall of the maxillary sinus. For the purpose of accurate diagnosis and evaluation of lesion in the maxillary sinus, these techniques supplement each other.

  • PDF

Defects Length Measurement Using an Estimation Agorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam (레이저 슬릿 빔의 경사각과 카메라 자세 추정 알고리듬을 이용한 벽면결함 길이측정)

  • Kim, Young-Hwang;Yoon, Ji-Sup;Kang, E-Sok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2002
  • A method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation, which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed as an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle as the image normal as the wall and thus, it enables the accurate measurement of the defect lengths by using a single camera and a laser slit beam.

Random topological defects in double-walled carbon nanotubes: On characterization and programmable defect-engineering of spatio-mechanical properties

  • A. Roy;K. K. Gupta;S. Dey;T. Mukhopadhyay
    • Advances in nano research
    • /
    • v.16 no.1
    • /
    • pp.91-109
    • /
    • 2024
  • Carbon nanotubes are drawing wide attention of research communities and several industries due to their versatile capabilities covering mechanical and other multi-physical properties. However, owing to extreme operating conditions of the synthesis process of these nanostructures, they are often imposed with certain inevitable structural deformities such as single vacancy and nanopore defects. These random irregularities limit the intended functionalities of carbon nanotubes severely. In this article, we investigate the mechanical behaviour of double-wall carbon nanotubes (DWCNT) under the influence of arbitrarily distributed single vacancy and nanopore defects in the outer wall, inner wall, and both the walls. Large-scale molecular simulations reveal that the nanopore defects have more detrimental effects on the mechanical behaviour of DWCNTs, while the defects in the inner wall of DWCNTs make the nanostructures more vulnerable to withstand high longitudinal deformation. From a different perspective, to exploit the mechanics of damage for achieving defect-induced shape modulation and region-wise deformation control, we have further explored the localized longitudinal and transverse spatial effects of DWCNT by designing the defects for their regional distribution. The comprehensive numerical results of the present study would lead to the characterization of the critical mechanical properties of DWCNTs under the presence of inevitable intrinsic defects along with the aspect of defect-induced spatial modulation of shapes for prospective applications in a range of nanoelectromechanical systems and devices.

Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique (적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출)

  • Yun, Kyung-Won;Kim, Dong-Lyul;Jung, Hyun-Chul;Hong, Dong-Pyo;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • In the advanced research deducted infrared thermography (IRT) test using 4 inch pipe with artificial wall-thinning defect to measure on the wall-thinned nuclear pipe components. This study conducted for defect detection condition of nuclear small-bore pipe research using deducted condition in the advanced research. Defect process is processed by change for defect length, circumferential direction angle, wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and Target pipe experiment performed to the distance of the changed 1 m, 1.5 m, 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. artificial defect of 4 inch pipe is high reliability in the 2 m, but small-bore pipe is in the 1.5 m from the defect clearly was detected.

Effect of Circumferential Location of Local Well Thinning Defect on the Collapse Moment of Elbow (엘보우 붕괴모멘트에 미치는 국부 감육결함의 원주방향 위치에 대한 영향)

  • Kim Jin-Weon;Lee Jang-Gon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.55-61
    • /
    • 2005
  • The purpose of this study is to investigate the effect of circumferential location of local wall thinning defect on the collapse behavior of an elbow. Thus, the present study conducts three-dimensional finite element analysis on the 90-degree elbow containing a local wall thinning at intrados, crown and extrados of bend region and evaluates the collapse moment of wall thinned elbow under various thinning shapes and loading conditions. Combined internal pressure and bending moment are considered as an applied load. The internal pressure of $0\~20MPa$ and both closing and opening mode bending are employed. The results of analysis show that the reduction in collapse moment of the elbow by local wall thinning is more significant for a defect locating at crown than for a defect locating at intrados or at extrados. Also, the effect of internal pressure on the collapse moment of wall thinned elbow depends on the circumferential location of thinning defect and applied bending mode.

Reconstruction of a large chest wall defect using bilateral pectoralis major myocutaneous flaps and V-Y rotation advancement flaps: a case report

  • Jo, Gang Yeon;Yoon, Jin Myung;Ki, Sae Hwi
    • Archives of Plastic Surgery
    • /
    • v.49 no.1
    • /
    • pp.39-42
    • /
    • 2022
  • Bilateral pectoralis major myocutaneous (PMMC) flaps are commonly used to reconstruct large chest wall defects. We report a case of large chest wall defect reconstruction using bilateral PMMC flaps augmented with axillary V-Y advancement rotation flaps for additional flap advancement. A 74-year-old male patient was operated on for recurrent glottic squamous cell carcinoma. Excision of the tumor resulted in a 10×10 cm defect in the anterior chest wall. Bilateral PMMC flaps were raised to cover the chest wall defect. For further flap advancement, V-Y rotation advancement flaps from both axillae were added to allow complete closure. All flaps survived completely, and postoperative shoulder abduction was not limited (100° on the right side and 92° on the left). Age-related skin redundancy in the axillae enabled the use of V-Y rotation advancement flaps without limitation of shoulder motion. Bilateral PMMC advancement flaps and the additional use of V-Y rotation advancement flaps from both axillae may be a useful reconstructive option for very large chest wall defects in older patients.

Defect Length Measurement using Underwater Camera and A Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.746-751
    • /
    • 2003
  • A method of measuring the length of defects on the wall of the spent nuclear fuel pool using the image processing and a laser slit beam is proposed. Since the defect monitoring camera is suspended by a crane and hinged to the crane hook, the camera viewing direction can not be adjusted to the orientation that is exactly perpendicular to the wall. Thus, the image taken by the camera, which is horizontally rotated along the axis of the camera supporting beam, is distorted and thus, the precise length can not be measured. In this paper, by using the LASER slit beam generator, the horizontally rotated angle of the camera is estimated. Once the angle is obtained, the distorted image can be easily reconstructed to the image normal to the wall. The estimation algorithm adopts a 3-dimensional coordinate transformation of the image plane where both the laser slit beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect taken at arbitrary rotated angle can be reconstructed to an image normal to the wall. From the result of a series of experiments, the accuracy of the defect is measured within 0.6 and 1.3 % error bound of real defect size in the air and underwater, respectively under 30 degree of the inclined angle of the laser slit beam generator. Also, the error increases as the inclined angle increases upto 60 degree. Over this angle, the defect length can not be measured since the defect image disappears. The proposed algorithm enables the accurate measurement of the defect length only by using a single camera and a laser slit beam.

  • PDF