• 제목/요약/키워드: 1 day strength

검색결과 639건 처리시간 0.026초

광중합 GIC충전후 경과시간 및 표면처리에 따른 복합레진과의 결합강도에 관한 연구 (THE SHEAR BOND STRENGTHS OF COMPOSITE RESINS TO GLASS IONOMER CEMENTS BY SURFACE TREATMENT AND ELAPSED TIME)

  • 정혜인;김신;정태성
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.82-94
    • /
    • 1997
  • For the purpose of establishing the most appropriate method of bonding between glass ionomer liners and composite resin and comparing the materials for sandwich technique, an experiment was performed to measure the shear bond strengths between the two with the variables in the surface treatment of liners and elapsed time till composite buildup. Materials used were Vitrebond and Fuji II LC, each as the restorative and liner respectively, and each group was subdivided by surface treatment (acid etching and sandblasting) and time elapsed from GIC filling to composite buildup (immediately, 1 day, 7 days), consisting 12 groups as a whole. Each subgroup was composed of 10 specimens and the shear bond strength between GIC liners and composite resin was measured under UTM and analyzed. The result were as follows: 1. The shear bond strength between two materials was highest when initially filled Fuji II LC was sandblasted after 1 days and composite built-up (Group FS1). And the lowest value was found when GIC was acid-etched after 7 days and composite built-up (Group FE7). Significant difference was found between the two groups. (P<0.01) 2. In regard of surface treatment of GI liners, acid-etched group (VE) showed higher bond strength than sandblasted group (VS) for Vitrebond. But, the reverse was true for Fuji II LC. (P<0.05) 3. In regard to the time elapsed from GI filling to composite buildup, the group of 1 day elapse showed relatively higher strength for Vitrebond. On the contrary, immediate buildup group (FE0) was stronger for acid-etched group and 1 day elapse group(FS1) was higher for sand-blasted group in Fuji II LC. (P<0.05)

  • PDF

Application of internet of things for structural assessment of concrete structures: Approach via experimental study

  • D. Jegatheeswaran;P. Ashokkumar
    • Smart Structures and Systems
    • /
    • 제31권1호
    • /
    • pp.1-11
    • /
    • 2023
  • Assessment of the compressive strength of concrete plays a major role during formwork removal and in the prestressing process. In concrete, temperature changes occur due to hydration which is an influencing factor that decides the compressive strength of concrete. Many methods are available to find the compressive strength of concrete, but the maturity method has the advantage of prognosticating strength without destruction. The temperature-time factor is found using a LM35 temperature sensor through the IoT technique. An experimental investigation was carried out with 56 concrete cubes, where 35 cubes were for obtaining the compressive strength of concrete using a universal testing machine while 21 concrete cubes monitored concrete's temperature by embedding a temperature sensor in each grade of M25, M30, M35, and M40 concrete. The mathematical prediction model equation was developed based on the temperature-time factor during the early age compressive strength on the 1st, 2nd, 3rd and 7th days in the M25, M30, M35, and M40 grades of concrete with their temperature. The 14th, 21st and 28th day's compressive strength was predicted with the mathematical predicted equation and compared with conventional results which fall within a 2% difference. The compressive strength of concrete at any desired age (day) before reaching 28 days results in the discovery of the prediction coefficient. Comparative analysis of the results found by the predicted mathematical model show that, it was very close to the results of the conventional method.

단위수량 변화에 따른 혼화제 종류 및 첨가량별 콘크리트의 특성 분석 (An Analysis of Concrete Characteristics by Admixing Agent and Additive Contents According to the Change of Unit-Water)

  • 류현기;우종권;조명근
    • 한국건축시공학회지
    • /
    • 제7권4호
    • /
    • pp.139-144
    • /
    • 2007
  • The purpose of this study is to analyze concrete characteristics by admixing agent and additive contents according to the change of unit-water to identify its effect on compressive strength. First of all, as for flesh concrete, overall unit-water showed a tendency to decrease as component inclusion rate of admixing agent was increased. In addition, air content showed a tendency to increase by increasing WR, WB, NP series admixing agent contents, on the other hand, the change of air content was gentle by around $1.5{\pm}0.5%$ for S, T, M series agents. Bulk density showed an inverse proportion to the change of air content. As for hardened concrete, expression rate of 3-day age compressive strength was generally decreased for S, T, WR, WB, NP, M series admixing agent component. Also, expression rate of 7-day age compressive strength showed an excellent record for S, M series agents, and expression rate of 28-day age compressive strength showed a tendency to increase more than plain on the whole.

Optimization of mix design of micro-concrete for shaking table test

  • Zhou, Ji;Gao, Xin;Liu, Chaofeng
    • Advances in concrete construction
    • /
    • 제13권3호
    • /
    • pp.215-221
    • /
    • 2022
  • Considering their similar mass densities, an attempt was made to optimize the mix design of micro-concrete that used barite sand as an aggregate by substituting marble powder (5%, 10%, 20%, 30%, 40%, 50%, 70%), clay brick powder (30%, 50%, 70%), and fly ash (30%, 50%, 70%) for the concrete (by mass) to form specimens for shaking table tests. The test results showed that for these three groups of materials, the substitutions had little effect on the density. The barite sand played a decisive role in the density, and the overall density of the specimens reached approximately 2.9 g/cm3. The compressive strength and elastic modulus decreased with an increase in the substitution rates for the three types of materials. Among them, the 28 day compressive strength values of the 40% and 50% marble powder groups were 11.73 MPa and 8.33 MPa, respectively, which were 58.7% and 70.7% lower than the control group, respectively. Their elastic modulus values were 1.33×104 MPa and 1.42×104 MPa, respectively, which were 39.1% and 35% lower than those of the control group, respectively. The 28 day compressive strength values of the 50% and 70% clay brick powder groups were 13.13 MPa and 5.8 MPa, respectively, which were 53.8% and 79.6% lower than the control group, respectively. Their elastic modulus values were 1.54×104 MPa and 1.19×104 MPa, respectively, which were 29.7% and 45.4% lower than those of the control group, respectively. The 28 day compressive strength values of the 50% and 70% fly ash groups were 13.5 MPa and 7.1 MPa, respectively, which were 52.5% and 75% lower than those of the control group, respectively. Their elastic modulus values were 1.36×104 MPa and 0.95×104 MPa, respectively, which were 37.9% and 56.6% lower than those of the control group, respectively. There was a linear relationship between the 28 day compressive strength and elastic modulus, with the correlation coefficient reaching a value higher than 0.88. The test results showed that the model materials met the high density, low compressive strength, and low elastic modulus requirements for shaking table tests, and the test data of the three groups of different alternative materials were compared and analyzed to provide references and assistance for relevant model testers.

침관입시험을 이용한 연약암반의 일축압축강도 추정 (Estimation of Uniaxial Compressive Strength of Weak Rocks Using Needle Penetrometer)

  • 강성승;오바라 유조;제동광;박영호
    • 터널과지하공간
    • /
    • 제21권1호
    • /
    • pp.41-49
    • /
    • 2011
  • 본 연구는 침관입시험을 이용하여 연약암반에 대한 일축압축강도를 추정하기 위한 연구결과를 나타낸 것이다. 침관입시험을 위한 인공암반의 배합비는 시멘트(C):벤토나이트(B):물(W) = 1.3:0.7:2.3 또는 1.5:0.5:2.0이 적절한 것으로 나타났다. 침관입시험에 의해 측정된 침관입저항력(NPR)과 이로부터 추정된 일축압축강도(UCS) 관계에서 NPR과 UCS는 양생기간이 길어짐에 따라 증가하는 경향을 보였다. 또한 침관입시험에 의해 측정된 NPR과 실제 시험에서 얻어진 UCS 관계에서는 NPR-UCS가 배합비와 상관없이 양생기간이 3일~14일까지는 선형적으로 증가하다가 14일~28일에서는 NPR-UCS가 작은 차이를 보이지만 거의 일정한 관계로 나타났다. 결론적으로 전체적인 NPR-UCS의 관계는 대체적으로 선형적인 관계를 보이며, 이것은 연약암반의 경우 침관입 시험에 의한 NPR로부터 일축압축강도를 추정하는 것이 가능함을 의미한다.

조강시멘트를 이용한 속경성 자기충전 콘크리트의 배합인자별 품질특성 및 활용에 관한 연구 (Study on the qualities & application of Super High Early Strength -Self Compact Concrete using Type III Cement for productabilities-)

  • 엄태선;임채용;유재상;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.573-578
    • /
    • 2002
  • We carried out the feasibility study of super early self compacting concrete having the characteristics of 1 day demoulding without steam curing, high flowable concrete with self compacting, high strength and high durability etc. Here, We test and selected by several methods using high early cement with and without admixtures for the condition of super early strength self compacting concrete's manufacture (SSCC). We sucessed to meet at the goal of SSCC with 30∼35N/㎟ in 1 day, without steam curing and with slump flow about 60-65cm and suggest various concrete products to apply the developed SSCC for practical use in factory and in site place

  • PDF

속경성 자기충전 콘크리트의 기초특성 연구( I ) (A Study on Basic Properties of Super Early Strength Self Compacting Concretes( I ))

  • 엄태선;임채용;유재상;이종열;이근호;한재명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.79-84
    • /
    • 2002
  • We carried out the feasibility study of super early self compacting concrete having the characteristics of 1 day demoulding without steam curing, high flowable concrete with self compacting, high strength and high durability etc. Here, We test and selected by several methods using high early cement with and without admixtures for the condition of super early strength self compacting concrete's manufacture (SSCC). we sucessed to meet at the goal of SSCC with 20-35N/mm$^2$ at 1 day, without steam curing and with slump flow about 60-65cm. We continue to search the effectual conditions of SSCC's manufacture by changing mix designs, several of admixture (superplasticizer, stabilising agent), slag, fly ash, high early cement and apply the products for practical use.

  • PDF

Soil stabilization of clay with lignin, rice husk powder and ash

  • Canakci, Hanifi;Aziz, Aram;Celik, Fatih
    • Geomechanics and Engineering
    • /
    • 제8권1호
    • /
    • pp.67-79
    • /
    • 2015
  • This article presents the result of laboratory study conducted on expansive soil specimens treated with lignin, rice husk powder (RHP) and rice husk ash (RHA). The amount of lignin produced from paper industry and RHP were varied from 0 to 20% and RHA from 0 to 10% by weight. The treated specimens were subjected to unconfined compressive strength (UCS),swelling test and Atterberg limit tests. The effect of additives on UCS and atterberg limit test results were reported. It was observed that the additives and curing duration had a significant effect on the strength value of treated specimens. Generally (except the sample treated with 20% RHP for 3-day) with increasing additive and curing duration the UCS value increases. A RHP content of 15% was found to be the optimum with regard to 3-day cure UCS.

Synthesis and Characterization of Zinc Phosphate Cement Powder and Cement-forming Liquid

  • Park, Choon-Keun
    • The Korean Journal of Ceramics
    • /
    • 제3권4호
    • /
    • pp.269-273
    • /
    • 1997
  • Chemical composition of cement powder influences the setting time and early compressive strength development. The setting time increases as the amounts of zinc oxide and magnesium oxide are increased. For one day compressive strength development, a cement powder with a composition 90% ZnO, 8% MgO and 2% silica resulted in the highest strength (greater than 1, 090 kg/$\textrm{cm}^2$). Cement-forming liquids also need to be buffered, with both aluminum and zinc ions, for a good consistency and a higher strength of the zinc phosphate cement. These liquids control the setting reactions.

  • PDF

공기부상 생물막 반응기를 이용한 산업폐수 처리 (Wastewater Treatment using Air-lift Biofilm Reactor)

  • 최광수;한기백
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.351-367
    • /
    • 2000
  • Air-lift biofilm reactor should be an admirable process substituting conventional activated sludge process, because of its small area requirement as well as high volumetric loading capacity and stability against loading and chemical shocks. However most of the past research on the performance of ABR was focused on the sewage treatment. This research studied the applicability of ABR to treat high strength wastewater. A bench-scale ABR was operated to treat high strength synthetic wastewater, tannery wastewater and petrochemical wastewater, and its applicability was conclusive In case of synthetic wastewater, ABR showed good performance in which the substarate removal efficiency was higher that 80% even under short HRT(1.4 hr) and high volumetric loading rate(9.3 kgCODcr/$m^3$.day). When ABR was applied to treat tannery wastewater, it was suggested that the maximum volumetric loading rate and F/M ratio should be 7.7kgCODcr/$m^3$.day, 0.76 $day^{-1}$, respectively. And high substrate removal efficiency over than 90 % was observed with 4,000 mgCODcr/L of petrochemical wastewater. Even though effluent concentration was quite high, ABR should be applicable to treat the high strength wastewater, because of its high loading capacity.

  • PDF