• Title/Summary/Keyword: 1/3 octave band

Search Result 66, Processing Time 0.024 seconds

Real Time 1/3 Octave Band Control System for High Intensity Acoustic Chamber (음향 챔버 내부의 1/3 옥타브 스펙트럼 실시간 제어 시스템)

  • Kim, Young-Key;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.881-885
    • /
    • 2002
  • This paper presents the performance and the algorithm of a 1/3-octave band spectrum control system. The system is developed to provide various spectrums in a high intensity acoustic chamber. The required spectrum, which usually comes from launch vehicle company, starts from 25Hz band and ends 10kHz band. Automatic spectrum control system is preferred since the system requires short settling time to guarantee the safety of test objects and to reduce the amount of operating gas. The developed system adapted a PCI data-acquisition/signal-generation board installed in a personal computer to implement whole control logic. The control software used three cascade digital Butterworth filters using software. The filers are designed following ANSI S1.11 standard to implement 1/3 octave band filter bank. The graphical user interface of the system guides the user to follow standard operation procedure. The averaged control spectrum showed less than 0.05 dB in every running 1/3-octave band.

  • PDF

Real-Time 1/3-Octave Band Spectrum Control System of High Intensity Acoustic Chamber (음향 첨버 내부의 1/3-옥타브밴드 스펙트럼 실시간 제어 시스템)

  • Kim, Youngkey K.;Kim, Hong-Bae;Moon, Sang-Mu;Woo, Sung-Hyun;Lee, Sang-Seol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.2-386
    • /
    • 2002
  • This paper reports the performance and the Algorithm of an 1/3-octave band spectrum control system. The system is developed to provide various required spectrums in a high intensity acoustic chamber. The required spectrums, which usually comes from launch vehicle specification, starts from 25㎐ band and ends 10,000㎐. Short settling time is required to guarantee the safety of test objects and reduce the amount of operating gas. (omitted)

  • PDF

Field Test and Evaluation of Noise from Wind Turbine Generators at Yongdang and Hangwon in Jeju Island (제주도 용당/행원 풍력발전기 현장 소음 실증)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Shin, Su-Hyun;Jeon, Se-Jong;Lee, Saeng-Hui
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.818-821
    • /
    • 2005
  • The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang and 660 kW WTG at Hangwon in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure levels (ECSPL) of 660 kW WTG at Hangwon vary more widely with wind speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Field Test and Evaluation of Wind Turbine Noise according to IEC Standards (IEC 규격에 따른 풍력 터빈 소음의 현장 실증)

  • Cheong, Cheol-Ung;Jung, Sung-Su;Cheung, Wan-Sup;Shin, Soo-Hyun;Chun, Se-Jong;Lee, Sang-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.579-582
    • /
    • 2005
  • The sound measurement techniques in IEC 61400-11 are applied to field test and evaluation of noise emission from 1.5 MW wind turbine generator (WTG) at Yongdang-Lee and 650 kW WTG at Hangwon-Lee in Jeju Island. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. 1.5 MW WTG at Yongdang is found to emit lower sound power than 660 kW one at Hangwon, which seems to be due to lower rotating speed of the rotor of WTG at Yongdang. Equivalent continuous sound pressure level s (ECSPL) of 650 kW WTG at Hangwon vary more widely with speed than those of 1.5 MW WTG at Yongdang. The reason for this is believed to be the fixed blade-rotating speed of WTG at Yongdang. One-third octave band analysis of the measured data show that the band components around 400-500 Hz are dominant for 1.5 MW WTG at Yongdang and those around 1K Hz are dominant for 660 kW WTG at Hangwon.

  • PDF

Wind Turbine Noise (풍력발전기 소음평가)

  • Jung, Sung Soo;Jeon, Byung Soo;Seo, Jae Gap;Lee, Yong Bong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.431-434
    • /
    • 2014
  • Wind turbine industry is the most developing field among other renewable energy industry. As expanding wind farms, noise is the big problem to solve. This study is about wind turbine noise measuring method based on IEC 61400-11. Sound pressure levels, 1/3-octave band levels, and low frequency sound pressure levels of a 3 MW wind turbine were measured and analyzed.

  • PDF

Automobile diagnosis by euro-Fuzzy Technique (뉴로-퍼지 기법에 의한 자동차 진단)

  • Shin, Joon;Oh, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1833-1840
    • /
    • 1992
  • In the diagnostic process for automobile, Neuro-Fuzzy technique was compared with the conventional diagnostic method for the verification of performance, and proto-type system was developed. For the utilities of the system, 1/3 octave filter(band-pass filter) and A/D converter were used for data acquisition and then data were analyzed using octave band processing and pattern recognition using hamming network algorithm. In order to raise the reliability of the diagnostic results by considering many operating variables and condition of automobile to be diagnosed, fuzzy inference technique was applied in combining several information. The validation of this diagnostic system was examined through computer simulation and experiment, and it showed an acceptable performance for diagnostic process.

Analysis of free field for Acoustic Anechoic Chamber based on Time Stretched Pulse (Time Stretched Pulse를 이용한 무향실 자유음장 분석)

  • Kim, Keon-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.4
    • /
    • pp.111-119
    • /
    • 2012
  • Time Stretched Pulse (TSP) is used for transmitting and analyzing the impulse signal over the designated spatial place. However, if transfer functions of transmitter and receiver are unknown, performance investigation of free field in temporal domain is barely possible due to the overlap between the direct and indirect signal from the space. Generally, the free field or hemi-free field is evaluated by the Annex A of ISO 3745 in which utilizing the inverse square law with one-third octave band signals. In this paper, the author performs analysis of free field via applying TSP with inverse square law and the results are compared with the one-third octave band signals. According to the analysis of deviation between the corresponding signal and inverse square law model, the proposed TSP method provides the comparable performance index to the one-third octave band signal with reduced measuring time. Provided that the pre-whitening can be implementable by employing the speaker and microphone transfer function, further analyses from TSP compression are able to be performed such as multipath separation from time domain data. The anechoic chamber used in this experiment is verified conformance with ISO 3745 for free field and hemi-free field condition for limited frequency of the signal.

Radar Probing of Concrete Specimens Using Frequency Domain Filtering (주파수 영역 필터링을 통한 콘크리트 시편 내부 레이더 탐사)

  • 임홍철;이윤식
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.23-29
    • /
    • 2002
  • Radar method can be effective in probing concrete structures damaged by earthquake. Data analysis is usually performed in time domain, by considering time delay of the wave due to the dielectric constant of concrete. In this study, improved data analysis has been performed using signal processing scheme of spectra analysis and filtering. Three antenna with 900MHz, 1㎓, and 1.5㎓ center frequency were used to detect a steel bar or delamination in specimens for obtaining data, Frequency spectrum was filtered in low pass, high pass, and band pass varying cutoff frequency with 1/3 octave in frequency domain. The most effective cutoff frequency for each frequency has been determined as the range for 2 octave lower to 1 octave higher and 2 octave lower to 1 octave lower. This result provided a basis in improving data analysis capability using frequency domain filtering.

Effects of sound absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound (흡음 석고보드 천장재에 의한 저주파 중량 바닥충격음의 저감 효과)

  • Song, Han-Sol;Ryu, Jong-Kwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.323-330
    • /
    • 2018
  • This study investigated effects of absorbent gypsum board in the ceiling on low-frequency heavyweight floor impact sound through sound absorption coefficient and floor impact sound measurement. The sound absorption coefficients were measured with sound absorbent gypsum board, glass wool on gypsum board, and a double panel absorbent gypsum board (absorbent gypsum board + glass wool + absorbent gypsum board). Result showed that the absorbent gypsum board had sound absorption coefficient of 0.1 ~ 0.7 from 200 and 630 Hz octave band. The sound absorption coefficient was increased in all frequency range by adding glass wool. Additional absorbent gypsum board increased sound absorption coefficient up to 250 Hz octave band, but decreased over 250 Hz. Heavyweight floor impact sounds were measured in test building for three materials above, gypsum board, and bare slab. Result showed that glass wool on gypsum board and a double panel absorbent gypsum board reduced by 3 dB ~ 4 dB (single number quantity) heavyweight floor impact sound. Comparing with bare slab condition, floor impact sound reduction was mainly found from 125 Hz to 500 Hz octave band, and the maximum reduction was shown in the 250 Hz octave band.

The Study of Improvement of the Void Slab Applying the Impedance Method (임피던스법을 이용한 보이드 슬라브의 개선방안에 관한 연구)

  • 오재응;김영식
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.276-284
    • /
    • 2001
  • In apartment buildings, floor-impact sound has been regarded as the major source that causes complaints from residents. It is mainly due to the use of light-weight structures and the lack of researches in terms of floor-impact sound. The purposes of this study are analyzing the characteristics of vibration response and sound radiation of 12type void slabs in the improvements void slab by impedance method and finding the fittest improvements void slab on the 12type void slab. The main results of this study are summarized as below: (1) In the $\frac{1}{3}$ octave band level of sound radiation, $\frac{1}{3}$ octave band levels, measured from four-divided improvement void slab(No.8) and eight-divided improvement void slab(No.12), are 10~25 dB lower than that of standard void slab(No.1) in the 1250 Hz. Especially, eight-divided improvement void slab(No.12) is the best void slab in terms of radiation efficiency of sound level. (2) In the correlation relation of acceleration and sound radiation, standard void slab(No.1), four-divided improvement void slab(No.8), SK standard four-hole void slab(No.10), and eight-divided improvement void slab(No.12) are positive correlation relation.

  • PDF