• Title/Summary/Keyword: 1/3 Octave Band

Search Result 66, Processing Time 0.028 seconds

Design and Performance Test of Silencers with Ring-shaped Resonators (환형 공명기가 설치된 소음기 설계 및 성능 시험)

  • Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun;Lee, Jong-Hwa;Lee, Hae-Seong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.357-364
    • /
    • 2011
  • In this study, ring-shaped acoustic resonators were proposed to be installed in a silencer to increase the acoustic performance of silencer in the low-frequency range. Evaluation of noise reduction performance of acoustic resonator arrays was carried out by measuring the random-incidence absorption coefficient. It was found that the absorption coefficient of resonator array was measured up to 1 at 125 Hz of 1/3-octave band center frequency. Insertion losses of silencers with ring-shaped acoustic resonator arrays were measured based on ISO 7235. The results were shown that the ring-shaped resonator could increase the insertion loss up to 13 dB without flow, whereas 7 dB when flow speed reached 15 m/s. As increasing the flow speed above 15 m/s, the effect of acoustic resonator decreased due to the effect of nonlinear air damping of the resonator. It was also found that the increment of pressure drop by the presence of resonator arrays was about 9 % at flow speed of 25 m/s.

Interior Noise and Low Frequency Noise Characteristics of Busan Metro Line 3 Noise (부산도시철도 3호선 실내소음 및 저주파 소음 특성)

  • Hong, Do-Kwan;Jeong, Jae-Boo;Jung, Seung-Wook;Gang, Hyun-Wook;Ahn, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1113-1120
    • /
    • 2012
  • This paper deals with the analysis of interior noise and low frequency noise characteristic for the Busan citizens to use public transport, Busan Metro Line 3. The interior noise evaluation index, articulation index(AI) is evaluated the lower value about average 22 % in a whole range, this is difficult to have a conversation. Also, noise criteria(NC) curve is partially evaluated as NC-65 below 2000 Hz, space type is evaluated as factories. Another of interior noise evaluation index, preferred speech interference level(PSIL) is evaluated the upper value about average 66 dB(A) in a whole range, this is evaluated to be interrupted. In the case of low frequency noise(20~200 Hz), the measurement of low frequency noise is assessed largely beyond noise criteria of ISO 226. The low frequency noise should be reduced because low frequency noise affects on psychological stress and displeasure although low frequency noise is not recognized by auditory sense. The low frequency noise criteria and guideline will be enacted from now on in Korea.

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

A Survey on the Status of Noisy Working Environment in Manufacturing Industries (제조업 산업장의 소음 작업환경 실태에 관한 조사 연구)

  • Kim, Joon-Youn;Kim, Byung-Soo;Lee, Chae-Un;Jun, Jin-Ho;Lee, Jong-Tae;Kim, Jin-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.1 s.19
    • /
    • pp.16-30
    • /
    • 1986
  • In order to prepare the fundamental data for the improvement of noisy working environments and the effective hearing conservation program on workers exposed to industrial noise, the authors surveyed the working processes and evaluated the noise levels on 56 manufacturing industries in Pusan area from April to July in 1985. The results were summarized as follows : 1. The noise level was the highest in shipbuilding and repairing(95.6 dBA), and followed by steel rolling(94.0 dBA), manufacture of motor vehicles(93.1 dBA), manufacture of fishing nets(92.9 dBA), manufacture of testiles(92.5 dBA), iron and steel foundries(89.3 dBA), manufacture of metal products(89.1 dBA), preserving and processing of marine foods(87.0 dBA), manufacture of rubber products(85.3 dBA), manufacture of plywood(84.9 dBA) and manufacture of paints(84.5 dBA). 2. Among fifty surveyed working processes, the noise level of twenty-one processes (42%) exceeded the threshold limit value for 8 hours per day. 3. As the allowable exposure times by governmental threshold limit values to industrial noise level(dBA), cocking of shipbuilding and repairing and plating(CGL) of steel rolling were the shortest(30 minutes), and followed by assembling(rivet) of manufacture of motor vehicles(1 hour) weaving of manufacture of textiles and shot, machine, pipe laying of shipbuilding and repairing(2 hours). 4. By the result of octave band analysis on noisy working processes in excess of 90 dBA, the sound level was the highest at 2,000 Hz or 4,000 Hz. 5. It was recognized that the measurement of overall sound pressure level was also effective as octave band analysis in evaluating the industrial noise.

  • PDF

Clustering and classification of residential noise sources in apartment buildings based on machine learning using spectral and temporal characteristics (주파수 및 시간 특성을 활용한 머신러닝 기반 공동주택 주거소음의 군집화 및 분류)

  • Jeong-hun Kim;Song-mi Lee;Su-hong Kim;Eun-sung Song;Jong-kwan Ryu
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.603-616
    • /
    • 2023
  • In this study, machine learning-based clustering and classification of residential noise in apartment buildings was conducted using frequency and temporal characteristics. First, a residential noise source dataset was constructed . The residential noise source dataset was consisted of floor impact, airborne, plumbing and equipment noise, environmental, and construction noise. The clustering of residential noise was performed by K-Means clustering method. For frequency characteristics, Leq and Lmax values were derived for 1/1 and 1/3 octave band for each sound source. For temporal characteristics, Leq values were derived at every 6 ms through sound pressure level analysis for 5 s. The number of k in K-Means clustering method was determined through the silhouette coefficient and elbow method. The clustering of residential noise source by frequency characteristic resulted in three clusters for both Leq and Lmax analysis. Temporal characteristic clustered residential noise source into 9 clusters for Leq and 11 clusters for Lmax. Clustering by frequency characteristic clustered according to the proportion of low frequency band. Then, to utilize the clustering results, the residential noise source was classified using three kinds of machine learning. The results of the residential noise classification showed the highest accuracy and f1-score for data labeled with Leq values in 1/3 octave bands, and the highest accuracy and f1-score for classifying residential noise sources with an Artificial Neural Network (ANN) model using both frequency and temporal features, with 93 % accuracy and 92 % f1-score.

A Study on Underwater Acoustic Characteristics by Vegetation in River (하천 식생에 따른 수중음향 분석)

  • Gu, Jung-Eun;Jung, Sang Hwa;Kang, Joongu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.522-522
    • /
    • 2017
  • 하천에서 식생은 하도내 흐름저항과 항력을 증가시켜 유속과 유사이동을 감소시킨다. 유속의 감소로 인해 유사가 퇴적되어 사주 발생이 증가하며 이는 하도 지형변화의 중요한 요인이 된다. 하천내 식생은 하천생물의 서식과 밀접한 관련이 있는 물리적인 서식환경을 변화시키게 된다. 이러한 물리적인 서식환경 변화는 수중음향으로 표현되는 하천의 음환경(Soundscape) 변화로 연결된다. 본 연구는 하천 식생대에서의 수중 음향변화를 식생유무, 수온, 수심에 따라 분석하고 수리학적 특성과의 상관관계를 파악하고자 한다. 실규모 하천 수로에 식생 38 주/$m^2$를 식재하고 1 m정도 성장시킨 후 식생을 완전 침수시켜 $3.2m^3/s$의 유량을 공급하여 유속의 변화와 수중음향을 측정하였다. 오후시간대와 새벽시간대를 이용하여 수온이 다른 조건에서 측정하였고, 수심은 표면 3 cm, 40 cm, 80 cm 깊이에서 각각 측정하였다. 측정지점은 식생구간의 상류지점(A), 식생구간(B), 식생구간의 하류지점(C) 세 곳을 선정하였고, 유속은 micro-ADV, 수중 음향은 Hydrophone을 사용하여 5분간 측정하였다. 측정 주파수 spectrum은 1/3 Octave band로 처리하여 음압을 비교분석하였다. 주파수에 따른 음압을 분석한 결과 측정지점에 관계없이 주로 125 Hz, 315 Hz에서 높게 나타났다. 수심에 따른 음향을 분석한 결과 식생이 없는 상류(A)지점에서는 수중음향의 차이가 크게 나타났으며, 식생지점(B)과 식생이 없는 하류(C)지점에서는 수중음향이 유사하게 나타났다. 이는 식생에 의한 유속의 저하로 인해 흐름이 안정화되어 나타나는 현상으로 판단된다. 수온에 따라서는 식생구간(B)과 하류(C)지점에서 대체로 큰 차이를 보이지 않았으나 상류(A)지점에서는 수온이 높을 때 음압이 더 크게 나타났다. 이는 온도가 높을수록 소리의 전달속도가 더 빨라지기 때문으로 판단된다. 이처럼 식생의 유무와 수심, 온도에 따라 하천의 수리학적 특성이 달라지고 이에 따른 수중음향도 달라지므로 하천의 물리적 서식환경을 평가하기 위한 인자로 수중음향을 활용할 수 있을 것으로 사료된다.

  • PDF

SOUND PRODUCTION AND BEHAVIOUR OF CRABS, PORTUNUS TRITUBERCULATUS(MIERS) (II) (꽃게의 소리와 행동 (II))

  • KIM Sang-Han
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.1
    • /
    • pp.28-36
    • /
    • 1974
  • For the development of acoustic fishing method, we had been researched a fundamental study which concerned on the sound production and behaviour of crabs was conducted. For specimen crabs such as Portunus trituberculatus and Charybdis japonica were selected. Croaking noise were recorded by the Cassette-recorder (Sony model CF-1600) through the under water monitor microphone, and analyzed in frequencies by Octave band analyzer, Rion SA-55, and sound pressure level of source by sound level meter, SM-5844. The following are the results obtained from the present investigations : When sound production of crabs (Portunus trituberculatus( female ) : carapace width $12.6\~15$cm) were attracted to another crabs in the water of anechoic aquarium, efficacy of phonotaxis was $84\~100\%$ and velocity by phonotaxis was $6.5\~7.2cm/sec$. The time required for copulation ranged from 90 minute to 95 minutes by Charybdis japonica, at that time there was no sound production with their copulation.

  • PDF

Study on the Noise Characteristics of Bridge Deck Pavements in Seoul Inner Ring Road (서울시 내부순환도로 교면포장 형식에 따른 소음특성 연구)

  • Lee, Sang-Yum;Jin, Jung-Hoon;Mun, Sung-Ho;Moon, Hak-Ryong
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.19-28
    • /
    • 2012
  • A measuring technique for tire-pavement interaction noise that uses a proposed noble close proximity(NCPX) method, which has been proofed in terms of the reliability and consistency of interaction noise measurement through several researches, equipped with surface microphones has been adopted in order to perform bridge deck pavement noise evaluations on four different pavement surfaces. Through field testing measurement of bridge deck pavement in Seoul inner ring road, the appropriate noise-measuring procedures have been used for evaluating the noise characteristics of four different surfaces. Measuring results show that tire-pavement noise levels vary depending on the surface types and vehicle speeds. Furthermore, the different characteristics of tire-pavement interaction noise can be found before and after the new surface construction of bridge deck pavements in terms of the 1/3 octave band analysis of vehicle speed.

A Study on the Noise Levels of Cargo-Passenger Iron Ships ply South-West Coast Line (서남 연근해 운항 차도철부선의 선내 소음에 관한 연구)

  • Yu Young-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.3 s.26
    • /
    • pp.193-199
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on the ship began to put in a statutory form. After that, in 1982 'International Code on Noise Levels on Board Ships' adopted by IMO and it became a standards to the newly built ship and it remains up to recently. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor. standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

A Study on Development of the Prediction Model Related to the Sound Pressure in Terms of Frequencies, Using the Pass-by and NCPX Method (Pass-by계측과 NCPX계측에 의한 주파수 별 음압 예측 모델 개발에 관한 연구)

  • Kim, Do Wan;Mun, Sungho;An, Deok Soon;Son, Hyeon Jang
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.79-91
    • /
    • 2013
  • PURPOSES : The methods of measuring the sound from the noise source are Pass-by method and NCPX (Noble Close Proximity) method. These measuring methods were used to determine the linkage of TAPL (Total Acoustic Pressure Level) and SPL (Sound Pressure Level) in terms of frequencies. METHODS : The frequency analysis methods are DFT (Discrete Fourier Transform) and FFT (Fast Fourier Transform), CPB (Constant Percentage Bandwidth). The CPB analysis was used in this study, based on the 1/3 octave band option configured for the frequency analysis. Furthermore, the regression analysis was used at the condition related to the sound attenuation effect. The MPE (Mean Percentage Error) and RMSE (Root Mean Squared Error) were utilized for calculating the error. RESULTS : From the results of the CPB frequency analysis, the predicted SPL along the frequency has 99.1% maximum precision with the measured SPL, resulting in roughly 1 dB(A) error. The TAPL results have precision by 99.37% with the measured TAPL. The predicted TAPL results at this study by using the SPL prediction model along the frequency have the maximum precision of 98.37% with the vehicle velocity. CONCLUSIONS : The Predicted SPL model along the frequency and the TAPL result by using the predicted SPL model have a high level of accuracy through this study. But the vehicle velocity-TAPL prediction model from the previous study by using the log regression analysis cannot be consistent with the TAPL result by using the predicted SPL model.