• Title/Summary/Keyword: 1,1,1-TCE

Search Result 225, Processing Time 0.03 seconds

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

A Study on Remediation of Chlorinated Hydrocarbons and Explosives using Pulsed-UV System (Pulsed-UV 시스템을 이용한 염소계 유기화합물 및 화약류 제거에 관한 연구)

  • Lee, Han-Uk;Han, Jonghun;Yoon, Yeomin;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.78-84
    • /
    • 2013
  • This study was conducted in order to evaluate the removal process for long-term contamination sources including chlorinated hydrocarbons (TCE and PCE) and explosive compounds (TNT, RDX, and HMX) in underground water using a pulsed-UV system. Crystallized cells containing the contaminants were placed 10, 20, and 40 cm away from a lamp that emits pulsed-UV rays in order to examine how the removal efficiency is influenced by the distance between the source of the light and the compounds. Chlorinated hydrocarbons were completely removed in 30 minutes with a distance of 10 cm, while PCE was completely removed even with a distance of 20 cm. In the case of explosive compounds, removal efficiencies slightly varied depending on the compounds. The majority of the compounds were perfectly removed with a contact time of 10 minutes. In particular, for RDX, the results showed that complete removal was obtained within one minute, regardless of the distance from the UV source. The amount of light energy is in inverse proportion to the distance, and thus the energy reaching the compounds severely diminishes as the distance increases. Therefore, the removal efficiency decreased with increasing distance in the system.

Effects of Ethanol on the Activities and Inducibility of Trichloroethylene Metabolic Enzyme System in Rat Liver (Ethanol이 Trichloroethylene 대사효소의 활성도와 유도성에 미치는 영향)

  • Kim, Ki-Woong;Kang, Seung-Kyu;Cho, Young-Sook;Lee, Sei-Hui;Moon, Young-Hahn;Choi, Byung-Soon;Park, Sang-Shin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.1 s.49
    • /
    • pp.141-152
    • /
    • 1995
  • This study was performed to find out the influences of ethanol on the metabolism of trichloroethylene(TRI) in rats. TRI in corn oil at the dosage of 150, 300, 600 mg/kg was injected peritoneally once a day for two days to two groups. In one group ethanol(4 g/kg) was taken orally 30 minutes before TRI injection, and the other group ethanol was not. The results of experiments are as follows: 1. The contents of cytochrome P-450 and $b_5$ had inverse relationship with in-jected TRI amounts in both groups. 2. The activity of NADPH P-450 reductase was decreased slowly in TRI injected group related with TRI amount, but decreased drastically in the group pretreated with ethanol. 3. The activity of NADH $b_5$ reductase had relationship with injected nt amount , but the statistical significance was found only in the groups of 300 and 600 mg/kg of TRI injected without relevance to ethanol when compared with the group that was not injected. 4. The activity of ADH was more decreased and ALDH activity was more increased in groups that TRI injected and ethanol was pretreated with ethanol groups than in group without any treatment. These results suggest that ethanol may inhibit epoxide formulation, the first step of TRI metabolism, and change from TCE-OH to TCA also.

  • PDF

A Study on the Water Treatment using Shell Waste (폐패각을 이용한 수처리에 관한 연구)

  • 이민호;정태섭
    • Resources Recycling
    • /
    • v.6 no.3
    • /
    • pp.28-35
    • /
    • 1997
  • Adsorption properities of hcavy metals (Cd, Cu, Fe, Mn, Pb, Zn) and organic compounds (Trichloroethylene and T Tetrachroethy len려 on sh$\xi$1I( oyster and ark shell) were investigated using wat$\xi$r treatment matenals, The shell powder (m띠or C crystal structurc is calcium hydroxide) showed the preference adsorption for heavy metals in order of Mn > Zn > Fe > Cd > eu > P Pb. The high removal capacities of heavy metals arc helicved to be largely due to precipitation by foonation of metal c carhonat,잃 and hydroxides at high pH caused by the $Ca(OH)_2$ component of sl1ell, immobilizatIon of heavy metals in a solid I matrix by calcium‘ and fixation by insoluble organic materials in the oystcr and ark shell. The use of sh려I in water treatment h has the potential to bc benefIcial as a source of inexpensive matcrials‘ moreover, not only treatment of waste but also e environmcntal business including environmental-purification ceramics could be better off by utili낌ng high-valued waste and d developed puri'fication ceramics and media.

  • PDF

Control of Persulfate Activation Rate and Improvement of Active Species Transfer Rate Using Selenium-modified ZVI (셀레늄으로 개질된 영가철을 이용한 과황산 활성화 속도 조절 및 활성종 전달율 향상에 관한 연구)

  • Hee-won Kwon;Hae-Seong Park;In-seong Hwang;Jeong-Jin Kim;Young-Hun Kim
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.57-65
    • /
    • 2023
  • The advanced oxidation treatment using persulfate and zero-valent iron (ZVI) has been evaluated as a very effective technology for remediation of soil and groundwater contamination. However, the high rate of the initial reaction of persulfate with ZVI causes over-consumption of an injected persulfate, and the excessively generated active species show a low transfer rate to the target pollutant. In this study, ZVI was modified using selenium with very low reactivity in the water environment with the aim of controlling the persulfate activation rate by controlling the reactivity of ZVI. Selenium-modified ZVI (Se/ZVI) was confirmed to have a selenium coating on the surface through SEM/EDS analysis, and low reductive reactivity to trichlroethylene (TCE) was observed. As a result of inducing the persulfate activation using the synthesized Se/ZVI, the persulfated consumption rate was greatly reduced, and the decomposition rate of the model contaminant, anisole, was also reduced in proportion. However, the final decomposition efficiency was rather increased, which seems to be the result of preventing persulfate over-consumption. This is because the transfer efficiency of the active species (SO4-∙) of persulfate to the target contaminant has been improved. Selenium on the surface of Se/ZVI was not significantly dissolved even under oxidation conditions by persulfate, and most of it was present in the form of Se/ZVI. It was confirmed that the persulfate activation rate could be controlled by controlling the reactivity of ZVI, which could greatly contribute to the improvement of the persulfate oxidation efficiency.

A Comprehensive Groundwater Modeling using Multicomponent Multiphase Theory: 1. Development of a Multidimensional Finite Element Model (다중 다상이론을 이용한 통합적 지하수 모델링: 1. 다차원 유한요소 모형의 개발)

  • Joon Hyun Kim
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.1
    • /
    • pp.89-102
    • /
    • 1996
  • An integrated model is presented to describe underground flow and mass transport, using a multicomponent multiphase approach. The comprehensive governing equation is derived considering mass and force balances of chemical species over four phases(water, oil, air, and soil) in a schematic elementary volume. Compact and systemati notations of relevant variables and equations are introduced to facilitate the inclusion of complex migration and transformation processes, and variable spatial dimensions. The resulting nonlinear system is solved by a multidimensional finite element code. The developed code with dynamic array allocation, is sufficiently flexible to work across a wide spectrum of computers, including an IBM ES 9000/900 vector facility, SP2 cluster machine, Unix workstations and PCs, for one-, two and three-dimensional problems. To reduce the computation time and storage requirements, the system equations are decoupled and solved using a banded global matrix solver, with the vector and parallel processing on the IBM 9000. To avoide the numerical oscillations of the nonlinear problems in the case of convective dominant transport, the techniques of upstream weighting, mass lumping, and elementary-wise parameter evaluation are applied. The instability and convergence criteria of the nonlinear problems are studied for the one-dimensional analogue of FEM and FDM. Modeling capacity is presented in the simulation of three dimensional composite multiphase TCE migration. Comprehesive simulation feature of the code is presented in a companion paper of this issue for the specific groundwater or flow and contamination problems.

  • PDF

Evaluation of Microbial PCE Reductive Dechlorination Activity and Microbial Community Structure using PCE-Contaminated Groundwater in Korea (사염화에틸렌(PCE)으로 오염된 국내 4개 지역 지하수 내 생물학적 PCE 탈염소화 활성 및 미생물 군집의 비교)

  • Kim Young;Kim Jin-Wook;Ha Chul-Yoon;Kwon Soo-Yeol;Kim Jung-Kwan;Lee Han-Woong;Ha Joon-Soo;Park Hoo-Won;Ahn Young-Ho;Lee Jin-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.52-58
    • /
    • 2005
  • In Korea, little attention has been paid to microbial perchloroethylene (PCE) and/or trichloroethylene (TCE) dechlorination activity and identification of microorganisms involved in PCE reductive dechlorination at a PCE-contaminated aquifer. We performed microcosm tests using the groundwater samples from 4 different contaminated sites (i.e. Changwon A, Changwon B, Bucheon and Yangsan) to assess PCE reductive dechlorination activity. We also adapted molecular techniques to screen what types of known reductive dechlorinators are present at the PCE-contaminated aquifers. In the Changwon A and Changwon B active microcosms where potential electron donors such as sodium propionate, sodium lactate, sodium butyrate, and sodium fumarate, were added, ethylene, an end-product of complete reductive dechlorination of PCE, was detected after a period of 90 days of incubation. In the Bucheon and Yangsan active microcosms, cis-1,2-dichloroethylene (c-DCE) was accumulated without the production of vinyl chloride (VC) and ethylene. Molecular techniques were used to evaluate the microbial community structures in the Changwon B and Yangsan aquifer. We found two sequence types that were closely related to a known PCE to ethylene dechlorinator, named uncultured bacterium clone DCE47, in the Changwon B site clone library. However, in the Yangsan site clone library, no sequence type was closely related to known PCE dechlorinators reported. It is plausible that microorganisms being capable of completely dechlorinating PCE to ethylene may be present in the Changwon B site aquifer. In this study we find that complete PCE reductive dechlorinators are present at some PCE-contaminated sites in Korea. In an engineering point of view this information makes it feasible to apply a biological reductive dechlorination process for remediating PCE- and/or TCE-contaminated aquifers in Korea.

Concentrations of VOCs in Groundwater Associated with Land Uses in Ulsan Area (토지이용에 따른 울산지역 지하수의 VOCs 함량 특성)

  • Yun Uk;Cho Byong-Wook
    • Economic and Environmental Geology
    • /
    • v.37 no.6 s.169
    • /
    • pp.613-629
    • /
    • 2004
  • Contamination of groundwater by volatile organic compounds (VOCs) was investigated for 168 groundwater wells in Ulsan area to study the natural attenuation of organic compounds in the aquifers. As groundwater contamination by VOCs is closely related to land use, 168 groundwater samples were classified into 4 different groups; agricultural, forestry, industrial, and residential & business. From analysis 65 out of 168 groundwater samples contained more than one VOC. Analysis of samples were performed fir 36 halogenated aliphatic hydrocarbons and 25 petroleum hydrocarbons set up by NAWQA of US geological survey. Twelve petroleum hydrocarbons were detected in 26 groundwater wells, but their concentrations were less than 1.5 g/L except for MTBE. Twenty three chlorinated aliphatic hydrocarbons, composed of 11 methanes, 6 ethanes and 6 ethenes, were detected in 63 groundwater samples. The range of methanes concentration was $ND\~330\;/gL,\;ethanes\;ND\~84\;gL$, and PCE and their derivatives $ND\~62\;g/L$. As the study area was comprised of the aerobic/denitrification zones and $Fe^{+3}$ redox condition, most of petroleum hydrocarbons were degraded well, while halogenated hydrocarbons were slowly biodegradation.

제강분진을 반응촉매로 이용한 침출수의 연속산화처리공정

  • 강정우;장윤석;지원현;김성용;배범한;장윤영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.09a
    • /
    • pp.164-167
    • /
    • 2001
  • 본 연구에서는 포항제철소에서 제철부산물로 발생되는 제강분진을 전처리 없이 산화촉매로 사용하여 김포 수도권 매립지의 침출수 처리공정에서 펜톤산화조에 유입되는 원수를 대상으 로 과산화수소를 이용한 연속식 산화처리 실험을 수행하였다. 먼저 회분식 실험결과를 바탕 으로 최적 반응조건에서 lab-scale 연속식 기초반응실험과 자체 설계.제작한 연속산화공정에서의 처리실험을 수행하였다. 또한 기존의 펜톤산화공정에서 Fe 공급원으로 사용되고 있는 FeSO$_4$.7($H_2O$)와의 반응성 비교실험도 수행하였다. 반응기간동안 일정 pH를 유지하기 위해 pH controller를 사용하였으며 침출수 수질은 CODcr로 나타내었다. 반응 pH 3.5, 체류시간 1 hr, 과산화수소 주입량 1,500mg/1에서 제강분진과 FeSO$_4$.7($H_2O$)를 각각 주입하여 수행한 연속처리 기초실험에서는 제강분진을 산화반응촉매로 사용한 경우에 침출수CODcr 처리율 62%, 과산화수소의 분해율 52%를 나타내었다. FeSO$_4$.7($H_2O$)를 산화반응 촉매로 사용한 경우에는 약 65-70%정도의 다소 높은 처리효율을 나타낸 반면에 과산화수소의 소비량은 제강분진의 경우보다 약 20%이상의 높은 값을 나타내었다. 연속산화공정 실험에서는 운전 3시간 이후에 유출수 중의 CODcr과 $H_2O$$_2$의 농도가 안정된 값을 나타내었다. 이 때 산화 반응조의 침출수 CODcr 제거효율은 약 43%이었으며, 처리수의 농도는 현재의 침출수 방류기준 이하로 나타났다. 결론적으로 침출수의 연속식 산화처리 실험결과, 처리효율과 경제성에서 제강분진의 산화촉매활용 공정의 개발 가능성이 매우 높은 것으로 나타났다.ell에 의해 완전분해 되었으며, 함께 존재시 TC는 Fe$^{\circ}$만으로는 분해가 되지 않았지만 cell에 의해 완전분해 되었으며, 함께 존재시 TCE분해에 저해작용을 미치는 것으로 나타났다.술의 첨가가 요구되고 있다. 따라서, 산성광산배수 오염지대에 대해 획일적으로 같은 처리방법을 채택하여 사용하는 것보다 각 지역 또는 광산산성폐수가 유출되어 나오는 광산폐기물의 특성 등을 고려하여 거기에 맞는 기술들을 복합적으로 또는 단독으로 사용하되 처리방법 채택 시 신중을 기할 것이 요망된다.정시에는 SeaWiFS 위성과 관련된 global algorithms 중에서 490nm와 555nm의 복합밴드를 포함하는 OC2 알고리즘(ocean color chlorophyll 2 algorithm)을 사용하는 것이 OC2 series 및 OC4 알고리즘보다 좋은 추정 값을 도출할 수 있을 것으로 기대된다.환경에서는 5일에서 7월에 주로 이 충체의 유충이 발육되고 전파되는 것으로 추측되었다.러 가지 방법들을 적극 적용하여 금후 검토해볼 필요가 있을 것이다.잡은 전혀 삭과가 형성되지 않았다. 이 결과는 종간 교잡종을 자방친으로 하고 그 자방친의 화분친을 사용할 때만 교잡이 이루어지고 있음을 나타내고 있다. 따라서 여교잡을 통한 종간잡종 품종육성 활용방안을 금후 적극 확대 검토해야 할 것이다하였다.함을 보이고 있다.X> , ZnCl$_{3}$$^{-}$같은 이온과 MgCl$^{+}$, MgCl$_{2}$같은 이온종을 형성하기 때문인것 같다. 한편 어떠한 용리액에서던지 NH$_{4}$$^{+}$의 경우 Dv값이 제일 작았다. 바. 본 연구의 목적중의 하나인 인체유해 중금속이온인 Hg(II), Cd(II)등이 NaCl같은 염화물

  • PDF