• Title/Summary/Keyword: 0.9 V to 5 V

Search Result 2,862, Processing Time 0.038 seconds

The study on the scattering ratio at the edge of the block according to the increasing block thickness in electron therapy (전자선 치료 시 차폐블록 두께 변화에 따른 블록 주변 선량에 관한 연구)

  • Park, Zi On;Gwak, Geun Tak;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Kim, Jung Soo;Kwon, Hyoung Cheol;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Purpose: The purpose is to clarify the effect of additional scattering ratio on the edge of the block according to the increasing block thickness with low melting point lead alloy and pure lead in electron beam therapy. Methods and materials: $10{\times}10cm^2$ Shielding blocks made of low melting point lead alloy and pure lead were fabricated to shield mold frame half of applicator. Block thickness was 3, 5, 10, 15, 20 (mm) for each material. The common irradiation conditions were set at 6 MeV energy, 300 MU / Min dose rate, gantry angle of $0^{\circ}$, and dose of 100 MU. The relative scattering ratio with increasing block thickness was measured with a parallel plate type ion chamber(Exradin P11) and phantom(RW3) by varying the position of the shielding block(cone and on the phantom), the position of the measuring point(surface ans depth of $D_{max}$), and the block material(lead alloy and pure lead). Results : When (depth of measurement / block position / block material) was (surface / applicator / pure lead), the relative value(scattering ratio) was 15.33 nC(+0.33 %), 15.28 nC(0 %), 15.08 nC(-1.31 %), 15.05 nC(-1.51 %), 15.07 nC(-1.37 %) as the block thickness increased in order of 3, 5, 10, 15, 20 (mm) respectively. When it was (surface / applicator / alloy lead), the relative value(scattering ratio) was 15.19 nC(-0.59 %), 15.25 nC(-0.20 %), 15.15 nC(-0.85 %), 14.96 nC(-2.09 %), 15.15 nC(-0.85 %) respectively. When it was (surface / phantom / pure lead), the relative value(scattering ratio) was 15.62 nC(+2.23 %), 15.59 nC(+2.03 %), 15.53 nC(+1.67 %), 15.48 nC(+1.31 %), 15.34 nC(+0.39 %) respectively. When it was (surface / phantom / alloy lead), the relative value(scattering ratio) was 15.56 nC(+1.83 %), 15.55 nC(+1.77 %), 15.51 nC(+1.51 %), 15.42 nC(+0.92 %), 15.39 nC(+0.72 %) respectively. When it was (depth of $D_{max}$ / applicator / pure lead), the relative value(scattering ratio) was 16.70 nC(-10.87 %), 16.84 nC(-10.12 %), 16.72 nC(-10.78 %), 16.88 nC(-9.93 %), 16.90 nC(-9.82 %) respectively. When it was (depth of $D_{max}$ / applicator / alloy lead), the relative value(scattering ratio) was 16.83 nC(-10.19 %), 17.12 nC(-8.64 %), 16.89 nC(-9.87 %), 16.77 nC(-10.51 %), 16.52 nC(-11.85 %) respectively. When it was (depth of $D_{max}$ / phantom / pure lead), the relative value(scattering ratio) was 17.41 nC(-7.10 %), 17.45 nC(-6.88 %), 17.34 nC(-7.47 %), 17.42 nC(-7.04 %), 17.25 nC(-7.95 %) respectively. When it was (depth of $D_{max}$ / phantom / alloy lead), the relative value(scattering ratio) was 17.45 nC(-6.88 %), 17.44 nC(-6.94 %), 17.47 nC(-6.78 %), 17.43 nC(-6.99 %), 17.35 nC(-7.42 %) respectively. Conclusions: When performing electron therapy using a shielding block, the block position should be inserted applicator rather than the patient's body surface. The block thickness should be made to the minimum appropriate shielding thickness of each corresponding using energy. Also it is useful that the treatment should be performed considering the influence of scattering dose varying with distance from the edge of block.

Effect of Coexisting Ions on Electrokinetic Injection in Capillary Electrophoresis Analysis (모세관 전기영동 분석에서 계면 동전기 주입에 미치는 공존 이온의 영향)

  • Lee, Kwang-Woo;Jeon, Ji-Young;Lee, Kwang-Pill
    • Analytical Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-42
    • /
    • 1996
  • A rapid analytical method based on capillary electrophoresis is described for the determination of trace anions in high-purity chemicals which is used to prevent corrosion demage in nuclear power plants. Separations are carried out at 20kV using trimethylsilane-coated fused-silica capillary ($70cm{\times}50$ or $75{\mu}m$ i.d.) with the electrolyte of 5mM Chromate(pH=8). Detection was achieved using on-column indirect photometry at 254nm. The simultaneous analysis of inorganic anions, chloride, nitrate, sulfate, azide and phosphate was performed using methods of hydrodynamic(>1ppm) and / or electrokinetic(<1ppm) injection. The results of studies on the coexisting anions on analyte ions shows that peak responses of analyte in hydrodynamic injection is constant without effect of coexisting anions, but those of analysis in electrokinetic injection is strongly dependant upon the kind of coexisting anions and its ionic mobility. The analyte enrichment rate, hence peak response, is positive relationship with the resistance of the sample solution. Thus, appropriate measures, such as standard addition or internal standard technique, must be used to account for differences in conductance of standard and sample solutions.

  • PDF

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

The Identification of the High-Risk Pregnacy, Usign a Simplified Antepartum Risk-Scoring System (단순화된 산전위험득점체계를 이용한 고위험 임부의 확인)

  • Jo, Jeong-Ho
    • The Korean Nurse
    • /
    • v.30 no.3
    • /
    • pp.49-65
    • /
    • 1991
  • This study was carried out to assess the problems with the pregnant women, and check out the risk-factors in the high-risk pregnancies, using a simplified antepartum risk-scoring system, which was revised from Edwards' scoring system to be suitable for Korean situaition. This instrument was included 4 categories, demographic, obstetric, medical and miscellaneous factors. This survey was based on the 1300 pregnant women who were admitted, $x^2$-test, F-test, Pearsons correation, using statistical package SAS in NAS computer system, KIST. The results of the study were as follows; 1. 1313 infants were deliveried of these 560 infants(42.7%) were born to mothers with risk-scores > 7, and 753 infants(57.3%) were born to mothers risk-scores <7. 2. Maternal age" parity, education level, of the demographic factors were significant relation statistically to identify the high risk pregnancies($X^2$=20.88, 42.87, 15.60 P < 0.01). 3. C-section, post term, incompetent cervix, uterine anomaly, polyhydramnios, congenital anomaly, sensitized RH negative, abortion, preeclampsia, excessive size infant, premature, low birth weight infanl, abnormal presentation, perinatal loss, multiple pregnancy, of the obstetric factors were significant relation statistically to identify the high risk-pregnancies. ($X^2$ = 175.96, 87.5, 16.28, 21.78, 9.46, 8. 10, 6.75, 22.9, 64.84, 6.93, 361.43, 185.55, 78.65, 45.52, P < 0.01). 4. Abnormal nutrition, anemia, UTI, other medicalcondition(pulmonary disease, severe influenza), heart disease, V.D., of the miscellaneous and medical factors, were significant relation statistically to identify the high risk-pregnancies. 5. Premature, low birth weight infant, contracted pelvis, abnormal presentation, of the risk factors were significantly related with Apgar score at 1 '||'&'||' 5 minute after birth and neonatal body weight. 6. Apgar score at 1 '||'&'||' 5 minute after, birth and neonatal body weight were significantly negative correlated with risk-score. 7. There were statistically significant difference between risk-score and Apgar score at 1 '||'&'||' 5 minute after birth, 3 group(0-3, 4-6, above 7), and neonatal body weight, 2 group(below 2.5kg, the other group) (F=104.65, 96.61, 284.92, P<0.01). 8. Apgar score at 1 '||'&'||' 5 minute after birth(below 7), and neonatal body weight(below 2.5kg), were significant relation statistically with risk score.($x^2$=65.99, 60.88, 177.07, P<0.01) were 60.8 %, 60% . 9. Correct classifications of morbid infants(l '||'&'||' 5 minute Apgar score < 7) were 77.8%, 83.8% and that of nonmorbid infants(l '||'&'||' 5 minute Apgar score > 7) were 60.8%, 60%. 10. There were statistically significant difference between dislribution of maternal risk-score among the morbid infants(l '||'&'||' 5 minute Apgar score < 7) and non morbid infants(l '||'&'||' 5 minute Apgar score> 7) ($x^2$=64.8, 58.8, P < 0.001). 11. There were statistically significant difference between distribution of morbid infants(l '||'&'||' 5 minute Apgar score < 7) and fetal death. 12. The predictivity for classifying high.risk cases was 12 % and for classifying low-risk cases was 98.3 % in 5 minute Apgar score. Suggestions for further studies are as follows; 1. Contineous prospective studies, using this newly revised scoring system are strongly recommended in the stetric service. 2. Besides risk facto~s used in this study, assessmenl of risks by factors in another scoring system and paralled studies related to perinatal outcome are strongly recommended.

  • PDF

Association between Initial Chest CT or Clinical Features and Clinical Course in Patients with Coronavirus Disease 2019 Pneumonia

  • Zhe Liu;Chao Jin;Carol C. Wu;Ting Liang;Huifang Zhao;Yan Wang;Zekun Wang;Fen Li;Jie Zhou;Shubo Cai;Lingxia Zeng;Jian Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.736-745
    • /
    • 2020
  • Objective: To identify the initial chest computed tomography (CT) findings and clinical characteristics associated with the course of coronavirus disease 2019 (COVID-19) pneumonia. Materials and Methods: Baseline CT scans and clinical and laboratory data of 72 patients admitted with COVID-19 pneumonia (39 men, 46.2 ± 15.9 years) were retrospectively analyzed. Baseline CT findings including lobar distribution, presence of ground glass opacities, consolidation, linear opacities, and lung severity score were evaluated. The outcome event was recovery with hospital discharge. The time from symptom onset to discharge or the end of follow-up (for those remained hospitalized) was recorded. Data were censored in events such as death or discharge without recovery. Multivariable Cox proportional hazard regression was used to explore the association between initial CT, clinical or laboratory findings, and discharge with recovery, whereby hazard ratio (HR) values < 1 indicated a lower rate of discharge at four weeks and longer time until discharge. Results: Thirty-two patients recovered and were discharged during the study period with a median length of admission of 16 days (range, 9 to 25 days), while the rest remained hospitalized at the end of this study (median, 17.5 days; range, 4 to 27 days). None died during the study period. After controlling for age, onset time, lesion characteristics, number of lung lobes affected, and bilateral involvement, the lung severity score on baseline CT (> 4 vs. ≤ 4 [reference]: adjusted HR = 0.41 [95% confidence interval, CI = 0.18-0.92], p = 0.031) and initial lymphocyte count (reduced vs. normal or elevated [reference]: adjusted HR = 0.14 [95% CI = 0.03-0.60], p = 0.008) were two significant independent factors that influenced recovery and discharge. Conclusion: Lung severity score > 4 and reduced lymphocyte count at initial evaluation were independently associated with a significantly lower rate of recovery and discharge and extended hospitalization in patients admitted for COVID-19 pneumonia.

Synergistic Anticancer Effect of the Cinnamomi Cortex Ethanol Extract (CcEE) and Hyperthermia in AGS Human Gastric Cancer Cells (AGS 인체 위암세포에서 육계 에탄올 추출물(CcEE)과 온열치료의 항암 시너지 효과)

  • Park, Sun-Hyang;Ahn, Chae Ryeong;Baek, Seung Ho
    • Herbal Formula Science
    • /
    • v.27 no.1
    • /
    • pp.53-63
    • /
    • 2019
  • Objectives : In this study, we investigated the combination effects of Cinnamomi cortex Ethanol Extract (CcEE) and hyperthermia in the human AGS gastric cancer cell line. Methods : AGS cells were treated with the indicated concentrations of CcEE (0, 50 or $60{\mu}g/mL$) for 1h prior to hyperthermia. And then incubated for a further 30 min at the indicated temperatures (37, 42 or $43^{\circ}C$) in a humidified incubator containing 5% $CO_2$ or a thermostatically controlled water bath for hyperthermia. The cell viability was measured by MTT assay, Morphology assay and Trypan blue assay. To investigate the possible molecular signaling pathways, the activation of mitogen-activated protein kinase (MAPK) proteins (ERK, p38 and JNK) and expression of various anti-apoptotic proteins such as Caspase-3, Caspase-9, p53, Cyclin D1 and MMP-2 were assessed by Western blot analysis. In addition, Annexin V and 7-amino-actinomycin D (7-AAD) staining was performed to examine the apoptotic mechanism. Results : Combination of CcEE with hyperthermia effectively suppressed the cell viability and changed cellmorphology compared with CcEE or hyperthermia treatment alone. Combined treatment also abated the expression of Caspase-3, Caspase-9, Cyclin D1 and MMP-2. Whereas, the expression level of p53 was up-regulated by co-treatment. Moreover, combination treatment enhanced phosphorylation of ERK, p38 and JNK. In addition, this combination increased anti-cancer effect by inducing cell death through the apoptosis. Conclusions : Taken together, all these findings suggest that the combination treatment with CcEE and hyperthermia may have therapeutic potential as a promising approach to patients with stomach cancer.

ROLE OF SYMPATHETIC NERVE ON THE CONTROL OF MICROCIRCULATION IN THE FELINE DENTAL PULP (고양이 치수에서 교감신경에 의한 미세순환조절에 관한 기능적 연구)

  • Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.375-384
    • /
    • 1996
  • The purpose of this study was to investigate the functional involvement of sympathetic nerve in the control of the microcirculation in the dental pulp with the aim of elucidation of the involvement of neuropeptides and sympathetic nerve in neurogenic inflammation. Experiments were done on the 7 cats anesthetised with sodium pentobarbital, and sympathetic nerve to the' dental pulp was stimulated electrically (10 Hz, 4 V, 1.5 ms, 3.5 mins). Ana-adrenoceptor antagonist phentolamine and a neuropeptide Y antagonist D-myo-inositol-1,2,6-trisphosphate (PP56) were injected close intra-arterially into the dental pulp without changing the systemic blood pressure. The probe of laser Doppler flowmeter was placed on the buccal surface of ipsilateral canine teeth to the stimulation, and pulpal blood flow was measured. Stimulation of the sympathetic nerve decreased pulpal blood flow by $55.24{\pm}7.74\;%$ (mean${\pm}$SEM, n = 13). Stimulation of the sympathetic nerve following the injection of the ${\alpha}$-adrenoceptor antagonist phentolamine ($0.1{\mu}g$/kg) caused decrease of pulpal blood flow by $14.35{\pm}3.43%$ (mean${\pm}$SEM, n=5). Phentolamine attenuated the sympathetic nerve-induced pulpal blood flow decrease by $74.02{\pm}9.32%$ (mean${\pm}$SEM) Stimulation of the sympathetic nerve following the injection of the neuropeptide Y antagonist PP56 (2.3 mg/kg) caused decrease of pulpal blood flow by $30.64{\pm}7.92%$ (mean${\pm}$SEM, n=6). PP56 attenuated the sympathetic nerve-induced pulpal blood flow decrease by $44.37{\pm}11.01%$ (mean${\pm}$SEM). These data provide evidences of the co-contribution of nerepinephrine and neuropeptide Y on the sympathetic nerve-induced vasoconstriction in the feline dental pulp. In addition, they show functional evidences that sympathetic nerve plays an active role in controlling the microcirculation of the dental pulp.

  • PDF

Fault Current Limitation Characteristics of the Bi-2212 Bulk Coil for Distribution-class Superconducting Fault Current Limiters (배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성)

  • Sim, Jung-Wook;Lee, Hai-Gun;Yim, Sung-Woo;Kim, Hye-Rim;Hyun, Ok-Bae;Park, Kwon-Bae;Lee, Bang-Wook;Oh, Il-Sung;Kim, Ho-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.277-281
    • /
    • 2007
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter (SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of $200V_{rms}$ and fault current of $12kA_{rms}\;and\;25kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of $12kA_{rms}\;and\;25kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}\;within\;0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLS.

Fault current limitation characteristics of the Bi-2212 bulk coil for distribution-class superconducting fault current limiters (배전급 초전도 한류기 개발을 위한 Bi-2212 초전도 한류소자의 사고전류 제한 특성)

  • Sim, Jung-Wook;Kim, Hye-Rim;Yim, Seong-Woo;Hyun, Ok-Bae;Lee, Hai-Gun;Park, Kwon-Bae;Kim, Ho-Min;Lee, Bang-Wook;Oh, Il-Sung;Breuer, Frank;Bock, Joachim
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.639-640
    • /
    • 2006
  • We investigated fault current limitation characteristics of the resistive superconducting fault current limiter(SFCL) which consisted of a Bi-2212 bulk coil and a shunt coil. The Bi-2212 bulk coil and the shunt coil were connected in parallel. The Bi-2212 bulk coil was placed inside the shunt coil to induce field-assisted quench. The fault test was conducted at an input voltage of 200 $V_{rms}$ and fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$. The fault conditions were asymmetric and symmetric, and the fault period was 5 cycles. The test results show that the SFCL successfully limited the fault current of 12 $kA_{rms}$ and 25 $kA_{rms}$ to below $5.5{\sim}6.9kA_{peak}$ within $0.64{\sim}2.17$ msec after the fault occurred. Limitation was faster under symmetric fault test condition due to the larger change rate of current. We concluded that the speed of fault current limitation was determined by the speed of current rise rather than the amplitude of a short circuit current. These results show that the Bi-2212 bulk coil is suitable for distribution-class SFCLs.

  • PDF

Genetic Variability in the Fodder Yield, Chemical Composition and Disappearance of Nutrients in Brown Midrib and White Midrib Sorghum Genotypes

  • Singh, Sultan;Prasad, S.V.Sai;Katiyar, D.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1303-1308
    • /
    • 2003
  • Samples of eleven brown midrib (ICSU 96031, ICSU 93046, ICSU 96082, ICSU 96078, ICSU 96075, ICSU 95101, ICSU 96034, ICSU 96063, ICSU 45116, ICSA 93-3 and ICSA 3845 X 3816) and nine white midrib genotypes (ICSU 96050, ICSU 96030, ISU 95082, SSG 59-3, FSHI 93-1, FSHI 2219A X 3211, HC 171, ICSA 93-2 and ICSA 93-1) based on their phenotypic appearance were collected at 50 per cent flowering from the sorghum germplasm grown at Research farm of IGFRI, Jhansi. These genotypes were evaluated with respect to crude protein, fiber composition, in-sacco dry matter, OM, cell wall components disappearance/digestibility besides the fodder yield, total phenolic and availability index values. Brown midrib genotypes were lower (p<0.05) in NDF, ADF, cellulose and acid detergent lignin concentration than white midrib genotypes. Mean NDF, ADF, cellulose and lignin contents were 69.4, 42.1, 35.4 and 5.7% in brown mid rib vis-a vis 75.8, 47.5, 39.6 and 7.3% in white mid rib genotypes. Nonsignificant (p>0.05) differences were observed in dry matter, crude protein and organic matter contents between brown midrib and white midrib genotypes. Phenolic contents were significantly (p<0.05) lower in browm mid rib (0.2) than white mid rib (0.3%) sorghum. Brown midrib genotypes exhibited significantly (p<0.05) higher in-sacco DM, OM and CP disappearance than normal (white midrib) genotypes. The mean degradability of DM, OM and CP was 64.1, 62.6 and 79.6% in brown mid rib and 53.1, 54.0 and 76.6% in white mid rib genotypes, respectively. There were no significant (p>0.05) differences between genotypes in extent of fiber fraction degradability though in-sacco NDF and ADF degradability was more by 5 and 4 units, respectively in brown midrib genotypes vis-a-vis white midrib genotypes. Average fodder yield (green and dry g/plant) and availability index (%) values were significantly (p<0.05) higher for brown midrib (474.2, 129.8 and 80.4) genotypes than white midrib (375.0, 104.8 and 69.2) genotypes. Lignin contents had significant negative correlation with DM, OM, NDF and ADF degradability. The results of the study revealed that brown midrib genotypes are superior not only with regard to chemical entities and disappearance of DM and fiber fractions but also better in respect of fodder yield and availability index values. Thus, brown midrib sorghum strains may be useful in increasing digestibility, intake, feed efficiency and animal performance.