Step-Down Characteristics of Multi-layed Piezo Transformer for Transverse Vibration Mode (경방향 진동모드를 이용한 적층형 압전변압기의 강압특성)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.340-343
    • /
    • 2003
  • This paper presents characteristics of piezo transformer for AC-DC converter. This transformer uses transverse vibration mode and the origin of the structure was the ring dot type transformer. Because, the ring dot type transformers produce only step-up phenomenon, we made a multi-layered ring dot structure for a step-down output. The characteristics of the transformer were simulated by using the ANSYS. And frequency and voltage were measured by changing the load resistance and current. Frequencies that have the maximum output voltage and current were gradually increased, when the resistance were increased. Output voltage and current show a stable linearity according to the input voltage. The maximum output power was expected greater than 20 [W]. So, we expect that this type of multi-layered step-down ring dot transformer can be adopted for a small AC adapters.

  • PDF

Fabrication and Characteristics of Ring-Dot type Piezoelectric Transformer (Ring-dot형 감압형 압전변환기의 제작과 특성)

  • Nam, Sung-Jin;Lee, Yeung-Min;Nam, Hyo-Duk;Sohn, Joon-Ho;Lee, Joon-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.722-725
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum output voltage appears increased about 0.2% as the load resistance increased from 10 to $150\Omega$. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 $V_{PP}$ and $120\Omega$, respectively.

  • PDF

Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode (ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가)

  • Yang, Chaofan;Kim, Seongik;Cho, Jong-Rae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.

Audio-based COVID-19 diagnosis using separable transformer (트랜스포머를 이용한 음성기반 코비드19 진단)

  • Seungtae Kang;Gil-Jin Jang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.221-225
    • /
    • 2023
  • In this paper, we proposed an efficient method for rapid diagnosis of COVID-19 by voice. A novel Strided Convolution Separable Transformer (SC-SepTr) is proposed by modifying the conventional Separable Transformer (SepTr) for audio signal recognition. The proposed method reduces the memory and computational requirements to enable rapid diagnosis of COVID-19. As a result of experiments on Coswara, it was shown that the proposed method perform rapid diagnosis with guaranteeing Area Under the Curve (AUC) performance even for a relatively small amount of learning data.

Analysis on Fault Current Limiting Characteristics of Three-Phase Transformer Type SFCL using Double Quench According to Three-Phase Ground-Fault Types (이중퀜치를 이용한 삼상변압기형 초전도한류기의 삼상지락 고장 종류에 따른 고장전류 제한 특성 분석)

  • Shin-Won Lee;Tae-Hee Han;Sung-Hun Lim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.614-619
    • /
    • 2023
  • The fault current limiting characteristics of three-phase transformer type superconducting fault current limiter (SFCL), which consisted of three-phase primary and secondary windings wound on E-I iron core, one high-TC superconducting (HTSC) element connected with the secondary winding of one phase and another HTSC element connected in parallel with other two secondary windings of two phases, were analyzed. Unlike other three-phase transformer type SFCLs with three HTSC elements, three-phase transformer type SFCL using double quench has the merit to perform fault current limiting operation for three-phase ground faults with two HTSC elements. To verify its proper three-phase ground fault current limiting operation, three-phase ground faults such as single-line ground, double-line ground and triple-line ground faults were generated in three-phase simulated power system installed with three-phase transformer type SFCL using double quench. From analysis of its fault current limiting characteristics based on tested results, three-phase transformer type SFCL using double quench was shown to be effectively operated for all three-phase ground faults.

Structured Pruning for Efficient Transformer Model compression (효율적인 Transformer 모델 경량화를 위한 구조화된 프루닝)

  • Eunji Yoo;Youngjoo Lee
    • Transactions on Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 2023
  • With the recent development of Generative AI technology by IT giants, the size of the transformer model is increasing exponentially over trillion won. In order to continuously enable these AI services, it is essential to reduce the weight of the model. In this paper, we find a hardware-friendly structured pruning pattern and propose a lightweight method of the transformer model. Since compression proceeds by utilizing the characteristics of the model algorithm, the size of the model can be reduced and performance can be maintained as much as possible. Experiments show that the structured pruning proposed when pruning GPT-2 and BERT language models shows almost similar performance to fine-grained pruning even in highly sparse regions. This approach reduces model parameters by 80% and allows hardware acceleration in structured form with 0.003% accuracy loss compared to fine-tuned pruning.

Transformer Based Deep Learning Techniques for HVAC System Anomaly Detection (HVAC 시스템의 이상 탐지를 위한 Transformer 기반 딥러닝 기법)

  • Changjoon Park;Junhwi Park;Namjung Kim;Jaehyun Lee;Jeonghwan Gwak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.47-48
    • /
    • 2024
  • Heating, Ventilating, and Air Conditioning(HVAC) 시스템은 난방(Heating), 환기(Ventilating), 공기조화(Air Conditioning)를 제공하는 공조시스템으로, 실내 환경의 온도, 습도 조절 및 지속적인 순환 및 여과를 통해 실내 공기 질을 개선한다. 이러한 HVAC 시스템에 이상이 생기는 경우 공기 여과율이 낮아지며, COVID-19와 같은 법정 감염병 예방에 취약해진다. 또한 장비의 과부하를 유발하여, 시스템의 효율성 저하 및 에너지 낭비를 불러올 수 있다. 따라서 본 논문에서는 HVAC 시스템의 이상 탐지 및 조기 조치를 위한 Transformer 기반 이상 탐지 기법의 적용을 제안한다. Transformer는 기존 시계열 데이터 처리를 위한 기법인 Recurrent Neural Network(RNN)기반 모델의 구조적 한계점을 극복함에 따라 Long Term Dependency 문제를 해결하고, 병렬처리를 통해 효율적인 Feature 추출이 가능하다. Transformer 모델이 HVAC 시스템의 이상 탐지에서 RNN 기반의 비교군 모델보다 약 1.31%의 향상을 보이며, Transformer 모델을 통한 HVAC의 이상 탐지에 효율적임을 확인하였다.

  • PDF

Survey of Optical Current Sensor and Optical Voltage Sensor for Electric Power Systems (전력용 광 전류, 전압 센서 연구 동향 조사)

  • Kim, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.270-273
    • /
    • 2001
  • In this paper, some of optical current transformers and optical potential transformers for extra high voltage system are introduced. The optical current transformer and optical potential transformer will be adopted in the near future, because of increasing demands of high accuracy and good reliability of current transformer and potential transformer. The application cases of optical current transformers and optical potential transformers are also introduced.

  • PDF

Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array (Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구)

  • Lee, Jog-Kil;Lee, Seung-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF

A Study on the Streaming Electrifacation in Forced Oil Cooled Transformer (강제유 냉각 변압기의 유동계전에 관한 연구)

  • 권동진;강창구;곽희로;김재철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.53-56
    • /
    • 1990
  • When oil flows and rubs against various materials in transformer, electrostatic charges are separated at the interface of the oil and the solid material. Using simplified model transformer, authors investigated the basic characteristics of the streaming electrifica-tion which is caused by forced oil circulation. As the result of the study, it was concluded that the electrostatic charge distribution on test pipe of the transformer showed larger leakage current at the inlet and the outlet.

  • PDF