• Title/Summary/Keyword: -energy-dispersive x-ray-

Search Result 1,064, Processing Time 0.033 seconds

Enhanced Electrochemical Properties of Surface Modified LiMn2O4 by Li-Fe Composites for Rechargeable Lithium Ion Batteries

  • Shi, Jin-Yi;Yi, Cheol-Woo;Liang, Lianhua;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.309-314
    • /
    • 2010
  • The surface modified $LiMn_2O_4$ materials with Li-Fe composites were prepared by a sol-gel method to improve the electrochemical performance of $LiMn_2O_4$ and were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS), and transmission electron microscopy (TEM)-EDS. XRD results indicate that all the samples (modified and pristine samples) have cubic spinel structures, and XRD, XPS, and TEM-EDS data reveal the formation of $Li(Li_xFe_xMn_{2-2x})O_4$ solid solution on the surface of particles. For the electrochemical properties, the modified material demonstrated dramatically enhanced reversibility and stability even at elevated temperature. These improvements are attributed to the formation of the solid solution, and thus-formed solid solution phase on the surface of $LiMn_2O_4$ particle reduces the dissolution of Mn ion and suppresses the Jahn-Teller effect.

Heavy Metal Removal using Sawdust (톱밥을 이용한 중금속 제거에 관한 연구)

  • Jeon, Choong;Kim, Jung Hwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.15 no.2
    • /
    • pp.81-88
    • /
    • 2007
  • A study on the removal of heavy metals using sawdust was performed. Among heavy metals such as lead, copper and cadmium ions, uptake capacity of lead ions was the highest as about 0.22 mmol/g-dry mass at pH 4. The surface condition and existence of lead ions onto the sawdust was confirmed by the FT-IR, SEM (Scanning Electron Microscopy), and EDX (Energy Dispersive X-ray) instrumental analyses. When 0.5g of sawdust was added to initial lead solution (100ppm) removal efficiency was approximately 90%. Isothermal adsorption curve for lead ions was described by the Langmuir model equation and experimental data well fitted to model equation. Most adsorption for lead ions was also completed within 60min and pH of lead solution from 5.8 to 4.5 decreased with time.

  • PDF

Cleanliness Test by Spray-Type Cleaning Agent for Electronic and Semiconductor Equipment (전자·반도체용 스프레이 분사형 세정제에 대한 청정도 평가)

  • Heo, Hyo Jung;Row, Kyung Ho
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • A spray-type cleaning agent in utilizing dust-remover on PCB was chosen to study the cleanliness test and efficiency. In order to choose alternative environmental-friendly cleaning agents, it is important that the systematic selection procedures should be introduced and applied through the evaluation of their cleaning ability, environmental characteristics, and economical factors, and that the objective and effective evaluation methods of cleanliness should be established for the industry. A novel cleaning evaluation method with scanning electron microscopy/energy-dispersive X-ray analysis of surface observation evaluation method and an infra-red thermography camera(THERMOVISION A20 model) was studied in this work. The sound card(CT-2770 model) cut by $2{\times}2cm$ size was used as a part, and before and after the spray cleaning, the cleanliness was observed by the image analyzer of SEM and further the removal efficiency of dust was quantitatively evaluated by the component analysis of EDX. For the parts of P4TE model motherboard and IPC-A-36 PCB plate, before and after the spray cleaning, temperature differences were measured and compared at room temperature and 50 oven temperature by an infra-red thermography camera in the contaminants of dust and iron powder.

Generalized Pulp Stones of Primary Dentition in a Patient with Molar-Incisor Malformation : A Case Report (Molar-Incisor Malformation 환자의 유치열 내 전반적인 치수석 관찰의 증례 보고)

  • Lee, Dongyun;Shin, Jisun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.337-343
    • /
    • 2020
  • Molar-incisor malformation (MIM) is a new type of root anomaly reported recently. The characteristics of MIM are dysplastic root formations, constriction of pulp chambers and presence of calcified matrices at the level of cementoenamel junction in permanent first molars and primary second molars. In some cases, permanent maxillary incisors are also affected. The permanent first molars of the patient in this case report were affected with MIM. Generalized pulp stones were observed in overall primary dentition. Micro-computed tomography (micro-CT) imaging and scanning electron microscope-energy dispersive X-ray spectrometer analysis were performed on the extracted mandibular first molar and maxillary primary second molar of the patient. Micro-CT images revealed the discontinuity of enamel directly connected to an accessory canal of the root.

Application of Spectrochemical Analysis in the Study of Archaeological Textiles (복식유물의 연구에 있어서 분광화학분석의 활용)

  • 안춘순
    • Journal of the Korean Society of Costume
    • /
    • v.49
    • /
    • pp.49-63
    • /
    • 1999
  • This research utilized the Energy Dispersive X-ray Spectroscopy(EDS) and the Inductively Coupled Plasma Mass Spectrometry in the analysis of chemical elements present among the textiles exhumed from Kupori Hwasung-kun Kyunggi-do. The two research objectives were: first to examine the elements present and their percent presence in Kupori samples: second to investigate whether the elements are part of mordant substances which could have been used when dyeing the KUpori textiles in the past. To meet such research purposes standard silk fabric was dyed with Sophorajaponica using alum and iron mordants. For alum mordant unpurified general alum and potassium aluminum sulfate(AlK(SO4)2). iron sulfate(FeSO4·7H2O) were used, From the results of EDS and ICP-Mass analysis the following conclusions were drawn. 1 According to the EDS analysis 9 elements Ca, S, Al, Si, K, Fe, P, Mg and Na were detected. 2. ICP-Mass result of the mordant chemicas showed high amount of A, Al and k present in alum mordants and S and Fe present in iron mordants. 3. Comparison of the ICP-Mass results of the mordant chemicals and those of the standard dyed samples suggested that the amount presence of Al and Fe is a strong indication of the usage of alum and iron mordants respecticely in an unknown dyed textile. 4, In the washed Kupori textiles Fe showed a relatively higher rate of presence in the samples Therefore it can be conjectured that those Kupori textiles were dyed with iron mordant based on the result of the above number 3. 5. It is probable that the other elements detected from the Kupori samples were incorporated into the textiles as part of the soil debris produced from the degradation of the dead within the coffin or the earth debris. They can also be part of the inorganic compounds inherent in the silk textiles themselves before dyed. 6. Among the elements it is likely that Ca which showed a high degree of presence among the unwashed samples was part of the inorganic compound inferent in the silk textiles.

  • PDF

ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS (임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구)

  • Kim, Yong-Jae;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

Effects of Fatigue Strength by Solder Ball Composition (솔더볼 조성에 의한 피로강도의 영향)

  • 김경수;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.127-131
    • /
    • 2004
  • Package reliability test was conducted to investigate the effect of solder composition on the ball fatigue strength for BGA (Ball Grid Array) packaging. The test pieces are assembled using eutectic composition 63Sn/37Pb, 62Sn/36Pb/2Ag, and 63Sn/34.4Pb/2Ag/0.5Sb solder after pre-conditioning at MRT Lv 3 (Moisture Resistance Test Level) and then conducted under T/C (Temperature Cycle test). For each case, the ball shear strength was obtained and micro structure photos were taken. SEM (scanning electron microscope) and EDX (Energy Dispersive X-ray) were used to the analyze failure mechanism. The growth rate of Au-Sn intermetallic compound in Sn63Pb34.5Ag2Sb0.5 solder was slow when compared to 63Sn/37Pb solder and 62Sn/36Pb/2Ag solder. The degradation of shear strength of solder balls caused by solder composition was discussed.

Efficient Stripping of High-dose Ion-implanted Photoresist in Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 고농도이온주입 포토레지스트의 효율적인 제거)

  • Kim, Do-Hoon;Lim, Eu-Sang;Lim, Kwon-Taek
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • A mixture of supercritical carbon dioxide and a co-solvent was employed to strip a high-dose ion-implanted photoresist (HDIPR) from the surface of semiconductor wafers. The stripping efficiency was highly improved by the physical force generated from a ultrasonication tip inside the reactor. In addition, helium gas was injected in the reactor as a barrier gas before the introduction of pure supercritical $CO_2$ ($scCO_2$), which reduced the rinsing time significantly. The effect of co-solvents on the stripping efficiency was investigated. The wafer surfaces were analyzed by scanning electron microscopy and by an energy dispersive X-ray spectrometer.

Calcium pyrophosphate dihydrate deposition disease in the temporomandibular joint: diagnosis and treatment

  • Kwon, Kwang-Jun;Seok, Hyun;Lee, Jang-Ha;Kim, Min-Keun;Kim, Seong-Gon;Park, Hyung-Ki;Choi, Hang-Moon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.19.1-19.6
    • /
    • 2018
  • Background: Calcium pyrophosphate dihydrate deposition disease (CPDD) is a rare disease in the temporomandibular joint (TMJ) space. It forms a calcified crystal mass and induces a limitation of joint movement. Case presentation: The calcified mass in our case was occupied in the left TMJ area and extended to the infratemporal and middle cranial fossa. For a complete excision of this mass, we performed a vertical ramus osteotomy and resected the mass around the mandibular condyle. The calcified mass in the infratemporal fossa was carefully excised, and the segmented mandible was anatomically repositioned. Scanning electronic microscopy (SEM)/energy-dispersive X-ray spectroscopy (EDS) microanalysis was performed to evaluate the calcified mass. The result of SEM/EDS showed that the crystal mass was completely composed of calcium pyrophosphate dihydrate. This result strongly suggested that the calcified mass was CPDD in the TMJ area. Conclusions: CPDD in the TMJ is a rare disease and is difficult to differentially diagnose from other neoplasms. A histological examination and quantitative microanalysis are required to confirm the diagnosis. In our patient, CPDD in the TMJ was successfully removed via the extracorporeal approach. SEM/EDS microanalysis was used for the differential diagnosis.

Polyaniline/SiO2 Catalyzed One-pot Mannich Reaction: An Efficient Synthesis of β-amino Carbonyl Compounds (Polyaniline/SiO2를 이용한 one-pot Mannich 반응: β-amino carbonyl 화합물의 효율적인 합성)

  • Yelwande, Ajeet A.;Arbad, Balasaheb R.;Lande, Machhindra K.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.4
    • /
    • pp.644-649
    • /
    • 2011
  • Polyaniline/$SiO_2$ catalyzed one-pot mannich reaction of acetophenone, aromatic aldehydes and aromatic amines are carried out in ethanol to afford various ${\beta}$-amino ketones. The various wt% of polyaniline were supported on pure silica synthesized by using chemical oxidative method. The catalyst prepared has been characterized by means of thermal analysis (TG-DTA), X-ray diffraction (XRD), scanning electron microscopy (SEM) energy dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FT-IR). Solvent stability of catalyst was tested using UV-Visible spectroscopy. This protocol has several advantages such as high yield, simple work up procedure, non-toxic, clean, easy recovery and reusability of the catalyst.