• Title/Summary/Keyword: 힘 측정

Search Result 564, Processing Time 0.027 seconds

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

A Study on the Health Effects of Pesticide Exposure among Farmers (농약살포 농민의 농약노출로 인한 건강피해에 관한 연구)

  • Lee, Kyoung-Mu;Min, Sun-Young;Chung, Moon-Ho
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.2
    • /
    • pp.245-263
    • /
    • 2000
  • This study was conducted to provide the basic data about the health effects of pesticide exposure among farmers for agricultural health study. We analyzed 412 self-administered questionnaires collected from the male farmers who spray pesticides in Kyoung-ju area, Korea. Survey questions were about chronic symptoms, acute symptoms while pesticide spraying, pesticide intoxication accident, safety rules, protective equipments etc. The correlations among the variables related to pesticide exposure and the factors in acute pesticide poisoning and chronic symptoms of farmers were also analyzed. For chronic symptoms, the prevalence of 'tiredness and languor', 'lumbago', 'nocturia', 'shoulder pain', 'numbness', and, for acute symptoms while pesticide spraying, the experience rate of 'itching sense of skin', 'dizziness/headache', 'fatigue', 'eye glaring' were high compared with other symptoms. For 'experience of intoxication accident by pesticide in family', 7.1% of the subjects experienced the accident and the causes were pesticide spraying, food contamination by pesticide, suicide etc. Among safety rules, 'take a bath after spraying', 'change clothes after spraying' were kept relatively well, and, for protective equipments, hat, boots, mask, gloves, protective clothes(lower) were put on relatively well. The factors associated with acute pesticide poisoning were the extent of keeping safety rules, spraying time, orchard cultivation, agricultural area and spraying days per year etc. And the factors associated with chronic symptoms were acute symptoms while pesticide spraying, agricultural area, farming career, extent of keeping safety rules, extent of agricultural work and the pesticide exposure index etc. From these results, it is suggested that to reduce the health effects by pesticide exposure among farmers, the education to promote to keep safety rules and wear protective equipments, and information services should be recommended. And further studies on the long term health effects of pesticide exposure among farmers are required.

  • PDF

Analysis of Ecotype, Growth and Development, Yield and Feed Value of Kenaf (Hibiscus cannabinus L.) Genetic Resources (케나프 수집 유전자원의 생태형·생육특성 및 수량과 사료가치 분석)

  • Kang, Chan-Ho;Yoo, Young-Jin;Choi, Kyu-Hwan;Kim, Hyo-Jin;Shin, Yong-Kyu;Lee, Gong-Jun;Ko, Do-Young;Song, Young-Ju;Kim, Chung-Kon
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.556-566
    • /
    • 2014
  • In this study, we collected 29 Kenaf (Hibiscus cannabinus L.) genetic resources from 10 countries to confirm the possibility of the introduction into Korea. The Kenaf (Hibiscus cannabinus L.) has the broad industrial use like feed and the 5 times more strong $CO_2$ absorption capacity compared to general plant. So recently it is considered as a good industrial source. We analyzed ecotype, growth and development, yield and feed value of collected resources. They were divided into 3 groups depending on flowering time, early maturing type blooming in early July, mid-late maturing type blooming from end of August to early September and late maturing type blooming in end of October. Early maturing type could get fruitful seed but dropped yield (average 7,895 kg/10a) and late maturing type could get high yield (average 12,572 kg/10a) but deletion. The other side mid-late maturing type could get yield over a certain level (average 11,207 kg/10a) and fruitful seed was ensured. The yields analyzed by resources indicated that K12 (Hongma 300) collected in China, K25 from India, K22 from Russia and K21 (Khonkaen 60) variety from China were more than 13,500 kg per 10a. Feed value of early maturing type had inclined to more better than other types, but like dry digestible matter (DDM) and dry matter intake (DMI) of some late maturing types like K12, K21, K22 which had a high yielding ability were more better than that of early maturing types'. So relative feed value (RFV) which considered comprehensive item for feed value were indicated K21 was 102.5, K12 was 116.2 and K22 was 120.2. 'Jangdae' the variety developed in Korea which could complement of other types' had a good quality for yield 10,975 kg/10a and 12.5% crude protein content and 101.9 of the relative feed value. So we need to be taken power to collection of mid-late maturing types resources.

Image Comparisons using a Diethylenetriaminetriacetic Acid Derivative and Gd-DTPA (Diethylenetriaminetriacetic acid 유도체와 Gd-DTPA와의 영상비교)

  • Cho, Jung-Keun;Lee, Chai-Ho;Han, Tae-Jong;Lim, Cheong-Hwan;Kim, Jung-Nam;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.210-216
    • /
    • 2008
  • In this study, image comparisons were carried out using a MRI contrast medium which was derived by mixing a polyaminocarboxylic ligand and a gadolinium (III) transition metal which is paramagnetic and has good neutron absorbing capabilities with Gd-DTPA which is currently being used widely in the clinical setting. By using a 1.0T (Harmony, SIEMENS) MR equipment, phantoms of which 100cc of saline was diluted with a diethylenetriaminetriacetic acid derivative and Gd-DTPA were imaged. The amount of diethylenetriaminetriacetic acid and Gd-DTPA which was diluted into the 100cc of saline was 0.05mmol/L, 0.1mmol/L, 0.15mmol/L, 0.2mmol/L, 0.3mmol/L, 0.5mmol/L, 1.0mmol/L, 2.0mmol/L, 3.0mmol/L and 4.9mmol/L respectively. Head coils were used and while fixing the SE pulse sequence and image variable (as TE is 14ms, 1NEX with a 256x201 matrix), the signal intensity and simple contrast ratios according to changing concentrations and TR were compared with various TR at 300ms, 400ms, 500ms, 600ms, 700ms, 800ms, 900ms, 1000ms, 1200ms, 1400ms and 1600ms. According to the comparison results of the signal intensity of the image based on changes in contrast medium concentrations and TR, the differences in signal intensity between the two contrast mediums were found to be small at $1.0{\sim}2.0mmol/L$ when the highest signal intensity was achieved. However, at concentrations of 1.0mmol/L or less, the signal intensity was markedly higher in the Diethylenetriaminetriacetic acid derivative than in the Gd-DTPA complex. It was also found that the differences in the signal intensities demonstrated by the concentrations of the contrast mediums were affected by the TR. Accordingly, the efficacy of the Diethylenetriaminetriacetic acid derivative was shown to be better than the Gd-DTPA and also possible to get the optimum image quality by the use of an appropriate TR with appropriate concentrations of contrast medium.

The effects of short-term application of calcium hydroxide on dentin fracture strength (단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향)

  • Shin, Eun-Jung;Park, Yeong-Joon;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.425-430
    • /
    • 2011
  • Objectives: This in vitro study investigated whether short-term application of calcium hydroxide in the root canal system for 1 and 4 wk affects the fracture strength of human permanent teeth. Materials and Methods: Thirty two mature human single rooted mandibular premolars in similar size and dentin thickness without decay or restorations were hand and rotary instrumented and 16 teeth vertically packed with calcium hydroxide paste and sealed coronally with caviton to imitate the endodontic procedure and the other 16 teeth was left empty as a control group. The apicies of all the samples were sealed with resin, submerged in normal saline and put in a storage box at $37^{\circ}C$ to mimic the oral environment. After 1 and 4 wk, 8 samples out of 16 samples from each group were removed from the storage box and fracture strength test was performed. The maximum load required to fracture the samples was recorded and data were analysed statistically by the two way ANOVA test at 5% significance level. Results: The mean fracture strengths of two groups after 1 wk and 4 wk were similar. The intracanal placement of calcium hydroxide weakened the fracture strength of teeth by 8.2% after 4 wk: an average of 39.23 MPa for no treatment group and 36.01 MPa for CH group. However there was no statistically significant difference between experimental groups and between time intervals. Conclusions: These results suggest that short term calcium hydroxide application is available during endodontic treatment.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Axial wall thickness of zirconia abutment in anterior region (전치부 지르코니아 지대주의 축벽 두께)

  • Moon, Seung-Jin;Heo, Yu-Ri;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the proper axial thickness of zirconia abutment applied to implant in the anterior region. Materials and methods: Zirconia abutments were prepared at different axial wall thickness by processing pre-sintered zirconia blocks via CAD/CAM to obtain equal specimens. The abutments were each produced with a thickness of 0.5 mm (Group 1), 0.8 mm (Group 2), 1.2 mm (Group 3), or 1.5 mm (Group 4). The implant used in this study was a external connection type one (US, Osstem, Pussan, Korea) product and the zirconia abutment was prepared via replication of a cemented abutment. The crowns were prepared via CAM/CAM with a thickness of 1.5 mm and were cemented to the abutments using $RelyX^{TM}$ UniCem cement. A universal testing machine was used to apply load at 30 degrees and measure fracture strength of the zirconia abutment. Results: Fracture strength of the abutments for Group 1, Group 2, Group 3, and Group 4 were $236.00{\pm}67.55N$, $599.00{\pm}15.80N$, $588.20{\pm}33.18N$, and $97.83{\pm}98.13N$, respectively. Group 1 showed a significantly lower value, as compared to the other groups (independent Mann-Whitney U-test. P<.05). No significant differences were detected among Group 2, Group 3, and Group 4 (independent Mann-Whitney U-test. P>.05). Conclusion: Zirconia abutment requires optimal thickness for fracture resistance. Within the limitation of this study, > 0.8 mm thickness is recommended for zirconia abutment in anterior implants.

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Effect of Curing Additives on Color Property of Smoked Duck Meat (염지제가 훈연오리의 육색 특성에 미치는 영향)

  • Kang, Geunho;Cho, Soohyun;Seong, Pil-Nam;Park, Kyoungmi;Kang, Sun Mun;Park, Beom-Young
    • Korean Journal of Poultry Science
    • /
    • v.40 no.3
    • /
    • pp.179-185
    • /
    • 2013
  • This study was conducted to investigate the effect of curing additives on color property of smoked duck meat. Curing process of samples was performed one of the following treatments: C, non-curing: T1, 2.43% salt: T2, 2.43% salt + 0.49% tripolyphosphate (TPP): T3, 2.43% salt + 0.49% TPP + 0.002% nitrite: T4, 4.76% duck seasoning: and T5, 1.47% salt + 0.24% TPP + 0.2% L-ascorbic acid. Instrumental meat color of both breast and thigh of smoked duck showed that the CIE $a^*$ value of the T4 was significantly (p<0.05) higher than that of the other treatments, whereas T5 had a significantly (p<0.05) higher CIE $b^*$ value than the other treatments. In results of nitroso pigment, T5 of smoked duck breast was significantly (p<0.05) higher value compared to other treatments, whereas T3 and T5 of smoked duck thigh had a significantly (p<0.05) higher value than other treatments. Heme pigment contents of control and T5 was significantly (p<0.05) higher value compared to other treatments in smoked duck breast. Meat color of T3 by sensory evaluation showed redder (p<0.05) than other treatments. These results suggested that using L-ascorbic acid is revealed to be pink color without nitrite or pigment when manufacturing of smoked duck meat.

The attrition pattern in Angle Class III malocclusion with facial astmmetry (안면비대칭을 동반한 Angle III급 부정교합자의 교모양상)

  • Son, Woo-Sung;Jeon, Eun-Ye;Kim, Sung-Jo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.549-557
    • /
    • 1997
  • This study was designed to investigate the attrition pattern in Angle Class III malocclusion with facial asymmetry. The sample consisted of three groups, the 20 subjects of normal occlusion group(Group I), the 12 subjects of class III malocclusion without facial asymmetry group(Group II) and 17 subjects of Class III malocclusion with facial asymmetry group(Group III). Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date processing. Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date Processing. All attrition areas were measured 2 times and the average value was used for data processing The data were statistically analyzed by SAS program. The results of this study were as follows. 1. Total attrition area in Group I was larger than in Group II and III. 2. There was no significant difference in attrition area between right and left side in each group, but attrition area in Group III was larger than in Group I and II. 3. In Group I, Maxillary attrition area was larger than mandibular attrition area, but in Group ll and III, there was no significant difference in attrition area between maxilla and mandible. 4. In Group III, the attrition area of deviated side was target than undeviated side 5. There was no significant difference in attrition area between chewing side and non-chewing side in each group. 6. The total attrition area was unaffected by gender.

  • PDF