• Title/Summary/Keyword: 힘 측정

Search Result 566, Processing Time 0.031 seconds

The Effects of Practical Reasoning Home Economics Instruction on Middle School Students' Self-Esteem (실천적 추론 수업이 중학생의 자아존중감에 미치는 효과)

  • Yoo Tae-Myung;Chae Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.1 s.39
    • /
    • pp.31-47
    • /
    • 2006
  • This study developed practical reasoning teaching-learning material for middle school home economics education and tested its effects on middle school students' self-esteem The type of this study was a quasi-experimental research and its independent variable was practical reasoning instruction and its dependent variable was self-esteem. The research design for this study was a pretest-posttest design. Practical reasoning instruction was given for experimental group whereas traditional instruction was given to comparison group. For measuring self-esteem, 'self-esteem scale' developed by Choi & Jun(1993) was used and its Cronbach'a was ranged from .69 to .84. Statistic analysis was done by mean and standard deviation for general characteristics of samples and paired t-test for testing difference of pretest-posttest. The results of this study showed that practical reasoning instruction improved middles school students' self-esteem, the general self-esteem and social self-esteem among sub-areas of self-esteem in particular.

  • PDF

Controlled Release of Nifedipine from Osmotic Pellet Based on Porous Membrane (니페디핀을 포함한 삼투성펠렛의 제조와 다공성막을 통한 약물방출제어)

  • Youn, Ju-Yong;Ku, Jeong;Kim, Byung-Soo;Kim, Moon-Suk;Lee, Bong;Khang, Gil-Son;Lee, Hai-Bang
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.328-333
    • /
    • 2008
  • The osmotic delivery systems are based on osmosis. The transverse diffusion of water through a porous membrane from a medium with a low osmotic pressure to a medium with a high osmotic pressure. Nifedipine tablet dosage forms of Procardia $XL^{(R)}$(Pfizer) and $Adalat^{(R)}$(Bayer) are commercialized systems of this type that push-pull osmotic tablet operates successfully in delivering water-insoluble drugs. We prepared osmotic pellet system by fluidized bed coating method, and model-drug used nifedipine. The osmotic pellet system was composed of the core material. the swelling and osmotic pressure layer, the drug coating layer, and the porous membrane. This work is performed to investigate the effect of different factors, such as composition and thickness of membrane. The osmotic pellet has been successfully prepared by fluidized bed coating technology. The drug release behavior depended on the increase of CA ratio and thickness in porous membrane. The morphology of the osmotic pellet before and after the dissolution test were observed by SEM. In conclusion, we found that the drug release of osmotic pellet depended on the composition and coating thickness of porous membrane.

Histologic and biomechanical characteristics of orthodontic self-drilling and self-tapping microscrew implants (Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교)

  • Park, Hyo-Sang;Yen, Shue;Jeoung, Seong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.295-307
    • /
    • 2006
  • Objective: The purpose of this study was to compare the histological and biomechanical characteristics of self-tapping and self-drilling microscrew implants. Methods: 112 microscrew implants (56 self-drilling and 56 self-tapping) were placed into the tibia of 28 rabbits. The implants were loaded immediately with no force, light (100 gm), or heavy force (200 gm) with nickel-titanium coil springs. The animals were sacrificed at 3- and 5-weeks after placement and histologic and histomorphometric analysis were performed under a microscope. Results: All microscrew implants stayed firm throughout the experiment. There was no significant difference between self-drilling and self-tapping microscrew implants both in peak insertion and removal torques. Histologic examinations showed there were more defects in the self-tapping than the self-drilling microscrew implants, and newly formed immature bone was increased at the interface in the self-tapping 5-week group. There was proliferation of bone towards the outer surface of the implant and/or toward the marrow space in the self-drilling group. Histologically, self-drilling microscrew implants provided more bone contact initially but the two methods became similar at 5 weeks. Conclusion: These results indicate the two methods can be used for microscrew implant placement, but when using self-tapping microscrew implants, it seems better to use light force in the early stages.

Design of a Hydraulic Circuit for a Front Axle Suspension of an Agricultural Tractor via Hydraulic Simulation (유압 시뮬레이션을 이용한 트랙터 전방차축 현가장치 유압회로 설계)

  • Cho, Bong-Jin;Kim, Hak-Jin;Lee, Chang-Joo;Choi, Jin-Ha;Kim, Young-Joo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.6-6
    • /
    • 2017
  • 농용트랙터의 전방차축 현가장치는 노면으로부터 발생하는 진동의 영향을 줄일 수 있기 때문에 트랙터의 대형화, 고속화의 추세에 맞춰서 승차감과 조향감을 향상시키는 데 중요한 역할을 한다. 전방차축의 현가장치는 트랙터의 차체 무게에 의한 부하가 크고, 또한 유압 펌프를 비롯한 유압시스템이 존재하기 때문에 유압식 회로로 구성하는 것이 바람직하다. 하지만, 현가장치의 유압회로를 개발하는데 있어서 실제 시스템을 구성하여 실제 실험을 통한 개발에는 비용과 시간이 많이 필요하다. 본 연구에서는 유압식 전방차축 현가장치에 필요한 유압회로부 개발을 위하여 시뮬레이션 기법과 요인시험 장치를 이용 적정 유압회로를 설계하고자 하였다. 이를 위하여 어큐뮬레이터, 가변 오리피스, 릴리프밸브, 체크밸브 등으로 구성된 유압 현가요인 시험 장치를 설계 제작하였으며, 현가 부품인 실린더 행정, 속도, 전달되는 힘을 측정하고, 유압 해석 프로그램인 SimulationX를 이용 구성된 유압회로 부품에 측정값을 입력하여 실제 조건과 유사한 동특성을 나타내는 전방차축 현가요인 시뮬레이션 모델을 개발하였다. 개발된 시뮬레이션 모델을 이용하여 실제 시험조건과 같은 가진 조건을 부여하여 개발 현가장치의 특성 값 변동에 따른 현가 성능을 구명하였다. 이를 위해 시뮬레이션 상에서 120 마력 트랙터 무게의 50% 수준에 해당하는 2,000 kg의 부하가 존재하는 상태에서 현가장치의 유/무에 따른, 감쇠 계수의 변화에 따른 스프링상 질량의 RMS 가속도를 비교하였다. 입력 가진으로는 1 Hz, 4 Hz, 8 Hz의 진동수에 각각 10 mm, 6.4 mm, 3.2 mm의 진폭을 인가하였다. 시뮬레이션 결과, 1 Hz에서는 현가장치가 있는 경우 최대 55.9% 개선되었고, 4 Hz에서는 최대 3.9 % 개선되었고, 8 Hz에서는 최대 61.4%까지 개선되었다. 이는 4 Hz의 경우에는 2,000 kg의 부하에 해당하는 고유 진동수 대역에 해당하기 때문에 그 감쇠 효과가 없는 것으로 나타났다. 하지만, 다른 주파수 대역에서는 현가장치가 효과적으로 작동하는 것을 나타내었다. 설계한 전방차축 현가 유압회로부를 시뮬레이션을 통하여 분석한 결과, RMS 가속도의 개선이 명확하게 이루어지는 것을 확인하였으며 입력 주파수 변화에 따라 감쇠특성도 나타나는 것을 확인하였다. 추후 연구에는 설계한 유압회로부와 관련 부품을 설계 제작하여 실제 트랙터에 장착 그 성능을 검증할 예정이며, 노면조건에 따라 감쇠성능을 유지하기 위한 반능동형 또는 적응형 현가장치 제어 기술을 적용하여 개선된 현가성능을 확보하기 위한 연구를 수행할 예정이다.

  • PDF

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

Analysis of Capillary Flow in Open-Top Rectangular Microchannel (상판이 없는 직사각형 단면의 미세채널에서 모세관 유동 분석)

  • Park, Eun-Jung;Cho, Ji-Yong;Kim, Jeong-Chul;Hur, Dae-Sung;Chung, Chan-Il;Kim, Jung-Kyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.77-82
    • /
    • 2010
  • Our study aims to understand the flow of liquid in an open-top rectangular microchannel that can be used in micro total analysis systems ($\mu$-TAS) because it has advantages in terms of light transmission and energy efficiency. We measured the liquid velocity using particle tracking technique and conducted a simulation with computational fluid dynamics by altering the area of channel cross section and channel length for the capillary-driven flow in the open-top rectangular microchannel. When liquid water drops to an entrance of the fabricated microchannel with a height of 20 μm and a width of 20 ${\mu}m$, it flows along the microchannel by only capillary force. In the wetting behavior of the liquid, important parameters of this flow are channel size, contact angle and liquid properties such as surface tension and viscosity, which are used to control the flow of liquid in the microchannel.

A Study on User-Centric Force-Touch Measurement using Force-Touch Cover (포스 터치 커버를 이용한 사용자 중심적 포스 터치 측정에 관한 연구)

  • Nam, ChoonSung;Suh, Min-soo;Shin, DongRyeol
    • Journal of Internet Computing and Services
    • /
    • v.18 no.3
    • /
    • pp.37-48
    • /
    • 2017
  • Touch interface has been introduced as one of the most common input devices that are widely used in the Smart Device. Recently Force-Touch interface, a new approach of input method, having the power recognition mechanism, has been appeared in Smart industries. Force-Touching determining multiple things (the geographical and pressure values of touching point) in one touching act allows users to provide more than one input methods in a limited environments. Force-Touching Device is required different user communicational interaction than other common Smart devices because it is possible to recognize various inputs in the one act. It means that Force-Touching is only able to understand and to use the pressure sensitive values, not other Smart input methods. So, we built Force-Touch-Cover that makes typical Smart-Device to have Force-Touching interfaces. We analysis the accuracy of the Force-Touching-Cover's sensor and also assessment the changes in pressure values depending on the pressure position. Via this Paper, We propose the implement of user-oriented Force-Touching interface that is based on users' feedback as our conclusion.

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF

Nanocrystalline Si formation inside SiNx nanostructures usingionized N2 gas bombardment (이온화 N2 가스 입사를 이용한 SiNx 나노구조 내부의 Si 나노결정 형성)

  • Jung, Min-Cherl;Park, Young-Ju;Shin, Hyun-Joon;Byun, Jun-Seok;Yoon, Jae-Jin;Park, Yong-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.474-478
    • /
    • 2007
  • Nanostructures of $SiN_x$ were made by bombardment of ionized $N_2$ on Si surface and subsequent annealing. Atomic force micrograph showed the density of $SiN_x$ nanostructures was $3\times10^{10}/cm^2$. Their lateral size and height were 40$\sim$60 nm and 15 nm, respectively. The chemical state of the nanostructure was measured using X-ray photoelectron spectroscopy, which changed from $SiN_x$ to $Si_3N_4\;+\;SiN_x$ as the bombarding ionized gas current increases. Upon annealing, transmission electron micrograph showed a clear evidence for crystalline Si phase formation inside the $SiN_x$ nanostructures. Photoluminescence peak observed at around 400nm was thought to be originated from the interface states between the nanocrystalline Si and surrounding $SiN_x$ nanostructures.

Changes in Textural Properties of Korean Radish and relevant Chemical, Enzymatic Activities during Salting (염장과정 중 무의 조직감과 이와 관련된 화학적, 효소활성 변화)

  • Rhee, Hee-Seoup;Lee, Gui-Ju
    • Journal of the Korean Society of Food Culture
    • /
    • v.8 no.3
    • /
    • pp.267-274
    • /
    • 1993
  • This study was aimed to investigate the changes in textural properties of Korean radish and relevant chemical, enzymatic activities during salting. During salting, pH was decreased and total acidity was increased. The maximum compression and puncture forces of Korean radish were decreased significantly whereas cutting force was increased. From the force-distance curves, the break point and maximum force point disappeared in salted Korean radish whereas these appeared apparently in fresh one. Also, the number of peak obtained by three types of test from salted Korean radish was decreased. Hot water soluble pectin and 0.4% Na-hexametaphosphate soluble pectin were increased whereas 0.05 N-HCl soluble pectin were decreased significantly. Polygalacturonase activity were increased in Korean radish solid(RS) and Korean radish juice(RJ) until 4 days of salting. Pectin esterase activity were decreased in RS and RJ. Cx-cellulase activity did not appear initially, however, they began to show their activities after 2 days of salting and were increased in RJ although it was low.

  • PDF