• Title/Summary/Keyword: 흡열효과

Search Result 44, Processing Time 0.026 seconds

Thermal Characteristics of the Garment Air-layers by PCM Concentration Changes (상변화물질 농도변화에 따른 의복내 공기층의 열적 특성)

  • Yoo, Hwa-Sook;Lim, Ji-Hye;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.6
    • /
    • pp.991-998
    • /
    • 2008
  • This study is to determine the effects of PCM concentration on the temperature changes of the air layers of a garment when the environmental temperature changes. The selected PCM was Nonadecane and coated on cotton fabrics with PCM concentrations 10%, 20%, and 30%. The temperature changes of the air layers between fabrics were measured by Human-Clothing-Environment Simulator which measure a dynamic heat transfer. After stabilizing at $34^{\circ}C$ for 1 hour, the multi layered garment system were exposed to $5^{\circ}C$ or $10^{\circ}C$ for 30 minutes and then, exposed to $34^{\circ}C$ for 30minutes. The results like following could be obtained. When the environmental temperature changed high to low, temperature of the air layer increased by heating effect of PCM. In the contrast, when the environmental temperature changed low to high, the temperature increase of the air layer was delayed because of cooling effect by PCM. Also, the more concentration of PCM, the bigger the heating effect. Cooling effect showed more clearly at PCM concentration 20%. The temperature differences of the air layers between with PCM fabrics and with non-PCM fabrics were bigger at $10^{\circ}C$ than at $5^{\circ}C$. Consequently, though PCM has influenced on the temperature of the air layer by heating and cooling effect, those effects haven't shown in all layers equally. It was shown that the effect of PCM varied according to the layer in the case of multi layered garment system and heat gain as well as heat loss in the outermost layer had to be taken into account.

Endothermic Properties of Liquid Fuel Decomposition Catalyst Using Metal Foam Support (메탈폼 지지체를 이용한 액체연료 분해반응 촉매의 흡열특성)

  • Mun, Jeongin;Kim, Nari;Jeong, Byunghun;Jung, Jihoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.481-486
    • /
    • 2021
  • In a hypersonic vehicle to solve the heat problem generated during flight, a cooling technology is being developed which uses the endothermic effect that appears during the decomposition reaction of the mounted fuel. In this study, the decomposition reaction of n-dodecane fuel was performed using HZSM-5 as a catalyst, and the catalyst was coated on metal foam to maximize the endothermic effect of the catalytic decomposition reaction and suppress coke formation. The reactor was a stainless steel flow reactor with a outer diameter of 1.27 cm, and the reaction temperature was 550 ℃, the reaction pressure was 4 MPa, and the flow rate was 12 ml per minute. As a result of the catalytic decomposition reaction using a catalyst coated with HZSM-5 on the metal foam, the heat sink was 2887 kJ/kg as a maximum, the gas phase conversion rate was 34%, and the amount of coke produced on the metal foam decreased by about 56% as the catalyst was coated compared to the uncoated catalyst.

Study on Solar Air Collector with Perforated Endothermic Panel(Experimental and Numerical Study) (흡열다공판을 이용한 공기식 태양열 집열 유닛에 관한 연구(실험 및 수치해석적 연구))

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.732-739
    • /
    • 2011
  • In recent years, the crisis of energy is growing seriously and also the contamination of ecology has been reverberated as international problem. The social concerns on energy crisis have been growing for the last several years and also the interests in new and renewable energy have been increased. Therefore, in order to solving these problems, this study has dealt with the solar air collector with perforated endothermic panel to increase the indoor temperature. And also, the PV panel for running indoor air circulating fan has used to increase the convective heat transfer. This study is consisted with experiment and numerical parts. From this study, the experimently result is indicated that the inlet air temperature is increased up to 45[$^{\circ}C$]. This temperature is enough to heat the indoor air during winter season. And the numerical calculation results revealed that the mixing effect of convection is increased with increasing in fan circulating power.

Chemical Fixation of Carbon Dioxide with Methane (메탄에 의한 이산화탄소의 화학적 고정화)

  • 조영복;김상채;서성규;유의연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.389-390
    • /
    • 2000
  • 최근 지구 온난화의 55% 이상을 차지하고 있는 이산화탄소를 유용한 화합물로 전환하고자 메탄을 환원제로 사용한 이산화탄소 개질반응으로부터 합성가스 생성에 관한 연구가 활발히 진행되고 있다. 메탄의 이산화탄소 개질반응은 수증기 개질반응보다 낮은 합성 가스비의 생성, 온실효과를 유발하는 이산화탄소의 저감, 반응의 높은 흡열도를 이용한 화학에너지 전송 시스템의 응용 면에서 그 의의가 있다. (중략)

  • PDF

Characteristics of Heat Absorption by Gas in a Directly-irradiated Fluidized Bed Particle Receiver (태양열 유동층 흡열기의 기체 열흡수 특성)

  • Park, Sae Han;Kim, Sung Won
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.239-246
    • /
    • 2021
  • Characteristics of hydrodynamics and heat absorption by gas in a directly-irradiated fluidized bed particle receiver (50 mm-ID X 150 mm high) of SiC particles have been determined. Solid holdups of SiC particles show almost constant values with increasing gas velocity. Fine SiC particles (SiC II; dp=52 ㎛, ρs=2992 kg/㎥) showed low values of relative standard deviation of pressure drop across bed but high solids holdups in the freeboard region compared to coarse SiC particles (SiC I; dp=123 ㎛, ρs=3015 kg/㎥). The SiC II exhibited higher values of temperature difference normalized by irradiance due to the effect of additional solar heat absorption and heat transfer to the gas by the particles entrained in the freeboard region in addition to the efficient thermal diffusion of the solar heat received at bed surface. Heat absorption rate and efficiency increased with increasing the gas velocity and fluidization number. The SiC II showed maximum heat absorption rate of 17.8 W and thermal efficiency of 14.8%, which are about 33% higher than those of SiC I within the experimental gas velocity range.

Study of Heating Temperature and Quantification Conditions of Standard Water for Evaluating Hair Water Content (모발 수분 함량 평가를 위한 가열 온도와 기준 수분 정량 조건 연구)

  • Sang-Hun Song;Jangho Joo;Hyun Sub Park;Seong Kil Son;Nae-Gyu Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.50 no.1
    • /
    • pp.11-18
    • /
    • 2024
  • Recently, there have been attempts to claim the hair moisturizing effect for a hair care product, however there has not yet been an official evaluation method because heating temperature for hair has not been established. This study was conducted to establish a quantitative evaluation for hair water content. In order to observe the behavior of water inside hair, heat was applied to hair with various temperatures using thermogravimetric dry residue. As the heating temperature increased, the amount of moisture released from the hair increased. As a result of evaluating hair using a differential scanning calorimeter (DSC), a unique phenomenon in which a rapid endothermic reaction occurs around 75 ℃ was observed. This phenomenon was also observed in different ethnic hair. In hair that damaged the hair cuticle barrier with oxidation and heat, this rapidly rising endothermic reaction temperature occurred at 77 ℃, which was slightly higher, and 73 ℃ was observed when this hair was applied with polar oil, conditioning polymer, or keratin protein. To determine how this reaction affects the hair surface, friction test was performed using an atomic force microscope. When heated above 75 ℃, cuticle friction increased, however when heated above 90 ℃, there was no change in hair cuticle friction. Finally, it was confirmed that around 75 ℃ is the critical temperature at which desorption of water bound to the hair occurs. It is suggested that a heating temperature of 75 ℃ is the optimal temperature for detecting and quantifying the moisture content of hair, and that approximately 10% detected at 75 ℃ can be a standard value for hair moisture content.

A study of geothermal heat dump for solar collectors overheat protection (태양열 집열관 과열방지를 위한 지중열교환기 연구)

  • Hwang, Hyun-Chang;Chi, Ri-Guang;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.616-622
    • /
    • 2016
  • The heating load using solar hot water is lower in summer than in the other seasons. This decreased heating load leads to the overheating solar collectors and related components. To prevent overheating of the solar collectors, air cooling and shading shields were used. On the other hand, it requires additional mechanical components, and reduces the system reliability. The geothermal heat dump system to release the high temperature heat (over $150^{\circ}C$) transferred from the heat pipe solar collectors was investigated in the present study. Research on the heat dump to cool the solar collector is rare. Therefore, the present study was carried out to collect possible data of a geothermal heat dump to cool the solar collector. A helical type geothermal heat exchanger was buried at a 1.2m depth. Experimentally and numerically, the geothermal heat dump was investigated in terms of the effects of parameters, such as the quantity of solar radiation, aperture area of the collector and the mass flow rate. A pipe length of 50m on the geothermal heat exchanger was suitable with a 0.33 kg/s flow rate. The water reservoir was a possible co-operation solution linked to the geothermal heat exchanger.

Effect of Amylose Content on the Physical Properties of Resistant Starches (효소저항전분의 물리적 성질에 대한 아밀로오스 함량의 효과)

  • Mun, Sae-Hun;Baik, Moo-Yeol;Shin, Mal-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.516-521
    • /
    • 1997
  • Effect of amylose content on the physical properties of resistant starches (RS) from autoclaved maize starches (with starch:water=1:3.5, at $121^{\circ}C$) which were repeated up to 4 times heating-cooling cycles, were investigated by water uptake, scanning electron microscope (SEM) and differential scanning calorimetry (DSC). Amylose content of waxy maize starch (Amioca), common maize starch (PFP), high amylose starch(Amaizo, Amylomaize VII) were 0%, 29%, 50%, and 72%, respectively. Yield of RS increased as amylose content increased. Water uptake of all kinds of native starch was higher than that of RS, but lower than that of autoclaved starch. By SEM, RS showed some small particles on surface but the size of particles was different with amylose content. Single endothermic transition peak exhibited at $40{\sim}70^{\circ}C$ in autoclaved Amioca and PFP (crystalline melting of amylopectin) and at $132{\sim}169^{\circ}C$ in autoclaved Amaizo and Amylomaize VII(crystalline melting of amylose) by DSC. RS from all kinds of autoclaved starches except Amioca showed single endothermic peak over $155^{\circ}C$ but the enthalpy was not related to amylose content.

  • PDF

Effect of Artificial Granular Zeolite(AGZ) on Purification of Heavy Metals in Wastewater and Alleviation or Rice Seeding Growth Damage (입상 인공제올라이트를 이용한 중금속 폐수 정화와 벼 유묘 생육장해 경감)

  • Lee, Deog-Bae;Lee, Kyeong-Bo;Lee, Sang-Bok;Kim, Jae-Duk;Henmi, Teruo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.446-451
    • /
    • 1999
  • This study was carried out to investigate some mineralogical characteristics of Artificial Granular Zeolite (AGZ) and effect of AGZ on purification and alleviation of rice seedling damages of mine wastewater containing heavy metals. AGZ had mainly representative Na-P1 peaks and some $C_3S$ peaks of Portland cement in X-ray diffractogram. Differential thermal analysis represented that AGZ had weak endothermic peak around $130^{\circ}C$ and new deep endothermic peak around $750^{\circ}C$ as compared to powdery artificial zeolite. The ranking of heavy metals removals by AGZ, was lead> copper> cadmium> zinc in the synthetic wastewater. Root growth of rice seedling was greatly inhibited in the mine wastewater, and died after all. As AGZ treated into the mine wastewater with the ratio 1 : 50 (W : V) for one day or 1 : 100 for 4 days, the concentrations of heavy metals in the mine wastewater were decreased to below the critical concentration for agricultural use. And rice seedlings were grew with little damages in the purified water by AGZ.

  • PDF

Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element (열전소자를 이용한 배수형 전자제습기 개발)

  • Kang, Deok-Hong;Kim, Seong-Hwan;Kim, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF