• Title/Summary/Keyword: 흡수 능력

Search Result 542, Processing Time 0.026 seconds

A experimental study of water vapor absorption characteristics using four components solution for gas fired absorption chiller (가스냉난방기용 4성분계 흡수용액의 수증기 흡수특성에 관한 실험적 연구)

  • Lee Yong-Won;Oh Young-Sam;Park Dal-Ryung;Baek Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.47-52
    • /
    • 1998
  • Water vapor absorption performance of four components solution ($LiBr+LiNO_3+LiC1+H_2O$) which could be substituted for commonly used $LiBr/H_2O$ solution in water cooled abosorption chiller is tested using a vertical tube absorber. Inlet solution concentration, inlet solution temperature, solution flow rate and inlet temperature of cooling water is varied as experimental parameters. The results of the experiment of water vapor absorption performance show that four components solution should have $2\%$ higher concentration for equal absorption capacity of $LiBr/H_2O$. But considering that four components solution have higher solubility than LiBr solution about $3\%$ high oncentration, four components solution ($LiBr+LiNO_3+LiC1+H_2O$) have more absorption capacity than LiBr solution in actual absorption chiller and can be applied to a small or air cooled absorption chiller.

  • PDF

Estimation of Absorbing Capacity from Rockfall Protection Fences (도로 낙석방지울타리의 낙석지지능력 평가 연구)

  • Hwang, Young-Cheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.59-66
    • /
    • 2002
  • Designs for rockfall protection systems must consider rock and soil types, the angle of the slope, conditions on top and the toe of the affected area. Rockfall protection fence is installed to block for falling rock from cut slopes and this is one of the most common rockfall protection measures. The capability of the fence is provided that sum of capability of poly vinyl chloride coated wire mesh, steel support and wire rope respectively. But in some case, the rockfall protection fence was not supported rockfall energy less than total capability of the fence through the full scale rockfall tests. Therefore, the objectives of this paper are to indicate the problems of fence capability and to improve the design specifications for the fence.

  • PDF

Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber) (수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)))

  • Ohm, K.C.;Kashiwagi, Takao;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

Operating Characteristics of Ammonia-Water Absorber Heat Exchange Cycle (암모니아-물 흡수식 열교환 사이클의 운전 특성)

  • 강인석;김남진;김종보
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.357-362
    • /
    • 2001
  • A bench type ammonia-water absorber heat exchange cycle was tested by varying the system charging concentration, refrigerating valve opening and weak solution flow rate. It was observed that the cooling capacity was increased as the system charging concentration was increased. Optimum system charging concentration was found for the coolong capacity of the system. The opening rate of refrigerant expansion valve had a direct influence on the refrigerant sub-cooling at the condenser outlet. Optimum sub-cooling was found to be 0~4$^{\circ}C$. As the weak solution flow rate increased the concentration of strong solution and the evaporating pressure decreased. There existed a optimum weak solution flow rate which maximized the cooling capacity and COP.

  • PDF

안트라싸이클린계 항암.항생제의 유사제제의 합성에 관한 연구

  • 장영동
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.119-119
    • /
    • 1993
  • 안트라싸이클린계 항암항생제의 부작용 발생기전으로는 C-고리의 퀴논 부위에 전자가 전달되어 퀴논 고리가 환원되는 과정이 제시되고 있으며 그 중 하나의 전자가 전달되어 생성되는 활성산소(activated oxygen)가 심장독성과 관련이 있는 것으로 알려져 있다. 이 때 퀴논 고리의 환원력(전자흡수능력)이 C-고리자체의 변환, 또는 인접 B-고리에 도입된 치환체의 영향으로 억제될 수 있다는 보고를 이론적 근거로 하여 안트라싸이클리논 골격을 전자흡수 능력을 가진 acridone 골격으로 치환한 화합물(1)과 안트라싸이클리논 골격을 유지하면서 aminosugar 부위를 pentopyranose계열을 도입 한 2 합성하였다. 화합물 1은 1,3-butadiene 과 1,4-benzoquinone 의 Diels-Alder adduct 3을 출발물질로 하여 7 단계의 반응과정으로 합성하였다.

  • PDF

Effect of Absorbent Materials and Initial Sealed Curing on Drying Shrinkage and Compressive Strength of Hwangtoh Mortar (흡수성 물질과 초기 밀봉양생이 황토 모르타르의 건조수축과 압축강도에 미치는 영향)

  • Kwon, Yang-Hee;Hong, Sung-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.6
    • /
    • pp.20-29
    • /
    • 2016
  • This study investigates the effect of the absorbent materials on the material properties(compressive strength and drying shrinkage) of natural hwangtoh mortar which is one of the traditional building material in Korea. The absorbent materials used are seaweed paste and Super-Absorbent Polymer(SAP). In addition to the absorbent materials, the initial sealed curing recommended by the standard specification of properties for Korean traditional building materials is also a main interest of this study. Based on the test results of 28 days compressive strength and converged drying shrinkage, it is confirmed that the initial sealed curing for 7 days is effective to reduce the drying shrinkage and to enhance the compressive strength. Thus, it is verified that the recommendation is reasonable and has positive effects on the properties of the mortar. Next, the test results show that the addition of absorbent materials into the mortar is also effective to the two properties depending on their absorption capacity. Thus, it is more effective to use SAP than the seaweed paste because of higher absorption capacity. However, both the initial sealed curing and keeping total water contents of the mortar are required to show this effectiveness. Lastly, the compressive strength is inversely proportional to the drying shrinkage. By using this relation, the reason of the increase of compressive strength due to the initial sealed curing or the addition of absorbent materials is quantitatively explained.

A Study on the Acoustic Damping Characteristics of Acoustic Cavities in a Liquid Rocket Engine (로켓엔진에서 음향공의 음향학적 감쇠능력에 대한 고찰)

  • Kim Hong Jip;Kim Seong-Ku;Choi Hwan Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.291-298
    • /
    • 2005
  • Linear acoustic analysis has been performed to elucidate damping characteristics of acoustic cavities. Results have shown that resonant frequencies of acoustic cavity obtained by classical theoretic approach and present linear analysis are somewhat different from each other. This difference is due to the limitation of classical theory. To quantify the damping characteristics, acoustic impedance has been introduced and resultant absorption and conductance have been evaluated. Satisfactory agreement has been achieved with previous experiment. Finally the design procedure for optimal tuning of acoustic cavity has been established

  • PDF

National R&D for the Development of Technological Capabilities in Developing Countries (개도국의 기술경쟁력 발전을 위한 국가 연구개발사업의 역할)

  • 이태준;양맹호
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2002.05b
    • /
    • pp.221-228
    • /
    • 2002
  • In viewing R&D as a series of activities of problem solving in the course of technological learning in developing countries, national R&D is very likely to play an pivotal role in incubating and improving industrial technology and competitiveness, especially for S&T-intensive industries, such as nuclear fuel industry. To this end, the national R&D needs to be primarily designed to reinforce technological capabilities of the country including government research institutes (GRIs), industrial firms, etc., from the initial stage of absorption as well as at the innovation stage. Based on this strategic role, national R&D performed by GRIs should provide scientific knowledge and core technologies which are required for the absorbption of foreign technology and development of indigenous technological capabilities with which domestic technological efforts are made to successfully achieve not only technological imitation but also innovation in global sense.

  • PDF

The Effect of Technology Start-up Companies' Absorption Capacity on Start-up Performance: Focusing on the Mediating Effect of Patent Activities (기술창업기업의 흡수역량이 창업성과에 미치는 영향: 특허활동의 매개효과를 중심으로)

  • Kim Jong Sik;Nam Jung Min
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.18 no.3
    • /
    • pp.191-209
    • /
    • 2023
  • Amid rapid changes in technological innovation due to the influence of the 4th Industrial Revolution and COVID-19, research related to absorption capacity and patent activities to promote technological innovation of Korean technology start-ups is important in this uncertain environment. This study aims to examine the effects on entrepreneurial performance and patent activities by reconstructing absorptive capacity, an organizational capability, for technology-based startups in fields such as BT and ICT with less than seven years of establishment, distinguishing between potential absorptive capacity and realized absorptive capacity. The study also seeks to develop a theoretical research model. To accomplish this, data was collected from managerial executives, including CEOs of 215 technology startups. The following hypotheses were tested: Firstly, potential absorptive capacity had a significant impact on patent activities, while realized absorptive capacity did not. Secondly, potential absorptive capacity had a significant impact on technological performance, while realized absorptive capacity did not. Thirdly, both potential and realized absorptive capacity had a significant impact on financial and non-financial performance. Fourthly, patent activities indirectly influenced potential absorptive capacity and technological performance, but did not affect realized absorptive capacity. Fifthly, patent activities indirectly influenced potential absorptive capacity and financial performance, but did not affect realized absorptive capacity. Lastly, patent activities indirectly influenced potential absorptive capacity and non-financial performance, but did not affect realized absorptive capacity. The practical significance of this study lies in providing useful guidelines for building the core capabilities of organizations through absorptive capacity and patent activities. Furthermore, it is expected that startups that have not recognized the formation process of absorptive capacity for patent activities will perceive the formation mechanism of absorptive capability anew and show considerable interest in future potential and realized absorptive capacity as part of their management strategies. This is anticipated to play an important role in adapting to rapidly changing technological advancements, the startup ecosystem, and securing sustainable competitive advantages.

  • PDF

Test of RC Structures with Friction Damper (마찰형 댐퍼가 있는 RC 구조물에 관한 실험적 연구)

  • Kim, Young Ju;Ahn, Tae Sang;Lee, Chang Hwan;Kim, Sang Dae
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • 국내의 내진설계 기준은 1988년에 처음 도입되었으며, 최근 점차 강화되고 있는 실정이다. 공동주택에 주로 적용되는 전단벽식 구조시스템에서 증가된 지진력에 저항하기 위해서는 벽량과 철근이 증가하게 되어 공사비가 상승하게 된다. 이러한 단점을 보완하기 위한 제진설계의 필요성이 대두되고 있는 실정인데, 기존의 제진장치는 주로 가새형 또는 벽체형을 대부분이라 평면계획에 제약이 있다. 따라서 전단벽식 구조의 공동주택의 제진설계 시에는 우리나라와 같은 중 약진 지역에 적합하고 저렴한 비용으로 충분한 내진성능과 평면의 가변성을 확보할 수 있는 댐퍼의 선택이 필요하다. 본 연구의 목적은 기존의 가새형 및 벽체형 제진장치의 국내 공동주택 적용시의 문제점인 평면의 가변성 확보에 유리하고, 수동형 제진장치의 장점을 추구할 수 있는 마찰댐퍼를 삽입한 커플링보 제진시스템의 내진성능을 조사하는 것이다. 내진성능을 평가하기 위해서 실대형 커플링보 실험체를 계획하고 제작하였다. 실험체는 2개로 구성되어 있으며, 하나는 기존의 철근배근 상세를 갖는 철근콘크리트 커플링보 실험체와 커플링보에 마찰댐퍼가 삽입된 실험체이다. 횡하중에 대한 성능을 평가하기 위해서 유사정적 반복가력실험을 실시하였다. 엑츄에이터로부터 실험체 상보의 가력지그를 통해 하중이 전달되도록 하였으며, 가력은 최초 0.25%의 층간변형각부터 변위제어를 통해 목표 층간변형각인 1.5% 이상까지 진행되도록 하였다. 실험결과, 두 실험체의 이력곡선과 에너지 흡수능력을 평가하였다. RC 실험체는 핀칭현상이 관찰되었고, 가력이 진행됨에 따라 커플링보와 벽체에서의 균열이 확산되어 종국적으로 취성적인 커플링보의 전단파괴가 발생하였다. 마찰댐퍼를 삽입한 실험체는 계획된 마찰거동이 잘 발휘되어 목표 층간변형각인 1.5%까지 이선형거동이 잘 나타났다. 최대 내력은 RC 실험체가 3배 이상 크지만, 누적층간변형각에 따른 에너지 흡수능력은 마찰댐퍼 실험체가 2배 이상 우수한 결과를 보였으며, 커플링보 및 벽체에서의 균열이 매우 저감되었다.

  • PDF