• 제목/요약/키워드: 흡수냉동

검색결과 153건 처리시간 0.024초

복합 열원 공조시스템의 최적 제어 알고리즘 (Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

흡수식을 이용한 에너지 장거리 수송/변환 기술

  • 강용태
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.11-18
    • /
    • 2004
  • 흡수식 사이클을 이용한 에너지의 장거리수송 기술을 소개하고 경제성평가 결과를 제시한다. 현재 에너지수요 측면에서 가장 높은 증가율을 보이고 있는 것이 바로 대도시 및 산업단지의 냉$.$난방 및 급탕용 에너지이다. 냉$.$난방에 사용되는 에너지는 10$0^{\circ}C$미만의 저온으로서 고열원 에너지인 화석연료의 사용은 에너지사용 면에서 비효율적이다. 따라서 산업지 역에서 버려지는 폐열원등의 각종 미활용에너지를 이용하여 냉$.$난방부하를 충족시킬 수 있는 에너지 절약형 시스템의 개발이 매우 중요한 과제로 대두되고 있다. 일반적으로 미활용에너지 및 폐열에너지 공급지역은 소비지역으로부터 멀리 떨어져 있다. 지금까지 흡수식시스템은 냉동 및 냉방의 개념에서 기술개발 및 실용적운전이 이루어져 왔으나, 본 논문에서는 흡수식시스템을 이용한 에너지의 장거리수송 및 변환 기술을 소개하고자 한다.

  • PDF

냉수 대온도차 흡수식 냉동기용 2단 증발기/ 흡수기 최적 설계 (Optimum design of the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;임익태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.203-211
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

흡수식 냉동시스템의 고장현상 분석과 진단 (Fault Symptom Analysis and Diagnosis for a Single-Effect Absorption Chiller)

  • 한동원;장영수;김용찬
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.587-595
    • /
    • 2015
  • In this study, fault symptoms were simulated and analyzed for a single-effect absorption chiller. The fault patterns of fault detection parameters were tabulated using the fault symptom simulation results. Fault detection and diagnosis by a process history-based method were performed for the in-situ experiment of a single-effect absorption chiller. Simulated fault modes for the in-situ experimental study are the decreases in cooling water and chilled water mass flow rates. Five no-fault reference models for fault detection of a single-effect absorption chiller were developed using fault-free steady-state data. A sensitivity analysis of fault detection using the normalized distance method was carried out with respect to fault progress. When mass flow rates of the cooling and chilled water decrease by more than 19.3% and 17.8%, respectively, the fault can be detected using the normalized distance method, and COP reductions are 6.8% and 4.7%, respectively, compared with normal operation performance. The pattern recognition method for fault diagnosis of a single-effect absorption chiller was found to indicate each failure mode accurately.

응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser)

  • 박찬우
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.