• Title/Summary/Keyword: 흉부 측면 방사선

Search Result 23, Processing Time 0.038 seconds

Evaluation of Respiration Reproducibility of Chest General X-ray Examination using Self-made Respiratory Synchronization Device (자체 제작한 호흡 동기화 장치를 통한 흉부 일반촬영 검사의 호흡 재현성 평가)

  • Kwon, Oh-Young;Lee, Chang-Hun;Yong, Keum-Ju;Jin, Seon-Hui;Jung, Da-Bin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1049-1056
    • /
    • 2021
  • The purpose of this study was to develop a respiratory synchronization device for X-ray (X-RSD) to increase the reproducibility of inspiration when examining the Chest X-ray of a patient who difficulty in breathing coordination. The X-RSD was self-made using an air pressure sensor and air was injected by connecting a ventilator to the mannequin for CPR. At this time, the amount of injected air was quantified using the SkillReporting device. After placing the X-RSD on the chest of the mannequin, the amount of air was tested in 6 steps from 200 to 700 cc by 100 cc increased. For the accuracy evaluation, the sensitivity of X-RSD was measured by repeating a total of 80 measurements, and the sensitivity was 100%, and very precise results were obtained. After that, the images examined while viewing the X-RSD of the chest lateral examination and the images obtained by the blind examination were compared and evaluated. The lung volume of X-RSD was larger than that of the blind test, and the deviation was smaller. Overall, the use of X-RSD can help with chest X-ray examination of patients who have difficulty in cooperating, and it is thought that it will be possible to contribute to the reduction of exposure dose by reducing the repeat rate of general X-ray examinations.

A comparative study of three therapeutic modalities in loculated tuberculous pleural effusions (소방이 형성된 결핵성 흉막 질환에서 배액 방법에 따른 치료효과)

  • Lee, Sang Hwa;Lee, So Ra;Lee, Sang Youb;Park, Sang Muyn;Suh, Jung Kyung;Cho, Jae Youn;Shim, Jae Jeong;In, Kwang Ho;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.683-692
    • /
    • 1996
  • Background: Although most of the patients with tuberculous pleural effusions completely reabsorbed their effusions and became asymptomatic within 2 to 4 months, later surgical procedures such as decortication is needed in some patients because of dyspnea caused by pleural loculations and thickening despite anti-tuberculous chemotherapy. It is obligatory to secure adequate drainage to prevent the development of complications. But, the best methods for treating loculated tuberculous pleural effusions remain debatable. Recent several reports revealed that intrapleural instillation of fibrinolytic agents is an effective adjunct in the management of complicated empyema and may reduce the need of surgery. Purpose : The effects of catheterization with intrapleural urokinase instillation were prospectively evaluated in the patients with septated tuberculous pleural effusion, and compared with other therapeutic effects of different modalities of therapy such as repeated thoracentesis and small-bored catheterization. Methods : Forty-eight patients diagnosed with tuberculous pleurisy were randomly separated into three groups; control group(n=13), catheter group(n=12), urokinase group(n=22). In urokinase group, dose of 100.000U urokinase was instilled into the pleural cavity via a percutaneous drainage catheter for complete drainage or total dose of 700,000U of urokinase. After two hours clamping, the catheter was opened and intermittently irrigated. The early and late effectiveness of therapies was assessed by radiographically and by measuring the volume of fluid drained from the catheter. Results : There was statistically significantly better result in the urokinase group in respect of frequency of catheterization, frequency of catheter obstruction and the duration of catheterization in early effectiveness(p < 0.05). There were no difference in radiologic improvement of follow-up in later phase chest X-ray between urokinase group and catheter group in later phase(p > 0.05). But there were more failure rates in control group especially honeycomb septa in pleural effusion sonographically than former two groups. And there were no complications of urokinase such as fever or hemorrhage. Conclusion : In the treatment of septated tuberculous pleurisy, there were better results in urokinase than those of catheterization alone in early effectiveness. And there was no difference in radiographic improvement between urokinase group and catheter group. Intrapleural instillation of urokinase is an effective and safe mode of treatment for septated tuberculous pleural effusions and alleviates the need for thoracotomy.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Screening test of commercial catalysts for direct synthesis of Dimethyl ether from syngas produced using coal and waste (석탄 및 폐기물로부터 생산된 합성가스로부터 Dimethyl ether의 직접합성을 위한 상용촉매 스크린테스트)

  • Kim, Eun-Jin;Han, Gi-Bo;Park, No-Kuk;Ryu, Si-Ok;Lee, Tae-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.689-692
    • /
    • 2005
  • 2020년까지 전 세계 수송에너지의 수요가 현재의 2배까지 증가할 것으로 예상되면서 석유 자원의 안정적 공급이 어려워지기 이전에 이를 대체할 수 있는 에너지원 개발이 시급하다. 이러한 노력의 일환으로 최근 들어 대두되고 있는 가스화용융 기술은 석탄 폐기물 등으로부터 합성가스를 생산하는 고청정 고효율 기술이다. 여기에서 생산되는 합성가스는 천연가스를 대체하여 전기 및 화학원료를 생산하기 위한 원료로 이용 가능하다. 폐기물로부터 가스화용융기술을 통하여 생산되는 합성가스로부터 DME(dimethyl ether)를 생산할 수 있다. 가스화용융기술로부터 생산되는 합성가스는 자체의 일산화탄소와 수소의 조성비가 DME를 합성하는데 적당하다고 알려져 있다. DME는 에너지원의 다원화와 대기오염 물질의 저감, 지구온난화 대응 등과 아울러 제 4세대 수송 연료로 부각되고 있다. DME를 합성하는 방법은 합성가스로부터 메탄올의 합성 단계를 거친 후 DME를 합성하는 간접법과 단일단계의 반응에서 합성가스로부터 직접적으로 DME를 합성하는 직접법이 있다. 현재는 화학 평형적 측면 경제적 측면에서 이점을 가지고 있는 직접법에 관한 연구가 활발히 이루어지고 있다. DME 직접합성법에서는 메탄올 합성 촉매와 메탄올 탈수촉매의 물리적 혼합에 의한 혼성촉매가 주로 이용되고 있는 것으로 알려져 있다 본 연구에서는 일산화탄소와 수소로 이루어진 합성 가스로부터 직접 DME를 생산할 수 있는 직접 합성 공정에 적용 가능한 고효율 촉매 기술을 개발하기 위해 상용촉매의 스크린 테스트를 수행하였다. 상용촉매로는 sud-chemi사에서 메탄을 합성 촉매와 탈수촉매를 각각 구입하였으며, 이들 촉매를 원하는 조성비로 물리적으로 혼합한 다음 반응온도 ($250-290^{\circ}C$) 압력 (30-50 atm), $H_2$/CO 몰비 (0.5-2.0) 등의 다양한 반응조건 하에서 스크린 테스트를 수행하였다.대장조영영상을 얻을 수 있어 대장암의 위치에 관한 정보를 삼차원적으로 제공하므로 대장암의 성상을 정확히 알 수 있는데 도움을 주었다.요인은 없는 것으로 사료된다. 이 중 2예의 CT에서 선상 혹은망상형의 음영을 보였다. 결론: 유방암 환자의 방사선 치료 후 CT 소견은 방사선 치료의 방법에 따라 폐첨부 혹은 폐의전면 흉막하 부위에 선상 혹은 망상형의 음영으로서 방사선 폐렴 혹은 섬유화 소견이다. CT는 단순 흉부 촬영보다 이상 소견의 발견이 쉽다.이러한 소견은 후에 합병될 수 있는 다른 폐질환의 감별 진단에 도움이 될 것으로 보인다.moembolization via the radial artery approach were involved in this study. All underwent Allen’s test to check ulnar arterial patency. In all cases, we used the radial approach hepatic artery (RHA) catheter designed by ourselves, evaluating t\ulcorner selec\ulcorneron ability of the hepatic artery using an RHA cathter, the number of punctures, the procedure time, and compression time at the puncture site as well as complications occurring during and after the procedure. Results: Except for three in which puncture failure, brachial artery variation or hepatic artery variation occurred, all procedures were successful. The mean number of punctures was 3.5, and the

  • PDF

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Comparison of IMRT and VMAT Techniques in Spine Stereotactic Radiosurgery with International Spine Radiosurgery Consortium Consensus Guidelines (International Spine Radiosurgery Consortium Consensus Guidelines에 따른 Spine Stereotactic Radiosurgery에서 IMRT와 VMAT의 비교연구)

  • Oh, Se An;Kang, Min Kyu;Kim, Sung Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.145-153
    • /
    • 2013
  • Stereotactic body radiation therapy (SBRT) is increasingly used to treat spinal metastases. To achieve the highest steep dose gradients and conformal dose distributions of target tumors, intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) techniques are essential to spine radiosurgery. The purpose of the study was to qualitatively compare IMRT and VMAT techniques with International Spine Radiosurgery Consortium (ISRC) contoured consensus guidelines for target volume definition. Planning target volume (PTV) was categorized as TB, $T_{BPT}$ and $T_{ST}$ depending on sectors involved; $T_B$ (vertebral body only), $T_{BPT}$ (vertebral body+pedicle+transverse process), and $T_{ST}$ (spinous process+transverse process). Three patients treated for spinal tumor in the cervical, thoracic, and lumbar region were selected. Eacg tumor was contoured by the definition from the ISRC guideline. Maximum spinal cord dose were 12.46 Gy, 12.17 Gy and 11.36 Gy for $T_B$, $T_{BPT}$ and $T_{ST}$ sites, and 11.81 Gy, 12.19 Gy and 11.99 Gy for the IMRT, RA1 and RA2 techniques, respectively. Average fall-off dose distance from 90% to 50% isodose line for $T_B$, $T_{BPT}$, and $T_{ST}$ sites were 3.5 mm, 3.3 mm and 3.9 mm and 3.7 mm, 3.7 mm and 3.3 mm for the IMRT, RA1 and RA2 techniques, respectively. For the most complicated target $T_{BPT}$ sites in the cervical, thoracic and lumbar regions, the conformity index of the IMRT, RA1 and RA2 is 0.621, 0.761 and 0.817 and 0.755, 0.796 and 0.824 for rDHI. Both IMRT and VMAT techniques delivered high conformal dose distributions in spine stereotactic radiosurgery. However, if the target volume includes the vertebral body, pedicle, and transverse process, IMRT planning resulted in insufficient conformity index, compared to VMAT planning. Nevertheless, IMRT technique was more effective in reducing the maximum spinal cord dose compared to RA1 and RA2 techniques at most sites.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

Analyze Technologies and Trends in Commercialized Radiology Artificial Intelligence Medical Device (상용화된 영상의학 인공지능 의료기기의 기술 및 동향 분석)

  • Chang-Hwa Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.881-887
    • /
    • 2023
  • This study aims to analyze the development and current trends of AI-based medical imaging devices commercialized in South Korea. As of September 30, 2023, there were a total of 186 AI-based medical devices licensed, certified, and reported to the Korean Ministry of Food and Drug Safety, of which 138 were related to imaging. The study comprehensively examined the yearly approval trends, equipment types, application areas, and key functions from 2018 to 2023. The study found that the number of AI medical devices started from four products in 2018 and grew steadily until 2023, with a sharp increase after 2020. This can be attributed to the interaction between the advancement of AI technology and the increasing demand in the medical field. By equipment, AI medical devices were developed in the order of CT, X-ray, and MR, which reflects the characteristics and clinical importance of the images of each equipment. This study found that the development of AI medical devices for specific areas such as the thorax, cranial nerves, and musculoskeletal system is active, and the main functions are medical image analysis, detection and diagnosis assistance, and image transmission. These results suggest that AI's pattern recognition and data analysis capabilities are playing an important role in the medical imaging field. In addition, this study examined the number of Korean products that have received international certifications, particularly the US FDA and European CE. The results show that many products have been certified by both organizations, indicating that Korean AI medical devices are in line with international standards and are competitive in the global market. By analyzing the impact of AI technology on medical imaging and its potential for development, this study provides important implications for future research and development directions. However, challenges such as regulatory aspects, data quality and accessibility, and clinical validity are also pointed out, requiring continued research and improvement on these issues.

Financial Impact of Off-Pump Coronary Artery Bypass (체외순환 없이 시행하는 관상동맥우회술의 경제성 분석)

  • Lim, Cheong;Chang, Woo-Ik;Kim, Ki-Bong;Kim, Yoon
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.365-368
    • /
    • 2002
  • Background: Coronary artery bypass grafting(CABG) imposes large amount of medical costs, which are greatly affected by the surgical approach, quality of perioperative care and associated co-morbidities. Recently, off-pump CABG(OPCAB) has been introduced and performed with increasing frequency. To evaluate the efficacy of OPCAB in view of financial impact, we analyzed the costs and medical resources of OPCAB and compared with conventional CABG. Material and Method: From January 1998 to July 1999, 184 patients underwent CABG operation; 111 patients with OPCAB(group I) and 73 patients with conventional CABG(group II). We prospectively collected clinical data including risk factors and retrospectively reviewed the hospital resources. Result: Preoperative parameters including risk factors, postoperative mortality, morbidity and length of hospital stay were not different between the two groups, Duration of stay in the intensive care unit(ICU) (51.3 vs 128.3 hours, p<0.01) and ventilator, support time(14.9 vs 56.2 hours, p<0.01) were significantly shorter in the OPCAB group. Total hospital coats were 17,220,000 add 21,250,000(Korean Won) in group I and II, respectively(p<0.01). There were significant differences in operation fee, costs for operative materials, transfusion and diagnostic radiology between two groups. In group I, all the resources except diagnostic radiology were significantly decreased compared with group II. Conclusion: OPCAB has a beneficial effect on hospital charge and resource utilization. Shorter duration of the ICU stay and ventilatory support time may reduce the total hospital costs.