• Title/Summary/Keyword: 흉부촬영

Search Result 835, Processing Time 0.023 seconds

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination (흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구)

  • Kim, Young-Keun;Yang, Sook;Wang, Tae-uk;Kim, Eun-Hye
    • Journal of radiological science and technology
    • /
    • v.44 no.2
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

DENTAL TREATMENT OF A PATIENT WITH SWYER JAMES UNDER GENERAL ANESTHESIA: A CASE REPORT (Swyer James syndrome환아의 전신마취 하 치아우식 치료: 증례보고)

  • Sung, Young Jae;Song, Ji Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Shin, Teo Jeon
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.15 no.1
    • /
    • pp.60-64
    • /
    • 2019
  • Swyer-James syndrome (SJS), also known as Swyer-James-MacLeod syndrome and unilateral hyperlucent lung syndrome, is rare acquired pulmonary disorder develops secondary to infectious etiologies in early childhood. Viral respiratory infection such as adenoviruses or Mycoplasma pneumoniae in infancy or early childhood rarely cause Swyer-James syndrome. It is generally characterized on radiographs by a unilateral small lung with hyperlucency and air trapping on expiration. In many cases unaffected lung tissue functions normally, compensating for affected lung portion. Preoperative assessment is needed to determinate individual's pulmonary function. A 4-year-old boy with Swyer-James syndrome visited Seoul National University Dental Hospital Department of pediatric dentistry for caries treatment. Clinical and radiographic examinations revealed multiple carious lesions on deciduous teeth. Considering patient's underling disease, age, and level of cooperation, dental treatment under general anesthesia was scheduled. Dental treatment was done with composite resin and stainless-steel crown. Since ventilation of Swyer-James syndrome patients was diminished because of airway obstruction, close monitoring of ventilation is necessary during dental treatment. Considering pulmonary pathology, general anesthesia rather than sedation is recommended when special behavior management is required for dental treatment. Swyer-James syndrome patients can tolerate general anesthesia and surgery well, according to several reports.

Atypical Presentation of Chronic Granulomatous Disease in a Neonate with a Pulmonary Granuloma Mimicking a Tumor: A Case Report (신생아에서 종양으로 오인되는 폐 육아종의 비전형적인 소견을 보인 만성 육아종성 질환: 증례 보고)

  • Young Jin Yoo;Joo Sung Sun;Jang Hoon Lee;Hyun Joo Jung;Yeong Hwa Koh;Joonho Jung;Hyun Gi Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.990-995
    • /
    • 2020
  • Chronic granulomatous disease (CGD) is an uncommon primary immune deficiency caused by phagocytes defective in oxygen metabolite production. It results in recurrent bacterial or fungal infections. Herein, we present a case of CGD with a large pulmonary granuloma in a neonate and review the imaging findings. The patient was a 24-day-old neonate admitted to the hospital with fever. A round opacified lesion was identified on the chest radiograph. Subsequent CT and MRI revealed a round mass with heterogeneous enhancement in the right lower lobe. There were foci of diffusion restriction in the mass. Surgical biopsy of the mass revealed chronic granuloma. Finally, the neonate was diagnosed with CGD caused by mutation of the gp91phox gene. Herein, we present the clinical and imaging findings of this unusual case of CGD.

Immunoglobulin G4-Related Lung Disease Mimicking Lung Cancer: Two Case Reports (폐암으로 오인된 면역글로불린 G4 연관 폐 질환: 2예에 대한 증례 보고)

  • Dae Yun Park;Su Young Kim;Suk Hyun Bae;Ji Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1168-1174
    • /
    • 2022
  • Immunoglobulin G4 (IgG4)-related disease is a rare systemic fibroinflammatory condition characterized by elevated serum IgG4 levels and infiltration of IgG4-positive plasma cells in various organs. IgG4-related lung disease shows varied radiologic features on chest CT. Patients usually present with a solid nodule or mass mimicking lung cancer; therefore, distinguishing between IgG4-related disease and other conditions is often challenging. Additionally, co-existing radiologic findings of IgG4-related lung disease may mimic metastasis or lymphangitic carcinomatosis of the lung. We report two cases of histopathologically confirmed IgG4-related lung disease mimicking lung cancer. Chest CT revealed a solid nodule or mass with ancillary radiologic findings, which suggested lung cancer; therefore, IgG4-related lung disease was radiologically indistinguishable from lung cancer in both cases. Measurement of serum IgG4 levels and clinical evaluation to confirm involvement of various organs may be useful to establish the differential diagnosis. However, surgical biopsy evaluation is needed for confirmation.

Endovascular Repair of Acute Type B Aortic Dissection: The Early Results and Aortic Wall Changes (급성 B형 대동맥 박리의 혈관내 스텐트-그라프트 삽입이 초기성적 및 대동맥 벽의 변화)

  • Her, Keun;Won, Yong-Soon;Shin, Hwa-Kyun;Yang, Jin-Sung;Baek, Kang-Seok
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.648-654
    • /
    • 2010
  • Background: This study assessed the early results of endovascular repair of acute type B aortic dissection and the aortic wall changes following endovascular repair. Material and Method: From July 2008 to May 2009, the preoperative and follow-up computed tomography (CT) scans of 5 patients with acute type B aortic dissection were evaluated, and these patients had underwent stent graft implantation within 13 days of the onset of dissection (mean: 7 days; range: 3~13). The whole lumen (WL), true lumen (TL) and false lumen (FL) diameters were measured at the proximal (p), middle (m) and distal (d) third of the descending thoracic aorta. Result: The study included four men and one woman with an average age of $59.4{\pm}20.1$ years (age range: 37~79 years). The follow-up CT was performed and evaluated at 7 days and 6 months. The primary tear was completely sealed in all the patients. No paraplegia, paresis or peripheral ischemia occurred and none of the patients died. No endoleaks developed in any of the patients during follow-up. The TL diameters increased from 20.4 to 33.5 mm in the proximal third (p/3), from 19.5 to 29.8 mm in the middle third (m/3) and from 15.2 to 23.5 mm in the distal third (d/3). The FL diameters decreased from 18.7 to 0 mm in the p/3, from 15.4 to 0 mm in the m/3 and from 21.4 to 8.7 mm in the d/3. The changes in the TL diameter were statistically significant in the middle and distal aorta, and those changes in the FL diameter were not statistically significant. There was a decrease in the WL after repair, but this was not statistically Significant. In three patients, the false lumen disappeared completely on follow-up CT at 6 months. Two patients had patent false lumens and no thrombosis. Conclusion: The early results showed that endovascular repair was effective in treating acute type B aortic dissection, and endovascular repair promoted positive aortic wall changes.

The Adjunctive Role of Resectional Surgery for the Treatment of Multidrug-Resistant Pulmonary Tuberculosis (다제내성 폐결핵의 치료에서 폐절제술의 보조적인 역할)

  • Koh, Won-Jung;Lee, Jae-Ho;Yoo, Chul-Gyu;Kim, Young-Whan;Chung, Hee-Soon;Sung, Sook-Whan;Im, Jung-Gi;Kim, Joo-Hyun;Shim, Young-Soo;Han, Sung-Koo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.975-991
    • /
    • 1997
  • Background : Many patients with isoniazid and rifampin-resistant pulmonary tuberculosis have organisms that are also resistant to other first-line drugs. Despite of aggressive retreatment chemotherapy, the results are often unsuccessful, with a failure rate approaching 40%. Recently, there has been a revival of resectional surgery for the treatment of multidrug-resistant pulmonary tuberculosis. Methods : A retrospective analyses of the case records and radiographic findings were done. Between January 1991 and December 1995, 14 human immunodeficiency virus (HIV)-seronegative patients with multidrug-resistant pulmonary tuberculosis were selected for resection to supplement chemotherapy. All patients had organisms resistant to many of the first-line drugs, including both isoniazid and rifampin. Results : Despite of aggressive therapy for median duration of 9.5 months, 12 of the 14 patients (86%) were still sputum smear and/or culture positive at the time of surgery. The disease was generally extensive. Although main lesions of the disease including thick-walled cavities were localized in one lung, lesser amounts of contralateral disease were demonstrated in 10 of 14 (71%). Types of surgery performed were pneumonectomy including extrapleural pneumonectomy in six patients, lobectomy or lobectomy plus in six patients, and segmentectomy in two patients. The resected lung appeared to have poor function ; preoperative perfusion lung scan showed only 4.8% of the total perfusion to the resected portion of the lung. There were no operative deaths. Two patients had major postoperative complications including empyema with bronchopleural fistula and prolonged air leak, respectively. Of the 14 patients, 13 (93%) remained sputum-culture-negative for M. tuberculosis for a median duration of 23 months and one remained continuously sputum smear and culture positive for M. tuberculosis. Conclusion : On the basis of comparison with historical controls, adjunctive resectional surgery appears to play a significant beneficial role in the management of patients with multidrug-resistant pulmonary tuberculosis if the disease is localized and there are adequate reserve in pulmonary function.

  • PDF

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Effectiveness of head-up tilt test for the diagnosis of syncope in children and adolescents (소아청소년 실신 환자에서 기립 경사 검사의 유용성)

  • Yu, Ka-Young;Choi, Ji-Hye;Yoo, Chun Ja;Rhee, Kyoung Suk;Joo, Chan Uhng
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.798-803
    • /
    • 2009
  • Purpose : We aimed to examine the effectiveness of the head-up tilt test (HUT) for the diagnosis of syncope or presyncope in children and adolescents. Methods : HUT results and clinical features of 160 children and adolescents with syncope or presyncope were studied from May 2003 through March 2008 at the Chonbuk National University Hospital. The children and adolescents were subjected to $70^{\circ}$ HUT for 45 minutes. The testees were divided into 2 groups: group I (children) comprising 39 children in the age range 7-12 years (mean, $10.59{\pm}1.60$ years) and group II (adolescents) comprising 121 adolescents in the age range 13-20 years (mean, $15.93{\pm}2.28$ years). Positive result rates of the HUT and types of hemodynamic response to the test in the 2 groups were compared. Results : Of the 160 testees, 92 (57.5%) showed positive HUT results; they showed 3 patterns of response to tilting. Twelve patients showed a predominantly vasodepressor response; 10 patients showed a cardioinhibitory response; and 70 patients showed a mixed response. The positive result rates were 43.6% (17/39) and 62.0% (75/121) in groups I and II, respectively. Mixed response was the predominant positive hemodynamic response in both the groups. Conclusion : The HUT is a useful diagnostic tool for evaluating the condition of pediatric patients, including adolescents, with syncope. Further, it may be considered as the first step for evaluating the condition of such patients.

The Usefulness of Scintigraphy for the Detection of Gastroesophageal Reflux and Pulmonary Aspiration (위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성)

  • Kang, Sung-Kil;Hyun, In-Young;Lim, Dae-Hyun;Kim, Jeong-Hee;Son, Byong-Kwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.12-20
    • /
    • 2008
  • Purpose: Chronic pulmonary disease may be caused by aspiration of gastric contents secondary to gastroesophageal reflux. At present, there is no gold standard for documenting pulmonary aspiration. The purpose of this study was to investigate the usefulness of radionuclide scintigraphy in the detection of gastroesophageal reflux and pulmonary aspiration. Methods: Thirty-five patients with suspected aspiration pneumonia, and five normal control subjects, were included in the study. All subjects underwent gastroesophageal reflux scintigraphy after the ingestion of a $^{99m}Tc$-tin colloid mixture. Dynamic images to detect gastroesophageal reflux were obtained for 1 hour. Additional static images of the chest, to detect lung aspiration, were obtained at 6 and 24 hours after oral ingestion of the tin colloid. In addition to visual analysis, pulmonary aspiration was quantitated by counting the number of pixels labeled with radioactive isotope in the region of interest (ROI) of both lung fields. Aspiration index (AI) was obtained by subtracting the pixel counts of the background from the pixel counts of the ROI. Results: Among 35 patients with suspected aspiration pneumonia, 23 proved to have gastroesophageal reflux by scintigraphy. One patient showed definite pulmonary accumulation of activity by visual analysis of the 6-hour image. Thirty of 35 (85.7%) patients showed higher AI beyond the upper limit of AI in the healthy controls. When we compared the reflux group with the non-reflux group, there was a significantly higher AI at 6 hours in the reflux group (p<0.05). Conclusion: The results suggest that radionuclide scintigraphy is useful in detecting small pulmonary aspiration in patients with suspected aspiration pneumonia secondary to reflux.

  • PDF