• Title/Summary/Keyword: 흉부촬영

Search Result 835, Processing Time 0.025 seconds

Endobronchial Lipoma Diagnosed by Chest CT - A Case Report - (흉부컴퓨터 단층촬영으로 진단된 기관지내 지방종 -1례 보고-)

  • 박찬범;김환욱;조덕곤;안명임;송소향;김치홍;유진영;조규도;이선희
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.39-42
    • /
    • 2003
  • Endobronchial lipomas are rare benign tumors that arise from the lung. They partially or totally obstruct the bronchial lumen, producing a variable degree of collapse, irreversible bronchiectasis, and pulmonary damage. Although bronchoscope, CT and MR are reported to be helpful in establishing the diagnosis, CT is highly specific and sensitive in detecting fatty tumor. They may be removed by endoscope or thoracotomy or lobectomy. We present a case of endobronchial lipoma completely obstructing the right middle lobe and postobstructive irreversible pulmonary change with review of literatures.

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.

A Quality Assurance on Digital Chest Radiography in Medical Institution for Pneumoconiosis : Compared with Analog Radiography (진폐요양기관의 흉부 디지털촬영과 아날로그촬영의 정도관리 비교)

  • Lee, Won-Jeong;Ko, Kyung-Sun;Park, Jai-Soung;Kim, Sung-Jin;Chu, Sang-Deok;Park, So-Young;Choi, Byung-Soon
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.85-91
    • /
    • 2010
  • Digital radiography has been replacing rapidly the analog radiography for diagnosis of pneumoconiosis. The purpose of this study is to compare quality control of digital radiography (DR) and analog radiography (AR) for chest radiography in medical institution for pneumoconiosis (MIP) For the first time, we visited MIP to evaluate the chest radiography which is used for patients with pneumoconiosis, including equipment, technical parameters and reading environment. There were 33 institutions. DR and AR were installed in 24 and 9 institutions, respectively. Between DR and AR, we compared the radiological technique (RT), image quality (IQ) and reading environment (RE) to use the guideline published by Occupational Safety and Health Research Institute (OSHRI). The image quality was rated by two experienced chest radiologists for pneumoconiosis with certified from OSHRI. The chest radiography equipment was not significantly difference between AR and DR, but there were significantly difference in tube voltage and grid ratio used for chest radiography except to tube current, exposure time. Statistically, DR is significantly higher in RT(70.3 vs. 43.8, p = 0.009), RE(77.7 vs. 33.3, p = 0.004) than AR, but it's not significantly difference in IQ (65.6 vs. 52.8, p = 0.050). AR and DR in RT were passed 33.3%, 75.0% respectively (p = 0.044) and 44.4%, 79.2% (p = 0.090) in IQ and 44.4%, 91.7% (p = 0.009) in RE. In MIP, DR needs to replace AR in diagnosis of pneumoconiosis.

Control module development for functional improvement of Chest Photographing Device (흉부촬영장치의 위치제어 기능 개선을 위한 제어 모듈 개발)

  • Lee, Jae-Gil;Park, A-Yong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.407-408
    • /
    • 2011
  • 본 논문에서는 현재 생산하고 있는 흉부 촬영 장치의 위치제어 기능을 개선하는 제어모듈의 개발에 대해 논하였다. 현재 생산되고 있는 흉부 촬영 장치는 스위치를 수동으로 조작하여 촬영에 적당한 위치에 도달하였을 때 멈춘 후 촬영을 하고 있다. 그러나 이 방식은 원하는 위치에 정확히 위치시키기 위해서는 원하는 위치가 될 때까지 스위치 조작을 반복하여야 한다. 따라서 단 한 번의 스위치 버튼을 누르기만 하면 정확한 위치에 도달하도록 스위치 모듈과 제어장치 모듈의 기능을 개선시켜 위치 설정을 위한 조작 시간을 줄이고 사용의 편의성을 향상시켜 업무의 효율성을 기할 수 있도록 하였다.

  • PDF

Radiography and Computed Tomography in Four Dogs with Lung Lobe Torsion (흉부 방사선 촬영과 컴퓨터단층촬영을 이용한 폐염전의 진단 4례)

  • Lee, Ki-Ja;Choi, Sung-Jin;Kim, Young-Hwan;Jeong, In-Seong;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.390-393
    • /
    • 2013
  • This case study describes the imaging features of radiography and computed tomography (CT) in four small breed dogs with lung lobe torsion. The medical records, thoracic radiographs and CT images of four dogs with confirmed lung lobe torsion were retrospectively reviewed. Pleural effusion and increased lobar opacity/density were seen on all CT and thoracic radiography in all four dogs. CT revealed narrowed/collapsed bronchus in all four dogs, while this was only appreciated on one thoracic radiography. The vesicular emphysema pattern was seen on four CT but only on three radiographic examinations. The specific findings of lung lobe torsion were vesicular emphysema and a narrowed/collapsed bronchus. These findings were more easily recognized on CT than with thoracic radiographs.

Spontaneous Hemothorax in a Patient with Posterior Mediastinal Neurilemmoma -A case report- (자발성 혈흉을 동반한 후종격동 신경섬유초종)

  • 김혁;양주민;정기천;김영학;강정호;정원상
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1019-1021
    • /
    • 2004
  • Neurogenic tumors are common in posterior mediastinal tumors. In most cases, tumors were accidentally showed on simple chest X-ray. In some cases, they were presented by symptoms which were induced by nerve compression or airway compression. But as in our case, neurogenic tumor with spontaneous hemothorax is very rare. A 45-year-old man admitted to emergency room of other hospital because of acute right chest pain and dyspnea. A chest X-ray showed a right pleural effusion. Hemothorax was diagnosed after closed thoracostomy. Following chest CT showed posterior mediastinal mass. The patient was transferred to our hospital. T spine MRI showed dumbbell shaped mass. Diagostic impression was neurogenic tumor. The pathologic result was neurilemmoma after surgical resection.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.