• Title/Summary/Keyword: 휴대용계측기

Search Result 18, Processing Time 0.017 seconds

Development of the PDA Based Mobile System for Body Fat Measurement and Diagnosis Using Bioelectrical Impedance Method (체임피던스 방법을 이용한 PDA 기반의 휴대용 체지방 측정 및 진단 시스템 개발)

  • 권세윤;이상민;김재환;우지환;김인영;이형기;방석원;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2004
  • Recently, many people want to know their state of health, such as a body fat rate, anywhere and anytime. The Personal Digital Assistance(PDA) is the portable wireless apparatus that has become widely popular. There are many application areas of the IDA to be in mobile care devices. In this study, we developed the PDA based body fat measurement system, composed of a cradle type measurement module and a WindowCE operated software module, a regression equation for predicting lean body mass (LBM). Sixty-three weight-stable subjects (53 men, 10 women) aged 20∼32yr participated in this study. A regression model, LBM = (0.0005*Height2 - 0.0160*Impedance + 0.3920*Weight - 0.0684*Age - 5.8141*Sex + 25.984, was found. The correlation coefficient( r) of body fat rate between developed system and HTM1000plus(BionetTM) was 0.928. HTM1000plus is a commercially available and approved by KFDA. These results indicated that developed system is reliable for estimation of body fat rate. Although developed system is the PDA based miniaturized, it shows good performance comparing with other commercial product.

Radiological Environment Investigation of Radioactive Waste Disposal Facility (방사성폐기물 처분시설 주변의 방사선환경조사)

  • Baek, Jeong-Seok;Jeong, Yeui-Young;Ahn, Sang-Bok;Kim, Wan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.387-398
    • /
    • 2008
  • To obtain base-line data in the low- and intermediate-level radioactive waste disposal facility, radiological environment investigation is required at least two years prior to the facility operation near the disposal facility. The investigation has been performed since January 2007 for the Wolsong LILW disposal center. In this paper, investigation procedure and detailed information obtained for six months in 2008 are described. Based on the current results, future investigation planning is also discussed for the radiological environment management of the disposal facility.

  • PDF

Design and Implementation of IoT Terminal Equipment for Vessels using Thuraya Geo-stationary Orbit Satellite (Thuraya 정지궤도 위성을 이용한 선박용 IoT 단말 장치 설계 및 구현)

  • Jang, Won-Chang;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 2020
  • Satellite communication is not used by many people like mobile communication, but it is a necessary technology for public service and communication services, such as providing the Internet in military, disaster, remote education and medical services, island areas, and infrastructure vulnerable areas. However, on ships and aircraft, mobile communications requiring base stations are either unavailable or restricted in their use. In this paper, we used a Raspberry Pi board as the terminal device to communicate network through satellite modem and PPP protocol, and implemented two-way data link using the text message of the modem to connect to the Thuraya geo-stationary orbit network. In addition, I/O devices were connected to the controller of the terminal equipment to design and implement an IoT device system for ships that can remotely access the system under control and control I/Os and transmit measured data through various sensors.

Development of Nondestructive Detecting System for Elevator Wire Ropes using Hall-effect Sensors (Hall 센서를 이용한 엘리베이터 와이어 로프의 비파괴 검출시스템의 개발)

  • Kim, Sung-Duck
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.33-41
    • /
    • 2001
  • Wire ropes have been widely used in industrial applications, wherever heavy weight should be carried safely or mechanical energy should be transmitted fast. Especially, wire rope failures in operating elevator may lead to extensive property damage and serious injury to nearby personnel. Hence, it is very important to inspect wire rope periodically. Failure defection of wire rope requires fundamental knowledge of wire rope construction, rope behavior, properties of fault, sensing and signal processing method. In this research, the development of a new fault detecting system incorporating Hall-effect sensors to detect flaws such as abrasion, broken wire, corrosion and deformation for aged wire ropes in elevator, is described. For using a detector as a portable instrument, several performances for implementing sensing part with Hall-effect sensor, analog signal processing unit and programs are described. Experiments and field testing results for the implemented detecting system are also given. As a result, it is verified that the detecting system has good efficiency for inspecting faults of aged wire ropes in service.

  • PDF

Establishment of the Monoenergetic Fluorescent X-ray Radiation Fields (교정용 단일에너지 형광 X-선장의 제작)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jae-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.33-47
    • /
    • 1998
  • Using a combination of an X-ray generator Installed in radiation calibration laboratory of Korea Atomic Energy Research Institute (KAERI) and a series of 8 radiators and filters described in ISO-4037, monoenergetic fluorescent X-rays from 8.6 keV to 75 keV were produced. This fluorescent X-rays generated by primary X-rays from radiator were discriminated $K_{\beta}$ lines with the aid of filter material and the only $K_{\alpha}$ X-rays were analyzed with the high purity Ge detector and portable MCA. The air kerma rates were measured with the 35 co ionization chamber and compared with the calculational results, and the beam uniformity and the scattered effects of radiation fields were also measured. The beam purities were more than 90 % for the energy range of 8.6 keV to 75 keV and the air kerma rates were from 1.91 mGy/h (radiator : Au, filter : W) to 54.2 mGy (radiator : Mo, filter : Zr) at 43 cm from center of the radiator. The effective area of beam at the measurement point of air kerma rates was 12 cm ${\times}$ 12 cm and the influence of scattered radiation was less than 3 %. The fluorescent X-rays established in this study could be used for the determination of energy response of the radiation measurement devices and the personal dosemeters in low photon energy regions.

  • PDF

Implementation and Evaluation of Electroglottograph System (전기성문전도(EGG) 시스템의 개발 및 평가)

  • 김기련;김광년;왕수건;허승덕;이승훈;전계록;최병철;정동근
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.343-349
    • /
    • 2004
  • Electroglottograph(EGG) is a signal recorded from the vocal cord vibration by measuring electrical impedance across the vocal folds through the neck skin. The purpose of this study was to develop EGG system and to evaluate possibility for the application on speech analysis and laryngeal disease diagnosis. EGG system was composed of two pairs of ring electrodes, tuned amplifier, phase sensitive detector, low pass filter, and auto-gain controller. It was designed to extract electric impedance after detecting by amplitude modulation method with 2.7MHz carrier signal. Extracted signals were transmitted through line-in of PC sound card, sampled and quantized. Closed Quotient(CQ), Speed Quotient(SQ), Speed Index(SI), fundamental frequency of vocal cord vibration(F0), pitch variability of vocal fold vibration (Jitter), and peak-to-peak amplitude variability of vocal fold vibration(Shimmer) were analyzed as EGG parameters. Experimental results were as follows: the faster vocal fold vibration, the higher values in CQ parameter and the lower values in SQ and SI parameters. EGG and speech signals had the same fundamental frequency. CQ, SQ, and SI were significantly different between normal subjects and patients with laryngeal cancer. These results suggest that it is possible to implement portable EGG system to monitor the function of vocal cord and to test functional changes of the glottis.

A Measurement of the Exposure Rates by Terrestrial y-rays in Taegu Area (대구지역(大邱地域) 지각(地殼) ${\gamma}$-선(線)의 조사선량율(照射線量率) 측정(測定))

  • Chang, Si-Ho;Jeong, Chun-Gyun;Kang, Hee-Dong;Lee, Mo-Sung;Choi, Mun-Kyu;Kim, Wi-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.121-132
    • /
    • 1994
  • This study concerns about the measurement and the investigation of environmental radiation characteristics which the components and the distribution of exposure rates by terrestrial y-rays in Taegu area. $4^{'}{\phi}{\times}4^{'}$ NaI(T1) scintillation detector with a multichannel analyzer was used in the measurement of y-rays as a part of in-situ spectrometry at twenty eight different locations in this area. The conversion into the exposure rate from the measured ${\gamma}-ray$ spectrum has been carried out leading to a net exposure rate and component ones by $^{40}K,\;^{238}U$ series and $^{232}Th$ series products which are known by the major parts in the terrestrial ${\gamma}-rays$ generally. As a result, the average exposure rate by the terrestrial ${\gamma}-rays$ in Taegu area is $9.4{\mu}R/h$ and the distribution of individual exposure rates shows more or less differences between these locations even after the consideration of diurnal and yearly variations which are always involved in these measurements. The component parts of exposure rates are distributed $^{40}K\;2.9{\sim}4.6{\mu}R/h,\;^{238}U$ series $1.2{\sim}3,\;1{\mu}R/h,\;^{232}Th$ series $2.5{\sim}5.0{\mu}R/h$ over the measured locations.

  • PDF

Development of a Portable-Based Smart Structural Response Monitoring System and Evaluation of Field Applicability (포터블 기반 스마트 구조 응답 모니터링 시스템 개발 및 현장 적용성 평가)

  • Sangki Park;Dong-Woo Seo;Ki-Tae Park;Hojin Kim;Thanh Bui-Tien;Lan Nguyen-Ngoc
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.147-156
    • /
    • 2023
  • Because the behavior of cable bridges is dominated by dynamic response and is relatively complex, short- and long-term field monitoring are often required to evaluate the bridge condition. If a permanent SHMS (Structural Health Monitoring System) is not installed, a portable monitoring system is needed for the checking of bridge condition. In this case, it can be difficult to operate the portable monitoring system due to limited conditions such as power and communication according to the location and type of the bridge. In this study, the portable-based smart structural response monitoring system is developed that can be effectively used for short- and long-term monitoring of cable bridges in Korea and Southeast Asia. The developed system is a multi-channel portable data acquisition and analyzer that can be operated for a long time in the field using its own power supply system, and is included with the automated analysis algorithm for the dynamic characteristics of cable bridges using real-time data. In order to evaluate the field applicability of the developed system, field demonstration was conducted on cable bridges in Korea and Vietnam. Through the demonstration, the reliability and efficiency of field operation of the developed system were confirmed, and additionally, the possibility of application to overseas markets was confirmed in cable bridge monitoring field.