• Title/Summary/Keyword: 휘도 차

Search Result 166, Processing Time 0.042 seconds

Performance Analysis of Pressure-retarded Osmosis Power Using Biomimetic Aquaporin Membrane (생체모방형 아쿠아포린 분리막을 이용한 압력지연삼투 발전 성능분석)

  • Choi, Wook;Bae, Harim;Lee, Hyung-Keun;Lee, Jonghwi;Kim, Jong Hak;Park, Chul Ho
    • Polymer(Korea)
    • /
    • v.39 no.2
    • /
    • pp.317-322
    • /
    • 2015
  • Salinity gradient power is a system which sustainably generates electricity for 24 hrs, if the system is constructed at a certain place where both seawater and river water are consistently pumped. Since power is critically determined by the water flux and the salt rejection, a membrane of water-semipermeable aquaporin protein in cell membranes was studied for pressure-retarded osmosis. NaCl was used as a salt, and $NaNO_3$ was used as a candidate to check the ion selectivity. The water flux of biomimetic aquaporin membranes was negligible at a concentration below 2M. Also, there is no remarkable dependence of water flux and ion selectivity on concentrations higher than 3M. Therefore, the biomimetic aquaporin membrane could not be applied into pressure-retarded osmosis; however, if a membrane could overcome the current limitations, the properties shown by natural cells could be accomplished.

Estimation and Analysis of the Vertical Profile Parameters Using HeMOSU-1 Wind Data (HeMOSU-1 풍속자료를 이용한 연직 분포함수의 매개변수 추정 및 분석)

  • Ko, Dong-Hui;Cho, Hong-Yeon;Lee, Uk-Jae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.3
    • /
    • pp.122-130
    • /
    • 2021
  • A wind-speed estimation at the arbitrary elevations is key component for the design of the offshore wind energy structures and the computation of the wind-wave generation. However, the wind-speed estimation of the target elevation has been carried out by using the typical functions and their typical parameters, e.g., power and logarithmic functions because the available wind speed data is limited to the specific elevation, such as 2~3m, 10 m, and so on. In this study, the parameters of the vertical profile functions are estimated with optimal and analyzed the parameter ranges using the HeMOSU-1 platform wind data monitored at the eight different locations. The results show that the mean value of the exponent of the power function is 0.1, which is significantly lower than the typically recommended value, 0.14. The values of the exponent, the friction velocity, and the roughness parameters are in the ranges 0.0~0.3, 0~10 (m/s), and 0.0~1.0 (m), respectively. The parameter ranges differ from the typical ranges because the atmospheric stability condition is assumed as the neutral condition. To improve the estimation accuracy, the atmospheric condition should be considered, and a more general (non-linear) vertical profile functions should be introduced to fit the diverse profile patterns and parameters.

An exploratory study on the impacts of International Digital Tax Agreement on Korean Industry (디지털세 국제 합의가 국내 산업에 미치는 영향에 대한 탐색적 연구)

  • Lee, Jinhui;Kim, Taeyeol
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.10-31
    • /
    • 2021
  • The digital tax, recently referred to as the Google tax was finally agreed at the 31st General Assembly of the OECD (October 8, 2021) with full support by 136 countries and will take effect from 2023. The purpose of this study is to analyze the digital tax prepared by the OECD for global MNEs, and to suggest the impacts on the Korean industry and to present the Korean governmental countermeasures. As the first study, we analyzed the international agreement on digital tax. In results, we found that even if global MNEs do not set up a business operation in overseas countries, if sales and profits are generated, 25% of the excess profit is borne as tax (pillar 1), and when MNEs do business in all the countries, they are liable to at least a 15% tax (pillar 2). We think that countries around the world have prepared a minimum countermeasure to protect their companies in anticipation that global MNEs will easily encroach on their markets in the future. As the second study, in order to discover the reason why the MNEs are so strong, we investigated the trends of Google and B2B SaaS companies in details. In results, we discovered that the global MNEs establishes a digital platform partnership ecosystem that enables them to enter foreign markets easily and expand rapidly. In conclusion, as a countermeasure for the Republic of Korea, governmental policies were proposed at the corporate (startup nurturing), industry, and national level respectively.

Appropriate Technology and Field Application of Non-powered Water Purification System Using Nanofiber Membrane (나노섬유 멤브레인 기반 무동력 정수 시스템의 적정기술 및 현장 적용)

  • Lee, Jin;Yun, Byeong Gweon;Han, Kyoung Gu;Lee, Seung Hoon;Kim, Cheol Hyeon;Kim, Chan;Lee, Yunho;Lee, Dongwhi;Lee, Seunghyeok;Kim, Kyoung-Woong
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.72-81
    • /
    • 2021
  • Gravity-driven membrane (GDM) filtration system based on the nanofiber membrane was investigated. This system can be operated with little energy demand due to a gravitational pressure-driven filtration and biological fouling control strategy. Moreover, the optimal module configuration based on the high permeance of nanofiber membrane can provide a significantly high water productivity. In order to evaluate its applicability potential, the pilot-scale (3000-5000 L/day) systems with nanofiber membranes were operated in developing countries (Kiribati and Tuvalu). Our results showed that the 14-92 L/(m2×h) of the permeate flux was determined indicating a stabilized water productivity. In addition, the permeate water indicated a high removal rate (more than 99.99%) of turbidity and bacteria. Consequently, the system can provide a stabilized water production with safe permeate water quality during long-term operation. These findings exemplify an effective approach to decentralized drinking water treatment for developing countries.

Comparison of Measured Natural Frequencies of a Railway Bridge Specimen Between Different Excitation Methods (철도교량 시험체의 가진방법에 따른 고유진동수 측정치 변동에 대한 비교 분석)

  • Kim, Sung-Il;Lee, Jungwhee;Lee, Pil-Goo;Kim, Choong-Eon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.535-542
    • /
    • 2010
  • Precise estimation of a structure's dynamic characteristics is indispensable for ensuring stable dynamic responses during lifetime especially for the structures which can experience resonance such as railway bridges. In this paper, the results of forced vibration tests of different excitation methods (vibration exciter and impact hammer) are compared to examine the differences and the cause of differences of extracted natural frequencies. Consequently a natural frequency modification method is suggested to eliminate effects of non-structural disturbance factors. Also, sequential forced vibration tests are performed before and after track construction according to the construction stage of a railway bridge, and the variation of natural frequencies are examined. Effect of added mass of vibration exciter and variation of support condition due to the level of excitation force are concluded as the major cause of natural frequency differences. Thus eliminating these effects can enhance the reliability of the extracted natural frequencies. Construction of track affects not only the mass of structure but also the stiffness of the structure. Also, the amount of increase in stiffness varies according to the level of structural deflection. Therefore, reasonable estimation of the level of structural response during operation is important for precise natural frequency calculation at design phase.

Discrimination Analysis of Production Year of Rice and Brown Rice based on Phospholipids (인지질을 이용한 쌀과 현미의 생산연도 판별 분석)

  • Hong, Jee-Hwa;Ahn, Jongsung;Kim, Yong-Kyoung;Choi, Kyung-Hu;Lee, Min-Hui;Park, Young-Jun;Kim, Hyun-Tae;Lee, Jae-Hwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.62 no.2
    • /
    • pp.105-112
    • /
    • 2017
  • The mixing of rice and brown rice produced in different years is banned in Korea by the grain management act. However, there has been no reported method for discriminating the production year of rice. The objective of this study was to develop a method for discriminating the production year of rice and brown rice based on their phospholipids content. One hundred rice samples and 130 brown rice samples produced between 2012 and 2015 were collected. Twelve phosphatidylcholine components were analyzed by liquid chromatography-tandem mass spectrometry. Phosphatidylcholine was used as an internal standard to calculate the peak intensity of the samples. A statistical analysis of the results showed that the centroid distance between the stale and new rice was 4.16 and the classification ratio was 97%. To verify the calculated discriminant, 61 and 40 rice samples were collected. The accuracy of discrimination was 82% by primary verification and 80% by secondary verification. The statistical analysis of brown rice showed that the centroid distance between the stale and new brown rice was 3.14 and the classification ratio was 96%. To verify the calculated discriminant, 10 samples of new rice and 30 samples of stale rice were collected and the accuracy of discrimination was 93%. The accuracy of discrimination for rice stored at room temperature was 57.9-92.1% and that for rice stored at a low temperature was 86.8-94.7%, depending on the storage period. For brown rice, the detection accuracy was 94.7-100% at room temperature and 92.1-100% at a low temperature, depending on the storage period. The accuracy of discrimination for rice was affected by the storage temperature and time, while that for brown rice was more than 92% regardless of the storage conditions. These results suggest that the developed discriminant analysis method could be utilized to determine the production year of rice and brown rice.

Seasonal and Yearly Variations of Atmospheric Extinction Coefficient at Campus Station of Chungbuk National University Observatory from 2005 to 2007 (충북대학교 천문대 교내관측소에서 측정된 2005년부터 2007년까지의 대기소광계수의 계절별, 년도별 변화)

  • Kim, Chun-Hwey;Cha, Sang-Mok;Choi, Young-Jae;Song, Mi-Hwa;Park, Jang-Ho;Won, Jang-Hee;Yim, Jin-Sun;Cho, Myung-Shin;Park, Eun-Mi;Jeong, Jang-Hae
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.2
    • /
    • pp.101-112
    • /
    • 2008
  • Systematic CCD observations of times of minimum lights for eclipsing binaries has been carried out from 2002 to 2007 at Campus Station of Chungbuk National University Observatory which is located in Cheongju city, Korea. As a by-product of our observations, photometric data for stars in CCD images taken from 2005 to 2007 were used to determine 1st order atmospheric extinction coefficient (hereafter AEC) and seasonal and yearly variations of the AECs were studied. Total nights used for determination of AECs were 57 days in 2005, 51 days in 2006, and 63 days in 2007. As a result the annual mean value of the AECs per air mass is calculated as $0.^m34{\pm}0.^m18$ for 2005, $0.^m38{\pm}0.^m19$ for 2006, and $0.^m45{\pm}0.^m20$ for 2007. These values show that the AECs and their standard deviations are two and four times, respectively, larger than those of normal observatories which are not located near large cities. Annual comparison between concentration of atmospheric fine dust and coefficient of atmospheric extinction show strong correlation between two quantities of which time variations show similar patterns. The AECs for the east sky show larger than those for the west sky. It can be easily understood by the reasonable possibility that air pollutants remain more in the east sky than in the west because the east area of Cheongju city has been more developed than the west one. In conclusion the atmospheric extinction of the night sky of Cheongju city has an annual trend of increase of $0.^m06\;airrnass^{-1}\; year^{-1}$ implying that it may take only about 13 years for Cheongju city to have 2 times brighter night sky than the present one. Our study highlights that variations of AEC can be used as an important indicator of air pollution to monitor night skies.

Fog Detection over the Korean Peninsula Derived from Satellite Observations of Polar-orbit (MODIS) and Geostationary (GOES-9) (극궤도(MODIS) 및 정지궤도(GOES-9) 위성 관측을 이용한 한반도에서의 안개 탐지)

  • Yoo, Jung-Moon;Yun, Mi-Young;Jeong, Myeong-Jae;Ahn, Myoung-Hwan
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.450-463
    • /
    • 2006
  • Seasonal threshold values for fog detection over the ten airport areas within the Korean Peninsula have been derived from the data of polar-orbit Aqua/Terra MODIS and geostationary GOES-9 during a two years. The values are obtained from reflectance at $0.65{\mu}m\;(R_{0.65})$ and the difference in brightness temperature between $3.7{\mu}m\;and\;11{\mu}m\;(T_{3.7-11})$. In order to examine the discrepancy between the threshold values of two kinds of satellites, the following four parameters have been analyzed under the condition of daytime/nighttime and fog/clear-sky, utilizing their simultaneous observations over the Seoul metropolitan area: brightness temperature at $3.7{\mu}m$, the temperature at $11{\mu}m,\;the\;T_{3.7-11}$ for day and night, and the $R_{0.65}$ for daytime. The parameters show significant correlations (r<0.5) in spatial distribution between the two kinds of satellites. The discrepancy between their infrared thresholds is mainly due to the disagreement in their spatial resolutions and spectral bands, particularly at $3.7{\mu}m$. Fog detection from GOES-9 over the nine airport areas except the Cheongju airport has revealed accuracy of 60% in the daytime and 70% in the nighttime, based on statistical verification. The accuracy decreases in foggy cases with twilight, precipitation, short persistence, or the higher cloud above fog. The sensitivity of radiance and reflectance with wavelength has been analyzed in numerical experiments with respect to various meteorological conditions to investigate optical characteristics of the three channels.

Development of Manual Multi-Leaf Collimator for Proton Therapy in National Cancer Center (국립암센터의 양성자 치료를 위한 수동형 다엽 콜리메이터 개발)

  • Lee, Nuri;Kim, Tae Yoon;Kang, Dong Yun;Choi, Jae Hyock;Jeong, Jong Hwi;Shin, Dongho;Lim, Young Kyung;Park, Jeonghoon;Kim, Tae Hyun;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • Multi-leaf collimator (MLC) systems are frequently used to deliver photon-based radiation, and allow conformal shaping of treatment beams. Many proton beam centers currently make use of aperture and snout systems, which involve use of a snout to shape and focus the proton beam, a brass aperture to modify field shape, and an acrylic compensator to modulate depth. However, it needs a lot of time and cost of preparing treatment, therefore, we developed the manual MLC for solving this problem. This study was carried out with the intent of designing an MLC system as an alternative to an aperture block system. Radio-activation and dose due to primary proton beam leakage and the presence of secondary neutrons were taken into account during these iterations. Analytical calculations were used to study the effects of leaf material on activation. We have fabricated tray model for adoption with a wobbling snout ($30{\times}40cm^2$) system which used uniform scanning beam. We designed the manual MLC and tray and can reduce the cost and time for treatment. After leakage test of new tray, we upgrade the tray with brass and made the safety tool. First, we have tested the radio-activation with usually brass and new brass for new manual MLC. It shows similar behavior and decay trend. In addition, we have measured the leakage test of a gantry with new tray and MLC tray, while we exposed the high energy with full modulation process on film dosimetry. The radiation leakage is less than 1%. From these results, we have developed the design of the tray and upgrade for safety. Through the radio-activation behavior, we figure out the proton beam leakage level of safety, where there detects the secondary particle, including neutron. After developing new design of the tray, it will be able to reduce the time and cost of proton treatment. Finally, we have applied in clinic test with original brass aperture and manual MLC and calculated the gamma index, 99.74% between them.

Tropospheric Ozone over the Seoul Metropolitan Area Derived from Satellite Observations (MODIS) and Numerical Simulation (위성관측(MODIS)에서 유도된 수도권 지역의 대류권 오존 및 수치실험)

  • Yoo Jung-Moon;Park Yoo-Min;Lee Suk-Jo
    • Journal of the Korean earth science society
    • /
    • v.26 no.3
    • /
    • pp.283-296
    • /
    • 2005
  • The effect of ozone and surface temperature on the ozone band at $9.7{\mu}m$ has been investigated from radiative transfer theory together with observations in order to derive empirical methods for remotely sensing ground-ozone concentration. Simultaneous observations of satellite (MODIS Aqua; ECT 13:30) and ground-ozone at 79 stations have been used over the Seoul Metropolitan Area (SMA; 125.7-127.2 E, 37.2-37.7 N) during four ozone-warning days in the year 2003. Cloud effect on the band in the methods was filtered out based on synoptic observations. Upwelling radiance values at $9.6{\mu}m$ which have been estimated at the given ozone concentration of 327-391 DU depend on surface temperature (Ts) showing $5.52\~5.78Wm^{-2}sr^{-1}\;at\;Ts = 290 K,\;and\;9.00\~9.57Wm^{-2}sr^{-1}$ Ts = 325K. Thus, the partitioned contributions of ozone and temperature to intensity of ozone absorption band are $0.26Wm^{-1}sr^{-1}/64\;DU\;and\;0.31 Wm^{-2}sr^{-1}/35K$, respectively. Here the intensity which has been used to remotely detect ground-ozone concentration from infrared satellite measurement is defined as the difference in brightness temperature between $11{\mu} m\;and\;9.7{\mu}m (i.e.,\; T_{11-9.7})$. The methods in this study have been applied to estimate ground-ozone from MODIS data in cases that there are significant correlations between the band intensity and ground-ozone. The values of estimated ozone significantly correlate (0.49-0.63) with ground observations at a significance level of $1\%$. For the improved methods, further study may be required to use tropospheric ozone rather than ground-ozone, considering the variation stratospheric ozone.