• Title/Summary/Keyword: 후판

Search Result 295, Processing Time 0.023 seconds

Evaluation of Mechanical Test Characteristics according to Welding Position in FCAW Heterojunction (FCAW 이종접합에서 용접자세에 따른 기계적 시험 특성 평가)

  • Cho, Byung-Jun;Lee, Soung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.649-656
    • /
    • 2019
  • Flux cored arc welding (FCAW), which is used widely in many fields, such as shipyards, bridge structures, construction machinery, and plant industry, is an alternative to shielded metal arc welding (SMAW). FCAW is used largely in the welding of carbon and alloy steel because it can be welded in all poses and obtain excellent quality in the field under a range of working conditions. In this study, the mechanical properties of welded parts were analyzed after different welding of SS400 and SM490A using FCAW. The following conclusions were drawn. The tensile test results satisfied the KS standard tensile strength in the range of 400~510 N/mm2 in all welding positions. The bending test confirmed that most of the specimens did not show surface breakage or other defects during bending and exhibited sufficient toughness, even after plastic deformation. The hardness test results were lower than the standard value of 350 Hv of KS B 0893. Similar to the hardness test, were greater than the KS reference value. The macro test revealed no internal flaws, non-metallic inclusions, bubbles or impurities on the entire cross section of the weld, and there were no concerns regarding lamination.

Microscopic Characteristics of the Olfactory Organ in the Gluttonous Goby Chaenogobius gulosus(Pisces, Gobiidae), Compared to Sympatric Intertidal Gobies (별망둑 the gluttonous goby Chaenogobius gulosus 후각기관의 해부, 조직학적 특성 및 동소 망둑어과 출현종들과의 비교연구)

  • Kim, Hyun Tae;Park, Jong Young
    • Korean Journal of Ichthyology
    • /
    • v.33 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Using stereo, light, and scanning electron microscopes, we researched the anatomical and histological structure of Chaenogobius gulosus's olfactory organ and compared it to those of sympatric gobies Luciogobius guttatus and Favonigobius gymnauchen. Results revealed the following common characteristics: i) tubular anterior nostril (AN) and flat posterior nostril (PN), ii) a single longitudinal lamella, iii) two accessory nasal sacs (ANS, ethmoidal and lacrimal), iv) abundant sensory epithelium lymphatic cells (LC), v) an eosinophil cell, and vi) a ciliary length a quarter of the knob diameter in the olfactory receptor neuron (ORN). Some characteristics are specific to C. gulosus and different from the other two gobies: i) 0.5~1.0 mm AN and 0.2~0.5 mm PN (vs. 0.2~0.3 mm and 0.2~0.3 mm in L. guttatus; 0.2~0.4 mm and 0.1~0.3 mm in F. gymnauchen), ii) two ANS (vs. absence in L. guttatus; two in F. gymnauchen), iii) abundant LC (vs. low in L. guttatus and F. gymnauchen), iv) low density non-sensory cilia on the lamellar surface (vs. high in L. guttatus; low in F. gymnauchen), and v) a quarter ciliary length to knob diameter ratio in the ORN (vs. mixture of a quarter to equal ratio in L. guttatus; two or three times in F. gymnauchen). From these results, we confirmed the C. gulosus olfactory organ has adapted anatomically and histologically to the sand-rock tidal zone.

Hot Pressing Technology for Improvement of Density Profile and Sound Absorption Capability of Particleboard (파티클보드의 밀도경사와 흡음성 개선을 위한 열압기술)

  • Park, Hee Jun;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2002
  • Improvement of density profile and sound absorption capability of particleboard was attempted. Three types of hot pressing methods examined ; flat-platen pressing method (A-type pressing), hot pressing in forming box (B-type pressing), and hot pressing set up jagged caul in forming box (C-type pressing). The raw materials were larch(Larix leptolepis (S, et. Z.) Gorden) shavings, phenol formaldehyde resin, and the particleboard perforated with stair type. The physical and mechanical properties such as specific gravity, bending strength (MOR), internal bonding strength (IB) and sound absorption coefficients were examined. The results are summarized as follows : 1) The MOR and internal bonding strength of the board pressed in forming box were higher than those of flat-platen pressed board. 2) The minimum density to average density ratio in thickness direction which pressed in forming box showed about 923%, in the case of 35 mm commercial particleboard and 50 mm flat-platen pressed board, its values showed about 66.4% and 865% respectively. 3) Sound absorption coefficients of the particleboard perforated with stair type were higher than those of flat-plated pressed board and commercial particleboard.

Case Study on Economical Fabrication and Erection of Steel Structure and Reduction in Field Erection Time (경제적 철골제작$\cdot$설치 및 공기단축 사례분석연구)

  • Ahn Jae-Bong;Choi Yoon ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.5 s.21
    • /
    • pp.183-192
    • /
    • 2004
  • Even in Korea the number of steel structure buildings that allow internal space and easy change of their layouts in accordance with the purpose of buildings and box-type steel bridges constructed with thick plates with thickness in a rage just from a few $\beta$AE to \$100\beta$AE is increasing these days and therefore, domestic fabrication and processing technology of members for steel structures is being improved at a pace faster than in the past to meet the growing requirements of consumers for high reliability on quality control on the related steel structures. However, most domestic fabricators os steel structures who are turning out their steel products in accordance with the designs prepared by engineering companies in their respective works for the sake of cost cut more than anything else, hesitating to introduce any advanced new technology into themselves. In the case of the steel structure design application for small and mid-size buildings in particular, it is quite meaningful not only for those who are involved in steel structure business, but also for the people working at construction work fields to review the result of the study on the connections of steel structure members deigned to obtain superb quality of steel structures within short period for steel fabrication and erection at fields in economical ways, as there is a glowing tendency seeking standardization of connection of steel structure members as well as whole structure together with the development on design of construction system of buildings including their exterior and interior decoration materials, manufacture of the related members and fabrication technique structure. This paper has been prepared with the aim to review the peculiar characteristics of buildings constructed with the main frames of steel structures and actual cases of the change made ing the connections between steel structure columns and between columns and girder members in order to reduce the work period necessary for fabrication and erection of steel structures at the maximum as well as the some examples of steel structures fabricated through automatic welding by robots for box-type columns in addition to the description of the problems found in the course of fabricating those steel structures, suggesting possible counter-measures to solve them.

Mitral Valvuloplasty using New Mitral Strip (Mitracon^{(R)}$) (새로운 Strip (Mitracon^{(R)}$)을 이용한 승모판막 성형술)

  • Kang, Seong-Sik;Kim, Sang-Pil;Song, Meong-Gum
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.320-328
    • /
    • 2008
  • Background: Numerous surgical devices for mitral repair have been used in the past with good results. In this study we describe a simple annuloplasty technique with using a new device ($Mitracon^{(R)}$). The aim of this study was to assess its efficacy and surgical results with using $Mitracon^{(R)}$. Material and Method: From May 2003 to October 2005, 46 patients (21 women and 25 men (mean age of $51.4{\pm}17.8$ years) with mitral regurgitation from various causes were treated with either the $Mitracon^{(R)}$ (the $Mitracon^{(R)}$ group) or the Capentier Edward rigid ring (the CE group). The median follow-up duration was 18.9 months. Result: The mean grade of mitral regurgitation before and immediately after surgery in the $Mitracon^{(R)}$ group and the CE group decreased from $3.2{\pm}0.8$ to $0.6{\pm}0.7$ and $3.4{\pm}0.7$ to $0.3{\pm}0.5$, respectively. There were no significant changes in the ejection fraction either between the two groups or before and immediately after surgery. No deaths were seen in either group. Early postoperative echocardiography of all 46 patients showed only trivial mitral regurgitation or none at all. Echocardiography at a median of 18.9 months also showed no progression in mitral regurgitation. The mean grade of mitral regurgitation in the $Mitracon^{(R)}$ group at this time point decreased from $3.2{\pm}0.8$ to $0.8{\pm}0.7$ (p<0.05). The CE group also showed a similar degree of decrease from $3.4{\pm}0.7$ to $0.3{\pm}0.6$ (p<0.05). The mitral valve area in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.3{\pm}0.9cm^2$. The mitral valve area in the CE group was $2.7{\pm}0.6cm^2$. The mean mitral pressure gradient in the $Mitracon^{(R)}$ group at 1 year follow-up was $3.1{\pm}1.3$ mmHg. The mean pressure gradient in the CE group was $4.5{\pm}2.1$ mmHg, although any statistical significant difference for this between the groups was not reached. Conclusion: The present study showed the described technique to be safe and effective in the intermediate term. Because long term results are unavailable, a more extensive prospective randomized multicenter trial may be warranted to determine whether this procedure should be generally applied for repair of mitral valve disease.