R&D Efficiency Analysis Case of the Machine Tools Industry by Using DEA (DEA를 활용한 민간 기업의 R&D 효율성 분석 사례: 공작기계 A사를 중심으로)

  • Jeon, Soo-Jin;Lee, Jin-Soo;Hong, Jae-Bum
    • Journal of Technology Innovation
    • /
    • v.24 no.4
    • /
    • pp.27-53
    • /
    • 2016
  • This case analyzed the efficiency of 79 R&D projects performed within one private research center in machine tools industry. DEA was used for efficiency analysis. Input variables were R&D investment expense and man-month. Output variables were achievement rate on target development period and expected net sales within 5-years. Samples are divided into product development, Prior technology development, and control technology development. The key result is that Prior technology showed the lowest efficiency because of high uncertainty. It was so difficult to determine its goals and to make its specific plans. With respect to scale, the proportions of CRS(constant returns to scale) were 34.6%, 14.3% and 38.9% for product development, prior technology, control technology respectively. As for IRS(increase returns to scale), they were 53.8%, 85.7% and 38.9% for product development, prior technology, control technology respectively. As for DRS(decrease returns to scale) they were 11.5%, 0% and 22.2% for product development, prior technology, control technology respectively. On the whole, in this case, insufficient input was more problematic than excessive input, which means the lack of investment in R&D. Prior technology can be the source of the future competitiveness of companies. To operate inefficient DMU efficiently, the optimal input should be managed and it is derived from comparison with the reference group.

A Study on the Efficient Management Plan of Water Distribution Reservoirs Facility Using 3D Geospatial Information (3D 공간정보를 이용한 배수지시설물의 효율적인 관리방안에 관한 연구)

  • Jung, In Hun;Ro, Young Suk;Choi, Yun Soo;Woo, Sang Yoon;Kim, Chong Mun
    • Spatial Information Research
    • /
    • v.20 no.6
    • /
    • pp.109-118
    • /
    • 2012
  • Recent increasement of metropolitan infrastructure due to rapid expansion and development of urban areas which caused complexity and diversification of management system demands higher cost and effort to manage and maintain the facilities. The reason why it requires continuous and systematic management by national government is that the infrastructure facilities takes important role as it is directly related to public's living. Thus this study suggests an efficient management plan for increasement of work efficiency, cost reduction, and time saving by introducing 3D geospatial information system for water distribution reservoirs which is managed by the Office of Waterworks Seoul Metropolitan Government. This study evaluates and quantifies the range of work improvement using the 3D GIS technology through carrying out a survey targeting people in charge of the Office of Waterworks Seoul Metropolitan Government and other 8 offices. From the result of the research, applying the 3D-GIS improves by 90.32%, 93.55%, and 91.61% in the area of work efficiency, cost reduction, and time saving respectively. Consequently, using 3D GIS in future management of infrastructure could be used as a way of producing base data which supports administrative decision making through statistical and case analysis based on continuous data management. Also it would contribute to improving work efficiency by improving management system through preventing data omission.

A Study for Efficiency Improvement of Feedforward Power Amplifier by Using Doherty Amplifier (Doherty증폭기를 이용한 Feedforward전력 증폭기의 효율 개선에 관한 연구)

  • Lee Taek-Ho;Jung Sung-Chan;Park Cheon-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1059-1066
    • /
    • 2005
  • This paper reports an application of Doherty amplifier for efficiency improvement of feedforward power amplifier(FPA). For performance analysis, we measured 15 W average output power using WCDMA 4FA input signal with a center frequency 2.14 GHz. The applied Doherty amplifier presents the characteristics of high efficiency and low linearity in comparison to the class AB amplifier, and it was used as main amplifier of FPA fir efficiency improvement. To analyze the change of characteristic, tow Doherty amplifiers whose linearity and efficiency are different were applied. The applied FPAs are improved about $2\%$ or more performance in efficiency, but decreased in linearity on 15 W average output power. We additionally modified the coupling factor(CF) of the error loop and the error amplifier capacity for linearity improvement. Aa a result, the efficiency improvement and high linearity resulted from the change of CF and error amplifier capacity. However, we think if the linearity of Doherty amplifier were more than 35 dBc, the FPA would improve the performance about $2\%$ or more efficiency and maintain enough linearity.

Demonstration Study of Half-Saturated Bio-filter Wetland with Recirculation Pump for Road Stormwater (반포화 순환 여과식 인공습지에 의한 도로 강우유출수의 실증처리 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2017
  • In this study, field-scale half-saturated bio-filter wetland equipped with recirculation system was operated with stormwater from the paved road, and its operational performance and functions of LID-BMP were analyzed and compared with other facilities. The reduction of TSS, COD, TN, and TP were 92%, 63%, 36%, and 75%, respectively. Comparison of the reduction efficiency were carried out with respect to ratio between surface and catchment areas(SA/CA). In addition, this LID-BMP facility can reduce about 70% of pollutant by treating only 18% of total rainfall runoff. The results show that LID used for this study gave similar efficiency although its ratio was smaller. In addition, comparison study was made between synthetic fiber as a filter media and organic media, which shows that there was not any significant difference between, TSS and TP reduction, but there were large difference in COD and TN removal due to the presence and absence of release of organic carbon. Meanwhile, wetland system in this study equipped with a first-flush capture gave a higher stability in terms of treatment performance.

Efficient Privacy-Preserving Duplicate Elimination in Edge Computing Environment Based on Trusted Execution Environment (신뢰실행환경기반 엣지컴퓨팅 환경에서의 암호문에 대한 효율적 프라이버시 보존 데이터 중복제거)

  • Koo, Dongyoung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.305-316
    • /
    • 2022
  • With the flood of digital data owing to the Internet of Things and big data, cloud service providers that process and store vast amount of data from multiple users can apply duplicate data elimination technique for efficient data management. The user experience can be improved as the notion of edge computing paradigm is introduced as an extension of the cloud computing to improve problems such as network congestion to a central cloud server and reduced computational efficiency. However, the addition of a new edge device that is not entirely reliable in the edge computing may cause increase in the computational complexity for additional cryptographic operations to preserve data privacy in duplicate identification and elimination process. In this paper, we propose an efficiency-improved duplicate data elimination protocol while preserving data privacy with an optimized user-edge-cloud communication framework by utilizing a trusted execution environment. Direct sharing of secret information between the user and the central cloud server can minimize the computational complexity in edge devices and enables the use of efficient encryption algorithms at the side of cloud service providers. Users also improve the user experience by offloading data to edge devices, enabling duplicate elimination and independent activity. Through experiments, efficiency of the proposed scheme has been analyzed such as up to 78x improvements in computation during data outsourcing process compared to the previous study which does not exploit trusted execution environment in edge computing architecture.

A Study on the Efficiency of Children's Shelter in Korea using DEA Analysis Method

  • Jeong, Seong-Bae;Joo, Mi-yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.207-217
    • /
    • 2020
  • The purpose of this study is to analyze the efficiency of Korean child welfare facilities using the DEA analysis method and to present policies. The input variables for the analysis of this data were the number of employees, the number of facilities, and the number of gardens, and the output variables were the current sources. The results of the study are as follows. As a result of CCR analysis, inefficient facilities were found to be temporary protection facilities and comprehensive facilities. As a result of BCC analysis, inefficient facilities were identified as temporary protection facilities. As a result of SE analysis, inefficient facilities were found to be temporary protection facilities. The suggestion is as follows. First, adjustment of the capacity of temporary protection facilities is required. Second, it is necessary to strengthen the professionalism of workers in child welfare facilities. Third, strengthen the expertise of the child welfare facility manager.

ACP 핫셀의 방사선안전관리 시스템

  • 국동학;정원명;구정회;조일제;이은표;유길성
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.349-349
    • /
    • 2004
  • 차세대관리 종합공정(Advanced spent fuel Conditioning Process)은 사용후핵연료의 안전하고 효율적인 관리를 위하여 제시된 건식처리공정으로 사용후핵연료를 금속으로 전환하고, 고발열성 핵종(Cs, Sr)을 효율적으로 제거하여 사용후핵연료의 부피, 발열량 및 방사선의 세기를 최대 1/4까지 감소시키고, 처분용기의 소요량과 처분장의 소요면적을 1/2 이상으로 축소함으로서 처분 안전성과 경제성을 높일 수 있는 장점으로 인해 연구개발 중에 있으며, 이의 실증시험 수행을 위하여 ${\alpha}-{\gamma}$ type의 핫셀을 건설 중에 있다.(중략)

  • PDF

Dehumidification characterization of metal-silicate impregnated in ceramic sheet (Ceramic sheet에 함침된 metal-silicate의 제습특성)

  • 이창모;유윤종;김홍수;김준수;김시경;안영수;양오봉
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.167-172
    • /
    • 2002
  • 근년 들어 냉난방 효율의 향상과 에너지의 효율적인 이용 측면에서 건물의 밀폐성이 증가함과 동시에 쾌적한 주거환경 및 작업 환경을 위해 실내 환경 조건의 조절에 대한 관심이 높아짐에 따라 온도와 습도 조절의 필요성이 증대되고 있다. 쾌적한 환경을 위해 은도도 중요한 요소 중 하나지만 온도보다 습도에 의한 유해성이 더 크게 작용하기 때문에 습도 조절에 대한 필요성이 증대되고 있다.(중략)

  • PDF

Wired and Wireless Co­existant Networks Reliable Multicast Protocol (유무선 망에서의 신뢰적 멀티캐스트 프로토콜)

  • 권영호;안상현
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10c
    • /
    • pp.688-690
    • /
    • 2003
  • 유무선이 혼합된 망에 적용할 수 있는 신뢰적 멀티캐스트를 지원하기 위해서는 피드백 포구, 재전송 노출등의 문제를 해결하여 효율성과 확장성을 보장해야한다. 이를 위해서 유선망과 무선망의 특성을 함께 고려한 적절한 방법이 필요하였다. 본 논문에서는 유선 망에서는 신뢰성을 보장하기 위해 NACK 기반의 신뢰성 전송기법을 사용하고, 무선 망에서는 ACK와 NAK를 병행하는 방법으로 제어 패킷의 수와 복구시간을 줄여 효율적인 신뢰적 멀티캐스트 서비스를 지원하도록 하였다.

  • PDF

Implementation of the Enhanced E-Catalog System for the efficiency of the B2B e-marketplace (B2B e-Marketplace 효율성을 위한 차세대 E-Catalog 시스템 개발)

  • 최옥경;한상용
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10e
    • /
    • pp.73-75
    • /
    • 2002
  • 본 논문은 B2B 사이에 이루어지는 e-Marketplace를 효율적으로 운영하기 위해 카탈로그 문서의 표준화와 네트워크 구조의 검색 시스템을 제공한 E-Catalog 시스템을 개발하여 상거래의 상호 이질적인 카탈로그의 정보에 따른 상호 운영성 문제점을 해결하고 전체상품에 대한 View 정보, 실시간 업데이트 및 유연성을 제공하고자 한다

  • PDF