• Title/Summary/Keyword: 획득시간감소

Search Result 296, Processing Time 0.019 seconds

Architecture Design of PN Code Acquisition for MC-CDMA Systems (MC-CDMA 시스템용 PN 부호 동기획득 구조의 구현)

  • 노정민;이성주;김재석
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.2
    • /
    • pp.117-125
    • /
    • 2003
  • In this paper, we propose a new code acquisition architecture having the features of low complexity and high speed for the MC-CDMA system. The newly designed searching finger has function of the searcher as well as the finger. The searching finger tests the PN code Phase as the searcher during the initial acquisition, and as the finger after the initial acquisition. The proposed system has reduced the average acquisition time of the PN codes to $T_{acq}$/19 in the 20MHz MC-CDMA system with 75% reduction of H/W complexity.y.

Effect of Caffeine and Heparine on Acrosome Reaction and Protein Pattern of Korean Native Cattle Sperm In Vitro (카페인과 헤파린 처리가 한우정자의 첨체반응과 단백질상에 미치는 영향)

  • 윤종택;한기영;정영채;김창근;전광주
    • Journal of Embryo Transfer
    • /
    • v.11 no.3
    • /
    • pp.317-321
    • /
    • 1996
  • 본 연구는 수정능획득유기물질로 알려진 카페인 헤파린을 병행처리하여 한우 정자의 첨체 반응율과 생존율을 알아보고 수정능획득과정 중에 단백질의 변화상을 전기영동방법으로 조사하였다. 동결융해후 정자의 생존율은 90%이상이었으나 전배양처리후 0.5시간에 70%로 감소하고 2시간 이후에는 35%로 감소하였다. 정자의 첨체반응율은 동결융해후 정상정자가 85.7%였으나 전배양시간에 따라 53.4%에서 14.3%로 감소하였다. 동결융해후 첨체가 소실된 생존정자는 9.4%였으나 전배양시간에 따라 17.2%에서 46.8%로 증가하였다. 원정액에서는 분자량 20,000정도에서 동결융해후 전자보다 특이적으로 많은 단백질량을 나타내었으나 동결융해 후 정자를 0.5에서 2.0시간으로 전배양하였을 때 전배양시간에 따른 단백질상의 변화는 대조구와 큰 차이가 없었다.

  • PDF

A Effectiveness of Multi-Transmit Parallel Technique on Magnetic Resonance Imaging of FOV Less Than 26cm (자기공명영상검사 시 26cm 이하 영상영역의 Multi-Transmit 기법의 유용성)

  • Son, Soon-Yong;Choi, Kwan-Woo;Park, Kyeong-Jin;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.429-435
    • /
    • 2015
  • The purpose of this study was to prospectively estimate the effectiveness of multi-transmit parallel technique in reduced FOV(Field of View) less than 26 cm. Homogeneity, SNR(signal to noise ratio) and acquisition time were measured and compared by setting FOV less than 26cm on the T1 and T2 weighted images using ACR phantom. The multi-transmit parallel technique resulted in significantly faster image acquisition by 46.8 % in T1 weighted images and 18.9% in T2 weighted images. The homogeneity and SNR values had no significant difference between pre and post application of the multi-transmit parallel technique. In conclusion, this study demonstrates the feasibility of multi-transmit parallel technique in FOV less than 26cm with a rapid acquisition and maintained image quality.

동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.103-103
    • /
    • 2002
  • 목적:자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다 .관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 현관 밖에서의 Gd농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500 mM Gd-DTPA 2 ml를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_1$/$T_{2}^{*}$ 감소 효과를 구분하여 구한 $\DeltaR_1$, $\DeltaR_2$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

동시획득 $T_{1}{/}T_{2}^{*}$강조 경사 자장 펄스열을 사용한 관류량과 투과도 측정

  • 김은주;김대홍;이희조;허용민;이상훈;이삼현;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.127-127
    • /
    • 2002
  • 목적: 자화율 대조법을 사용한 관류 영상에서 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사 자장 펄스열을 사용하여 Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하여 종양의 치료 효과, 판정에 중요한 기준을 제시할 수 있는 정확한 관류 정보를 얻고자 한다. 대상 및 방법: Gd-DTPA에 의한 $T_{1}{/}T_{2}^{*}$ 감소 효과를 동시에 획득하기 위하여 기존의 이중 경사자장 펄스열을 수정, 동시획득 $T_{1}{/}T_{2}^{*}$ 강조 경사자장 펄스열을 개발하였고, 시간 해상도를 높이기 위하여 key-hole 방법을 사용하였다. 고정 phantom으로 Sephadex를 다양한 농도의 Gd-DTPA 용액에 swelling하여 사용하였고, 관류 phantom으로는 Sephadex와 Dialyzer를 사용하였다. Sephadex는 swelling 하였을 때 $T_1$, $T_2$값이 생체 조직의 값과 비슷하고, 물을 관류시킬 수 있어 생체 모형에 적합한 phantom이다. 관류 phantom은 정량 펌프에 연결하여 사용하였다. Sephadex 관류 phantom에서는 분당 약 4$m\ell$ 속도로 관류시키면서 25 mM Gd-DTPA을 0.1$m\ell$ 일시 주입하여 관류 방향에 수직인 coronal 영상을 약 15분 동안 얻었다. 투과도를 구하기 위한 phantom으로는 hollow fiber type Dialyzer를 사용하였고, in vivo에서 1차 관류 이후에 혈관 밖에서의 Gd 농도가 높고 혈관 내부의 농도가 낮은 상태를 만들기 위하여 fiber 바깥쪽으로 500mM Gd-DTPA 2$m\ell$를 미리 넣어두고 fiber 내부로 이보다 낮은 농도의 Gd 용액을 관류시키면서 약 1시간동안 영상을 얻었다. 관류 영상에서 $T_{1}{/}T_{2}^{*}$ 감소 효과를 구분하여 구한 $\Delta{R}_{1}$, $\Delta{R}_{2}^{*}$ 곡선의 적분값으로부터 관류량을 구하고, 2 구획 모델을 적용하여 투과도를 구했다.

  • PDF

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

An Approach to Acquire SIP Location Information for End-to-End Mobility Support Based on mSCTP (mSCTP 기반 종단 간 이동성 지원을 위한 SIP 위치정보 획득방안)

  • Chang Moon-Jeong;Lee Mee-Jeong
    • The KIPS Transactions:PartC
    • /
    • v.13C no.4 s.107
    • /
    • pp.461-470
    • /
    • 2006
  • Recently mobile Stream Control Transmission Protocol (mSCTP) has been proposed as a transport layer approach for supporting mobility. When a mobile terminal (MT) is not located in the home network. a terminal that wishes to communicate with the MT is not able to establish mSCTP association to the MT, since mSCTP does not include the location management mechanism. In order to solve this problem. an interworking approach using the Session Initiation Protocol (SIP) INVITE method has been proposed. However, this approach has shown subsequent delay in acquiring the current location information of the MT when initiating mSCTP association establishment. In this paper, we propose new SIP methods and an approach that minimizes the address acquisition delay (AAD) by utilizing those SIP methods. Mathematical analysis and simulation results show that the proposed approach is more efficient than the previous approach in terms of AAD in all kinds of SIP environments.

Implementation of Regional Cerebral Blood Volume Map Using Perfusion Magnetic Resonance Image Process Algorithm (관류자기공명 영상처리 알고리즘을 이용한 대뇌 혈류량 맵의 구현)

  • Park Byung-Rae
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.296-304
    • /
    • 2005
  • Quantitative analysis compare to dynamic characteristic change of the regional cerebral blood volume(rCBV) after development of cerebral fat embolism in cats using perfusion magnetic resonance(MR) Imaging. Twenty cats were used. Linoleic acid (n=11) were injected into the internal carotid artery using microcatheter through the transfemoral approach. Polyvinyl alcohol (Ivalon) (n=9) was injected as a control group. Perfusion MR images were obtained at 30 minutes and 2 hours after embolization, based on T2 and diffusion-weighted images. The data was time-to-signal intensity curve and ${\Delta}R_2^*$ curve were obtained continuously with the aid of home-maid image process algorithm and IDL(interactive data Banguage, USA) softwares. The ratios of rCBV increased significantly at 2 hours compared with those of 30 minutes (P<0.005). In conclusion, cerebral blood flow decreased in cerebral fat embolism immediately after embolization and recovered remarkably in time course. It is thought that clinically informations to dynamic characteristic change of the cerebral hemodynamics to the early finding in cerebral infarction by diffusion weighted imaging(DWI) and perfusion weighted imaging(PWI).

  • PDF

Spatio-Temporal Searcher Structure of Adaptive Array Antenna System for 3rd Generation, W-CDMA Systems (3세대 W-CDMA 시스템에 적용 가능한 적응형 어레이 안테나 시스템을 위한 공-시간 탐색기 구조)

  • 김정호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10A
    • /
    • pp.775-779
    • /
    • 2003
  • A spatio-temporal searcher structure for 3rd generation W-CDMA systems is proposed to enhance the detection capability of the multi-path searcher for the desired signal. This searcher employs the spatio-temporal signal structure to search for newly emerging multipath signals. The proposed multi-path searcher provides better detection capability andthus reduces the mean acquisition time. The detection and false alarm probabilities of new and conventional schemes are calculated and numerical examples of mean acquisition time are given thereafter.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.