• Title/Summary/Keyword: 회전효과

Search Result 1,180, Processing Time 0.025 seconds

Development of Computation Model for Traffic Accidents Risk Index - Focusing on Intersection in Chuncheon City - (교통사고 위험도 지수 산정 모델 개발 - 춘천시 교차로를 중심으로 -)

  • Shim, Kywan-Bho;Hwang, Kyung-Soo
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.61-74
    • /
    • 2009
  • Traffic accident risk index Computation model's development apply traffic level of significance about area of road user group, road and street network area, population group etc.. through numerical formula or model by countermeasure to reduce the occurrence rate of traffic accidents. Is real condition that is taking advantage of risk by tangent section through estimation model and by method to choose improvement way to intersection from outside the country, and is utilizing being applied in part business in domestic. However, question is brought in the accuracy being utilizing changing some to take external model in domestic real condition than individual development of model. Therefore, selection intersection estimation element through traffic accidents occurrence present condition, geometry structure, control way, traffic volume, turning traffic volume etc. in 96 intersections in this research, and select final variable through correlation analysis of abstracted estimation elements. Developed intersection design model taking advantage of signal type, numeric of lane, intersection type, analysis of variance techniques through ANOVA analysis of three variables of intersection form with selected variable lastly, in signal crossing through three class intersection, distinction variable choice risk in model, no-signal crossing risk distinction analysis model and so on develop.

  • PDF

Rheological Characteristics and Molecular Weight of Ammonium-Sulfate Fractions of Tara Gum (염석법에 의한 타라검 분획들의 분자량 및 리올로지 특성)

  • Kim, Kyeong-Yee
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.293-298
    • /
    • 2015
  • This study aimed at characterizing the rheological properties and molecular weight of tara gum fractionated with ammonium sulfate. Tara gum was separated into six fractions (F1-F6) at different concentrations of ammonium sulfate, ranging from 12.21 to 28.67% (w/w). The yield of the tara gum fractions ranged between 4.98 and 17.47%, and their intrinsic viscosity ranged from 9.38 to 12.44 dL/g. The highest values of Huggins coefficient (k') and viscosity-molecular mass were observed in fraction F3. The shear viscosity of the tara gum fractions was measured by a cone-plate viscometer, clearly showing shear thinning behavior. Size-exclusion chromatography results showed that the molecular weight ranged between 635.42 and 776.71 kg/mol, and the F3 fraction exhibited higher values of molecular weight.

Isolation and Purification of Berberine in Cortex Phellodendri by Centrifugal Partition Chromatography (Centrifugal Partition Chromatography에 의한 황백으로부터 Berberine의 분리 및 정제)

  • Kim, Jung-Bae;Bang, Byung-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.3
    • /
    • pp.532-537
    • /
    • 2014
  • Cortex Phellodendri (CP) is derived from the dried bark of Phellodendron amurense. It has been widely used as a drug in traditional Korea medicine for treating diarrhea, jaundice, swelling pains in the knees and feet, urinary tract infections, and infections of the body surface. Many analytical methods have been used to study oriental herbal medicines, such as thin-layer chromatography, column liquid chromatography, and high performance liquid chromatography (HPLC). In this study, preparative centrifugal partition chromatography (CPC) was successfully carried out in order to separate pure compounds from a CP methanol extract. The optimum two-phase CPC solvent system was composed of n-butanol: acetic acid: water (4:1:5 v/v/v). The flow rate of the mobile phase was 3 mL/min in ascending mode with rotation at 1,000 rpm. The CPC-separated fraction and purification procedures were carried out by preparatory HPLC. The $^1H$ NMR spectrum revealed that the resonances at ${\delta}$ 4.10 and 4.20 ppm corresponded to three protons ($-OCH_3$), whereas those at ${\delta}$ 6.10 ppm corresponded to two protons ($-OCH_2O-$). Further, two aromatic protons (H-11 and H-12) conveys a doublet-doublet pattern. The H-11 doublet and H-12 doublet appear at ${\delta}$ 7.98 and 8.11, respectively. The $^{13}C$ NMR. spectrum showed a tetrasubstituted with a methylenedioxy group at C2 and C3, and two methoxy groups at C9 and C10. The chemical structure of the berberine was identified by $^1H$, $^{13}C$-nuclear magnetic resonance and electrospray ionization-mass spectroscopy spectral data analysis.

A STUDY OF THE ANTI-ROTATING INNER POST SCREW SYSTEM AS A MEANS OF PREVENTING ABUTMENT SCREW LOOSENING (회전 방지용 Post Screw 시스템의 임플랜트 지대나사풀림 방지효과에 관한 연구)

  • Kim Jong-Hui;Lim Ju-Hwan;Cho In-Ho;Lee Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.671-683
    • /
    • 2005
  • Statement of problem: The most commonly reported problem associated with dental implant restoration is the loosening of the screws. Purpose: This study compared the efficacy of an implant system incorporating an anti-rotational locking sleeve(Anti-Rotating Inner Post Screw System(ARIPS-system)) with other, traditional implant systems as a means of minimizing vibration loosening. Materials and methods: Three implant systems were examined; the conventional external hex type, the ARIPS-system, and the internal taper type implant system 30 specimens(10 samples per group)were fabricated and each abutment screw was secured to the implant future with 32Ncm of torque force and loosening torque was measured using a Torque Gauge. The procedure was repeated 3 times, recording initial loosening torque each time. The re-tightened abutment screw was subjected to a cyclic load having a maximum forte of 200N and minimum of 20N at 2Hz over a period of 12,600 cycles. after which the loosening torque was measured. Measured values were calaulated for statistical analysis. Analysis of measured value was performed by 3 methods: (i) as a percentage average of the initial 3 loosening-torque values(initial loosening value) to the tightening torque of 32Ncm, (ii) as a percentage of the loosening torque value after a load of 200N(experimental value) to the initial loosening value, and (iii) as a percentage of the experimental value to the 32Ncm of tightening torque. The analyses shows the amount of initial loosening at the screw, loosening by repetitive load and the the final loosening value. Results: The results of this study were as follows (1) Percentage of initial loosening value to tightening-torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of external hex, ARIPS-system and internal taper. Value of internal taper showed significant difference with those of external hex and ARIPS-system (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of external hex, ARIPS-system and internal taper and all values between each groups showed statistical significance (p<0.05). Conclusion: The results of the analysis of the final loosening level value, which are closely correlated to clinical use, show that the ARIPS-system can be a useful means of minimizing abutment screw loosening when compared to the external hex type system. Although further clinical studies need to be made, the ARIPS-system should be considered to maximize the long-term success of the implant prosthesis.

Design Optimization of Two-Way Pump Casing through Flow Analysis (양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계)

  • Kim, Dong-Hwi;Noh, Yoojeong;Lim, O-Kaung;Choi, Eun-Ho;Choi, Ju Yong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • A two-way pump can reduce costs by draining and circulating water out and into the drum of the washing machine using a single motor whereas a conventional one-way pump uses two motors for doing the same function. However, when the water is drained through the drainage outlet in the two-way pump casing, a backward or inhalation flow occurs and the water flows to the circulation outlet. Likewise, when the water is circulated, the backward flow or inhalation makes the water flow to the drainage outlet. In this study, design optimization of the two-way pump casing is performed to maximize its performance while improving backward flow and inhalation occurring inside of the pump casing. For this, design variables of the pump casing that mainly affect the performance of the pump such as flow rate and torque of the motor were selected through the analysis of mean. Using response surface models for the performances, the ratio of the flow rate to the torque was maximized with satisfying the constraints for the back flow and inhalation through design optimization.

Effects of Activin on Testosterone-primed Immature Rainbow Trout Gonadotropin Release in vitro (Testosterone 처리한 미성숙 무지개송어 뇌하수체의 세포배양계에서 생식소자극초르몬 분비에 대한 Activin의 효과)

  • KIM Dae-Jung;HAN Chang-Hee;AIDA Katsumi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.2
    • /
    • pp.204-210
    • /
    • 1999
  • The present studies were conducted to evaluate the effects of activin-A on gonadotropins (GTHs) release in testosterone-treated immature rainbow trout Oncorhpynchus mykiss. The administration of testosterone elevated pituitary level of GTH II but not of GTH I. In this study using primary cultures of dispersed pituitary cells in static incubation, dose-dependent increases in GTH II release was observed in the activin-treated group at day 3 of incubation (long-term incubation), but not at day 1 of incubation (short-term incubation). Dopamine, a potent inhibitor of gonadotropin-releasing hormone (GnRH)-stimulated GTH II release in rainbow trout, was only partially effective in decreasing actvin-induced GTH II release. Furthermore, salmon GnRH (sGnRH)-stimulated GTH II release was not potentiated by the pretreatment with activin. However, the control mechanisms of GTH I release by activin and other hormones were not observed in the all tested experiments. The results of these studies support the contention that in contrast with the usual stimulatory effects of activin on GTH release in mammals, activin exerts long-term stimulatory actions on GTH II release in rainbow trout. The control mechanism of GTH I release, however, is a question that remains to be elucidated.

  • PDF

The current status in the silicon crystal growth technology for solar cells (태양전지용 규소 결정 성장 기술 개발의 현황)

  • Lee, A-Young;Lee, Dong-Gue;Kim, Young-Kwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.24 no.2
    • /
    • pp.47-53
    • /
    • 2014
  • Three kinds of crystalline silicon have been used for the solar cell grade. First of all, single crystalline silicon is the main subject to enhance the production yield. Most of the efforts are focused on the control of the melt-crystal interface shape affected by the crystal-crucible rotation rate. The main subject in the multi-crystalline silicon ingot is the contamination control. Faster Ar gas flow above the melt surface will lower the carbon contamination in the crystal. And also, twin boundary electrically inactive is found to be more effective than grain boundary for the improvement of the MCLT. In the case of mono-like silicon material, propagation of the multi-crystalline silicon growing from the inner side crucible is the problem lowering the portion of the single crystalline part at the center of the ingot. Crystal growing apparatus giving higher cooling rate at the bottom and lower cooling rate at the side crucible was suggested as the optimum solution obtaining higher quality of the mono-like silicon ingot. Proper application of the seeds at the bottom of the crucible would be one of the solutions.

Survey study of powered toothbrush with guiding device for oral hygiene improvement (유도장치가 부가된 진동회전방식 전동칫솔의 구강건강증진효과에 대한 조사연구)

  • Park, Yun-Soo;Lee, Chul-Woo;Hahm, Byoung-Do;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Gu, Young;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.4
    • /
    • pp.407-412
    • /
    • 2009
  • Purpose: This study was performed to evaluate the effect of powered toothbrush with a wireless remote display on the subjective and objective oral hygiene improvement. Methods: One hundred and fifteen subjects in healthy or mild gingivitis status between the ages of 20 and 90 were recruited and reviewed for study inclusion criteria. At first visit, 115 pre-screened subjects filled in the questionnaire form which consisted of demographic factors, behavioral factors (smoking, alcohol consumption), toothbrushing habits (brushing time and frequency), self-reported oral health status, and self-satisfaction. Baseline clinical indices (Plaque index, Gingival index) were also recorded by a periodontist. Subjects were instructed how to use powered toothbrush with a wireless remote display, and were provided with it. Thirty days after first visit, 90 subjects returned for the second assessment by self-reported questionnaire form and professional clinical checkup. Statistical analysis was performed using paired t-test for the difference between baseline and second visit data. The relationship among variables was examined with chi-square test and Fisher' s exact test. Results: Significant differences were not found on self-reported satisfaction related with sex, smoking, alcohol consumption (P<0.05). Self-reported tooth brushing habit was improved in the aspect of brushing time and frequency. Significant differences were found on the self-reported oral health status, self-satisfaction, and clinical indices between the baseline and second visit data (P<0.01). Clinical indices were significantly reduced after using powered toothbrush with a wireless remote display (P<0.01). No adverse reactions were reported during the study period. Conclusions: Powered toothbrush with a wireless remote display successfully promoted oral hygiene from the subjective and objective viewpoint after 30 days of home usage.

A Study on the Recycling of Waste in the Limestone Mine (석탄석광산 폐석의 재활용 연구)

  • Chae, Young-Bae;Joeng, Soo-Bok;Koh, Won-Sik;Park, Je-Shin;Yang, Shi-Young
    • Resources Recycling
    • /
    • v.5 no.4
    • /
    • pp.25-31
    • /
    • 1996
  • The wastes ot l~mestone mines have been cause the extrar.ngance of the valuablz m e r a l s and destruction of the environment. Therefore, \\-c tied ta separation of calcite illid clay from the limestone mine wastes by rotntmg screen type separator made by ourselves in order to recyding such us a raw matcriala for cement maimfacture. CaO amtents in the separated coarse products increased from 37.36 wt% to 42+2 wt% at the condition ihat water content in wastes was lzss than 6wt%, the passing time of specimen in &amber was 15 semnds and the rotation speed was 6OLl qm. A process in order lo separate wastes effectively to having wide range aI part~dcs ize was cstablishcd and CaO contents of coarsc products through this process increased to 46.85 wt%. Tbis rcsult is insuEiicient to directly rcusing as a raw malerials for cement. However, it is supposed that coarse products would be able to be reuscd as a raw materials uf cement, if only it rs sclected dolomite in wastes, and really it may be possible in fields Othenvise, undcrsize products(less than 20 mm) would be able to recycling as a raw of cement bccause chcmicrl campasitions of thosc is kept almost constant v&cs on the overall process.

  • PDF

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF