• Title/Summary/Keyword: 회전운동 범위

Search Result 131, Processing Time 0.027 seconds

Measurement of shoulder motion fraction and motion ratio (견관절 운동 분율의 측정)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2006
  • Purpose : This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. Materials and Methods : We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR(computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was $15^{\circ},\;19^{\circ},\;22^{\circ}$ to the cephald for the parallel scapular spine, and the tilting of torso was external oblique $40^{\circ},\;36^{\circ},\;22^{\circ}$ for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age(20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, $90^{\circ}$ and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. Results : While the arm elevation was $90^{\circ}$, the shoulder motion fraction was 1.22(M), 1.70(W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84, and left was 1.57, 1.32. In right dominant arm(78%), $90^{\circ} and Full motion fraction was 1.58, 1.43, in left(22%) 1.82, 1.94. In generation 20, $90^{\circ} and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28, 60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. Conclusion : The criterior of motion fraction was useful reference for clinical dignosis the shoulder instability.

  • PDF

Arthroscopic Treatment of Calcific Tendinitis of the Rotator Cuff (회전근 개 석회화 건염의 관절경적 치료)

  • Lee Kwang-Won;Ryu Chang-Soo;Kim Ha-Yong;Kim Byung-Sung;Choy Won-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.1
    • /
    • pp.27-31
    • /
    • 2001
  • Purpose : The purpose of this study was to evaluate results of the arthroscopic treatment of calcific tendinitis of the shoulder resistant to conservative treatment. Materials and Methods : From March, 1996 to June, 1998, fourteen patients underwent shoulder arthroscopy to treat resistant calcific tendinitis of the rotator cuff despite conservative treatment for more than 6 months. Calcium deposits were localized to the supraspinatus tendon only in eleven patients, the supraspinatus and infraspinatus tendon in two patients, and to the supraspinatus and subscapularis tendon in one patient. Each shoulder was evaluated with UCLA shoulder rating scale and Constant-Murley score Results : The Constant-Murley pain score improved from average score 3.2 before surgery to average score 8.3 after surgery, and the UCLA functional average score improved from 4.5 preoperatively to 8.3 postoperatively. Preoperative ROM averaged $110^{\circ}$ of flexion, $45^{\circ}$ of external rotation, $90^{\circ}$ of abduction, and internal rotation with the thumb reaching to the spinous process of the third lumbar vertebra, but postoperative range of motion averages improved as follows: $170^{\circ}$ or flexion, $50^{\circ}$ of external rotation, $140^{\circ}$ abduction, and internal rotation with the spinous process of the twelveth thoracic vertebra. Overall 3 patients were rated excellentm 9 were good, 2 were fair. Conclusion : Shoulder arthroscopy is an effective treatment in patients with refractory calcific tendinitis.

  • PDF

Debridement or Tuberoplasty for Massive Rotator Cuff Tear (광범위 회전근 개 파열에 대한 변연절제술 및 결절성형술)

  • Cho, Nam-Su;Oh, Hyun-Sup;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.146-152
    • /
    • 2010
  • Purpose: The purpose of this article was to review the effectiveness of arthroscopic debridement and tuberoplasty, and to evaluate the clinical and radiologic results of our series for irreparable massive rotator cuff tears in the elderly. Materials and Methods: We reviewed articles that focused on the treatment options and decision making for irreparable massive rotator cuff tears. In particular, we summarized the reported results of arthroscopic debridement and tuberoplasty for irreparable massive rotator cuff tears in the elderly. Among consecutive patients who had arthroscopic tuberoplasty for irreparable massive rotator cuff tears in our series, thirty-two patients available for clinical and radiological evaluation at a mean follow-up of 29 months (range, 13-52 months) were enrolled and reviewed for the analysis. Results: At the last follow-up, the range of active forward flexion increased significantly with excellent pain relief and improvement in the ability to perform the activities of daily living. However, the group with less than 2 mm in preoperative acromiohumeral distance showed inferior postoperative results. Conclusion: Arthroscopic tuberoplasty may be an alternative option in irreparable massive rotator cuff tears for pain relief and improvement of range of motion. However, good results can not be expected if the acromiohumeral distance is less than 2 mm preoperatively and decreases postoperatively, or when the preoperative range of motion is less than $90^{\circ}$ on flexion and abduction.

The Effects of Video Exercise Education on Range of Motion, Pain and Quality of Life for Shoulder-joint Patients (동영상 운동교육이 견관절 환자의 관절가동범위, 통증 및 삶의 질에 미치는 효과)

  • Lim, Semi;Yeom, Young-Ran;Lee, Jeong-Hwa
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.9
    • /
    • pp.43-52
    • /
    • 2020
  • The purpose of this study is to develop video exercise education for patients with shoulder-joint and evaluate the effects on range of motion, pain and quality of life. This study was conducted in 30 experimental groups and 26 control groups among shoulder-joint patients who were admitted to orthopedic outpatient clinics at university hospitals in G city from January to June 2020. For data analysis, SPSS was used to analyze the general characteristics of the two groups and the pre-homogeneity test for the dependent variables by 𝑥2-test and t-test. As a result of the study, the subject's pre-post score change was found to have a significant difference in the degree of internal rotation of the range of motion and pain score, but there was no significant difference in the flexion, abduction degree of the range of motion and quality of life. In this study, clinical application of video education can be suggested as a way to improve nursing practice as it saves time spent on patient education of nurses not only in outpatients but also in wards.

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

Muscle Length and Shortening Velocity Changes during the Different Types of Vertical Jumps (수직점프 동작시 근육길이와 수축속도 변화)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.1
    • /
    • pp.161-172
    • /
    • 2004
  • 본 연구의 목적은 각기 다른 수직 점프 동작 시 근육의 길이와 근육의 수축속도 변화를 비교 분석하는데 있다. 피험자의 운동학적 변인들을 분석하기 위해 2대의 고감도 카메라를 (60 Hz, Panasonic AG455) 사용하여 점프 동작을 촬영하였다. 대퇴직근, 내측광근, 외측광근, 중간광근, 대퇴이두근(단두), 내측과 외측 비복근의 길이와 근수축 속도는 Brand et al. (1982)에 의해 제시되어진 하지근 기시 정지점의 3차원 좌표값과 동작분석을 통한 하지 분절간의 회전 및 변환행렬을 사용하여 측정되어졌다. 일반적인 근육 길이와 수축속도의 변화 형태는 각기 다른 점프간에 매우 유사한 형태를 보였다. 상승기 초기에 대퇴사두근의 길이가 최대인것으로 나타났으며, 이에 반해 대퇴이두근과 내외측 비복근은 공중 동작이 발생하는 시점에 근의 길이가 최대인 것으로 나타났다. 근육의 길이 변화 범위는 대퇴직근이 35.9에서 47.5 cm, 외측광근이 29.4에서 38.8 cm, 중간광근이 31.5에서 38.0 cm, 내측광근이 30.9에서 38.6 cm, 대퇴이두근이 21.3에서 39.1 cm, 외측비복근이 31.4에서 33.5 cm, 내측비복근이 30.5에서 33.2 cm인 것으로 나타났다. SQ와 CMJ에서는 대퇴사두근의 최대 단축성 수축 속도와 대퇴이두근과 내외측 비복근의 최대 신장성 수축이 공중동작이 발생하기 바로 전에 이루어졌다. 대퇴사두근의 최대 신장성 수축과 대퇴이두근과 내외측 비복근의 최대 단축성 수축은 일반적으로 피험자가 착지하는 순간에 발생되어졌다. 그러나 HJ와 DJ에서는 대퇴사두근의 최대 신장성 추축과 대퇴이두근과 내외측 비복근의 최대 신장성 수축이 하강기 초반에 발생되어졌다.

Knee Rehabilitation System through EMG Signal analysis and BLDC Motor Control (근전도 신호 분석 및 BLDC모터 제어를 통한 무릎재활시스템)

  • Kwon, Hyeong-Gi;Ko, Hyeong-Gyu;Song, Yoon-Oh;Son, Eui-Seong;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.1009-1018
    • /
    • 2019
  • This paper describes the design and implementation of a rehabilitation medical device based on a EMG measurement. Rehabilitation systems are controlled using BLDC motors and motor drives. The BLDC motor drive controls the operation and the speed controls the drive through the external servo motor. In addition, potentiometer coupled to the outside of the motor transmits information about the position of the load being rotated by the motor. The rehabilitation algorithm is controlled by limiting the maximum angle of 0 to 120 by utilizing the motor according to the user setting stage during the rehabilitation exercise. The walking algorithm compensates motor control for the low leg of the signal using the difference value of the signal obtained with the surface denser attached to both inner muscles. The motor and surface denser are utilized for the walk motion to control the maximum angle of 0 to 80.

Large Hill-Sachs Lesion Combined with a Rotator Cuff Tear in an Acute Traumatic Anterior Dislocation of the Shoulder in an Elderly Patient Treated with an Allogenic Iliac Tricortical Bone Graft (노인 환자의 급성 외상성 견관절 전방 탈구에서 회전근개 파열과 동반된 거대 Hill-Sachs 병변에 대해 간접 정복 및 지지대 목적의 동종 장골 삼중 피질골 이식을 통한 치료 1예)

  • Hyun, Yoonsuk;Lim, Jinkyu;Baek, Seung-Ha;Park, Jinho;Lee, Seung-Jin
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.188-192
    • /
    • 2020
  • An indirect reduction through the bicipital groove and allogenic iliac tricortical bone graft was performed as a treatment for a large Hill-Sachs lesion with a rotator cuff tear in an acute traumatic shoulder joint dislocation in an elderly patient. Six months after surgery, the rotator cuff healing and bone union were confirmed. The patient also showed satisfactory clinical results with 95 points of the American Shoulder and Elbow Surgeons (ASES) shoulder score and active range of motion with 155° flexion, 120° abduction, and 70° external rotation and 30° internal rotation at 90° abduction. The surgical method can be considered for a large Hill-Sachs lesion with rotator cuff tear in an acute traumatic shoulder joint dislocation in elderly patients.

Clinical Outcomes of Ultrasound-Guided Subacromial Bursal Steroid Injection in Shoulder Impingement Syndrome (견관절 충돌 증후군에서 초음파하 견봉하 점액낭내 스테로이드 국소 주사의 임상적 결과)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Bum-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • Purpose: We retrospectively studied the outcomes of the shoulder impingement syndrome for the treatment of the ultrasound-guided subacromial bursal steroid injection. Materials and Methods: Sixty-six shoulders of sixty-two patients with shoulder impingement syndrome treated from March, 2006 to April, 2009 were involved in this study. All cases underwent standardized, nonoperative treatment protocol consisting of 5~12 MHz high resolution ultrasound-guided local steroid injection into the subacromial bursa in modified Crass position. The shoulder range of motion, VAS score and impingement signs were evaluated during the initial and 1year visits. After injection, shoulder elevation exercise was encouraged. Statistical analysis with ANOVA model and Tukey's post-hoc test with the significance level at 5% were performed using SAS program. Results: All cases showed improved range of motion without limitation of shoulder function at immediate post-injection, 6-week, 3-month and 1year visits. The average VAS score at one year follow-up decreased to 2.85 from 6.47 before injection. In all cases the impingement signs became negative immediate after injection. However, 6 cases showed positive impingement signs after 6-week, which became negative after reinjection. The range of motion and VAS score were improved at one-year follow-up compared to initial visit (p<0.0001). No complication was noted at all follow-up period. Conclusion: Ultrasound-guided subacromial steroid injection alleviated the need of surgery, because it was successful in all our cases to improve pain and function of the shoulders until one year follow-up period.

  • PDF