• Title/Summary/Keyword: 회전변형

Search Result 629, Processing Time 0.024 seconds

Development of a Rotation Swab Pig Method for Cleaning Water Pipes (상수관의 세척을 위한 회전식 스왑피그 공법 개발)

  • Kicheol Lee;Jaeho Kim;Kisung Kim;Jeongjun Park
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Drinking water is an essential element to ensure the basic human right to live, and the quality of clean water must always be ensured. However, domestic water facilities, which were installed intensively in the early 2000s, are deteriorating. The accidents such as discoloration of water such as chromaticity and turbidity as well as leakage of substances frequently occur. However, since it is virtually impossible to replace all water pipes, the detailed standards for maintenance of water pipe network facilities established in 2021 require water pipe cleaning. The swab pig method, one of the water pipe cleaning methods, is a method of physically removing substances in pipes and is evaluated as having the highest cleaning efficiency. However, Swab is highly likely to be damaged or deformed during the cleaning process, and may even be lost. Therefore, in this study, the material of the pig was changed to a material with high compressibility, and it was made as close as possible to the inner wall of the water pipe. And, to maximize cleaning efficiency, a rotation swab pig with a rotation blade was developed. In addition, high-strength wire and winding equipment were additionally developed to eliminate the possibility of loss and to determine the location of the pig. The inlet and outlet are connected with wires, and after verifying the performance of each detailed technology, the technology was applied on a test bed with a 30m section. As a result of the application, the performance of the technology was verified by measuring the process time and evaluating applicability.

Clinical Outcomes of Ultrasound-Guided Subacromial Bursal Steroid Injection in Shoulder Impingement Syndrome (견관절 충돌 증후군에서 초음파하 견봉하 점액낭내 스테로이드 국소 주사의 임상적 결과)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Bum-Suk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • Purpose: We retrospectively studied the outcomes of the shoulder impingement syndrome for the treatment of the ultrasound-guided subacromial bursal steroid injection. Materials and Methods: Sixty-six shoulders of sixty-two patients with shoulder impingement syndrome treated from March, 2006 to April, 2009 were involved in this study. All cases underwent standardized, nonoperative treatment protocol consisting of 5~12 MHz high resolution ultrasound-guided local steroid injection into the subacromial bursa in modified Crass position. The shoulder range of motion, VAS score and impingement signs were evaluated during the initial and 1year visits. After injection, shoulder elevation exercise was encouraged. Statistical analysis with ANOVA model and Tukey's post-hoc test with the significance level at 5% were performed using SAS program. Results: All cases showed improved range of motion without limitation of shoulder function at immediate post-injection, 6-week, 3-month and 1year visits. The average VAS score at one year follow-up decreased to 2.85 from 6.47 before injection. In all cases the impingement signs became negative immediate after injection. However, 6 cases showed positive impingement signs after 6-week, which became negative after reinjection. The range of motion and VAS score were improved at one-year follow-up compared to initial visit (p<0.0001). No complication was noted at all follow-up period. Conclusion: Ultrasound-guided subacromial steroid injection alleviated the need of surgery, because it was successful in all our cases to improve pain and function of the shoulders until one year follow-up period.

  • PDF

Combined Reconstruction of Posterior Cruciate Ligament and Posterolateral Corner with a Fresh Frozen Achilles Tendon Allograft (한 개의 신선동결 동종아킬레스건을 이용한 후방십자인대 및 후외방구조의 동시 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Lee, Hyun-Joo;Ihn, Joo-Chul
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.102-108
    • /
    • 2009
  • Purpose: The purpose of this study is to report a result of the technique that reconstruct posterior cruciate ligament (PCL) and posterolateral corner (PLC) simultaneously using a fresh-frozen Achilles tendon allograft. Materials and Methods: Forty two patients (45 legs) underwent PCL and PLC reconstruction were included. There were 38 males and 4 females. Mean age was 39 years. Used graft was a fresh frozen Achilles tendon allograft, which was divided by two size, larger one (${\emptyset}$ 10 mm) for PCL reconstruction and smaller one (${\emptyset}$ 8 mm) for PLC reconstruction. Arthroscopic reconstruction of the PCL was performed using transtibial, single incision, and single bundle technique with 10mm fresh frozen Achilles allograft tendon first. After PCL reconstruction, reconstruction procedure for posterolateral instability was performed using modified figure of "8" technique using smaller gtaft. For clinical evaluation, range of motion, posterior drawer test, varus stress test, prone external rotation (dial) test, Lysholm score, Tegner activity scale and posterior stress radiograph were used. Mean follow up period was 25 months. Results: Preoperatively posterior drawer test was 5 cases in grade II and 40 cases in grade III posterior instability. At final follow-up 22 cases returned within normal condition, 18 cases grade I and 5 cases grade II posterior instability. Though all patients showed positive result over 10 degrees in dial and varus stress test preoperatively, but only 9 cases showed positive both test at final follow-up. The range of motion deficit over $10^{\circ}$ flexion was 3 cases. Lysholm score was improved from mean 50 preoperatively to mean 83(p<0.05) and Tegner activity scale improved from mean 2.1 preoperatively to mean 4.6(p<0.05). In posterior stress radiographs, posterior displacement was improve from mean 16mm preoperatively to 4.1mm after treatment(p<0.05). All patients had improved compared to their pre-operative status as measured by physical examination such as posterior drawer test, varus stress test, dial test. Conclusion: We had successful results by combined reconstruction of the PCL & PLC with a fresh frozen Achilles tendon allograft in patients with PCL and posterolateral rotatory instability at a time.

  • PDF

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

Study on the Neural Network for Handwritten Hangul Syllabic Character Recognition (수정된 Neocognitron을 사용한 필기체 한글인식)

  • 김은진;백종현
    • Korean Journal of Cognitive Science
    • /
    • v.3 no.1
    • /
    • pp.61-78
    • /
    • 1991
  • This paper descibes the study of application of a modified Neocognitron model with backward path for the recognition of Hangul(Korean) syllabic characters. In this original report, Fukushima demonstrated that Neocognitron can recognize hand written numerical characters of $19{\times}19$ size. This version accepts $61{\times}61$ images of handwritten Hangul syllabic characters or a part thereof with a mouse or with a scanner. It consists of an input layer and 3 pairs of Uc layers. The last Uc layer of this version, recognition layer, consists of 24 planes of $5{\times}5$ cells which tell us the identity of a grapheme receiving attention at one time and its relative position in the input layer respectively. It has been trained 10 simple vowel graphemes and 14 simple consonant graphemes and their spatial features. Some patterns which are not easily trained have been trained more extrensively. The trained nerwork which can classify indivisual graphemes with possible deformation, noise, size variance, transformation or retation wre then used to recongnize Korean syllabic characters using its selective attention mechanism for image segmentation task within a syllabic characters. On initial sample tests on input characters our model could recognize correctly up to 79%of the various test patterns of handwritten Korean syllabic charactes. The results of this study indeed show Neocognitron as a powerful model to reconginze deformed handwritten charavters with big size characters set via segmenting its input images as recognizable parts. The same approach may be applied to the recogition of chinese characters, which are much complex both in its structures and its graphemes. But processing time appears to be the bottleneck before it can be implemented. Special hardware such as neural chip appear to be an essestial prerquisite for the practical use of the model. Further work is required before enabling the model to recognize Korean syllabic characters consisting of complex vowels and complex consonants. Correct recognition of the neighboring area between two simple graphemes would become more critical for this task.

Development of Smart Packaging for Cream Type Cosmetic (크림 제형 화장품용 스마트 패키징 기술 개발)

  • Jeon, Sooyeon;Moon, Byounggeoun;Oh, Jaeyoung;Kang, Hosang;Jang, Geun;Lee, Kisung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.79-87
    • /
    • 2019
  • The degree of cosmetic's oxidation depends on the storage conditions and external conditions when using the product. The microbial contamination and oxygen exposure often results in the quality deterioration of cosmetics. In addition, the problem is that consumers often use cream-type cosmetics, which have short expiration period (6-12 months), even after the product is expired. When using the deteriorated cosmetics, it can be fatal to consumers' safety including some symptoms such as folliculitis, rashes, edema, and dermatitis. Therefore, it is necessary to develop sealed smart packaging for cosmetics to prevent the deterioration of cosmetics and improve consumer safety. In this study, we have developed smart packaging design for cosmetics that can measure the surrounding environment and expiration date for the cosmetics in the real time. In addition, the smart packaging includes sensor, which are linked to the mobile application. Users can find out the measurement results through the application. Also, the packaging design and functions were set up based on the survey results by the user and feasible model can be produced based on user choice. The measurement in the three environment has been done after manufactured the sensor, PCB, and mobile application. As a result, it works normally within a certain range under all three environmental conditions. It is believed that the information on expiration dates and storage environment can be efficiently delivered to the consumers through developed cosmetics smart packaging and applications. The development of UI/UX design for consumer is further studied. The UX/UI design of the application plays an essential role in achieving this goal through the commercialization the cosmetic products in the wide range.

First Observational Finding of Submesoscale Intrathermocline Eddy in the East Sea using Underwater Glider (수중글라이더를 활용한 동해 아중규모 중층성 소용돌이 발견)

  • PARK, JONGJIN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.2
    • /
    • pp.332-350
    • /
    • 2019
  • Zonal hydrographic section measurements at $39.7^{\circ}N$ were conducted between $129.0^{\circ}E$ and $131.3^{\circ}E$ from August 7 to 25 in 2017 using an underwater glider. The glider traveled about 440 km for about 18 days along the 106 line of the regular shipboard measurements in the National Institute of Fishery Science (NIFS) and obtained twice a hydrographic section with high horizontal resolution. Even under the strong East Korea Warm Current with maximum speed of 0.8 m/s across the section, the glider successfully maintained the designated path within an RMS distance of 400 m. By comparing with the NIFS shipboard hydrographic section, it is confirmed that high spatial resolution measurements obtained from a glider were necessary to properly observe front and eddy variability in the East Sea where a typical spatial scale is smaller than the open oceans. From the glider section measurements, a new lens-shaped eddy was found in the thermocline. The lens-shaped anticyclonic eddy had 10~13 km in horizonal width and about 200 m in height like a typical submesoscale eddy resided within the thermocline, which was firstly named as Korea intrathermocline eddy (Keddy). The Keddy has the distinguishing characteristics of a typical intrathermocline eddy, such as a central core with anomalously weak stratification, a convex shaped lens bounded by the stratification anomaly, an interior maximum of velocity at 170 m, no surface appearance of the geopotential field, a small or comparable horizontal width relative to the first baroclinic Rossby radius of deformation, and the Rossby nubmer of 0.7.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.