• Title/Summary/Keyword: 회전력

Search Result 975, Processing Time 0.033 seconds

Application of Automated Microscopy Equipment for Rock Analog Material Experiments: Static Grain Growth and Simple Shear Deformation Experiments Using Norcamphor (유사물질 실험을 위한 자동화 현미경 실험 기기의 적용과 노캠퍼를 이용한 입자 성장 및 단순 전단 변형 실험의 예)

  • Ha, Changsu;Kim, Sungshil
    • Economic and Environmental Geology
    • /
    • v.54 no.2
    • /
    • pp.233-245
    • /
    • 2021
  • Many studies on the microstructures in rocks have been conducted using experimental methods with various equipment as well as natural rock studies to see the development of microstructures and understand their mechanisms. Grain boundary migration of mineral aggregates in rocks could cause grain growth or grain size changes during metamorphism or deformation as one of the main recrystallization mechanisms. This study suggests improved ways regarding the analog material experiments with reformed equipment to see sequential observations of these grain boundary migration. It can be more efficient than the existing techniques and carry out an appropriate microstructure analysis. This reformed equipment was implemented to enable optical manipulation by mounting polarizing plates capable of rotating operation on a stereoscopic microscope and a deformation rig capable of experimenting with analog materials. The equipment can automatically control the temperature and strain rate of the deformation rig by microcontrollers and programming and can take digital photomicrographs with constant time intervals during the experiment to observe any microstructure changes. The composite images synthesized using images by rotated polarizing plates enable us to see more accurate grain boundaries. As a rock analog material, norcamphor(C7H10O) was used, which has similar birefringence to quartz. Static grain growth and simple shear deformation experiments were performed using the norcamphor to verify the effectiveness of the equipment. The static grain growth experiments showed the characteristics of typical grain growth behavior. The number of grains decreases and the average grain size increases over time. These case experiments also showed a clear difference between the growth curves with three temperature conditions. The result of the simple shear deformation experiment under the medium temperature-low strain rate showed no significant change in the average grain size but presented the increased elongation of grain shapes in the direction of about 53° regarding the direction perpendicular to the shearing direction as the shear strain increases over time. These microstructures are interpreted as both the plastic deformation and the internal recovery process in grains are balanced by the deformation under the given experimental conditions. These experiments using the reformed equipment represent the ability to sequentially observe changing the microstructure during experiments as desired in the tests with the analog material during the entire process.

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

Spatial changes of the maxillofacial complex following maxillary protraction of human dry skull (건조 두개골에서 상악의 전방 견인후 상악 안면 복합체의 공간 변화에 관한 연구)

  • Chun, Youn Sic;Choi, Jang Woo;Choi, Seung Eun;Lee, Seong Geun
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.425-434
    • /
    • 2002
  • The purpose of this investigation was to study the spatial changes of the maxillofacial complex following maxillary protraction transmitted to the center of resistance of a dry juvenile human skull by a modified maxillary protraction appliance. Four dry juvenile human skulls (without mandible) with well aligned upper deciduous dentition and early mixed dentition were used as experimental samples. A modified protraction headgear was fabricated from a Delare's facemask, and following an alginate impression, an orthodontic resin maxillary splint was made for each dry skull. Protraction force level was maintained at approximately 1000gm per side for 6 hours. Cephalometric radiographs were taken pre- and post- protraction, and nine reference markers with 1.5 mm length of $.017\times.025$ TMA wire were placed on the right side of the skull for an accurate superimposition of serial cephalometric radiographs. The present investigation demonstrated that vertical changes associated with an anterior displacement of the maxillary complex was observed, and the most prominent effect of protraction headgear was a counterclockwise rotation of the maxilla, that is, a forward and downward tipping around the palatomaxillary region.

Evaluation of Insertion of torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone (다양한 교정용 미니 스크류의 인공 피질골 두께에 따른 삽입 토오크와 Pull-out 강도 비교)

  • Song, Young-Youn;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.5-15
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the mechanical performance of mini-screws during insertion into artificial bone with use of the driving torque tester (Biomaterials Korea, Seoul, Korea), as well as testing of Pull-out Strength (POS). Methods: Experimental bone blocks with different cortical bone thickness were used as specimens. Three modules of commercially available drill-free type mini-screws (Type A; pure cylindrical type, Biomaterials Korea, Seoul, Korea, Type B; partially cylindrical type, Jeil Medical, Seoul, Korea, Type C; combination type of cylindrical and tapered portions, Ortholution, Seoul, Korea), were used. Results: Difference in the cortical bone thickness had little effect on the maximum insertion torque (MIT) in Type A mini-screws. But in Type B and C, MIT increased as the cortical bone thickness Increased. MIT of Type C was highest in all situations, then Type B and Type A in order. Type C showed lower POS than Type A or B in all situations. There were statistically significant correlations between cortical bone thickness and MIT, and POS for each type of the mini-screws. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the best suitable screw design should be selected according to the different cortical thicknesses at the implant sites.

2D Indoor Map Building Scheme Using Ultrasonic Module (초음파 센서 모듈을 활용한 2D 실내 지도 작성 기법)

  • Ahn, Deock-hyeon;Kim, Nam-moon;Park, Ji-hye;Kim, Young-ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.8
    • /
    • pp.986-994
    • /
    • 2016
  • In this paper, we proposed ultrasonic radar module and fixed module for the 2D indoor map building and from each of the modules, we can see the possibilities, limitations and considerations. And finally show the result of building actual 2D indoor map from the modules. Recently there are lots of works for the building indoor map by spotlight on the simultaneous localization and mapping (SLAM). And the LiDAR, ultrasonic, camera sensors are usually used for this work. Especially the LiDAR sensor have a higher resolution and wider detection range more than the ultrasonic sensor, but also there are limitation in the size of module, higher cost, much more throughput of processing data, and weaker to use in various indoor environment noises. So from these reasons, in this paper we could verify that proposed modules and schemes have a enough performance to build the 2D indoor map instead of using LiDAR and camera sensor with minimum number of ultrasonic sensors and less throughput of processing data.

Disk harrow structure analysis of non-motorized composite implement of tractor (무동력 트랙터 복합작업기의 디스크 구조해석)

  • Lee, Choong Ho;Jang, Ji Un;Lee, In Beom;Kim, Hyun Gyung
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.85-85
    • /
    • 2017
  • 무동력 복합작업기는 치즐쟁기와 디스크의 배열에 따라 작업성능이 좌우된다. 프레임과 디스크, 치즐쟁기에 가해지는 기본적인 힘의 상태를 확인하기 위한 정적 구조해석을 수행하였다. 복합작업기는 디스크는 $18^{\circ}$가 경사진 형태로 전면9개 후면9로 총 18개, 치즐쟁기(Chiselplow)는 4개로, 디스크는 모두 18개이다. 정적인 상태에서 끄는 견인력은 100마력, 150마력, 200마력으로 하였으며 Inventor의 해석 시스템은 힘을 N으로 사용하기 때문에 각 마력에 부가되는 하중을 N으로 치환하여 사용하였다. 구속조건은 frame과, disc, chisel plow에 맞닿는 면을 구속하고, 힘의 방향은 프레임과 트랙터의 연결면, 디스크 날과 땅의 접촉면에 적용했다. front /rear 디스크는 이론상으로는 양 디스크가 쌍으로 마주하고 있어서 스캔데이타를 중심으로 모델링한 결과를 바탕으로, 전후면 디스크해로우의 해석을 수행하였다. 조립 또는 사용상의 문제점이나 자연적인 유격에 의해 어느 정도 대칭이 되지 않을수 있으나 그 정도에 따라 진동과 내구성에 문제가 될 수도 있기에 한쌍에 대해 모델링을 통한 해석을 수행하였다. 해석결과에 따르면 디스크에 작용하는 폰미세스 응력은 극한강도에 미치지 않은 것으로 나타났으며 Frame의 최대 폰 미세스 응력을 제외하면, 대부분의 응력은 항복강도에 현저히 미치지 못하는 수치이고, 프레임의 경우는 150마력, 200마력으로 힘을 가할 때 항복강도는 넘는 수치이지만 극한인장강도에는 미치지 못하는 수치인 것을 알 수 있었다. 100마력에 폰 미세스 응력의 최대값은 0.161918 MPa이고 프레임 강의 항복강도인 207MPa와 디스크의 항복강도인 250MPa에 못 미치는 수치이다. 150마력과 200마력의 힘으로 회전할 때의 폰 미세스 응력의 최대값은 0.286425MPa과 0.381921 MPa로 항복강도인 250MPa에 크게 못 미치는 수치이다. 그 이유는 디스크해로우 방식의 복합작업기는 견인저항력이 작게 설계되고 작업속도를 개선하기 위한 목적으로 사용되기 때문으로 사료된다. 벤치마킹 기대의 Rear 디스크도 마찬가지로 각도는 $18^{\circ}$이며, 동일한 구속조건을 적용하여 시뮬레이션을 수행하였으며 해석결과는 모두 항복강도 이내로 예측 되었다. 디스크에 최대로 응력이 미치는 부분은 디스크와 프레임이 연결되는 허브 부분이다. 각도가 커짐에 따라 응력이 증가하므로 이를 감안한 설계인자 도출이 가능하다. 마력과 각도가 증가함에 따라 디스크 해로우에 작용하는 폰미세스 응력과, 접촉압력이 증가하므로 이에 대한 검토와 동적하중인 로드프로파일을 적용한 해석을 수행하여 내구수명 특성에 대한 연구를 수행할 계획이다.

  • PDF

A FEM study about the initial stress distribution on canine altered by the application point of preangulated TMA T-loop spring (Preangulated TMA T-loop spring의 적용 위치 변화에 따른 견치의 초기 응력 분포에 대한 유한 요소법적 연구)

  • Kim, Jung-Min;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.521-534
    • /
    • 1999
  • The purpose of this study was to find the difference of stress distribution on canine altered by the application point of preangulated T-loop spring. For this study, the finite element models of upper left canine, upper left second premolar and upper left first molar were made. Also, the finite element models of $0.017{\times}0.025$ inch preangulated, preactivated T-loop spring and $0.018{\times}0.025$ inch stainless steel wire were made. Three types of T-loop spring were made . the middle of activated T-loop is positioned in accordance with the middle position of distance of bracket position of both the canine and first molar, 2mm anterior, 2mm posterior. We compared the forces and the distribution of stress that were generated by the difference of position of T-loop spring. The results were as follows. 1. All of the 3 types of T-loop spring showed the similar retraction forces. 2. All showed the similar amount & pattern of stress distribution. 3. The centers of rotation of canine in 3 types of T-loop spring were same and were positioned between C and D plane. 4. The canine showed the intrusive force by 2mm anterior positioned T-loop spring, but the extrusive force by 2mm posterior positioned T-loop suing. Neverthless, because of the small amount of the forces, the effect of vertical force was not significant.

  • PDF

Examination of the Flick-Flack Salto Backward Stretched of Success and Fall Occurs on the Balance Beam (평균대 백핸드 수완 동작 성.패 시 실수요인 규명)

  • So, Jae-Moo;Kim, Yoon-Ji;Kim, Yong-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.137-146
    • /
    • 2008
  • The purpose of this study is to examine the causes of errors from EGR posture on the balance beam, which is bending flick-flack salto backward stretched national team players through kinematic analysis, and present training methods for them so as to provide scientifically useful information to coaches and athlete. Findings from this study are summarized below. The most important factors that affect the errors in boyd center position and speed change were the speed change of left and right body centers and the horizontal and vertical speed changes. The left and right acceleration changes were greater in failed posture than in successful posture. The horizontal and vertical accelerations in E3 and E5 were the key factors that affected the backward somersault and landing. The angular speed changes which varied between success and failure were notable in head and shoulder joints. In individual results. The section when the angular speeds of head and shoulder joint must be the greatest was E4. In this section, when the body is extending instantly in a bent posture, increasing the angular speeds of head, shoulder and hip joints can improve the duration of staying in the air and the rotation radius of a somersault.

THE TREATMENT OF AN ANTEIOR CROSS-BITE WITH THE ERUPTION OF A MAXILLARY INCISOR USING $FR\ddot{A}NKEL$ III : CASE REPORT (상악중절치 맹출시기의 $Fr\ddot{a}nkel$ III를 이용한 전치부 반대교합의 치험례)

  • Lee, Sang-Youp;Kim, Hyun-Jung;Nam, Sun-Heun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.323-330
    • /
    • 1999
  • It is well recognized that a cross-bite tends to occur more frequently among Japanese, Chinese and Koreans more than among Europeans. A variety of functional appliances have already invented for the treatment of cross-bites. One of them is the FR III(by Rolf $Fr\ddot{a}nkel$) which applies a quite different philosophy based on the using vestibular region compared with other methods which utilize muscular forces applied directly on the teeth. The FR III also increases both the lack of muscular tension against the dental arch and the dentition and muscular forces which can then influence the teeth indirectly. This mechanism can achieve favorable developments with the basal bone, teeth, and alveolar bone. After using FR III to the anterior cross-bite patient with the eruption of a maxillary incisor the results were as follows: 1. Forward growth of maxilla and proclination of the upper incisor 2. Downward and backward rotation of the mandible 3. Increase the facial height 4. The case which was normal mandible, underdevelopmental maxilla, deeper overbite and more nagative overjet exhibited good prognosis

  • PDF

SHORT-TERM EFFECTS OF THE FUNCTIONAL REGULATOR III APPLIED TO ANTERIOR CROSSBITE PATIENTS IN EARLY MIXED DENTITION (기능성 반대교합을 가진 초기 혼합치열기 어린이에서 FR III를 단기간 장착했을 때의 효과)

  • Woo, Se-Eun;Nam, Soon-Hyeun;Kim, Young-Jin;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.3
    • /
    • pp.293-300
    • /
    • 2012
  • In case of treating the functional type of anterior cross bite, removing the cause in early stage prevents from turning to skeletal type, leads to perform normal function, and has improved facial appearance. Functional Regulator III (FR III), one kind of the Functional regulator(FR)s suggested by R$\ddot{o}$lf Fr$\ddot{a}$nkel in 1966, applied to patients with the functional and skeletal anterior crossbite in early mixed, and permanent dentition. This appliance improves unbalanced power condition by blocking abnormal muscle-power effect, so that normal growth can be expected. In this case report, favorable results were obtained by selecting clinical cases of children in their early mixed dentition with functional cross bite. 1. FR IIIs were applied to patients with anterior crossbite for 5~6 months. Anterior crossbite patients were corrected favorably, nevertheless they didn't show any horizontal skeletal-changes by buccal shields. 2. Normal occlusion and esthetic facial contour were achieved from dental movement of maxillary and mandibular anterior teeth while the mandible rotates to posterior and inferior direction.