• Title/Summary/Keyword: 회전각도

Search Result 590, Processing Time 0.023 seconds

Navigation Strategy Of Mobile Robots based on Fuzzy Neural Network with Hierarchical Structure (계층적 구조를 가진 Fuzzy Neural Network를 이용한 이동로봇의 주행법)

  • 최정원;한교경;박만식;이석규
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.11 no.5
    • /
    • pp.367-372
    • /
    • 2001
  • This paper proposes a hierachically structured navigation algorithm for multiple mobile robots under unknown dynamic environment. The proposed algorithm consists of three basic parts as follows. The first part based on the fuzzy rule generates the turning angle and moving distance of the robot for goal approach without obstacles. In the second part, using both fuzzy and neural network, the angle and distance of the robot to avoid collision with dynamic and static obstacles are obtained. The final adjustment of the weighting factor based on fuzzy rule for moving and avoiding distance of the robots is provided in the third stage. Some simulation results show the effectiveness of the proposed algorithm.

  • PDF

Effects of Bleed Flow and Angled Ribs on Heat Transfer Distributions in a Rotating Square Channel (유출유동 및 각도진 요철이 회전하는 사각덕트 내 열전달분포에 미치는 영향)

  • Park, Suk-Hwan;Jeon, Yun-Heung;Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.76-82
    • /
    • 2007
  • The present study investigated the effects of channel rotation and bleed flow on heat/mass transfer in a square channel with $45^{\circ}$ rib turbulators. The bleed holes were located between the rib turbulators on the leading surface and those on the trailing surface case by case. The tests were conducted under the conditions of various bleed ratios (0.0, 0.2, 0.4) and rotation numbers (0.0, 0.2, 0.4) at Re=10,000. The results suggested that heat/mass transfer characteristics were influenced by the Coriolis force, decrement of main flow rate, secondary flow by angled ribs and bleed hole location. As the bleed ratio (BR) increased, the heat/mass transfer decreased on both surfaces due to the reduction of main flow rate. With increment of the rotation number, heat/mass transfer also decreased and almost the same because the reattachment of the secondary flow induced by angled ribs was weakened on the leading surface and the secondary flow was disturbed on the trailing surface by the Coriolis force.

An Optical Analog Encoder for Precise Angle Control of SRM (SRM의 정밀 각도제어를 위한 아날로그 엔코더)

  • 안진우;황형진;이동희;박성준
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • In a switched reluctance motor drive, it is important to synchronize the stator phase excitation with the rotor position, Therefore the position of rotor is an essential information. Although high resolution optical encoder/resolvers we used to provide a precise position information, these sensors are expensive. And switching angles synchronizing using sensorless technique has some problems like a reliability and fluctuating of the preset value in the high-speed region, which is caused by the sampling period of the microprocessor. In this paper, a low cost analog encoder suitable for practical applications is proposed. And the control algorithm to generate switching signals using a simple digital logic is presented. The validity of the proposed analog encoder with a proper logic controller is verified from the experiments.

New 4-Dimensional Constellation-Rotation Modulation Method for DVB-NGH (DVB-NGH를 위한 새로운 4차원 성상 회전 변조기법)

  • Kim, Jun-Ho;Kim, Ho-Jun;Jung, Tae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11A
    • /
    • pp.1073-1077
    • /
    • 2010
  • This paper proposes a new 4-dimensional(4D) constellation-rotation(CR) method which obtains diversity gain of 4 under Rayleigh fading channels. The proposed scheme uses two consecutive CR operations for the constellation of QAM signals unlike a conventional 2-dimensional(2D) CR method using only one CR operation. The computer simulation results show that the new method outperforms the conventional one even more as both the channel code rate and the erasure ratio increase. In a point of system flexibility, the proposed scheme has a great advantage since the conventional 2D CR scheme can be simply implemented by only changing rotation angle values used in the proposed scheme.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (I) - Cross Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (I) - 엇갈린 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.873-881
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached crossly in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2mm(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (pie) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of cross rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with cross NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with cross NP or PP type ribs.

Pressure Drop Distributions in Rotating Channels with Turning Region and Angled Ribs (II) - Parallel Rib Arrangements - (각도요철 및 곡관부를 가진 회전덕트 내 압력강하 분포 (II) - 평행한 요철 배열 -)

  • Kim, Kyung-Min;Park, Suk-Hwan;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.882-890
    • /
    • 2006
  • The present study investigates the pressure drop characteristics in rotating two-pass ducts. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter $(D_h)$ of 26.67mm. Rib turbulators are attached parallel in the four different arrangements on the leading and trailing surfaces of the test ducts. The ribs have a rectangular cross section of $2m(e){\times}3mm(w)$ and an attack angle of $70^{\circ}C$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio $(e/D_h)$ is 0.075. The results show that the highest pressure drop among each region appears in the turning region for the stationary case, but appears in the upstream region of the second pass for the rotating case. Effects of parallel rib arrangements are almost the same in the first pass for the stationary and rotating cases. In the second pass, however, heat transfer and pressure drop are high for the cases with parallel NN or PP type ribs in the stationary ducts. In the rotating ducts, they are high for the cases with parallel NN or PN type ribs.

Vortex breakdown in an axisymmetric circular cylinder with rotating cones (회전하는 원뿔의 각도에 따른 축 대칭 원통형 용기에서의 와동붕괴에 관한 연구)

  • Kim, J.W.;Eum, Ch.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.55-63
    • /
    • 1997
  • A numerical investigation has been made for flows in an axisymmetric circular cylinder with an impulsively rotating cone located at the bottom of the container. The axisymmetric container is completely filled with a viscous fluid. Major parameter for the present research is only the vertex angle of the cone, otherwise Reynolds number and aspect ratio of the vessel are fixed. Main interest concerns on the vortex breakdown of meridional circulation by impulsive rotation of the cone with respect to the longitudinal axis of the cylinder. Numerical method has been used to integrate momentum and continuity equations on a generalized body-fitted grid system. The pattern of vortex breakdown is quite different from that in a right circular cylinder with flat endwall disks. The flow visualization photograph of the preceeding work by Escudier is compared with the present numerical results and the two results are in good agreements. Also flow data are plotted to gain a deep understanding for the present phenomena of the vortex breakdown. The conclusions of this work are clearly explained by the classical theory of the vortex flows in a finite geometry.

  • PDF

Effects of the Pelvic Control Method on Abdominal Muscle Activity and Lumbopelvic Rotation Angle during Active Straight Leg Raising in Patients with Chronic Low Back Pain (만성요통환자의 능동 하지직거상 동작 시 골반조절 방법에 따른 복부 근활성도와 요골반부 회전각도에 미치는 영향)

  • Kim, Dae-Hyun;Park, Jin
    • PNF and Movement
    • /
    • v.18 no.2
    • /
    • pp.223-231
    • /
    • 2020
  • Purpose: The purpose of the study was to compare the effects of different methods of pelvic control on abdominal muscle activity and lumbopelvic rotation angle during active straight leg raising (ASLR) in patients with chronic back pain. Methods: The study participants were patients with low back pain (n = 30). They were instructed to perform ASLR with pelvic control, ASLR with pelvic belt, and ASLR only. Surface electromyography data were collected from the ipsilateral rectus femoris (IRF), ipsilateral internal oblique (IIO), contralateral external oblique (CEO), and ipsilateral rectus abdominal (IRA) muscles, and lumbopelvic rotation angle was measured using a motion analysis device. Results: Activation of all abdominal muscles was greater in the ASLR with pelvic control group than in the ASLR with pelvic belt and ASLR groups. The lumbopelvic rotation angle was lower in the ASLR with pelvic control group than in the other two groups (p < 0.05). Conclusion: These results suggest that ALSR with pelvic control is an effective means of increasing abdominal muscle activity and reducing unwanted lumbopelvic rotation in patients with chronic low back pain. Controlling the pelvis using the opposite leg is an effective form of ASLR exercise for patients with chronic low back pain.

선형가속기를 이용한 뇌정위 방사선수술시 Isocentric sub system의 기하학적 오차

  • 이석춘;오종영;김남석
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.45-53
    • /
    • 1995
  • 목적 : 뇌정위 방사선수술은 AVM(ateriovenous malformation)이나 작은 크기의 종양에 1회에 고선량의 방사선을 조사하는 기술이다. 선형가속기를 이용한 방사선 수술을 하기 위하여 최근 본원에 설치한 Philips SL 75-5 선형가속기와 isocentric sub system(ISS)에 의한 뇌정위 방사선 수술에 있어서 표적의 위치선정과, gantry와 couch의 회전시 기하학적 오차가 중요시 되는데 isocentric sub system의 오차를 분석 하였다. 대상 및 방법 : 방사선원으로는 Philips SL 75-5 선형가속기의 5MV 광자선을 사용하였고, 원형의 작은 광자선속을 위하여 isocenter에서의 직경이 26mm인 secondary cone을 gimbal baaring에 삽입하여 사용하였다. 표적의 크기와 좌표를 정하기 위하여 CT나 angio localizer를 이용하고, 표적좌표 선정을 위하여 BRW phantom base와 target pointer를 이용하여 임의의 BRW-coordinator를 바꾸어 가면서 gantry angle와 ISS head 각도를 임의로 바꾸어 가면서 film에 방사선을 조사하였다. 흑화된 film을 view box 위에 놓고 광학판독기구로 film 가장자리의 오차를 scale 확대경으로 측정하여 오차를 분석하였다. 결과 : 표적좌표 선정의 정확도를 확인하기 위하여 임의의 표적좌표에 gantry의 10개각도 ISShead의 10개각도에서 각각 광자선을 조사시켜 film을 이용하여 오차를 측정한 결과 collimator cone의 직경이 26mm일때 전체 평균오차가 0.219+-0.03mm이었다. 결론 : Isocentric sub system은 gantry head와 ISS arm 사이에 gimbal bearing이 있어서 이 부위를 flexible하게 연결함으로 gantry의 회전에 무관하게 정확한 isocenter를 유지시켜 주고 ISS head는 couch와 독립되어 움직이므로 isocentric sub system isocenter의 오차를 최대한 줄일수 있음을 알았다.

  • PDF

A Design of Standing Human Body Sensing System Using Rotation of a PIR Sensor (초전형 적외선 센서 회전방식을 이용한 정지 인체 감지 시스템에 관한 연구)

  • Cha, Hyeong-Woo;Cho, Min-Yyeong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.129-136
    • /
    • 2016
  • A novel sensing system for standing and moving human body using PIR(pyroelectric infrared) sensor was development. The system consists of power supply, interface circuit of PIR sensor, small stepping motor, and digital control. The detecting principle for stop human body is detecting the human body when the stepping motor sticking the PIR sensor and the fresnel lens has rotated by 180 degree at six second and has stopped the motor for no detecting signal of human body. We developed control algorism for proposed the detection system. The experimentation shows that the detector system had detected length and angle were 6m and 30 degree against as standing and moving human body with $37^{\circ}C$.