• Title/Summary/Keyword: 황인길

Search Result 7, Processing Time 0.019 seconds

Prediction of Mean Cutting Force in Ball-end Milling using 2-map and Cutting Parameter (Z-map과 절삭계수를 이용한 볼엔드밀의 평균절삭력 예측)

  • 황인길;김규만;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.179-184
    • /
    • 1995
  • A new cutting parameter is defined in the spherical part of ball end-mill cutter. A series of slot cutting experiments were carried out to obtain the cutting parameter. The cutter contact area is expressed as the grid posiotion in the cutting plane using Z map. The cutting forces in each grid are calculated and saved as force map, prior to the average cutting forces calculation. The cutting force, in the arbitrary cutting area, can be easily calculated by summing up the cutting forces of the engaged grid in the force map. This model was verified in the inclined surface cutting by cutting test of a cylindrical part.

  • PDF

The methods of distinguishing between HCC and HH in Liver CT scan (Liver CT 영상에서 간세포암과 간혈관종 구별에 대한 연구)

  • Hwang, In-gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.173-174
    • /
    • 2015
  • 간에서 발생하는 악성종양과 양성종양의 대표적 질환 으로는 간세포암(Hepatocelluar carci- noma, HCC)과 간혈관종(Hepatic hemangioma, HH)이다. CT검사를 이용한 진단에 있어서 두 질환은 시간변화에 따른 조영증강양상 차이가 나타난다. Liver 3-phase computed tomography검사를 시행하여 시간별 조영증강 양상을 알아보았다. 본 연구는 조영제 주입전, 동맥기(35sec), 문맥기(70sec), 지연기(180sec)에 대한 Enhan -cement Pattern 변화와 HU(Hounsfield unit)값 변화, pixel값 변화의 관찰로서 검증하였다. 실험결과 HU를 사용한 방법에서 의미있게 구분되었고 임상적용 시 판독에 도움을 줄 것으로 생각한다.

  • PDF

Cutting Force Prediction of Slanted Surface Ball-End Milling Using Cutter Contact Area (절삭영역 해석을 통한 경사면 가공에서의 볼엔드밀 절삭력 예측)

  • 김규만;조필주;황인길;주종남
    • Korean Journal of Computational Design and Engineering
    • /
    • v.3 no.3
    • /
    • pp.161-167
    • /
    • 1998
  • Cutting forces in ball-end milling of slanted surfaces are calculated. The cutting area is determined from the Z-map of the surface geometry and current cutter location. The obtained cutting area is projected onto the cutter plane normal to the Z-axis and compared with cutting edge element location. Cutting force is calculated by integration of elemental cutting forces of engaged cutting edge elements. Experiments with various slanted angles were performed to verify the proposed cutting force estimation model. It is shown that the proposed method predicts cutting force effectively for any geometry including sculptured surfaces with cusp marks and surfaces with pockets and holes.

  • PDF

A Case study of the automatic operation due to the Train to the Wayside to TWC communication(Focused on the Subway ATO/TWC equipment) (열차와 지상간 TWC 통신에 의한 자동운전에 관한 연구(지하철 ATO/TWC 설비를 중심으로))

  • Hwang, In-Kil;Song, Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.900-905
    • /
    • 2006
  • 5678SMRT (Seoul Metropolitan Rapid Transit Co) by a ATC/ATO system the other side which is operated with an automatic movement with a manual operation, the Seoul subway 1.2 lines ATS and 3.4 lines adopt a ATC method and they are operated. But it is improving progressively in SMRT railway ATO method. The ATO the operation method leads exchange of information of wayside and train system for and it is possible, the TWC system configuration is becoming wayside and train system and the radio antenna. It discussed the equipment for a TWC system and a automatic operation from the dissertation which it sees. It investigated a data exchange, a message format and an interface control method and it joined in and a system maintenance conservative method it discussed.

  • PDF

The Objective Image Analysis for HCC and HH with a Axial Image of Liver CT Scan (Liver CT 단면영상에서 간세포암과 간혈관종의 객관적 영상분석)

  • Hwang, In-Gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.411-417
    • /
    • 2015
  • To distinguish between HCC and HH is one of the important test methods in determining the treatment method by determining the treatment method by distinguishing malignant growth and benign tumors in liver CT scan. Currently, the specialist is reading CT images by their subjective judgment. So, the purpose of this study is to treat reading the CT images even more objective way. The test times after injection contrast medium in this study are the before injection phase(Pre.), artery phase(35sec), portal phase(70sec) and delay phase(180sec). The general pattern change of HCC in change of contrast enhancement pattern shows 26.6% matching. And the case of HH shows 16.6% matching. In order to observe the change of HU value between HCC and HH, each average values and standard deviation was confirm and as a result, it shows the lagre difference between artery and portal phase in lesion.(HCC$19.76{\pm}23.52$, HH$60.23{\pm}29.43$). And it shows the 76.6% matching in HCC and 80.0% matching in HH. Thorough this study, to suggest a HU value as objective analysis method and if the anlaysis method was used in clinical will assist in the diagnosis.