• 제목/요약/키워드: 황명근

검색결과 101건 처리시간 0.023초

폴리머 피뢰기의 해석기법 (Electric Field Analysis Method of Polymer arrester)

  • 황명근;김광호;박남식;임인택;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.303-305
    • /
    • 1997
  • The advantage of application polymer instead of conventional porcelain as the housing material for arrester is that light weight, shorter section length of arrester would be possible due to the use of an insulated hanger (mold compound). also, polymer arrester has very good characteristics in design versatility as well as excellent resistance to moist ingress and pollution performance. The finite element method is widely used to calculate for electromagnetic devices. In this paper, we perform the each conditional analysis of PC with an advanced graphical user interface(GUI) using the vector fields simulator. And we try to analyze electromagnetic fields through the conventional two dimensional analysis in case of high voltage contamination on the electrode of a arrester.

  • PDF

자동차용 LED 전조등의 기술 및 표준화 동향 (The Trend of Technique and Standardization of LED Headlamp for Automobile)

  • 신상욱;임종민;황명근;이진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.145-148
    • /
    • 2008
  • In recent years, LED's have been adopted for and ever widening range of applications and numerous examples of the replacement of incandescent and fluorescent light sources due to the dramatic improvements in the efficiency of white LED's can be found. Automotive lighting devices, as with other lighting equipment, should exhibit low power consumption, long lifetime and provide new design opportunities. In this paper, an overview of trends of technology and standardization of LED headlamp were investigated and performed various experiments using LED headlamp.

  • PDF

보정계수 산출에 의한 신광원용 표준램프 광속의 검증 (The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor)

  • 황명근;신상욱;이진우
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

수분침투로 열화된 실리콘 고무의 젼기적 염해 특성 (The Electrical Salt-Fog Performance of Si1icone Rubber Material Aged by Water Immersion)

  • 연복회;이상엽;황명근;김완태;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.25-28
    • /
    • 1998
  • In this study, we investigated the electrical characteristics of silicone rubber that being used outdoor insulating material, which had been immersed in salt water. After immersed the sample in salt water, we measured surface hydrophobicity, weight loss and microscopic surface appearance, and then compared with these of the original. And we tested the electrical characteristics of the aged sample by the water under salt-fog. These electrical characteristics are described by the average of leakage current, peak pulse number, which are recorded by data acquisition system The experimental results show that the resistance against tracking and erosion is decreased significantly by water penetration.

  • PDF

고휘도 발광다이오드(LED)의 광학적 특성에 관한 연구 (A Study of Optical Characteristics for High Intensity LED)

  • 황명근;임종민;신상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2159-2161
    • /
    • 2000
  • The LEDs are used for signal lights including traffic signals and telecommunication equipments. Advanced foreign countries are making R&D of ultra high intensity LEDs, and the LEDs are expected to new light source. Optical characteristics by measurements of 14 LEDs; each 2 of 3$\Phi$ R/G/Y LEDs, each of 5$\Phi$ Y/G/Y LEDs and each of high intensity 5$\Phi$ R/G/B/A/W LEDs. Comparison on chromaticity coordinate of high intensity 5$\Phi$ White LED by forward V/I.

  • PDF

도로조명 설계에서 보수율에 따른 광학적 특성 연구 (A Study of Optical Characteristics for Maintenance Factors on Roadway Lighting Design)

  • 황명근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2153-2155
    • /
    • 2000
  • The not an organization a branch stream the maintenance factor class on a class and the roadway type for roadway lighting design, the facted an insufficiency maintenance factor to apply our the country conditions. The consideration of maintenance factors is not being fully applied for roadway lighting design in Korea. This paper consider optical characteristics and maintenance factors as well as LID of Luminaires in designing roadway lighting. Consideration of maintenance factors that are neme specified according to LDD(Luminaire Dirt Depreciation), LLD(Lamp Lumen Depreciation), AADT(Average Annual Daily Traffic) based on IESNA regulation. The analyzed optical characteristics are applied for stagger and cross roadway types with maintenance factors in the range of 0.51$\sim$1.00 and equipment factor of 0.9.

  • PDF

광속의 열화시험을 이용한 광원의 수명분포 분석 (The Analysis of life distribution for Light Source using degradation Tests of Luminous Flux)

  • 이세현;신상욱;조미령;황명근;양승용
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.161-165
    • /
    • 2005
  • In this paper, we observed degradation characteristics of luminous flux for new light source. Because degradation tests can be a useful tool for assessing the reliability when few or even no failures are expected in a life tests. And we use a simple random coefficient degradation model to induce most suitable equation of degradation. As a result, exponential distribution and equation is best suitable model for new light source.

  • PDF

무전극 형광램프 시스템의 서어지 특성 연구 (The surge characteristics research of an electrodeless fluorescent lamp system)

  • 이세현;신상욱;조미령;황명근;함중걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.141-148
    • /
    • 2004
  • In this paper, we have investigated the inductive voltages, currents, frequencies of output line of electrodeless fluorescent lamp system as an surge is supplied and have analyzed the surge characteristics as an phase alteration of input voltage with an surge suppling. A result os measurement is that the inductive over-voltages(H-PE, N-PE) on output line of electrodeles fluorescent lamp system showed more high than inductive overvoltages of H(hot)-N(neutral) line. Therefore, designer of system will lay emphasis on an protective circuit with considening an overvoltage(H-PE, N-PE) or phase of input voltage.

  • PDF

단일탐침법을 사용한 평판형 광원의 제논 (Xe) 플라즈마 특성 연구 (Xe Plasma Property with Flat Lamp by Langmuir Probe)

  • 백광현;이종찬;황명근;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권1호
    • /
    • pp.50-54
    • /
    • 2006
  • The study on discharge of the flat lamp lighting source has been requested increasingly. To improve the brightness, life time and efficiency of flat lamp, the plasma diagnosis of flat lamp lighting source is very important. When a distance of discharge electrode is 5.5mm and width is 16.5mm, we measured electron temperature and electron density with single Langmuir probe in flat lamp. Pressure conditions to test the plasma discharge from 100 Torr to 300 Torr. The power supply was PDS-4000 with frequency 20kHz and duty ratio $20\%.$ Form these experimental results, electron temperature was decreased according to increase the gas pressure and the voltage while electron density was increased.

고효율 무전극 형광등 시스템의 표준화에 관한 연구 (A Study on the Standards of High Efficiency Electrodeless Fluorescent Lamps)

  • 조미령;신상욱;이세현;황명근;이도영;양승용;함중걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1667-1668
    • /
    • 2006
  • Electrodeless fluorescent lamps don't have standards yet. So we study applicable standards of electrodeless fluorescent lamps and analyze evaluation items and test method. Then we will use this paper basic information of standards.

  • PDF