• Title/Summary/Keyword: 활성탄 생물막 공정

Search Result 7, Processing Time 0.03 seconds

Biological Activated Carbon (BAC) Process in Water Treatment (정수처리에서의 생물활성탄 공정)

  • Son, Hee-Jong;Yoo, Soo-Jeon;Roh, Jae-Soon;Yoo, Pyong-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.4
    • /
    • pp.308-323
    • /
    • 2009
  • This review paper serves to describe the composition and activity of biological activated carbon (BAC) biofilm which is considered as a progressive process for water treatment. As well as several physical-chemical, biochemical and microbiological analysis methods for characterizing the composition and activity of BAC biofilm, the ability of the biofilm to remove and biodegrade organic matters and pollutants related to other water treatment processes such as pre-ozonation will be reviewed. In this paper, conversion of GAC into BAC, removal mechanism of pollutants, characteristics and affecting factors of BAC biofilm, and modeling of BAC are described in detail. In addition, strategies to control the growth of the BAC biofilm, such as varying the nutrient loading rate, altering the frequency of BAC filter backwashing and applying oxidative disinfection, will be dwelled on related to their respective process control challenges.

Advanced Swine Wastewater Treatment with using Membrane Bioreator(A/O) and Nanofiltration (MBR(Membrane Bioreactor: A/O)공정과 나노여과를 이용한 축산폐수 고도처리)

  • 장경국;배태현;김은영;장하원;탁태문
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.115-118
    • /
    • 2004
  • 축산폐수에 대한 방류수 수질기준 항목에 COD의 추가 및 질소와 인의 기준이 강화(1999년)됨에 따라 많은 축산폐수처리시설의 보강과 새로운 기술도입이 요구되고 있다. 따라서 대부분의 공공처리시설에서는 질소 및 인을 제거하기 위하여 2차 처리단계에서 무산소조(탈질조)와 호기성(포기조)를 연계한 생물학적 질소제거를 실시하고, 최종처리단계에서 응집제 투입에 의한 응집ㆍ침전공정후 모래여과 또는 활성탄 흡착공정에 의한 인과 색도제거 하는 등, 생물학적 처리 및 물리ㆍ 화학적 처리시설이 추가적으로 보완ㆍ적용단계에 있다.(중략)

  • PDF

한외여과(UF)막을 이용한 상수처리 공정의 확립 및 최적화

  • 정두식;오중교;이태진;이용택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.41-42
    • /
    • 1995
  • 기존의 정수처리 공정은 응집-침전-급속여과처리를 주로 사용하면서 생물 활성탄처리-오존처리 등을 거치는 공정으로 이루어져 왔다. 그러나 응집제의 투여시 최적 응집제량, 최적 응집제 투여위치, 교반시간, pH 조절 등 번거러운 test가 선행 되어야 하며 처리수에 남아있는 응집제에 의해 2차 오염을 일으켜 침전조의 부지 면적에 따른 대형화등을 초래할 단점이 있다. 따라서 최근에는 이러한 단점을 보완하고 장치의 간소함, 높은 효율의 유지에 따른 후처리 공정의 부하감소 및 운전 조건 인자등의 감소라는 경제적 효과를 기대할 수 있는 막분리공정이 도입되었다. 그러나 분리막 처리공정의 경우 원수에 다량 포함되어 있는 콜로이드 입자들에 의한 flux의 감소 및 fouling 현상으로 인한 막의 수명감소, 처리수량의 감소 및 최적 설계 및 운전 방법등의 새로운 공정에 대한 많은 자료의 확보가 필요하다. 따라서 본 연구는 기존의 정수처리 공정에 있어서 전처리 부분에 해당하는 응집-침전-급속여과처리 공정을 분리막 공정으로 대체 하였을 때 분리막의 재질 및 module의 차이에 따른 처리 능력을 비교하고 각 단위 공정들에 의한 flux 변화, 각 공정별 수질분석, 회복율, 회수율 등을 검토하여 최적 조건의 공정을 확립하여 후처리 공정의 효율을 극대화 하는데 있다.

  • PDF

Water Quality Improvement of Stagnant Water using an Upflow Activated Carbon Biofilm Process and Microbial Community Analysis (상향류 활성탄 생물막 공정을 이용한 정체 수역 수질 개선 및 공정 내 미생물 군집 해석)

  • Oh, Yu-Mi;Lee, Jae-Ho;Park, Jeung-Jin;Choi, Gi-Choong;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.23-32
    • /
    • 2010
  • The capacity of natural purification was limited by the interruption of natural flow and the problems such as eutrophication were occurred by nutritive salts accumulation in stagnant stream. Moreover, the inflow of non-point sources causes non-degradable materials to increase in stagnant stream. In this study, an upflow biological activated carbon (BAC) biofilm process comprised of anoxic, aerobic 1, and aerobic 2 reactors were introduced for treatment of stagnant stream and SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP were monitored in the upflow BAC biofilm reactors with continuous cycling. In order to simulate stagnant stream, the lake water of amusement park and golf course were stored as influent in a tank of $2m^3$ and hydraulic retention time (HRT) was changed into 6, 4, and 2 hours. At HRT 4hr and the lake water of amusement park as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN, and TP showed the best water quality improvement and were 69.8, 83.0, 91.3, 74.1, 74.7, and 88.9%, respectively. At HRT 4hr and the lake water of golf course as influent, the removal efficiencies of SS, $BOD_5$, $COD_{Mn}$, $COD_{Cr}$, TN and TP were 78.5, 78.0, 80.2, 74.9, 55.6 and 97.5%, respectively. As the results of polymerase chain reaction - denaturing gel gradient electrophoresis (PCR-DGGE), microbial community was different depending on influent type. Fluorescence in situ hybridization (FISH) showed that nitrifying bacteria was dominant at HRT 4 hr. The biomass amount and microbial activities by INT-DHA test were not decrease even at lower HRT condition. In this study, the upflow BAC biofilm process would be considered to the water quality improvement of stagnant stream.

The Application of RO Membrane System in Municipal Wastewater Reclamation (RO Membrane System을 이용한 도시하수처리)

  • 이규현;안준수;유제강
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.78-95
    • /
    • 1991
  • Water factory 21(WF 2) in Orange County California, is a advanced wastewater treatment(AWT) plant designed to reclaim biologically treated munidpal wastewater for injection into a seawater barrier system. Processes included are lime treatment air stripping, filtration, activated carbon adsorption, reverse osmosis(RO), and chlorination. The effectiveness of each treatment process is presented including pretreatment, RO dimineralization. The data collected show that the processes, including RO, used at WF-21 are capable of producing a very high quality water on a reliable basis. Treatment reduced all contaminants, to levels below national primary drinldng water regulation maximum contaminant levels. It was found that lime clarified secondary effluent can be used as feedwater to a RO dimineralizer. Experiments with new low pressure membrane(250psi) show great potential for reducing RO cost.

  • PDF

Evaluation of Microbes through Microfiltration within the Water Treatment Processes (정밀여과막 및 입상활성탄을 이용한 수처리 공정에 따른 박테리아 거동 평가)

  • Shim, Moon Jung;Lim, Jae Won;Kim, Tae Ue
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.3
    • /
    • pp.230-236
    • /
    • 2016
  • Economic growth has increased the living standards around the world. Water pollution, in particular, is a public relations issue because it poses a direct threat to everyone's lives. As of recently, the production of taste and odor (T&O) compounds has been a common problem in the water industry. The adsorption process using granular activated carbon (GAC) has been the most widely used process. The objectives of this study were to evaluate the microorganisms before and after the backwashing of GAC and to identify the species of the microorganisms found. Five dominants microorganisms were confirmed after the microfiltration process from backwashing of GAC, and the dominant bacterial species were found to be ${\beta}$-proteobacterium species, Porphyrobacter donghaensis, Polaromonas rhizophaerae, Hydrogenophaga species, and Pseudonocardia species. However, when UV treatment after microfiltration was performed, Hydrogenophaga species and Psedonocardia species were eliminated. Herein, I conclude that the UV treatment post microfiltration process is more efficient than microfiltration process alone. The findings of this study may provide useful information regarding the management of microfiltration process.

Technical Evaluation of MBR Process for the Wastewater Treatment of Beverage Fabrication Processes (음료수 제조 공정 폐수의 MBR 처리 기술 평가)

  • Jung, Cheol Joong;Park, Jong Min;Kim, Youn Kook
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • Manufacturing facility for non-alcoholic drink, the parts of the food industry, disposes wastewater which includes high organic concentration and low nitrogen, phosphorus concentration. For this kind of wastewater, the treatment plant consists mainly of aerobic reactor and chemical coagulation process. And sand-filter or activated carbon process is normally installed further. However, aerobic reactor must have long HRT to treat high concentration of organic contaminant included in this wastewater, so the large site area is required. And settling tank which is normally applied for wastewater treatment facility has some problems such as water quality degradation caused by the sludge spill. To solve these problems, we applied MBR system for the wastewater. And the MBR pilot plant was installed nearby the wastewater treatment facility of W food factory and operated during long term to evaluate treatment efficiency. This plant was operated about 3 months and than the result was 97% of organic removal rate on conditions of flow rate $20m^3/day$, HRT 29 hr, recycle 4Q. However, contaminant removal ratio of bio-reactor decreased and TMP of membrane increased rapidly on more conditions.