• Title/Summary/Keyword: 환기 해석

Search Result 519, Processing Time 0.023 seconds

A study of Heat & Smoke Extraction Effects by the Various Operation of funnel Fan Shaft Ventilation (터널팬 샤프트 환기 방식에 따른 열 및 연기배출효과에 관한 연구)

  • Rie, Dong-Ho;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.49-56
    • /
    • 2004
  • Today's popular ventilation systems include the combined jet fans and electrostatic precipitation systems or the combined jet fans and vertical shaft system. Tunnels with these two ventilation systems applied have been designed and opened, more and more interest has been put in maintenance of a tunnel after opening. Therefore. it is to become more important to come up with the optimal operation mode and the method for the evaluation of ventilation system. In this study, to evaluate a tunnel ventilation and its economy, a dynamic simulation program was developed which can simulate the unsteady-state tunnel air velocity and concentration of pollutants according to the traffic flow variations and operation condition of a ventilation system. We clarified the effectiveness usage on tunnel ventilation by using it and also we could found the most economical ventilation operation mode by application in real exit tunnel. We obtained that combination of fan system and electrostatic precipitation system was more economical than jet fan priority operation mode.

Development of a program to predict the airflow rate and pollutant concentration in complex network-type tunnels (네트워크형 터널의 풍량 및 농도해석 프로그램 개발연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Ryu, Ji-Oh;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.213-229
    • /
    • 2017
  • Recently, in urban areas there is a tendency to construct more complex network-type tunnels including entrance and exit ramps. At the same time, various one-dimensional programs based on the network theory have been proposed for tunnel ventilation analysis. This paper aims at developing a program that can analyze the ventilation flow rate and pollutants concentration in complex network-type tunnels based on the none hardy-cross method. The flow analysis in the branch was carried out on the basis of the Gradient method, while for the concentration analysis a new logic has been developed to calculate the inflow and outflow concentration automatically in a complex network-type structure. Additionally, in the tunnel segments showing low flow rate, proper grid interval sizes were proposed to reduce numerical error. To verify the applicability of the program, flow rates predicted in the straight tunnels were compared with the classical velocity-diagram method by Stokic and the TVSDM program. The results showed that the errors were within 1%. In addition, the program was applied to the recent ventilation system adopted in the complex network-type urban tunnels.

Effect of the Changes in Neighboring Building Layout onto Natural Ventilation Force in Buildings (주변건물군의 변화가 건물 자연환기력에 미치는 영향에 관한 연구)

  • Kim, Mijeong;Lee, Heekwan
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2011
  • 도시의 일상생활에서는 시가지의 바람이 나무, 집 등 낮은 건축물 군에 의해 방해되어 보통은 전원의 바람보다 풍속이 저감되는 경우가 많다. 이러한 기존의 바람 흐름이 있는 곳에 건축물이 세워지게 되면 기존의 풍환경은 크게 변화되어 풍속이 약한 곳과 강한 곳이 조성되어 이와 같은 바람이 지표부근의 구조물에 의해 받는 영향은 도시지역에서 강하게 나타나게 된다. 이는 교외나 시골지역은 상대적으로 도시지역에 비해 영향을 적게 받게 된다. 임의의 지역, 특히 도시지역의 경우 기존의 건물이 증축되거나 혹은 새로운 건물이 신축되면 이로 인하여 기존의 바람흐름이 달라지며 이는 인접건물들의 확보하고 있던 자연 환기력의 변화를 야기 시키는 원인이 되기도 한다. 이러한 현상은 건축물에 의해 자연 환기력이 바뀌게 되는 일종의 기존 환경으로 부터의 변화를 의미한다. 본 연구에서는 수치해석을 이용하여 이와 같이 건물의 주변 환경변화, 즉 신축, 증축 등과 같은 변화를 고려하여 그 영향을 예측/분석하였다. 그 결과로 건물의 자연환기력을 전면에서 바람에 의한 압력증가와 후면에서 바람의 흡입에 의한 압력감소로 인해 전면의 풍속에 의해 발생하는 동압보다 큰 압력차가 발생하고, 그로 인해 환기량이 발생하는 것을 알수 있다. 주변 변화에 의해서는 동일한 규모의 건물이 추가되는 경우에 기존의 경우에 비해 35~45%의 자연환기격이 감소되는 것으로 나타났다.

Investigation of Ventilation Efficiency for the Natural Gas High Pressure Release in an Underground Valve Station (지하 공급관리소내 천연가스 고압분출시 환기효율성 검증)

  • Ha J. M.;Lee J. H.;Sung W. M.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.74-80
    • /
    • 2002
  • This study was carried out for the purpose of safety evaluation about the ventilation system (according to the structure of confined room, the position and size of vent window, the amount of blowing air, e.t.c.), which is equipped in one of KOGAS underground valve stations. Particularly, the effect of the fans placed in the upper region was focused in detail. Numerical simulation was conducted in order to predict the features of flow pattern and the diffusion of natural gas concentration. This work examined the ventilation system and resulted in proposing an optimal design of ventilation system.

  • PDF

Study on Design Factor and Design-code Development for Plate Type Heat Exchangers (판형 열교환기의 주요 설계인자와 설계프로그램 개발에 관한 고찰)

  • Ko, Jea-Hyun;Park, Kweon-Ha;Song, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1003-1009
    • /
    • 2012
  • Heat exchanger has been widely used in the industry which needs energy transport, and the application of the plate type heat exchanger having high efficiency has been greatly increased. In this study main design parameters are analyzed and new equations are induced. The induced formulation was compared with a commercial program in order to design an optimal heat exchanger. The equations of heat transfer coefficient and pressure drop for Chevron angles are introduced as functions of Reynolds number. The program implemented the equations is tested with Chevron angle variation. The results show that the convective heat transfer coefficients take errors within 8% and the pressure drops have errors within 5% in the analysis conditions.

A Numerical Study on the Effect of the Shape of Windows on the Ventilation Performance in the Storage Hall of Tripitaka Koreana at Haein Temple (해인사 장경판전 환기창 형태에 따른 환기 성능에 대한 수치해석 연구)

  • Hur, Nahm-Keon;Lee, Myung-Sung;Yang, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.119-123
    • /
    • 2007
  • Ventilation performance in the storage hall of Janggyeongpan Jeon has maintained for more than 600 years. Janggyeongpan Jeon in Haein temple has window structure of bi-level ventilating opening which consists of upper and lower window. Also, different size and shape of windows are adopted for various locations of the hall. In the present study, to analyze effect of shape of windows on ventilation performance in the storage hall, various design alternatives were considered. Numerical analysis of ventilation in the storage hall was investigated under the same simulation condition except for the shape of windows. Through the comparison of numerical results for various window designs, it was evaluated that the current windows shape gives best ventilation performance.

  • PDF

Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation (주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험)

  • Kim N.H.;Cho J.P.;Han S.P.;Choi J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

A Study on the Structural Integrity Considering the Installation of a Micro-tube Heat Exchanger (미세튜브 열교환기의 장착을 고려한 구조건전성에 관한 연구)

  • Oh, Se Yun;Kim, Tae Jin;Cho, Jong Rae;Jeong, Ho Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.447-451
    • /
    • 2015
  • The objective of this study is to predict the structural characteristics of a heat exchanger mounted on an aircraft engine using finite element analysis. The plastic fracture and life of the heat exchanger were estimated by a thermo-mechanical analysis. Tensile tests were conducted under high temperature conditions (700, 800, 900, 1000 K) using five specimens to obtain the mechanical properties of the Inconel 625 tubes. To assess the structural characteristics of the heat exchanger, the full and partial models were applied under the operating conditions given by the thermo-mechanical and inertial load. As a result, the case, tubesheet, flange, and mounting components have a reasonable safety margin to the allowable stress assuming a fatigue strength of Inconel 625 of 10000 cycles under 1000 K.